• Title/Summary/Keyword: Switching arc

Search Result 91, Processing Time 1.062 seconds

ABLATION OF PTFE NOZZLE DRIVEN BY ARC PLASMA (아크 플라즈마에 의한 PTFE 노즐 용삭현상)

  • Lee J.C.;Kim Y.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.311-317
    • /
    • 2005
  • It has been the most progressive interruption technique to use the ablation gas from the surface of PTFE nozzle driven by arc plasma during switching process in $SF_6$ gas circuit breakers. This advanced interruption technique can reduce the required mechanical energy to compress and blow the gas for extinguishing the arc plasma between the electrodes due to using the ablation effect instead. In order to consider the phenomena during calculation of switching process, it is required to confirm the principles of ablation from PTFE nozzle as well as of arc plasma during switching process. In this study, we have calculated the switching process considered the ablation of PTFE nozzle driven by arc plasma using multidisciplinary simulation technique and compared the results with the data without the ablation effect. More $50\%$ difference of pressure rise inside expansion chamber has been found from the results and it should be indispensable for this type of computational work to consider and include the ablation effect of PTFE nozzle. Further study on turbulence and radiation will be followed.

  • PDF

The analysis of arc dispersion and contacts characteristics according to switching of RCD for low voltage (저압용 누전차단기의 스위칭에 따른 아크 비산 및 접점의 특성분석)

  • Kim, Dong-Woo;Kim, Hyang-Kon;Gil, Hyung-Jun;Han, Woon-Ki;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.69-73
    • /
    • 2005
  • The arc dispersion and contacts characteristics were analyzed according to switching off Residual Current Protective Device(RCD) switch. Arc dispersion process was taken by high speed imaging system at a rate of 10,000 frames per second. When RCD was switched from on to off, art was observed and it took about 2.3[ms] from the generation of arc to the extinction of arc. When RCD was switched from off to on, arc was not observed. We repeated switching on and off 1000, 3000 and 6000 times. After repetition, the surface characteristics of contacts were taken by stereo microscope and Scanning Electron Microscope(SEM). From the scattering patterns analysis of arc and the analysis of deteriorated contacts, it could be applicable to the research of electric fire and arc suppression.

  • PDF

DC Arc Extinction Using External Magnetic Field in Switching Device

  • Cho Hyun-Kil;Lee Eun-Woong;Jeong Jong-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.306-311
    • /
    • 2005
  • In this paper, the electromagnetic force acting in the arc column of 3 different extinction units is compared with using the FEM (Finite Element Method) and the arc velocity is calculated by the drag force of the fluid mechanics. The experiment for breaking the arc current was performed in each model at 100 volts in order to measure the arcing time. The outcome was compared with the computing value. As a result, this paper proposes that the divided U-shaped grid is able to shorten arcing time and improve the electric performance. It also suggests a methodology for comparing and analyzing the result obtained by simulation and experiment.

Understanding Switching Arcs and Dielectric Capability of a SF6 Self-Blast Interrupter

  • Lee, Won-Ho;Kim, Cheol-Su;Lee, Jong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.196.2-196.2
    • /
    • 2016
  • The design and development procedures of SF6 gas circuit breakers are still largely based on trial and error through testing although the development costs go higher every year. The computation cannot cover the testing satisfactorily because all the real processes arc not taken into account. But the knowledge of the arc behavior and the prediction of thermal plasmas inside SF6 interrupters by numerical simulations are more useful than those by experiments due to the difficulties to obtain physical quantities experimentally and the reduction of computational costs in recent years. In this paper, in order to get further information into the interruption process of a SF6 self-blast interrupter, which is based on the combination of thermal expansion and arc rotation, gas flow simulations with a CFD-arc modeling are performed during the whole switching process such as high-current period, pre-current zero period, and current-zero period. Through the complete work, the temperature of residual arcs as well as the breakdown index after current zero should be a good criterion to predict the dielectric capability of interrupters.

  • PDF

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

DC Rail Side Series Switch and Parallel Capacitor Snubber-Assisted Edge Resonant Soft-Switching PWM DC-DC Converter with High-Frequency Transformer Link

  • Morimoto, Keiki;Fathy, Khairy;Ogiwara, Hiroyuki;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.181-190
    • /
    • 2007
  • This paper presents a novel circuit topology of a DC bus line series switch and parallel snubbing capacitor-assisted soft-switching PWM full-bridge inverter type DC-DC power converter with a high frequency planar transformer link, which is newly developed for high performance arc welding machines in industry. The proposed DC-DC power converter circuit is based upon a voltage source-fed H type full-bridge soft-switching PWM inverter with a high frequency transformer. This DC-DC power converter has a single power semiconductor switching device in series with an input DC low side rail and loss less snubbing capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge arms and DC bus line can achieve ZCS turn-on and ZVS turn-off transition commutation. Consequently, the total switching power losses occurred at turn-off switching transition of these power semiconductor devices; IGBTs can be reduced even in higher switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules can be realized at 60 kHz. It is proved experimentally by power loss analysis that the more the switching frequency increases, the more the proposed DC-DC power converter can achieve a higher control response performance and size miniaturization. The practical and inherent effectiveness of the new DC-DC converter topology proposed here is actually confirmed for low voltage and large current DC-DC power supplies (32V, 300A) for TIG arc welding applications in industry.

A Study on the Power Supply System for the Arc Lamp (아크램프를 위한 전원공급 시스템의 연구)

  • La, Jae Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.125-130
    • /
    • 2018
  • Arc lamps are now widely utilized as illumination sources for a large number of investigations in wide-field fluorescence microscopy. Among many power converters for the lamp, the PSFB (Phase-Shift Full-Bridge) converter with the ZVS (Zero Voltage Switching) is the most widely used soft switched circuit in high-power applications. Also, in the most luminaries, the power factor has to be more and more important. Thus, the power factor correction(PFC) must be included in the power system. A new igniter module using the switching power device and the transformer is proposed instead of the conventional igniter using the mechanical contactor. The proposed converter with the high power factor and high efficiency is verified through the experimental works.

A Zero-Voltage and Zero-Current Switching Full Bridge DC-DC Converter for Arc Welding Machines (아크 용접에 적합한 영전압영전류 방식의 풀브릿지 컨버터)

  • Jeon, Seong-Jeup
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.6
    • /
    • pp.342-348
    • /
    • 1999
  • A new welding machine which adopts zero voltage and zero current switching(ZVZCS) full bridge(FB) DC-DC converter is proposed. The proposed ZVZCS FB DC-DC converter uses auxiliary transformer to obtain ZCS for leading leg. It has capability of controlling load current even in short circuit condition and is suitable for arc welding machines. The power rating of the auxiliary transformer is about one 5th to one 10th of the main transformer. Experimental results for 10KW prototype are shown to verify the principle of operation.

  • PDF

Arc Extinguishing of a Vacuum Interrupter for an HTS First Peak Current Limiter (반주기내 한류성능을 위한 진공차단기의 아크소호)

  • Kim, W.S.;Park, C.R.;Hyun, O.B.;Kim, H.R.;Yim, S.W.;Yu, S.D.;Yang, S.E.
    • Progress in Superconductivity
    • /
    • v.12 no.1
    • /
    • pp.23-26
    • /
    • 2010
  • A double line commutation (DLC) type SFCL with first peak limiting function has been proposed for ideal fault current limiting operation. Very fast switching (commutation) without any arc or high voltage problems for any kind of switching device is needed for the first peak current limiting. We've tried to find suitable conditions for a successful switching of a Vacuum Interrupter (VI) with HTS elements as a Peak Current limiting Resistance (PCR).