• 제목/요약/키워드: Syringe

검색결과 359건 처리시간 0.031초

In-line Automatic defect repair method for TFT-LCD Production

  • Arai, Takeshi;Nakasu, N.;Yoshimura, K.;Edamura, T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1036-1039
    • /
    • 2009
  • We have developed an automated circuit defect repair method. We focused on the resist patterns on the circuit material layer of TFT substrates before the etching process. In this paper, we report on the repair method that utilizes the syringe system and the stability of the open defect repair process.

  • PDF

The ability of using syringe irrigation and ultrasound irrigation to remove dentin debris from simulated extensions and irregularities in root canals

  • Lee, Se-Joon;Wu, Min-Kai;Wesselink, Paul-R.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 춘계학술대회
    • /
    • pp.289-289
    • /
    • 2003
  • I. Objectives Narrow long oval canals usually cannot be instrumented completely and uninstrumented extensions or irregularities usually remain. The aim of this study was to compare the ability of syringe irrigation and ultrasound irrigation to remove dentin debris from simulations of uninstrumented canal extensions and irregularities.(omitted)

  • PDF

랩온어칩 내부 미세유동제어를 위한 새로운 유동제어기법 (A New Flow Control Technique for Handling Infinitesimal Flows Inside a Lab-On-a-Chip)

  • 한수동;김국배;이상준
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.110-116
    • /
    • 2006
  • A syringe pump or a device using high electric voltage has been used for controlling flows inside a LOC (lab-on-a-chip). Compared to LOC, however, these microfluidic devices are large and heavy that they are burdensome for a portable ${\mu}-TAS$ (micro total analysis system). In this study, a new flow control technique employing pressure regulators and pressure chambers was developed. This technique utilizes compressed air to control the micro-scale flow inside a LOC, instead of a mechanical actuator or an electric power supply. The pressure regulator controls the output air pressure by adjusting the variable resistor attached. We checked the feasibility of this system by measuring the flow rate inside a capillary tube of $100{\mu}m$ diameter in the Re numbers ranged from 0.5 to 50. In addition, the performance of this flow control system was compared with that of a conventional syringe pump. The developed flow control system was found to show superior performance, compared with the syringe pump. It maintains automatically the: air pressure inside a pressure chamber whether the flow inside the capillary tube is on or off. Since the flow rate is nearly proportional to the resistance, we can control flow in multiple microchannels precisely. However, the syringe pump shows large variation of flow rate when the fluid flow is blocked in the microchannel.

Simplified HPLC Method for the Determination of Pseudoephedrine Hydrochloride from Allegra D Tablet

  • Park, Moon-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • 제15권2호
    • /
    • pp.123-126
    • /
    • 2007
  • A sensitive, simple and highly selective liquid chromatography method of determination for extraction of pseudoephedrine hydrochloride from Allegra D tablet was developed. The chief benefit of the present method is the minimal sample preparation, as the procedure is only filtering through pore syringe filter. Two drugs (pseudoephedrine hydrochloride, fexofenadine) were separated on a C$_{18}$ column and analyzed by high performance liquid chromatography (HPLC). The method had a chromatographic run time of 8.0 min. 1 ml of pseudoephedrine hydrochloride solution (1 mg/ml) was filtered through 0.22 um pore syringe filter. 50 ul of filtering solution was injected to HPLC pump and we knew the retention time (1.85 min) of separating of pseudoephedrine hydrochloride using UV detector at 280 nm. We used C$_{18}$ column (4.6 mm${\times}$250 mm), mobile phase solution (<0.05 mol/L NaH$_2$PO$_4$, 2 ml/L H$_3$PO$_4$>/CH$_3$CN / sodium dodesyl sulfate = 60 ml / 40 ml / 1 g). We separated psedoephedrine hydrochloride at run time of 1.85 min from Allegra D tablet solution (1 mg/ml) filtered through 0.22 um pore syringe filter using UV detector at 280 nm. Flow rate was set at 1.0 ml/min and the column temperature was set at 40$^{\circ}C$. Psedoephedrine hydrochloride solution (1 mg/ml) separated from Allegra D tablet was filtered through 0.22 um pore syringe filter and injected 50 ul. We confirmed the peak of psedoephedrine hydrochloride at same retention time and the separating solution was freeze-dried. In conclusion, A simple isocratic reverse-phase HPLC method has been developed that provides excellent separation of pseudoephedrine from Allegra D tablet.

원통형 바늘 구조의 플라즈마 제트 방출 특성 (Characteristics of Plasma Plume with a Cylindrical Syringe Plasma Jet Device)

  • 임현교;김동준;김정현;한상호;조광섭
    • 한국진공학회지
    • /
    • 제20권1호
    • /
    • pp.14-21
    • /
    • 2011
  • 유리관에 삽입된 주사기 바늘을 이용한 플라즈마 제트 장치의 특성을 조사하였다. 원통형 주사기 바늘 전극에 교류 고전압을 인가하고, 유리관 끝에 설치된 접지전극의 형태에 따른 플라즈마의 방출 특성을 조사하였다. 접지전극이 없는 경우 방전 개시 전압이 약 3 kV이며, 플라즈마 방사 길이는 약 10 mm이다. 또한 높은 방전 개시 전압으로 인하여 플라즈마 방사 길이 및 전류 최소량의 제어가 어렵다. 내부접지 전극의 경우는 방전 개시 전압이 약 1 kV로 낮다. 그러나 플라즈마 전류가 내부에 위치한 접지 전극으로 흐르기 때문에 유리관 끝으로부터 플라즈마가 방출되지 않는다. 외부접지 전극의 경우는 인가전압 1~2 kV에서, 방전 전류 1~4 mA이며 플라즈마 방사 길이를 0~10 mm의 범위에서 용이하게 제어된다.

조영제 자동주입기를 활용한 자기공명영상 동적검사 시 실린지 재사용의 문제 (Syringe Reuse Issues in Automated Contrast Injection System in Dynamic Magnetic Resonance Imaging)

  • 손순룡
    • 한국콘텐츠학회논문지
    • /
    • 제19권11호
    • /
    • pp.445-450
    • /
    • 2019
  • 본 연구는 자기공명영상 동적검사 시 자동주입기의 사용에 따라 조영제 역류로 인한 생리식염수의 오염 현상을 실험적으로 증명함으로써, 오염된 실린지 재사용 문제의 심각성을 인식시키고자 하였다. 연구방법은 조영제 주입 전 생리식염수와 주입 후 생리식염수를 각각 채취한 다음, T1 강조영상을 획득하여 신호강도를 측정하여 비교하였다. 생리식염수의 주입 후 신호강도가 주입 전에 비해 523.43% 통계적으로 높게 나타났다(p<0.05). 이는 조영제 주입에 따른 압력에 의해 조영제가 관을 통해 역류하여 압력이 낮은 반대쪽 생리식염수를 오염시킨 것으로 분석되었다. 결론적으로 조영제 주입 시 사용하는 실린지는 조영제 역류로 인해 교차오염이 발생하므로 정량적 분석을 위한 검사 시 동일한 환자의 검사라도 검사순서를 변경하거나 실린지를 교체하여 오류를 방지해야 한다.

PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정 (Scattering Measurement of Syringe Shield Used in PET/CT)

  • 장동근;박철우;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.375-382
    • /
    • 2020
  • PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

컴퓨터 제어 마취시스템과 통상적 마취방법을 이용한 국소 마취시 동통 비교 (Comparison of pain perception using computer-controlled anesthetic device and aspirating syringe)

  • 김용균;조익현;권진희;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제34권3호
    • /
    • pp.639-646
    • /
    • 2004
  • Dental phobia is the most prevalent fear in all age groups, across gender, and in all countries. One of the primary identified sources is the fear of dental injections in the dental phobia or the high dental fear and anxiety groups. The purpose of this study was to clinically evaluate the computer controlled anesthetic device and to compare it with traditional methods of dental anesthetic delivery. Fifty(mean age : 25.6 yrs) systemically and periodontally healthy volunteers participated in this study. The subjects were given contralateral buccal and palatal injections. One side was injected with the computer-controlled anesthetic device with a microprocessor and an electric motor to precisely regulate flow rate during administration : The experimental group. The control side was injected with a standard manual syringe, in which flow rate and pressure are operator-dependent and can't be controlled accurately : The control group. The subjects described their perceived pain experiences with two subjective scales. The results of this study were as follows: 1. The computer-controlled anesthetic device was significantly less painful than conventional syringe injection 2. The female subjects reported more pain than the male subjects. But, there were no statistical differences. 3. The anesthetic effect of both methods did not show any difference. In this study, it may be concluded that pain levels decreased significantly when the computer-controlled anesthetic device was used.

Evaluating anxiety levels and pain perception while administering local anesthesia using conventional, insulin, and deception syringes in 6-12-year-olds

  • Kohli, Neha;Hugar, Shivayogi M;Patil, Vidyavathi H;Saxena, Nivedita;Kadam, Krishna S;Karmarkar, Sanika
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권3호
    • /
    • pp.197-204
    • /
    • 2022
  • Background: Injections are one of the most fear-provoking stimuli in dentistry. Painless administration of an injection is a vital step in alleviating anxiety, which in turn leads to good behavior in children. The aim is to evaluate and compare anxiety levels and pain perception using conventional, insulin, and deception syringes during the administration of local anesthesia in children. Methods: Forty-five children aged 6-12 were selected using a standard sample size formula and equally divided into three groups. Local anesthesia was administered using a conventional syringe to Group A participants and an insulin syringe for Group B participants. Group C participants were administered local anesthesia using a deception syringe by showing the patient disposable obturation tips, and eventually a conventional syringe was used for administration of local anesthesia after hiding them from the patient. Anxiety levels were assessed using Venham's Picture Scale and pulse rate at baseline and after administration of local anesthesia. The Wong-Baker Faces Pain Rating Scale was used to assess pain perception after the administration of local anesthesia. Results: Insulin and deception syringes showed better reduction in anxiety levels and pain perception than conventional syringes, demonstrating a high statistically significant difference. Conclusion: The use of insulin and deception syringes for administration of anesthesia was demonstrated to be effective in alleviating anxiety in children and is therefore recommended as an alternative to conventional syringes.

In-line Automatic Defect Repair System for TFT-LCD Production

  • Arai, Takeshi;Nakasu, Nobuaki;Yoshimura, Kazushi;Edamura, Tadao
    • Journal of Information Display
    • /
    • 제10권4호
    • /
    • pp.202-205
    • /
    • 2009
  • An automated circuit repair system was developed for enhancing the yield of nondefective liquid crystal panels, focusing on the resist patterns on the circuit material layer of thin-film transistor (TFT) substrates prior to etching. The developed system has an advantage over the parallel conventional system: In the former, the repair conditions depend on the type of resist whereas in the latter, the repair parameters must be fine-tuned for each circuit material. The developed system consists of a resist pattern defect inspection system and a pattern repair system for short and open defects. The repair system performs fine corrections of abnormal areas of the resist pattern. The open-repair system is equipped with a syringe to dispense resist. To maintain a stable resist diameter, a thermal insulator was installed in the syringe system. As a result, the diameter of the dispensed resist became much more stable than when no thermal insulator was used. The resist diameter was kept within the target of $400{\pm}100{\mu}m$. Furthermore, a prototype system was constructed, and using a dummy pattern, it was confirmed that the system worked automatically and correctly.