• Title/Summary/Keyword: Synchronous

Search Result 4,121, Processing Time 0.031 seconds

New Implementation Method of the Pulsed Nuclear Magnetic Resonance Apparatus (펄스방식의 핵자기 공명장치에 관한 새로운 구현방법)

  • 김청월
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.1-11
    • /
    • 1998
  • This paper presents a new implementation method of the pulsed NMR(nuclear magnetic resonance) apparatus, which contains a single coil in a magnet console, to detect a NMR signal. Applying an RF magnetic field of 5MHz to the magnet console which is designed to have Larmor frequency of 5MHz for hydrogen atom, the hydrogen NMR signal was obtained from the glycerin which was put in the magnet console as a sample. The DC magnetic field in the magnet console was implemented with a permanent magnet of 1168 gauss and the RF magnetic field was generated appling an RF signal with the frequency of 5MHz and the current magnitude of 8A to a coil of 5.73${\mu}$H. The magnitude of the NMR signal was maximum when the RF magnetic field was generated for 2.8 ${\mu}$sec, and the period of generating the RF magnetic field was designed to 100msec for detecting the NMR signal repeatedly. The NMR signal, radiated from the sample in the magnetic console, was appeared as an amplitude-modulated signal with a frequency equal to the Larmor frequency. The signal, induced in the coil, was amplified in the tx/rx separation circuit, preamplifier and intermediate amplifier by a factor of 20.7dB, 36dB and 40dB, respectively, and the signal was detected by a synchronous detection circuits, then the NMR signal was obtained.

  • PDF

MPSoC Design Space Exploration Based on Static Analysis of Process Network Model (프로세스 네트워크 모델의 정적 분석에 기반을 둔 다중 프로세서 시스템 온 칩 설계 공간 탐색)

  • Ahn, Yong-Jin;Choi, Ki-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.10
    • /
    • pp.7-16
    • /
    • 2007
  • In this paper, we introduce a new design environment for efficient multiprocessor system-on-chip design space exploration. The design environment takes a process network model as input system specification. The process network model has been widely used for modeling signal processing applications because of its excellent modeling power. However, it has limitation in predictability, which could cause severe problem for real time systems. This paper proposes a new approach that enables static analysis of a process network model by converting it to a hierarchical synchronous dataflow model. For efficient design space exploration in the early design step, mapping application to target architectures has been a crucial part for finding better solution. In this paper, we propose an efficient mapping algorithm. Our mapping algorithm supports both single bus architecture and multiple bus architecture. In the experiments, we show that the automatic conversion approach of the process network model for static analysis is performed successfully for several signal processing applications, and show the effectiveness of our mapping algorithm by comparing it with previous approaches.

Bio-sensing Data Synchronization for Peer-to-Peer Smart Watch Systems (피어-투-피어 스마트워치 시스템을 위한 바이오 센싱 데이터 동기화)

  • LEE, Tae-Gyu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.813-818
    • /
    • 2020
  • Recently, with the rapid increase in technology and users of smart devices, the smart watch market has grown, and its utility and usability are continuously expanding. The strengths of smartwatches are wearable portability, application immediacy, data diversity and real-time capability. Despite these strengths, smartwatches have limitations such as battery limitations, display and user interface size limitations, and memory limitations. In addition, there is a need to supplement developers and standard devices, operating system standard models, and killer application modules. In particular, monitoring and application of user's biometric information is becoming a major service for smart watches. The biometric information of such a smart watch generates a large amount of data in real time. In order to advance the biometric information service, stable peer-to-peer transmission of sensing data to a remote smartphone or local server storage must be performed. We propose a synchronization method to ensure wireless remote peer-to-peer transmission stability in a smart watch system. We design a wireless peer-to-peer transmission process based on this synchronization method, analyze asynchronous transmission process and proposed synchronous transmission process, and propose a transmission efficiency method according to an increase in transmission amount.

DEVELOPMENT OF THE READOUT CONTROLLER FOR INFRARED ARRAY (적외선검출기 READOUT CONTROLLER 개발)

  • Cho, Seoung-Hyun;Jin, Ho;Nam, Uk-Won;Cha, Sang-Mok;Lee, Sung-Ho;Yuk, In-Soo;Park, Young-Sik;Pak, Soo-Jong;Han, Won-Yong;Kim, Sung-Soo
    • Publications of The Korean Astronomical Society
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • We have developed a control electronics system for an infrared detector array of KASINICS (KASI Near Infrared Camera System), which is a new ground-based instrument of the Korea Astronomy and Space science Institute (KASI). Equipped with a $512{\times}512$ InSb array (ALADDIN III Quadrant, manufactured by Raytheon) sensitive from 1 to $5{\mu}m$, KASINICS will be used at J, H, Ks, and L-bands. The controller consists of DSP(Digital Signal Processor), Bias, Clock, and Video boards which are installed on a single VME-bus backplane. TMS320C6713DSP, FPGA(Field Programmable Gate Array), and 384-MB SDRAM(Synchronous Dynamic Random Access Memory) are included in the DSP board. DSP board manages entire electronics system, generates digital clock patterns and communicates with a PC using USB 2.0 interface. The clock patterns are downloaded from a PC and stored on the FPGA. UART is used for the communication with peripherals. Video board has 4 channel ADC which converts video signal into 16-bit digital numbers. Two video boards are installed on the controller for ALADDIN array. The Bias board provides 16 dc bias voltages and the Clock board has 15 clock channels. We have also coded a DSP firmware and a test version of control software in C-language. The controller is flexible enough to operate a wide range of IR array and CCD. Operational tests of the controller have been successfully finished using a test ROIC (Read-Out Integrated Circuit).

Speed Control for Electric Motorcycle Using Fuzzy Controller (퍼지 제어기를 이용한 전기 이륜차의 속도 제어)

  • Ban, Dong-Hoon;Park, Jong-Oh;Lim, Young-Do
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.361-366
    • /
    • 2012
  • This paper presents speed control of an electric motorcycle using a fuzzy controller. The electric motorcycle required to meet not only fast throttle response but also stability, when it is on a cruise. However, a 1.5KW (50cc) electric motorcycles selling in the current market are difficult to cruise under the following conditions which are occupant's weight, load weight, wind resistance and road conditions (dirt roads, asphalt road). Because of these reasons, the rapid speed changing occurs in uphill and downhill road. To solve these problems, The input value for Improved fuzzy controller use the speed error and error variance. The output value for improved fuzzy controller uses Q-axis of the motor controlled variable. The D-axis of the motor output for improved fuzzy control uses D-axis controlled variable in proportional to Q-axis controlled variable. Improved fuzzy controller drives the electric motorcycle equipped with IPMSM. The control subject used in this paper is a 1.5KW electric motorcycle equipped with improved fuzzy controller that was used to control the motor speed. To control IPMSM Type of motor torque, D, Q-axis current controller was used. The Fuzzy controller using the proposed algorithm is demonstrated by experimental hardware simulator.

Utility of Surgical Resection in the Management of Metachronous Krukenberg's Tumors of Gastric Origin

  • Kim, Gwon-Sik;Kim, Kap-Choong;Kim, Beom-Su;Kim, Tae-Hwan;Yook, Heong-Hwan;Oh, Sung-Tae;Kim, Byung-Sik
    • Journal of Gastric Cancer
    • /
    • v.10 no.3
    • /
    • pp.111-117
    • /
    • 2010
  • Purpose: The aim of this study was to determine the prognostic factors and the significance of metastatectomy for Krukenberg's tumors of gastric origin.Materials and Methods: Among the patient who underwent gastric surgery from 1992 through 2005, 90 female patients with Krukenberg's tumors of gastric origin were identified. We retrospectively reviewed the clinicopathologic characteristics, prognostic factors, and treatments for primary gastric cancer. We also investigated the prognostic risk factors for the onset of metachronous Krukenberg's tumors and the survival time of patients who underwent an operation for metachronous Krukenberg's tumors. Results: The presence of a synchronous Krukenberg's tumor (mean survival time=17.6 months, P<0.01), peritoneal seeding (14.5 months, P<0.01), and non-curative resection (15.1 months, P<0.01), were statistically significant prognostic factors for survival time in female patients with gastric cancer. The stage of primary gastric cancer (P=0.049) and lymph node metastasis (P=0.011) were statistically significant risk factors for recurrence time of a metachronous Krukenberg's tumor. In the metachronous Krukenberg's tumor group (n=53), the mean survival time of the metastatectomy group (n=46, 43.2 months, P=0.012) was longer than that in the chemotherapy or conservative treatment groups (n=7 and 24 months, respectively). Metastatectomy, presense or abscence of residual tumor and extent of residual tumor were significant prognostic factors for survival time in female patients with metachronous Krukenberg's tumor of gastric origin. Conclusions: A close observation and evaluation with ultrasound or computed tomography is necessary in female patients with advanced gastric cancer to detect a metachronous Krukenberg's tumor as soon as possible. The surgeon must operate more aggressively in patients with metachronous Krukenberg's tumors.

The Clinicopathologic Features and Prognosis of Multiple Early Gastric Cancer (다발성 조기위암의 임상적 특징과 예후)

  • Ahn, Young-Jae;Oh, Sung-Jin;Song, Jye-Won;Kang, Wook-Ho;Hyung, Woo-Jin;Choi, Seung-Ho;Noh, Sung-Hoon
    • Journal of Gastric Cancer
    • /
    • v.8 no.4
    • /
    • pp.198-203
    • /
    • 2008
  • Purpose: Multiple early gastric cancer (MEGC) accounts for between 4.5% and 11.7% of all early gastric cancers (EGC). We investigated the treatment of MEGC from the viewpoint of the clinicopathologic features of the disease. Materials and Methods: 2,281 patients with EGC underwent gastric resection at the Department of Surgery, Severance Hospital during the 11 years between January 1994 and December 2004 and we carried out a retrospective analysis of these patients. Results: There were 91 cases of synchronous MEGC (4.0%) according to the diagnostic criteria of Moertel: there were 81 double, 9 triple and 1 quadruple lesions. Of the 102 accessory lesions, 64 (62.7%) were less than 10 mm in diameter and 83 (81.4%) were located in the same region as the main lesion. The most frequent histologic type of main lesion was a well differentiated adenocarcinoma, which was found in 52 cases (57.1%). There were 49 mucosal main lesions and 42 submucosal main lesions. Lymph node metastasis was detected in 6 cases (6.6%): 1 in mucosal lesions and 5 in submucosal main lesions Conclusion: Solitary EGC and MEGC had very similar clinopathological features and a similar prognosis. Therefore, we believe that the general EGC treatment guidelines can be applied for multiple EGC. It is important to evaluate the whole stomach before and during the operation and then after examining the resected specimen.

  • PDF

Changes in the Characteristics of Dissolved Organic Matter by Microbial Transformation and the Subsequent Effects on Copper Binding (생분해에 따른 용존 유기물질 성상 및 중금속 구리와의 결합특성 변화)

  • Jung, Ka-Young;Hur, Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.1
    • /
    • pp.49-54
    • /
    • 2012
  • Microbial changes in the characteristics of dissolved organic matter (DOM) and the subsequent effects on the conditional stability constants of copper were investigated using 14 day-incubations of Pony Lake fulvic acid (PLFA), Suwannee River fulvic acid (SRFA) and the mixtures of the humic substances and glucose. After incubation, dissolved organic carbon (DOC) concentrations were diminished, and specific UV absorbance values and DOC-normalized fluorescence intensities increased. The microbial changes were minimal for the samples contaning humic substances only whereas they were much pronounced for the mixtures with glucose. The extent of the changes increased with a higher content of glucose in the mixtures. The same trend was observed even for glucose solution. Our results suggest that labile organic moieties may be transformed into more chromophoric and humidified components by biodegradation. For the mixture samples, the copper binding stability constants did not change or even decreased after incubation. Therefore, microbially induced enrichment of the fulvic- and humic-like carbon structures in DOM appears to result in little change or the decrease of the copper binding coefficients.

Evaluation of Left Ventricular Assist Device through In Vivo Experiments (생체실험을 통한 좌심실보조기의 평가)

  • Park, Seong-Keun;Won, Yong-Soon;Jung, Pil-Sup;Choi, Jin-Wook;Kim, In-Young;Lee, Kyu-Baek;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.89-92
    • /
    • 1993
  • In this article, we present and analyze the results of the three consecutive in vivo experiments of the LVAD to evaluate the function of the LVAD and the adverse effects on living animals. We applied the LVAD consecutively to three mongrel dogs and the circulation of the blood was assisted under the anesthesia. We used in general both the asynchronous mode and the synchronous mode to drive the LVAD. During the experiments we monitored the dogs with a polygraph to evaluate the function of the LVAD and the additional effects on the natural hearts. We also examined several clinical pathologic tests in order to see the effects of the LVAD to the red blood cells and the other internal organs. The dogs survived for two to there days. The LVAD assisted the circulatory system at the maximum assist flow rate of 3.0 1/min. Although the red blood cells of the dogs had mechanical damages by the LVAD to result in the hemolysis, the degree of the hemolysis was not so high and the damages caused by the hemolysis on the dogs were not serious. The myocardium of the first dog was gradually worsened and eventually failed. The damage of the myocardium was due to the asynchronous driving mode of the LVAD. The other organs did not have serious damages due to the application of the LVAD. The main purpose of this paper is to evaluate the results of the in vivo experiments of the LVAD and to find better ways to the application of the LVAD to human beings.

  • PDF

A Study on 3[kW] PMA-RSG Optimal Design for Mobile Power Supply (이동형 전원장치용 3[kW] PMA-RSG의 최적 설계에 대한 연구)

  • Baik, Jei-Hoon;Toliyat, Hamid A.;Kim, Nam-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.109-117
    • /
    • 2009
  • In this paper, an analytical model using equivalent magnetic circuits for the PMA-SynRG is presented. The lumped parameter model (LPM) is developed from machine geometry, stator winding and machine operating specifications. By the LPM, magnetic saturation of rotor bridges is incorporated into model and it provides effective means of predicting machine performance for a given machine geometry. The LPM is not as accurate as finite element analysis but the equivalent magnetic circuits provide fast means of analyzing electromagnetic characteristics of PMa-SynRG. It is the main advantage to find the initial design and optimum design. The initial design of PMa_RSG is performed by LPM model and FEM analysis, and the final PMA-RSG design is optimized and identified by FEM analysis considering actual machine design. The linear LPM and the nonlinear LPM are programmed using MATLAB and all of machine parameters are calculated very quickly. To verify justification of the proposed design of PMa-RSM, back-EMF is measured.