Optimal Reserve Allocation to Maximize Kinetic Energy in a Wind Power Plant

  • Yoon, Gihwan;Lee, Hyewon;Lee, Jinsik;Yoon, Gi-Gab;Park, Jong Keun;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.1950-1957
    • /
    • 2015
  • Modern wind generators (WGs) are forced or encouraged to participate in frequency control in the form of inertial and/or primary control to improve the frequency stability of power systems. To participate in primary control, WGs should perform deloaded operation that maintains reserve power using speed and/or pitch-angle control. This paper proposes an optimization formulation that allocates the required reserve to WGs to maximize the kinetic energy (KE) stored in a wind power plant (WPP). The proposed optimization formulation considers the rotor speed margin of each WG to the maximum speed limit, which is different from each other because of the wake effects in a WPP. As a result, the proposed formulation allows a WG with a lower rotor speed to retain more KE in the WPP. The performance of the proposed formulation was investigated in a 100-MW WPP consisting of 20 units of 5-MW permanent magnet synchronous generators using an EMTP-RV simulator. The results show that the proposed formulation retains the maximum amount of KE with the same reserve and successfully increases the frequency nadir in a power system by releasing the stored KE in a WPP in the case of a disturbance.

HAI 제어기반 SV PWM 방식을 이용하나 IPMSM의 고성능 제어 (High Performance Control of IPMSM using SV-PWM Method Based on HAI Controller)

  • 최정식;고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제23권8호
    • /
    • pp.33-40
    • /
    • 2009
  • 본 논문에서는 HAI(Hybrid Artificial Intelligent) 제어기반의 SV PWM 방식을 이용한 IPMSM의 고성능 제어를 제시한다. HAI 제어기는 적응 퍼지제어 및 신경회로망의 장점을 혼합 적용한다. SV PWM 방식은 지금까지 산업용 전동기 제어분야에 적용되고 있고 출력전류의 고조파 비율, 스위칭 주파수 및 응답특성을 향상시키는 수 있는 기법이다. HAI 제어기는 지령전압을 계산할 때 발생되는 문제점을 해결하기 위하여 종래의 PI 제어기를 대체하여 사용한다. HAI 제어기는 지령모델 기반의 적응제어, 퍼지제어 및 신경회로망으로 구성되어 속도 성능을 개선한다. 본 논문에서는 제시한 HAI 제어기를 적용하여 파라미터 변동, 정상상태 및 과도상태 등의 응답특성을 분석하고 종래의 FNN 제어기 및 PI 제어기의 응답특성과 비교한다. 따라서 본 논문에서는 HAI 제어기의 타당성을 입증한다.

반복 적응자속관측기를 이용한 초고속 영구자석형 동기전동기의 전영역 센서리스 제어 (Sensorless Control of High-speed Type PMSM in Wide Speed Range using an Iterative Adaptive Flux Observer)

  • 김종무;최정원;이석규
    • 전력전자학회논문지
    • /
    • 제14권2호
    • /
    • pp.168-175
    • /
    • 2009
  • 본 논문은 에어포일 베어링을 적용한 45,000[rpm]/22[kW]급 초고속 영구자석형 동기전동기의 센서리스 제어을 위한 개선된 알고리즘을 제안한다. 에어포일 베어링이 적용된 전동기를 정지상태에서 초기 기동시 부터 고속영역까지 전 속도 영역에 걸쳐 센서리스 알고리즘을 구현하기 위하여 반복 적응자속관측기를 제안하여 회전자의 회전각 및 속도를 실시간으로 추정하여 센서리스 제어 알고리즘을 구현하였다. 기존 적응자속관측기의 주파수 응답특성을 개선하고 넓은 속도 범위에서 안정된 응답을 얻기 위하여 속도에 따른 회전자의 추정 위치각과 실제 회전각과의 오차를 시뮬레이션을 통하여 분석한 후 안정된 위상지연 특성을 나타내는 반복 횟수를 얻고 전류제어 주기 내에서 관측기를 반복 수행하여 적응자속관측기의 동특성 성능을 개선하는 알고리즘을 제안하였다. 또한 제안된 반복 적응 자속관측기를 적용한 센서리스 알고리즘의 타당성을 입증하기 위하여 실험을 통하여 검증하였다.

전압원인버터를 이용한 계통연계형 풍력발전의 출력제어 모의 및 해석 (Modeling and Analysis of Control Scheme for Voltage Source Inverter Based Grid-connection of Wind Turbine)

  • 김슬기;김응상
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.154-163
    • /
    • 2003
  • 전력계통에 연계하기 위해서 풍력발전시스템은 계속해서 변하는 풍속에 응동하여 적정한 출력을 계통에 공급할 수 있을 뿐만 아니라, 연계되는 전력계통에서 허용될 수 있는 수준의 주파수와 전압크기를 갖는 출력을 제공할 수 있어야 하며, 이를 위해서는 풍력발전의 적절한 출력제어가 필수적으로 요구된다. 본 연구에서는 동기발전기가 전압원인버터로 구성된 AC-DC-AC 변환부를 거쳐 계통에 접속되는 계통연계형 풍력발전시스템의 출력제어 전략을 소개하며, 이를 전자기 과도현상 해석 프로그램인 PSCAD/EMTDC를 이용하여 모의하고 해석하였다. 블레이드를 통해 입력되는 풍속에 대하여 최대 에너지를 공급할 수 있도록 전압원인버터의 유효전력 출력제어가 이루어지며, 출력단 전압을 일정하게 유지하기 위한 무효전력 출력제어가 행해진다. 또한 60 Hz의 주파수 출력 및 고조파 저감을 위해 SPWM 스위칭 방식을 채택하였다. 풍속의 변동 및 부하의 변동에 대한 풍력발전시스템의 응동특성 및 출력변화를 모의하고 해석한다.

3레벨 인버터로 구동되는 IPMSM의 고주파 주입 센서리스 운전에서 중성점 전압 리플 저감 (Neutral-Point Voltage Ripple Reduction of High Frequency Injection Sensorless Control of IPMSM Fed by a Three-Level Inverter)

  • 조대현;김석민;이교범
    • 전기전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.867-876
    • /
    • 2020
  • 본 논문에서는 3레벨 인버터로 구동되는 IPMSM의 고주파 주입 센서리스 운전에서 중성점 전압 리플 저감을 제안한다. 고주파 전압 주입 기반의 센서리스 제어는 IPMSM의 저속 영역에서 일반적으로 사용하는 센서리스 제어 기법이다. 고주파 전압 주입을 이용한 IPMSM의 센서리스 제어 과정에서 중성점에서의 전압 리플이 증가하는 문제가 발생한다. 중성점에서의 큰 전압 리플은 출력 전류를 왜곡시킬 뿐만 아니라 직류단 커패시터의 수명을 단축시키므로 저감되어야 한다. 본 논문에서 제안하는 기법은 지령 전압에 적절한 값을 보상하여 중성점 전압 리플을 저감하며, 보상값은 지령 전압과 전류를 이용하여 간단히 계산한다. 제안하는 중성점 전압 리플 저감 기법의 타당성은 시뮬레이션을 통해 검증한다.

중형 풍력터빈의 출력 및 타워 하중저감 제어기 설계 (Design of Power and Load Reduction Controller for a Medium-Capacity Wind Turbine)

  • 김관수;백인수;김철진;김현규;김형길
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.1-12
    • /
    • 2016
  • A control algorithm for a 100 kW wind turbine is designed in this study. The wind turbine is operating as a variable speed variable pitch (VSVP) status. Also, this wind turbine is a permanent magnet synchronous generator (PMSG) Type. For the medium capacity wind turbine considered in this study, it was found that the optimum tip speed ratios to achieve the maximum power coefficients varied with wind speeds. Therefore a commercial blade element momentum theory and multi-body dynamics based program was implemented to consider the variation of aerodynamic coefficients with respect to Reynolds numbers and to find out the power and thrust coefficients with respect tip speed ratio and blade pitch angles. In the end a basic power controller was designed for below rated, transition and above rated regions, and a load reduction algorithm was designed to reduce tower vibration by the nacelle motion. As a result, damage equivalent Load (DEL) of tower fore-aft has been reduced by 32%. From dynamic simulations in the commercial program, the controller was found to work properly as designed. Experimental validation of the control algorithm will be done in the future.

A Magnetic Energy Recovery Switch Based Terminal Voltage Regulator for the Three-Phase Self-Excited Induction Generators in Renewable Energy Systems

  • Wei, Yewen;Kang, Longyun;Huang, Zhizhen;Li, Zhen;Cheng, Miao miao
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1305-1317
    • /
    • 2015
  • Distributed generation systems (DGSs) have been getting more and more attention in terms of renewable energy use and new generation technologies in the past decades. The self-excited induction generator (SEIG) occupies an important role in the area of energy conversion due to its low cost, robustness and simple control. Unlike synchronous generators, the SEIG has to absorb capacitive reactive power from the outer device aiming to stabilize the terminal voltage at load changes. This paper presents a novel static VAR compensator (SVC) called a magnetic energy recovery switch (MERS) to serve as a voltage controller in SEIG powered DGSs. In addition, many small scale SEIGs, instead of a single large one, are applied and devoted to promote the generation efficiency. To begin with, an expandable mathematic model based on a d-q equivalent circuit is created for parallel SEIGs. The control method of the MERS is further improved with the objective of broadening its operating range and restraining current harmonics by parameter optimization. A hybrid control strategy is developed by taking both of the stand-alone and grid-connected modes into consideration. Then simulation and experiments are carried out in the case of single and double SEIG(s) generation. Finally, the measurement results verify that the proposed DGS with SVC-MERS achieves a better stability and higher feasibility. The major advantages of the mentioned variable reactive power supplier, when compared to the STATCOM, include the adoption of a small DC capacitor, line frequency switching, simple control and less loss.

주파수의 최대 변화율을 이용한 풍력단지 가상관성제어 (Virtual Inertial Control of a Wind Power Plant using the Maximum Rate of Change of Frequency)

  • 김두연;김진호;이진식;김연희;전영환;강용철
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.918-924
    • /
    • 2013
  • In a conventional power system, the frequency is recovered to the nominal value by the inertial, primary, and secondary responses of the synchronous generators (SGs) after a large disturbance such as a generator tripping. For a power system with high wind penetration, the system inertia is significantly reduced due to the maximum power point tracking control based operation of the variable speed wind generators (WGs). This paper proposes a virtual inertial control for a wind power plant (WPP) based on the maximum rate of change of frequency to release more kinetic energy stored in the WGs. The performance of the proposed algorithm is investigated in a model system, which consists of a doubly fed induction generator-based WPP and SGs using an EMTP-RV simulator. The results indicate that the proposed algorithm can improve the frequency nadir after a generator tripping. In addition, the algorithm can lead the instant of a frequency rebound and help frequency recovery after the frequency rebound.

겐트리형 리니어 모터의 동기화를 위한 비선형 적응제어 (Nonlinear Adaptive Control for Position Synchronization of a Gantry-Moving-Type Linear Motor)

  • 한상오;김인근;허건수
    • 대한기계학회논문집A
    • /
    • 제34권12호
    • /
    • pp.1925-1930
    • /
    • 2010
  • 겐트리형 리니어 모터의 주행 축은 동기화가 필수적이며 그렇지 못할 경우에는 위치의 어긋남이나 불안정한 동작으로 인해 동기오차가 발생하며 이는 고속 고정밀 선형운동에 악영향을 미친다. 또한 두 리니어모터의 축은 로터리 모터와 달리 동력 전달장치를 제거함으로 인해 모델의 불확실성이나 외란에 민감할 뿐만 아니라 마찰과 리플의 특성에 쉽게 영향을 받는다. 본 논문은 겐트리형 리니어 모터의 주행 축을 대상으로 위치제어에 악영향을 주는 대표적인 비선형 함수인 마찰력과 리플력을 추정하여 보상하며 두 축간의 동기오차를 줄이기 위해 동기제어 알고리즘을 설계하였다. 제안된 비선형 적응제어기는 모의실험을 통하여 성능을 검증하였다.

Analysis of a Harmonics Neutralized 48-Pulse STATCOM with GTO Based Voltage Source Converters

  • Singh, Bhim;Saha, Radheshyam
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.391-400
    • /
    • 2008
  • Multi-pulse topology of converters using elementary six-pulse GTO - VSC (gate turn off based voltage source converter) operated under fundamental frequency switching (FFS) control is widely adopted in high power rating static synchronous compensators (STATCOM). Practically, a 48-pulse ($6{\times}8$ pulse) configuration is used with the phase angle control algorithm employing proportional and integral (PI) control methodology. These kinds of controllers, for example the ${\pm}80MVAR$ compensator at Inuyama switching station, KEPCO, Japan, employs two stages of magnetics viz. intermediate transformers (as many as VSCs) and a main coupling transformer to minimize harmonics distortion in the line and to achieve a desired operational efficiency. The magnetic circuit needs altogether nine transformers of which eight are phase shifting transformers (PST) used in the intermediate stage, each rating equal to or more than one eighth of the compensator rating, and the other one is the main coupling transformer having a power rating equal to that of the compensator. In this paper, a two-level 48-pulse ${\pm}100MVAR$ STATCOM is proposed where eight, six-pulse GTO-VSC are employed and magnetics is simplified to single-stage using four transformers of which three are PSTs and the other is a normal transformer. Thus, it reduces the magnetics to half of the value needed in the commercially available compensator. By adopting the simple PI-controllers, the model is simulated in a MATLAB environment by SimPowerSystems toolbox for voltage regulation in the transmission system. The simulation results show that the THD levels in line voltage and current are well below the limiting values specified in the IEEE Std 519-1992 for harmonic control in electrical power systems. The controller performance is observed reasonably well during capacitive and inductive modes of operation.