• Title/Summary/Keyword: Synthetic Spectrum

Search Result 160, Processing Time 0.026 seconds

Synthetic $\beta$-Lactam Antibiotics IV. Antibacterial activity of some 7 $\beta$-[2-(2-Aminothizol-4-yl)-2-(methoxyimino) acetaido]-3-(1-alkyl-1H-terazol-5-yl)thiomethyl-cephalospoins

  • Lee, Duck-Hyung;Kim, Sam-Min;Park, Sang-Woo;Kim, You-Seung
    • Archives of Pharmacal Research
    • /
    • v.13 no.4
    • /
    • pp.385-387
    • /
    • 1990
  • 3-[(1-Methyl-1H-tetrazol-5-y)thiomethyl] is one of the most important side chains in cephaloporins. This side chain which occures in numerous antibacterial agents, suc as cefamandole, latamoxef, cefoperazone, and cefmenoxime, contributes remarkable potency and broad spectrum. For the continuous work of study on the development of broad spectrum cephalosporins, we become interested in the effect of structural modification of the substituent at the N-1 position of mercaptoterazole toward biological activity because our recent work had demonstraated that the arylsubstituted mercaptotetrazoles (Fig. 1) had favorable effect on the activity against gram-positive bacteria. The main focus of this report was to investigate the relationship between activity and functional groups in the mercaptotetrazole.

  • PDF

A Study on Growth of Smoky Quartz (연수정 육성에 관한 연구)

  • 박로학;유영문
    • Korean Journal of Crystallography
    • /
    • v.1 no.2
    • /
    • pp.61-65
    • /
    • 1990
  • Smoky quartz was grown hydrothermally. For the establishment of the best growth condition, various growth factors, such as nutrients, seed orientations, minerlizers, colorants and irradiation times were studied. By the UV-visible spectrum analysis synthetic and natural smoky quartz were characterized. As a result, smoky quartz of 120mm L X 35mm W X 14mm T with clear color tone and minimum defect was grown.

  • PDF

Microstructure, Electrical Property and Nonstoichiometry of Light Enhanced Plating(LEP) Ferrite Film

  • 김 돈;이충섭;김영일
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.5
    • /
    • pp.533-539
    • /
    • 1998
  • A magnetic film was deposited on a slide glass substrate from aqueous solutions of $FeCl_2$ and $NaNO_2$ at 363 K. XRD analysis showed that the film was polycrystalline magnetite $(Fe_{3(1-{\sigma})}O_4)$ without impurity phase. The lattice constant was 0.8390 nm. Mossbauer spectrum of the film could be deconvoluted by the following parameters: isomer shifts for tetrahedral $(T_d)$ and octahedral $(O_h)$ sites are 0.28 and 0.68 mm/s, respectively, and corresponding magnetic hyperfine fields are 490 and 458 kOe, respectively. The estimated chemical formula of the film by the peak intensity of Mossbauer spectrum was $Fe_{2.95}O_4$. Low temperature transition of the magnetite (Verwey transition) was not detected in resistivity measurement of the film. Properties of the film were discussed with those of pressed pellet and single crystal of synthetic magnetites. On the surface of the film, magnetite particles of about 0.2 μm in diameter were identified by noncontact atomic force microscopy (NAFM) and magnetic force microscopy (MFM).

Heart Sound Localization in Respiratory Sounds Based on Singular Spectrum Analysis and Frequency Features

  • Molaie, Malihe;Moradi, Mohammad Hassan
    • ETRI Journal
    • /
    • v.37 no.4
    • /
    • pp.824-832
    • /
    • 2015
  • Heart sounds are the main obstacle in lung sound analysis. To tackle this obstacle, we propose a diagnosis algorithm that uses singular spectrum analysis (SSA) and frequency features of heart and lung sounds. In particular, we introduce a frequency coefficient that shows the frequency difference between heart and lung sounds. The proposed algorithm is applied to a synthetic mixture of heart and lung sounds. The results show that heart sounds can be extracted successfully and localizations for the first and second heart sounds are remarkably performed. An error analysis of the localization results shows that the proposed algorithm has fewer errors compared to the SSA method, which is one of the most powerful methods in the localization of heart sounds. The presented algorithm is also applied in the cases of recorded respiratory sounds from the chest walls of five healthy subjects. The efficiency of the algorithm in extracting heart sounds from the recorded breathing sounds is verified with power spectral density evaluations and listening. Most studies have used only normal respiratory sounds, whereas we additionally use abnormal breathing sounds to validate the strength of our achievements.

Design response spectra-compliant real and synthetic GMS for seismic analysis of seismically isolated nuclear reactor containment building

  • Ali, Ahmer;Abu-Hayah, Nadin;Kim, Dookie;Cho, Sung Gook
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.825-837
    • /
    • 2017
  • Due to the severe impacts of recent earthquakes, the use of seismic isolation is paramount for the safety of nuclear structures. The diversity observed in seismic events demands ongoing research to analyze the devastating attributes involved, and hence to enhance the sustainability of base-isolated nuclear power plants. This study reports the seismic performance of a seismically-isolated nuclear reactor containment building (NRCB) under strong short-period ground motions (SPGMs) and long-period ground motions (LPGMs). The United States Nuclear Regulatory Commission-based design response spectrum for the seismic design of nuclear power plants is stipulated as the reference spectrum for ground motion selection. Within the period range(s) of interest, the spectral matching of selected records with the target spectrum is ensured using the spectral-compatibility approach. NRC-compliant SPGMs and LPGMs from the mega-thrust Tohoku earthquake are used to obtain the structural response of the base-isolated NRCB. To account for the lack of earthquakes in low-to-moderate seismicity zones and the gap in the artificial synthesis of long-period records, wavelet-decomposition based autoregressive moving average modeling for artificial generation of real ground motions is performed. Based on analysis results from real and simulated SPGMs versus LPGMs, the performance of NRCBs is discussed with suggestions for future research and seismic provisions.

Analysis of Plant Hormones using GC-MS (GC-MS를 이용한 식물홀몬 분석)

  • 조광연
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.s01
    • /
    • pp.26-32
    • /
    • 1989
  • The analytic principles of GC and MS were explained in relation to plant hormone analyses and the characteristics of two instruments were compared. The selection of column, condition of measurement and the method of ionization to get a good spectrum were also briefly described. Finally, the pre-treatment of sample by solvent extraction method to remove the unnecessary part of sample and the synthetic method, especially reagents and reaction condition, for the preparation of ether or ester derivative which can be easily vaporized in GC were explained.

  • PDF

The identification of amethyst origins by using FT-IR, UV-VIS spectrum analysis (ET-IR, UV-VIS 분광분석을 통한 자수정의 산지감별)

  • Yoon Si-Nae;Yon Seog-Joo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.1
    • /
    • pp.25-31
    • /
    • 2006
  • Many amethysts of different origins such as South America, Aftrica, and Asia were compared. According to ICP-AES analysis, the colorizing elements were Fe, Cr, Cu, and Co. Amethysts from South America showed higher concentrations of the elements. UV- VIS analysis showed that both natural and synthetic amethysts were characterized by the higher absorption at 350 nm and 550 nm wavelength. The natural amethysts had lower permeability than that of the synthetic amethysts. According to FT-IR analysis, the synthetic amethysts were distinguished from the natural amethysts in that they had a typical absorption band of $3543cm^{-1}$. The amethyst from South America showed strong absorption bands of $3584cm^{-1}\;and\;3435cm^{-1}$, and African amethyst had absorption bands of $3299cm^{-1}\;and\;3196cm^{-1}$. $3381cm^{-1}$ absorption band was shown strongly for Asian origins.

EXTRACTION OF INTERPRETIVE WAVELETS BY MODIFIED WIENER FILTER METHOD - TEST AND EVALUATION WITH MARINE SESMIIC DATA- (修正 위너필터 方法에 依한 解釋波의 抽出 -海洋彈性波 探査資料에 依한 實驗 및 評價)

  • Youn, Oong Koo;Han, Sang-Joon;Park, Byung Kwon
    • 한국해양학회지
    • /
    • v.18 no.2
    • /
    • pp.117-124
    • /
    • 1983
  • Pizza's synthetic model, a modified Wiener filter method, was tested to establish the procedure of desirable interpretive wavelet extraction and its application to the marine seismic exploration using several approaches with a real offshore seismic data of the southeast Asia. Noise spectrum acquisition is difficult and any assumptions for it do not produce interpretive wavelets as good as synthetic model result by Piazza (1979). however the resolution could be improved with spiking deconvoultion and following zero phase bandpass filter, and the testing procedure and evaluatttion of results can hopefully contribute in future study and practical evaluation of Piazza's method.

  • PDF

Design of a Low Bit-rate Speech Coder Based on Mixed Multi-band Excitation Model (혼합 다중대역 여기모델에 기반한 저 전송률 음성 부호화기의 설계)

  • 한우진;오영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.6
    • /
    • pp.510-521
    • /
    • 2002
  • MBE (multi-band excitation) coder can achieve high qualify synthetic speech below 4.0 kbps. There are, however, significant differences of the fine structure between the original spectrum and the synthetic spectrum. They are mainly due to the exclusive partition of voiced and unvoiced regions in frequency domain and the decision procedure based on the experimental threshold. This paper proposes MMBE (mixed multi-band excitation) speech model to overcome drawbacks of a MBE coder. In addition, two analysis methods, which do not need my decision procedure based on a threshold, are presented. Both voiced and unvoiced components can be mixed over all the frequency axis in the MMBE speech model. To illustrate the potential of the proposed speech model, we develop a 2.6 kbps MMBE coder and compare it with a 2.9 kbps MBE coder by both objective and subjective methods. The results have shown that the proposed coder has a better performance even at a lower bit-rate compared with the MBE coder.

Toxicity of doxycycline, a broad-spectrum semi-synthetic antibiotic, in Pacific whiteleg shrimp (Litopenaeus vannamei) (흰다리새우(Litopenaeus vannamei)에서 광범위 반합성 항생제 doxycycline의 독성연구)

  • Lee, Chae Won;Bae, Jun Sung;Yang, Chan Yeong;Jeoung, Eun Ha;Lee, Ji-Hoon;Park, Kwan Ha
    • Journal of fish pathology
    • /
    • v.33 no.1
    • /
    • pp.45-53
    • /
    • 2020
  • Doxycycline is a semi-synthetic broad-spectrum antibiotic, and it has been used to get rid of bacteria in animals and humans. The use of antibiotics has greatly contributed to the aquaculture production although its misuse sometimes presents public health problems. This study was performed to investigate the toxic effects of doxycycline on whiteleg shrimp (Litopenaeus vannamei) administered for possible infection treatments. The shrimp were allocated into four groups and doxycycline was fed three times a day for 7 days at 0, 20, 50 and 100 mg/kg to each group. After 24 hr following the 7-day treatment, hemolymph and hepatopancreas were used for blood and biochemical analysis: Total hemocyte counts, Total protein, Total cholesterol, Gluscose, Glutamic pyruvic transaminase, Glutamic oxaloacetic transaminase, Glutathione peroxidase, Superoxide dismutase, Glutathione-s-transferases, Total antioxidant capacity colorimetric and Acid phosphatase. In addition, histopathological examination was performed on the hepatopancreas and muscle. It was observed that body weight gain was significantly retarded in 100 mg/kg doxycycline group. Doxycycline was found to induce biochemical or functional disorders at 100 mg/kg as observed many of the blood and biochemical parameters were significantly reduced. In conclusion, it was judged that there will be no major toxicity problems with doxycycline when used for shrimp aquaculture at regular doses.