• 제목/요약/키워드: Synthetic imaging

검색결과 235건 처리시간 0.033초

전자장치 응용을 위한 금속(은, 구리) 나노입자의 합성 (Synthesis of Metal Nanoparticles for the Application of Electronic Device)

  • 전병호;조수환;조정민;김성은;김동훈;김성진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.53-53
    • /
    • 2010
  • The development of synthetic pathway to produce a highly yield nanoparticles is an important aspect of industrial technology. Herein, we report a simple, rapid approach to synthesize organic-soluble Cu and Ag nanoparticles in colloidal method for the application in a conductive pattern using inkjet printing. The silver nanoparticles have been synthesized in highly concentrated organic phase. The Cu nanoparticles have been synthesized by the reducing of the copper oxide materials using acid molecules in high concentrated organic phase. Their sintering and electric conductivity properties were investigated by melting process between $200^{\circ}C$ and $250^{\circ}C$ for application to printed electronics.

  • PDF

SAR에 적용된 SVD-Pseudo Spectrum 기술 (SAR Image Processing Using SVD-Pseudo Spectrum Technique)

  • 김빈희;공승현
    • 전자공학회논문지
    • /
    • 제50권3호
    • /
    • pp.212-218
    • /
    • 2013
  • 본 논문에서는 SAR (Synthetic Aperture Radar) 영상에 SVD (Singular Value Decomposition) - Pseudo Spectrum 알고리즘을 적용하고 그 성능을 기존 알고리즘과 비교한다. 이 논문의 목적은 SAR 영상의 해상도 및 목표물 분해능을 높이고자 하는 것이다. 본 논문에서는 신호 성분으로 이루어진 Hankel Matrix와 SVD (Singular Value Decomposition) 방법을 사용하여 잡음에 강인하고 sidelobe이 적으며 스펙트럼 추정에서 해상도를 높인 SVD-Pseudo Spectrum 방법을 제안하였다. 또한 분해될 목표물을 모델링하여 알고리즘의 성능을 분석하고 SVD-Pseudo Spectrum 방법이 기존의 퓨리에 변환 기반 방법과 고해상도 기술 기반의 MUSIC 방법보다 더 좋은 성능을 가짐을 보인다.

KOMSAR를 이용한 실제 항공기 ISAR 영상 제작 (ISAR Imaging of a Real Aircraft Using KOMSAR)

  • 김경태;정호령
    • 한국전자파학회논문지
    • /
    • 제18권7호
    • /
    • pp.717-722
    • /
    • 2007
  • 표적에 대한 레이더 영상 중의 하나인 ISAR(Inverse Synthetic Aperture Radar) 영상은 표적에 대한 전자파 산란 특성에 대한 2차원 공간 분포를 나타낸다. 이러한 ISAR 영상은 원거리에서 레이더를 이용한 표적 식별에 주로 사용된다. 본 논문에서는 움직이는 실제 항공기에 대한 ISAR 영상을 얻기 위하여, 국방과학연구소에서 제작 및 운용하고 있는 KOMSAR(Korea Miniature Synthetic Aperture Radar) 장비를 이용하여 측정을 수행하였다 이렇게 얻어진 측정된 데이터에 포함되어 있는 표적의 움직임에 의한 위상 오차를 제거하기 위하여, 엔트로피 기반 ISAR 자동 초점 기법(autofocusing technique)을 사용하였다. 실험 결과, 실제 움직이는 항공기에 대한 ISAR 영상을 성공적으로 얻을 수 있었으며, 이는 향후 레이더를 이용한 표적식별에 중요한 기술적 토대가 마련되었음을 의미한다.

EIT imaging with the projection filter

  • Kim, Bong-Seok;Kim, Min-Chan;Kim, Sin;Kim, Kyung-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.396-401
    • /
    • 2003
  • Electrical impedance tomography(EIT) is a relatively new imaging modality in which the internal impedivity distribution is reconstructed based on the known sets of injected currents and measured voltages on the surface of the object. In this paper, an effective dynamic EIT imaging scheme is presented based on the projection filtering to estimate the unknown resistivity distribution. In particular, pre-integration (pre-grouping) technique is employed to stabilize the inverse algorithm. We carried out computer simulations with synthetic data to illustrate the reconstruction performance of the proposed algorithm.

  • PDF

Tucker Modeling based Kronecker Constrained Block Sparse Algorithm

  • Zhang, Tingping;Fan, Shangang;Li, Yunyi;Gui, Guan;Ji, Yimu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권2호
    • /
    • pp.657-667
    • /
    • 2019
  • This paper studies synthetic aperture radar (SAR) imaging problem which the scatterers are often distributed in block sparse pattern. To exploiting the sparse geometrical feature, a Kronecker constrained SAR imaging algorithm is proposed by combining the block sparse characteristics with the multiway sparse reconstruction framework with Tucker modeling. We validate the proposed algorithm via real data and it shows that the our algorithm can achieve better accuracy and convergence than the reference methods even in the demanding environment. Meanwhile, the complexity is smaller than that of the existing methods. The simulation experiments confirmed the effectiveness of the algorithm as well.

APPLICATION OF THE BIFOCUSING METHOD IN MICROWAVE IMAGING WITHOUT BACKGROUND INFORMATION

  • SEONG-HO SON;WON-KWANG PARK
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제27권2호
    • /
    • pp.109-122
    • /
    • 2023
  • In this study, we consider the application of the bifocusing method (BFM) for identifying the locations and shapes of small anomalies from scattering parameter data when the exact values of background permittivity and conductivity are unknown. To this end, an imaging function using numerical focusing operator is introduced and its mathematical structure is revealed by establishing a relationship with an infinite series of Bessel functions, antenna arrangements, and anomaly properties. On the basis of the revealed structure, we demonstrate why inaccurate location and size of anomalies were retrieved via the BFM. Some simulation results are illustrated using synthetic data polluted by random noise to support the theoretical result.

Synthetic Approach to 99mTc-labeled SPECT Radiotracers with Multi-nitroimidazoles for Hypoxia

  • Anh Thu Nguyen;Hee-Kwon Kim
    • 핵의학기술
    • /
    • 제28권1호
    • /
    • pp.1-11
    • /
    • 2024
  • Hypoxia, defined as the deficiency of oxygen, is a significant hallmark of cancers presenting in the majority of solid tumors. Detection of tumor hypoxia is essential in cancer diagnosis to prevent cancer progression, metastasis, and resistance to cancer therapies in clinical practices. Single-photon emission computed tomography (SPECT) is one of the methods studied and applied for hypoxia detection with the use of radiolabeled imaging agents in which 99mTc is the common radioisotope used for radiolabeling. Nitroimidazoles are the hypoxia-targeting moieties presenting in numerous 99mTc-radiolabeled imaging agents due to their bio-reducible ability in hypoxic environments. Recently, in addition to 99mTc-labeled radiopharmaceuticals containing one nitroimidazole unit, there has been considerable attention given to 99mTc-radiopharmaceuticals bearing two or more nitroimidazole units. This review summarizes the synthesis of hypoxia-targeting chelators and radiolabeling processes to produce these 99mTc-radiopharmaceuticals for SPECT imaging.

Synthesis of Novel 18F-Labeled-Nitroimidazole-Based Imaging Agents for Hypoxia: Recent Advances

  • Anh Thu Nguyen;Hee-Kwon Kim
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.83-93
    • /
    • 2023
  • Hypoxia indicates the condition of low oxygen levels in tissues. In oncology, hypoxia can induce cancer progression and metastasis, as well as cause resistance to cancer therapies. The detection of hypoxia by using molecular imaging, particularly, positron emission tomography (PET) has been extensively studied due to many advantages. Nitroimidazoles, the moieties that can be trapped in hypoxic tissues due to selective reduction, have been used to design and synthesize of hypoxia-targeting radiopharmaceuticals. This review provides a summary of synthetic routes towards 18F-labeled-nitroimidazole radiotracers for PET imaging of hypoxia.

RMA를 이용한 Spotlight SAR 영상형성 및 품질평가를 위한 시뮬레이터 개발 및 구현 (Development and application of simulator for spotlight SAR image formation and quality assesment using RMA)

  • 곽준영
    • 한국항공우주학회지
    • /
    • 제39권2호
    • /
    • pp.183-194
    • /
    • 2011
  • 합성 개구면 레이다(SAR: synthetic aperture radar)는 날씨 및 주/야간에 관계없이 고해상도의 영상을 형성할 수 있기 때문에 다양한 분야에서 활용되고 있다. 본 논문에서는 영상 형상 및 품질 평가, 분석을 위한 Spotlight SAR 시뮬레이터를 제안한다. SAR 영상 품질의 예측은 초기 개념 설계 단계부터 최종적인 비행 검증 및 보정 단계에 걸쳐 필수적이다. 제안된 SAR 시뮬레이터는 시스템 설계 변수들에 기반을 두고 있어 전체 시스템 개발과정에서 SAR 영상의 품질을 예측 분석할 수 있다. 이를 위해 영상 획득 기하구조와 다양한 SAR 시스템 설계변수들을 고려하여 이상적인 점표적에 대한 시뮬레이션 원시 데이터를 생성하고 Spotlight 영상 형성 알고리듬을 구현함으로서 점표적 응답특성을 추정한다. 마지막으로 공간 해상도, 최대 부엽 수준, 누적 부엽 수준 등의 주요 품질변수들을 중심으로 생성된 원시 데이터의 영상 품질을 분석한다.

소나 플랫폼의 운동 파라미터에 따른 합성개구소나 영상 왜곡의 정량적 분석 (A quantitative analysis of synthetic aperture sonar image distortion according to sonar platform motion parameters)

  • 김시문;변성훈
    • 한국음향학회지
    • /
    • 제40권4호
    • /
    • pp.382-390
    • /
    • 2021
  • 해저면 영상을 취득하기 위해 측면주사소나나 다중빔측심기 외에도 합성개구소나가 상용화되어 널리 사용되고 있으며 국내에서도 예인형 시스템 개발 등 관련 연구가 진행 중에 있다. 고해상도의 합성개구소나 영상을 얻기 위해서는 이를 탑재하고 있는 플랫폼의 운동을 정확하게 추정하는 것이 필요하며 이를 위해 정밀한 수중항법 시스템이 요구되고 있다. 본 논문에서는 합성개구소나를 탑재하고 있는 플랫폼의 운동 특성에 따라 소나 영상의 왜곡이 얼마나 발생하는지 정량적으로 분석함으로써 요구되는 항법 정확도와 항법센서의 정밀도를 설정하는데 있어서 기준이 되는 자료를 제공하고자 한다. 총 다섯가지의 운동을 고려하고 있으며 정량적 분석을 위해 정규화된 평균 제곱근 오차를 정의한다. 각 운동 특성의 변수값 변화에 따른 오차 분석 수치해석을 통해 yaw and sway 운동이 가장 큰 영상 왜곡을 야기하며 pitch and heave 운동의 영향은 크지 않음을 확인하였다.