• Title/Summary/Keyword: Synthetic graft

Search Result 85, Processing Time 0.021 seconds

Successful strategy of treatment using rhBMP-2 for maxillary sinus graft (rhBMP-2를 이용한 상악동거상술의 성공적인 치료 전략)

  • Kim, Hyoun Chull;Kim, Soo Nam;Lee, Jang Yeol;Kim, Uk Cheon
    • The Journal of the Korean dental association
    • /
    • v.53 no.1
    • /
    • pp.14-27
    • /
    • 2015
  • BMPs are multi-functional growth factors which are members of the transforming growth factor-beta super family and their ability is that plays a pivotal roll in inducing bone. About 18 BMP family members have been identified and characterized. Among of them, BMP-2 and BMP-7 have significant importance in bone development. In this case reports, patients of maxillary sinus graft were received who visited LivingWell Dental Hospital. We focused on the results of the surgical intervention. We suggest that new strategy of treatment used to rhBMP-2 and ${\beta}$-TCP scaffold for patients of sinus graft. The purpose of this paper is to give a brief overview of BMPs and to critically review the clinical data currently available on rhBMP-2 and synthetic bone scaffold.

Correction of Lower Eyelid Retraction with Autogenous Hard Palate Mucosa: 2 Case Report (자가 경구개점막 이식을 이용한 하안검 퇴축의 교정: 2례 보고)

  • Kim, Jino;Seul, Chul Hwan;Roh, Tae Suk;Yoo, Woon Min
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.499-502
    • /
    • 2006
  • Purpose: Grave's disease is an autoimmune disease with chronic and systemic features. It affects the orbital fat and muscle bringing about defect in extrinsic eye motility, diplopia, optic nerve defect and lid retraction. In patients with lagopthalmos and resulting facial deformity, treatment can be done by rectus muscle recession or filling with various material. Autogenous auricular cartilage graft is often used and synthetic material such as synthetic acellular dermis, polyethylene meshs are also used for filling of the depressed area. Nevertheless, autogenous auricular cartilage grafts are difficult to utilize and synthetic materials sometimes result in protrusion or infection. Therefore, hard palate mucosa was considered as an alternative. We report two cases of patients with lower eyelid retraction corrected with autogenous hard palate mucosa. Methods: We performed this operation in two patients of Graves' ophthalmopathy. The capsulopalpebral fascia was incised and elevated through an incision on the conjunctiva. Then, the harvested hard palate mucosa was sutured to the inferior border of the tarsus and covered with the conjunctiva. Results: The lower eyelid retraction was corrected successfully. No hypertrophy or deformation of the transplanted hard palate mucosa was noted 6 months after the surgery. Conclusions: From the results above, we may conclude that the hard palate mucosa serves as an ideal spacer for the curvature and the inner lining in lower lid retraction. Hard palate mucosa is as sturdy as the autogenous cartilage but is much easier to utilize. It can be also used for lid retraction after lower lid aesthetic surgeries or traumas.

Evaluation of the regenerative capacity of stem cells combined with bone graft material and collagen matrix using a rabbit calvarial defect model

  • Jun-Beom Park;InSoo Kim;Won Lee;Heesung Kim
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.467-477
    • /
    • 2023
  • Purpose: The purpose of this study was to evaluate the regenerative capacity of stem cells combined with bone graft material and a collagen matrix in rabbit calvarial defect models according to the type and form of the scaffolds, which included type I collagen matrix and synthetic bone. Methods: Mesenchymal stem cells (MSCs) were obtained from the periosteum of participants. Four symmetrical 6-mm-diameter circular defects were made in New Zealand white rabbits using a trephine drill. The defects were grafted with (1) group 1: synthetic bone (β-tricalcium phosphate/hydroxyapatite [β-TCP/HA]) and 1×105 MSCs; (2) group 2: collagen matrix and 1×105 MSCs; (3) group 3: β-TCP/HA, collagen matrix covering β-TCP/HA, and 1×105 MSCs; or (4) group 4: β-TCP/HA, chipped collagen matrix mixed with β-TCP/HA, and 1×105 MSCs. Cellular viability and cell migration rates were analyzed. Results: Uneventful healing was achieved in all areas where the defects were made at 4 weeks, and no signs of infection were identified during the healing period or at the time of retrieval. New bone formation was more evident in groups 3 and 4 than in the other groups. A densitometric analysis of the calvarium at 8 weeks post-surgery showed the highest values in group 3. Conclusions: This study showed that the highest regeneration was found when the stem cells were applied to synthetic bone along with a collagen matrix.

Clinical and Radiological Outcomes of Anterior Cervical Interbody Fusion Using Hydroxyapatite Spacer

  • Kim, Sung-Chul;Kang, Sung-Won;Kim, Se-Hyuk;Cho, Ki-Hong;Kim, Sang-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.300-304
    • /
    • 2009
  • Objective : This is retrospective study of clinical and radiological outcomes of anterior cervical fusion using Bongros-$HA^{TM}$ (BioAlpha, Seongnam, Korea) which is a type of synthetic hydroxyapatite (HA) spacer to evaluate the efficacy in its clinical application and usefulness as a reliable alternative to autograft bone. Methods : Twenty-nine patients were enrolled in this study and 40 segments were involved. All patients were performed anterior cervical interbody fusion using HA spacer and plating system. Indications for surgery were radiculopathy caused by soft-disc herniation or spondylosis in 18 patients, spondylotic myelopathy in 1 patient, and spinal trauma in 10 patients. Cervical spine radiographs were obtained on postoperative 1day, 1week, and then at 1, 2, 6, and 12 months in all patients to evaluate intervertebral disc height, and the degrees of lordosis. Cervical computed tomography was done at postoperative 12 month in all patients to confirm the fusion status. The mean period of clinical follow-up was 17 months. Results : Complete interbody fusion was achieved in 100% of patients. Preoperative kyphotic deformities were corrected in all cases after surgery. Intervertebral disc height was well maintained during follow up period. There were no cases of graft extrusion, graft deterioration and graft fracture. Conclusion : HA spacer is very efficient in achieving cervical fusion, maintaining intervertebral disc height, and restoring lordosis. When combined with the placement of a cervical plate, immediate stability can be achieved and graft related complication can be prevented.

Study on the controlled preparation of polyolefin based block or graft copolymers (폴리올레핀 기반 블록 또는 그라프트 공중합체의 정밀 제조에 대한 고찰)

  • Lee, Jong Heon;Hong, Sung Chul
    • Elastomers and Composites
    • /
    • v.48 no.1
    • /
    • pp.30-38
    • /
    • 2013
  • Polyolefin is one of the most important commodity polymers having excellent physical properties and cost competitiveness, which has continuously broadened their market in response to a heavy demand from industry. However, the lack of polarity in polyolefin has limited its applications, especially where interactions with other materials are important. In view of the above, the incorporation of polar functional groups in polyolefin has been widely attempted. Especially, the preparations of segmented modified polyolefin copolymers, such as block and graft copolymers have been extensively investigated, since the loss of the original properties of polyolefin can be minimized while the polar segments can endow interactions with other materials. Living radical polymerization (LRP) method can be one of the most attractive synthetic tools for the preparation of the modified polyolefin block or graft copolymers. In this review, progress on the preparation of the polyolefin based block or graft copolymers through LRP technique is briefly summarized.

Aortoenteric Fistula - A Report of a Case - (대동맥장루 -1예 보고-)

  • 김성수
    • Journal of Chest Surgery
    • /
    • v.22 no.5
    • /
    • pp.823-828
    • /
    • 1989
  • Aortoenteric fistula is an uncommon important complication of aortic reconstruction with a prosthetic graft. The complication often is difficult to diagnose and is associated with poor prognosis. Aortoenteric fistula could be divided into true aortoenteric fistula and paraprosthetic-enteric fistula. In case of true aortoenteric fistula, an actual communication between the gastrointestinal tract and the aortic lumen is present. So, massive gastrointestinal hemorrhage is the presenting manifestation. In paraprosthetic-enteric fistula, characterized by communication between the gastrointestinal tract and the external surface of synthetic vascular prosthesis without actual fistularization into the vascular lumen, the predominant clinical manifestation were sepsis, fever and anemia. We experienced one case of paraprosthetic-enteric fistula in a 16 years old male after abdominal aortic reconstruction with a prosthetic graft. The interval from the operation to onset of symptoms was 40 months. The initial clinical manifestation was sepsis, fever and anemia without massive gastrointestinal hemorrhage. Surgical treatment consists of complete excision of infected graft, two layers closure of jejunal wall defect and pledgets suture of aortic stump with surrounding health tissue. Anatomic revascularization was not able to be done: because of extensive retroperitoneal inflammation and extraanatomic revascularization did not performed due to adequate distal blood supply through rich collateral circulation. After operation, he complained numbness on left foot on moderate exertion and felt coldness on left leg compared with right leg but not showed skin color change. 43 days after operation, he discharged without gait disturbance except numbness on left foot on moderate exertion.

  • PDF

Giant Popliteal Artery Aneurysm in a Teenager: An Unusual Occurrence

  • Jadhav, Sanjeev;Sanagar, Sachin;Kaushik, Shantesh;Munde, Haridas
    • Journal of Chest Surgery
    • /
    • v.52 no.2
    • /
    • pp.116-118
    • /
    • 2019
  • Giant popliteal artery aneurysm is an uncommon entity. If untreated, it results in life-threatening complications. It is usually seen in older patients (over 60 years of age), and atherosclerotic disease is its main cause. Few cases have been reported in young adults, and its incidence in teenagers is exceptionally rare, with scarce case reports in the literature. We report a case of left popliteal artery aneurysm in a 16-year-old and its successful surgical treatment through resection and repair with a synthetic interposition graft.

Synthesis of Multi Hydroxyl Chain-End Functionalized Polyolefin Elastomer with Poly(t-butylstyrene) Graft (Poly(t-butylstyrene) 그라프트를 가지는 수산기 말단 관능화 폴리올레핀 탄성체의 합성)

  • Lee, Hyoung Woo;Cho, Hee Won;Lee, Sang Min;Park, Sat Byeol;Kim, Dong Hyun;Lee, Bum Jae
    • Elastomers and Composites
    • /
    • v.48 no.1
    • /
    • pp.10-17
    • /
    • 2013
  • Polyolefin-g-poly(t-butylstyrene) as one of the high-temperature polyolefin-based thermoplastic elastomers was synthesized by the graft-from anionic living polymerization from the styrene moieties of the linear poly(ethylene-ter-1-hexene-ter-divinylbenzene) as a soft block to form the hard end blocks, poly(t-butylstyrene). The chemistry of the anionic graft-from polymerization involved complete lithiation of the pendant styrene unit of the soft polyolefin elastomer with sec-BuLi/TMEDA followed by the subsequent graft anionic polymerization of 4-tert-butylstyrene with Mn=10,000~30,000 g/mol. The graft-from living anionic polymerization were very effective and the grafting size increased proportionally with increasing monomer concentration and the reaction times. The synthetic methodology for the multi-hydroxyl chain-end modified polyolefin-g-poly(t-butylstyrene) was proposed by using the thiol-ene click reaction between 2-mercaptoethanol and the polyolefin-g-[poly(t-butylstyrene)-b-high vinyl polyisoprene], which was obtained from the subsequent living block copolymerization using polyolefin-g-Poly(t-butylstyrene) with isoprene. The result indicated that this process produced a new well-defined functionalized graft-type polyolefin-based TPE with high $T_g$ hard block(> $145^{\circ}C$).

A study of the clinical effects of various bone graft materials (다양한 골 이식재의 임상 효과에 대한 고찰)

  • Lee, Seung-Bum;Yon, Je-Young;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Geun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.719-732
    • /
    • 2007
  • Purpose: Various bone graft materials are being used for periodontal tissue regeneration. Th materials are being developed continuously for ideal clinical effects. Therefore, it is necessary to identify the clinical characteristics of each bone graft material through comparing the various bone graft materials statistically and in doing so, proposing a more efficient bone graft material. In this study, the following results were attained through comparing the clinical effects among the bone graft materials, using the statistical method based on the clinical studies published at the department of periodontology of Yonsei hospital. Materials and Method: 6 selected studies of department of Periodontology at Yonsei University Hospital were based on clinical study of bone grafting in intrabony defects. It was compared the clinical parameters among the 6 clinical studies, using the statistical META analysis. Result: When comparing the probing depth reduction, there was a relatively great amount of decease when using the xenograft, Anorganic Bovine Derived Hydroxapatite Bone Matrix/Cell Binding Peptide(ABM/P-15: PepGen $P-15^{(R)}$) and the autogenous bone and absorbable membrane, d, 1-alctide/glycolide copolymer(GC: $Biomesh^{(R)}$). The allogfrafts showed a relatively low decrease in the probing depth and clinical attachment change. It also showed a slight decrease in the bone probing depth. The allografts showed various results according to different bone graft materials. When comparing the ABM/P-15 and bovine bone $powder(BBP^{(R)})$, ABM/P-15 showed a relatively high clinical attachment level and the bovine bone powder showed a relatively high clinical attachment level. The probing depth change and gingival recession change showed a lower value than the mean value between the two bone graft materials. The synthetic bone showed a relatively high decrease in clinical attachment level and periodontal probing depth change. There was a relatively larger amount of gingival recession when using Bioactive Glass(BG) but a relatively low bone regeneration effect was seen. Conclusion: Good restorative results of the periodontal tissue can be attained by applying the various bone graft materials being used today after identifying the accurate clinical effects.

Research trends and Efficacy Analysis of Surface Characteristics of Bone Grafts (골이식재의 표면 특성 연구 동향과 유효성 분석)

  • Yong-Hoon Jeong;Gye-Wook Lee;Tae-Gon Jung
    • Journal of the Korean institute of surface engineering
    • /
    • v.57 no.4
    • /
    • pp.234-253
    • /
    • 2024
  • As the population ages, the importance of effective bone disease treatments is increasing, highlighting the role of bone grafts. Bone grafts are categorized into natural (autografts, allografts, xenografts) and synthetic (ceramics, polymers). Natural grafts have excellent regenerative abilities but pose biological risks, while synthetic grafts are biocompatible but less effective in regeneration. Various studies aim to enhance the safety and efficacy of bone grafts, significantly altering their surface properties. This review examines these studies and the resulting surface changes, aiming to guide future research and clinical applications.