• Title/Summary/Keyword: Switching loss model

Search Result 96, Processing Time 0.027 seconds

An Application-based Forwarding Model of MPLS ATM Switching System for Differential Services (차별화 서비스를 위한 MPLS ATM 교환 시스템의 응용 기반 포워딩 모델 설계)

  • 김응하;조영종
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.3C
    • /
    • pp.201-210
    • /
    • 2002
  • A number or MPLS ATM switching system have been proposed to increase the access speed or current routers, but they cannot satisfy the Internet users who use diverse applications. So they are required to support the so-called differential service, which discriminates service behaviors according to the service class. In this paper, to support this differential service we suggest an LSP control method, which uses the extended LDP message and establishes several different LSPs for each FEC according to the service class. Also, we propose an marking algorithm using the cell loss priority field or ATM cells in order to process the differential service according to application categories. In addition, we present a forwarding procedure based on the LSP control method and the marking algorithm. A forwarding model applied this forwarding procedure can be easily implemented with a minimum modification of existing MPLS ATM switching systems. Therefore, we can save cost and time needed to implement the proposed model. Finally, we estimate the performance behaviors of the proposed application-based forwarding model by the AweSim simulation package.

High frequency resonant inverter using time sharing control method for multipling output frequency (출력주파수체배 공진형 고주파 인버어터)

  • Bae, Y.H.;Hong, S.T.;Lee, H.W.;Kwon, S.K.;Seo, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1129-1132
    • /
    • 1992
  • This paper proposes a high frequency resonant inverter consisting of equivalent half bridge model using MOSFET. In this paper time-sharing control method is applied. as a result the output frequency is two times as high as switching frequency of device, and average current of device is incresed because of decreasing switching loss.

  • PDF

Numerical Analysis and Design of Moving Contactless High Power Transformer

  • Lee, Dong-Su;Jang, Dong-Uk;Kim, Hyung-Chul;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.423-426
    • /
    • 2011
  • This paper presents numerical analysis and design of high power contactless transformer with a large air-gap for moving on a guided linear track which is appropriate for high-speed train or MAGLEV. The system has the typical characteristics of large leakage inductance, small magnetizing inductance, and low coupling coefficients giving rise to lower power transfer efficiency, which have been compensated by the purposely-designed contactless transformer coupled with the resonant converter modulating with high switching frequency. In particular, the best model selected from the generated six design candidates has been applied for 3D Finite Element Analysis (FEA) investigating on iron loss to evaluate the overall system efficiency.

A Trade-Off between the Efficiency, Ripple and Volume of a DC-DC Converter

  • Taherbaneh, Mohsen;Rezaie, Amir H.;Ghafoorifard, Hasan;Mirsamadi, Maddad;Menh, Mohammad B.
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.621-631
    • /
    • 2011
  • In space qualified DC-DC converters, optimization of the following electrical characteristics is of greater interest in comparison with other specifications; power loss/efficiency, output voltage ripple and volume/weight. The main goal of this paper is to present an appropriate solution for optimizing the above mentioned characteristics. For this purpose, a comprehensive power loss model of a DC-DC converter is fully developed. Proper models are also demonstrated for assessment of the output voltage ripple and the utilized transformer volume as the bulkiest component in a DC-DC converter. In order to provide a test bed for evaluation of the proposed models, a 50W push-pull DC-DC converter is designed and implemented. Finally, a novel cost function with three assigned weight functions is proposed in order to have a trade-off among the power loss, the output voltage ripple and the utilized transformer volume of the converter. The cost function is optimized for applications in which volume has the highest priority in comparison with power loss and ripple. The optimization results show that the transformer volume can be decreased by up to 51% and this result is verified by experimental results. The developed models and algorithms in this paper can be used for other DC-DC converter topologies with some minor modifications.

Heat Load Estimation-Based Switching Explicit Model Predictive Temperature Control for VRF Systems (시스템 에어컨의 온도 제어를 위한 부하 예측 기반 스위칭 모델 예측 제어)

  • Jun-Yeong Kim;S.M. Lee
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.19 no.3
    • /
    • pp.123-130
    • /
    • 2024
  • This paper proposes an EMPC (Explicit Model Predictive Controller) for temperature tracking control based on heat load prediction by an ESO (Extended State Observer) for a variable cooling circulation system with multiple indoor units connected to one outdoor unit. In this system, heat transfer and heat loss relative to the input temperature are modeled using system dynamics. Using this model, we design an EMPC based on an ESO that is robust to temperature changes and depends on airflow. To determine the stability of both the controller and the observer, asymptotic stability is verified through Lyapunov stability analysis. Finally, to validate the performance of the proposed controller, simulations are conducted under three scenarios with varying airflow, set temperature, and heat load.

Routing Decision with Link-weight Calculating Function in WDM Switching Networks

  • Charoenphetkul, Pongnatee;Thipchaksurat, Sakchai;Varakulsiripunth, Ruttikorn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1346-1349
    • /
    • 2004
  • In this paper, we have proposed the new link-weight calculating function using for routing decision in WDM networks. The proposed link-weight calculating functions includes following factors those are available wavelengths per link, distance loss, total wavelengths, and limited wavelength conversion. The calculated link-weight is applied into the algorithm of routing decision in order to determine the available lightpath that qualifies user requests. The objective is to improve the performance of wavelengths assignment with fast determining the suitable lightpath by using the proposed link-weights calculating function. The analytical model of WDM switching networks is introduced for numerical analysis. The link-weight calculating function is performed. Finally, the performance of proposed algorithm is displayed with numerical results in term of the blocking probability, the probability that connection requests from users are rejected due to there are no available lightpath to be assigned for them. It is also shown that the blocking probability is varied in depending on the number of available wavelengths and the degree of wavelength conversion. The numerical results also show that the proposed link-weight calculating function is more cost-effective choice for the routing decision in WDM switching networks.

  • PDF

The Dynamic Flow Admission Control for Providing DiffServ Efficiently in MPLS Networks (MPLS 네트워크에서 DiffServ를 효율적으로 적용하기 위한 동적 흐름 수락 제어)

  • Im, Ji-Yeong;Chae, Gi-Jun
    • The KIPS Transactions:PartC
    • /
    • v.9C no.1
    • /
    • pp.45-54
    • /
    • 2002
  • MPLS(Multiprotocol Label Switching) is regarded as a core technology for migrating to the next generation Internet. In this paper, we propose an dynamic flow admission control supporting DiffServ(Differentiated Services) to provide QoS in MPLS networks. Our proposed model dynamically adjusts the amount of admissible traffic based on transmittable capacity over one outgoing port. It then transmits the Packets while avoiding congested area resulting traffic loss. Ingress LSRs find out the congested area by collecting network state information at QoS state update for QoS routing table. Our Proposed model manages the resource efficiently by protecting the waste of resources that is a critical Problem of DiffServ and makes much more flows enter the network to be served.

The structure of ATM Switch with the Shared Buffer Memory and The Construction of Switching Network for Large Capacity ATM (대용량 ATM을 위한 공유 버퍼 메모리 스위치 구조 및 교환 망의 구성 방안)

  • 양충렬;김진태
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.1
    • /
    • pp.80-90
    • /
    • 1996
  • The efficienty of ATM is based on the statical multiplexing of fixed-length packets, which are called cells. The most important technical point for realizing ATM switching network is an arrangement of the buffers and switches. Current most ATM switching networks are being achieved by using the switching modules based on the unit switch of $8{\times}8$ 150Mb/s or $16{\times}16$ 150Mb/s, the unit switch of $32{\times}32$150Mb/s for a large scale system is under study in many countries. In this paper, we proposed a new $32{\times}32$(4.9Gb/s throughput) ATM switch using Shared buffer memory switch which provides superior traffic characteristics in the cell loss, delay and throughput performance and easy LSI(Large Scale Integrated circuit). We analytically estimated and simulated by computer the buffer size into it. We also proposed the configuration of the large capacity ATM switching network($M{\times}M$.M>1,000) consisting of multistage to improve the link speed by non-blocking.

  • PDF

Loss Calculation of a High Power DC-DC Converter Considering DC Bias Characteristic of Inductor (인덕터의 DC 바이어스 특성을 고려한 대용량 DC-DC 컨버터의 손실계산)

  • Jo, Young-Chang;Choi, Ju-Yeop;Jung, Seung-Ki;Choy, Ick;Song, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.789-795
    • /
    • 2011
  • It is necessary to accurately predict converter losses for optimized design of a high-power DC-DC converter. The losses of switching devices and inductor among the elements of the converter take significantly greater proportion. The current ripple will be determined by the size of the inductance and this inductance value varies depending on the DC amount of inductor current. As the inductance changes according to load current, the change influences not only the inductor loss itself but also the total converter loss. In this paper, for more accurate design of a bi-directional DC-DC converter for 30kW-class energy storage system, more accurate computational model is proposed considering inductance variation according to the load current change. The inductance changes using variable magnetic cores are verified and converter efficiency is tested through simulations and experiments.

The New Active Voltage Clamp ZVS-PWM Resonant High-frequency Inverter (새로운 액티브 전압 클램프 ZVS-PWM 공진 고주파 인버터)

  • Ahn, Yong-Wie;Kim, Hong-Shin;Mun, Sang-Pil;Woo, Kyung-Il;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.188-193
    • /
    • 2017
  • In this paper, a ZVS-PWM high-frequency inverter with a PWM control function is applied to commercial system 220[Vrms], and a resonator type ZVS-PWM high-frequency inverter circuit with a fixed-two methods were proposed. The parameters of the transformer model equivalent circuit of a copier fixing device, which is an essential element in the parameter optimization of the proposed circuit, are obtained by using a high-frequency amplifier and its frequency characteristics are described. The proposed method compared to the existing single-ended ZVS-PFM high frequency inverter can suppress the voltage and current peak value of the power semiconductor switching device and reduce the switching loss. The efficiency of the proposed method itself is 98[%] at rated power output. Also, the efficiency of 96[%] can be obtained even at low output, so that the proposed high frequency inverter is very efficient inverter. The total efficiency from the commercial AC input to the inverter output is 93[%] at rated, which is considered efficient for use in copying machines. In addition, the diode bridge loss accounts for the largest portion of the overall system efficiency distribution. On the other hand, the nonparallel filter has a very low loss.