• Title/Summary/Keyword: Syringe

Search Result 359, Processing Time 0.032 seconds

Syringe Infusion-based Contactless Atmospheric Pressure Ionization Mass Spectrometry for Small and Large Biomolecules

  • Lo, Ta-Ju;Chang, Chia-Hsien;Chen, Yu-Chie
    • Mass Spectrometry Letters
    • /
    • v.3 no.4
    • /
    • pp.87-92
    • /
    • 2012
  • In this study, we explored a new approach for generating ions of organics and biomolecules using contactless atmospheric pressure ionization (C-API). That is, a tapered capillary (~20 cm) was connected to a syringe, which was coupled to a syringe pump for providing a given flow rate to introduce sample solution to the proximity of a mass spectrometer. The gas phase ions derived from analytes were readily formed in the capillary outlet, which was very close to the mass spectrometer (~1 mm). No external electric connection was applied on the capillary emitter. This setup is very simple, but it can function as an ion source. This approach can be readily used for the analysis of small molecules such as amino acids and large molecules such as peptides and proteins. The limit of the detection of this approach was estimated to be ~10 pM when using bradykinin as the sample. Thus, we believe that this approach should be very useful for being used as an alternative ion source because of its low cost, high sensitivity, simplicity, and ease of operation.

Plasma Propagation Speed and Electron Temperature of Atmospheric Pressure Non-Thermal Ar Plasma Jet

  • Han, Guk-Hui;Kim, Dong-Jun;Kim, Hyeon-Cheol;Kim, Yun-Jung;Kim, Jung-Gil;Lee, Won-Yeong;Na, Ya-Na;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.512-513
    • /
    • 2013
  • Space and time resolved discharge images from an atmospheric pressure non-thermal Ar plasma jet have been observed by a ICCD camera to investigate the electron temperatures. Plasma jet device consisting of a syringe electrode inserted into a glass tube has been introduced. A high voltage is applied to the syringe electrode. The syringe needle has an outer diameter of 1.8 mm, an inner diameter of 1.3 mm, and a total length of 39.0 mm. The needle is inserted into a glass tube of outer diameter 2.4 mm and inner diameter 2.0 mm, and a total length of 80.0 mm. The Ar plasma propagation speed on the cathode has been shown to be about 2.1 km/s at input discharge voltage of 3.6 kV, discharge current of 19.9 mA and driving frequency of about 45 kHz. Particularly, the electron temperature in plasma jet were found to be about 1.8 eV at input discharge voltage of 3.6 kV and driving frequency of 45 kHz, respectively.

  • PDF

Comparison of follitropin ${\beta}$ administered by a pen device with follitropin ${\beta}$ administered by a conventional syringe in patients undergoing IVF-ET

  • Kang, Hyuk-Jae;Kim, Chung-Hoon;Ahn, Jun-Woo;Lee, Hyang-Ah;Kim, Sung-Hoon;Chae, Hee-Dong;Kang, Byung-Moon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.38 no.1
    • /
    • pp.37-41
    • /
    • 2011
  • Objective: To compare the effectiveness and convenience of a pen device for the self-administration of follitropin ${\beta}$ with a conventional syringe delivering follitropin ${\beta}$ solution in patients undergoing IVF-ET. Methods: GnRH agonist long protocol was used for controlled ovarian stimulation (COS) in all subjects. A total of 100 patients were randomized into the pen device group or the conventional syringe group on the first day of COS. Local tolerance reactions were assessed within 5 minutes, at 1 hour and at 3 hours after each injection. On the day of hCG injection, patients were asked to rate their overall pain and convenience experienced with self-injection on a visual anlaogue scale (VAS). Results: There were no differences in patients' characteristics between the two groups. The duration of COS was significantly shorter in the pen device group than in the conventional syringe group. Patients included in the pen device group needed a significantly smaller amount of follitropin ${\beta}$. However, no differences between the two groups were found in IVF results and pregnancy outcome. The incidence of local pain within 5 minutes, at 1 hour and at 3 hours after the injection was significantly lower in the pen device group. VAS scores indicated that injections using the pen device were significantly less painful and more convenient. Conclusion: The pen device for self-administration of follitropin ${\beta}$ is less painful, safer and more convenient for the patients, and can be more effective because of the shorter duration and smaller dose of follitropin ${\beta}$ when compared with the conventional syringe.

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

Oriented Barium Titanate Ceramics Made from Fiber State Powder (섬유상 분말로 제조된 배향성을 가진 $BaTiO_3$ 세라믹)

  • 서용교;야나기다히로아끼
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.12
    • /
    • pp.1066-1070
    • /
    • 1993
  • When looked upon as a polycrystalline, ceramics have two basic differences from a single crystal. One is that there exist grain boundaries, the other is that the crystal axes of each small crystal are arranged in random directions. But the crystal axes fo small crystals which compose ceramics may be made to have the tendency of being arranged in a specific direction. This is called that the crystal axes are oriented. The degree of the direction arrangement of the crystal axes is called orientation. In order to orient the crystal axes effectively, the fiberous barium titanates were made through KDC method and the ion exchange method. And then they were arranged through pressing, doctor blade, and syringe. As the result of Lotgering evaluation, the sample oriented through syringe showed the highest orientation. After sintering, though the most particles that had been fiberous shaped became global shape viewed through SEM, the orientation of the crystals was reinforced by means of sintering.

  • PDF

Prevention of tooth discoloration associated with triple antibiotics (Triple antibiotics와 관련한 치아 변색의 예방)

  • Kim, Bo-Na;Song, Min-Ju;Shin, Su-Jung;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.119-122
    • /
    • 2012
  • Regenerative endodontics has a potential to heal a partially necrotic pulp, which can be beneficial for the continued root development and strengthening of immature teeth. For this purpose, triple antibiotic mixture of ciprofloxacin, metronidazole, and minocycline was recommended as intracanal medicament in an attempt to disinfect the root canal system for revascularization of a tooth with a necrotic pulp. However, discoloration of the tooth was reported after applying this. This case shows the idea for preventing the tooth discoloration using a delivery syringe to avoid the contact between the clinical crown and the antibiotics.