• 제목/요약/키워드: Synchronous

검색결과 4,104건 처리시간 0.034초

다상 영구자석 동기전동기의 고장특성 해석에 관한 연구 (Faults Analysis and Dynamic Simulation Method for Poly-Phase PM Synchronous Motor)

  • 최세권;조준석;김주용;정태욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.826_827
    • /
    • 2009
  • This paper introduces major potential faults of Poly-Phase Permanent Magnet Synchronous Motor and their simulation realization methods. The faults of Poly-Phase PM Synchronous Motor, generally, stator turn faults, demagnetizing field. Based on the derived expressions, Poly-Phase PM synchronous Motor simulation model, which is capable of representing stator turn faults, is implemented in Maxwell.

  • PDF

객체지향기법을 적용한 디지탈 컴퓨터 시뮬레이터를 이용한 동기 발전기 시뮬레이션 (Simulation of Synchronous Machines Using Object-Oriented Digital Computer Simulator)

  • 박지호;백영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.102-105
    • /
    • 1995
  • In power system stability analysis, modelling of the synchronous machine is necessary and vary important. In this paper, a synchronous machine is modeled and simulated by using Object-Oriented method. The mathematical equations describing the dynamic behavior of the synchronous machine is represented by block diagram and Objected-Oriented Digital Computer Simulater(ODCS). The developed method is tested for a one-machine-to-infinite-bus system, which is accurate and very useful for a multi-machine system simulation.

  • PDF

화력발전소의 동기발전기 여자기 성능개선 연구 (The Improvement of the Synchronous Genertor Excitor performance for Power Fire Plant)

  • 홍현문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.998-998
    • /
    • 2008
  • It is difficult to find for analysis solution of the synchronous generator exciter system. Recently, it had good performance UPS converter system using CRA method. The single converter of synchronous generator excitor system under considerations : (i) the overall system shall keep very low AC-voltage tracking error as well as no phase delay over different load condition, and (ii) the digital controller shall be employed at a fixed sampling. It is shown that the synchronous exciter system can be achieved by the proposed controller using Characteristic Ratio Assignment.

  • PDF

동기릴럭턴스전동기의 전류센서리스 제어 성능 고찰 (Considerations on the Performance of Current Sensorless Control of a Synchronous Reluctance Motor)

  • 신명호
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.61-65
    • /
    • 2012
  • Some works about the current sensorless control of a synchronous reluctance motor have been presented. However, there is no analysis about the performance and the detuning effect of the current sensorless control. This paper presents the problems and the detuning effect of the current sensorless control of a synchronous reluctance motor by simulation results. In addition, torque limiter is proposed to limit the torque current within the torque limit.

CRA 제어기법을 이용한 동기발전기 여자기의 출력 개선 (The Improvement Output of the Synchronous Generator Excitor using CRA control method)

  • 홍현문
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.449-450
    • /
    • 2008
  • It is difficult to find for analysis solution of the synchronous generator exciter system. Recently, it had good performence UPS converter system using CRA method. The single converter of synchronous generator excitor system under considerations : (i) the overall system shall keep very low AC-voltage tracking error as well as no phase delay over different load condition, and (ii) the digital controller shall be employed at a fixed sampling. It is shown that the synchronous exciter system can be achieved by the proposed controller using Characteristic Ratio Assignment.

  • PDF

DSP를 이용한 Synchronous Buck Converter의 병렬 제어 (Parallel Control of Synchronous Buck Converter Using DSP)

  • 김정훈;임정규;신휘범;정세교;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.140-142
    • /
    • 2006
  • This paper represents a digital parallel control of a synchronous buck converter using a digital signal processor (DSP). The digital PWM and load sharing controller is implemented in the DSP TMS320F2812 and the experimental results are provided to show the feasibility of the digital synchronous buck regulator.

  • PDF

Self-Commissioning for Surface-Mounted Permanent Magnet Synchronous Motors

  • Urasaki, Naomitsu;Senjyu, Tomonobu;Uezato, Katsumi
    • Journal of Power Electronics
    • /
    • 제3권1호
    • /
    • pp.33-39
    • /
    • 2003
  • This paper presents the self-commissioning for surface-mounted permanent magnet synchronous motor. The proposed strategy executes three tests with a vector controlled inverter drive system. To do this, synchronous d-q axes currents are appropriately controlled for each test. From the three tests, armature resistance, armature inductance, equivalent iron loss resistance, and emf coefficient are identified automatically. The validity of the proposed strategy is confirmed by experimental results.

동기정류기를 이용한 200W급 공진형 플라이백 DC-DC 컨버터에 관한 연구 (A study on the 200W class QR flyback DC-DC converter with synchronous rectifier)

  • 원기식;안태영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.295-297
    • /
    • 2005
  • This paper presents a novel current driving method for the synchronous rectifier (SR) in a Flyback topology. The proposed current driven synchronous rectifier features low Power loss, good performance and the gate voltage of FET in the synchronous rectifier is easily controlled by zener voltage. The proposed SR driving method is implemented in a 200W Flyback converter with 400Vdc input and achieved excellent performance at full load.

  • PDF

영구자석 유도동기전동기의 특성해석 및 시제품에의 응용 (Characteristic Analysis of Synchronous induction motor with Permanant Magnets & Its application)

  • 한문규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.324-326
    • /
    • 1999
  • For induction motors cannot maintain constant speed in various speed conditions, synchronous motors are generally used. But synchronous motor oscillate in shocking load, and it cannot start by itself for the lack of starting torque. In this paper, we analyzed the synchronous induction motor which has both characteristics, and compared the experimental results with FEM analysis.

  • PDF

매계분수 기정에 의한 동기식의 모델링에 관한 연구 (A study on the Synchronous Machine Modeling by Parameter Modification)

  • 김준현;유석구;설용태
    • 대한전기학회논문지
    • /
    • 제32권11호
    • /
    • pp.379-386
    • /
    • 1983
  • In this paper,the more accurate and simple synchronous machine model is derived by parameter modification method. At first, the flux linkage state space model is composed by redefining the parameters of synchronous machine and considering the saturation effect approximately. After that, this modified model is apply to the power system model and the effects of power system stability is analyzed by this model's characteristics in fault condition. As the result, the modified synchronous machine model shows more accurate and simple than the privious one.

  • PDF