• 제목/요약/키워드: Switching Rectifier

검색결과 392건 처리시간 0.024초

1차측 환류 다이오드를 제거한 ZVS Three-Level DC/DC 컨버터에 관한 연구 (A Study on the Zero-Voltage-Switching Three-Level DC/DC Converter without Primary Freewheeling Diodes)

  • 전용진;김용;배진용;이은영;최근수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.183-187
    • /
    • 2005
  • A Zero-Voltage-Switching(ZVS) Three-Level Converter realizes ZVS for the switches with the use of the leakage inductance(or external resonant inductance) and the output capacitors of the switches, however; the rectifier diodes suffer from recovery which results in oscillation and voltage spike. In order to solve this problem, this paper proposes a novel ZVS Three-Level converter, which introduces two clamping diodes to the basic Three-Level converter to eliminate the oscillation and clamp the rectified voltage to the reflected input voltage, the proposed ZVS Three-Level converter can be simplified by removing the two freewheeling diodes.

  • PDF

PSpice 시뮬레이션을 이용한 전자식 스타터의 설계 (Design of An Electronic Starter Using PSpice Simulation)

  • 이동호;곽재영;여인선;정영춘
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1997년도 추계학술발표회논문집
    • /
    • pp.11-13
    • /
    • 1997
  • Abstract - An electronic starter using MOSFET has been designed to take advantage of ideal preheating and starting features which can extend the lifetime of fluorescent lamps. The preheating circuit of the developed electronic starter is consisted of four parts - afull-wave rectifier circuit, an FET switching circuit a timer circuit for the gate switching, and a circuit for end-of-life protection. The circuit is analyzed by using PSpice simulation, and is improved to give an appropriate starting-time through control of R-C time constant of the timer circuit. And the circuit is also provided with an end-of-life protection feature, which utilizes the negative resistance characteristics of a thermistor that is thermally linked to FET through a heatsink. This also protects the FET from any overheating problems. From the results of simulation it is possible to obtain an appropriate value on the starting time for proper ignition and also it is verified that the limit for resistance of the thermistor is dependant on the value of resistance is the timer circuit

  • PDF

동기 정류기를 이용한 태양광 모듈용 인터리브드 플라이백 인버터 소프트 스위칭 제어 기법 (Soft Switching Control Method for Photovoltaic AC Module Interleaved Flyback Inverter using Synchronous Rectifier)

  • 장진우;김영호;정용채;류동균;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.63-64
    • /
    • 2012
  • 본 논문에서는, 태양광 AC 모듈 기반의 인터리브드 플라이백 인버터에서의 동기 정류기를 이용한 소프트 스위칭 제어 기법을 제안한다. 제안된 방식은, 동기정류기를 이용하여 다이오드의 전도손실을 줄이고, 1차측 주스위치의 ZVS(Zero Voltage Switching) 턴-온을 수행하여 스위칭 손실을 저감하였다. 본 논문에서는 제안된 시스템의 타당성을 이론적 분석과 시뮬레이션을 통해 검증한다.

  • PDF

2차측 보조 소프트 스위칭 고주파 절연형 무정전전원장치 (Uninterruptible power supply using the secondary auxiliary soft switching high frequency insulating)

  • 김주용;서기영;이현우;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1413-1415
    • /
    • 2005
  • In paper, propose new partial resonance ZCS PWM controlled High frequency insulating Full-bridge DC/DC converter not using exciting current of high frequency transformer. It is compared with the existing principles in characteristics. It also realizes a widely stabilized ZVS operating using new On-Off control method at synchronized power rectification MOSFET of high frequency insulating transformer secondary. Finally, it is brought over 97[%] measurement -efficiency by proposed DC-DC converter. It is proved effectiveness of new methods using DC UPS PWM rectifier as switching power.

  • PDF

두 개의 인덕터를 갖는 PV-MIC용 준공진 부스트 컨버터 (Quasi-resonant Two-Inductor boost converter for PV-MIC)

  • 박승원;김재형;김준구;류동균;김태훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.188-189
    • /
    • 2010
  • This paper proposed a new zero-voltage switching(ZVS) Two-Inductor boost converter. The conventional Two-Inductor boost converter has defect. When the switch is turned off, the high voltage spike is occurred in the switch by leakage inductance and switch parasitic capacitor. To solve this problem, the parallel resonant capacitor is added to the conventional Two-Inductor boost converter. Using quasi-resonant between parallel resonant capacitance and leakage inductance, the switches is operated soft switching. A reduction of transformer turn ratio is achieved by the voltage doubler rectifier.

  • PDF

보조 권선형 능동 스너버를 적용하여 낮은 스위치 서지 전압 특성을 갖는 유사 공진형 컨버터에 관한 연구 (A Study on Quasi Resonant Converter with Low Switching Surge Voltage Characteristics by Applying Auxiliary Winding Type Active Snubber)

  • 안태영
    • 반도체디스플레이기술학회지
    • /
    • 제17권4호
    • /
    • pp.56-61
    • /
    • 2018
  • In this paper, a new type of active snubber was proposed to lower the excessive rated voltage of the clamp capacitor which was a problem in the conventional circuit by applying auxiliary winding into the active snubber. A simplified equivalent circuit of the proposed snubber was derived by applying it to QR flyback converter, and the equivalent circuits for each switch state was shown under the steady-state condition. In addition, the maximum voltage of the clamp capacitor as well as the main switch was found by using the steady-state equations. In particular, it was found that the clamp capacitor voltage could be controlled by the auxiliary winding ratio. In order to verify the utility and practicality of the proposed converter with auxiliary winding type active snubber circuit, a prototype with an output voltage of 19V and a maximum load current of 6A was produced and the results were reported.

전압 리플을 이용해 영전류 스위칭하는 두 개의 트랜스포머를 가지는 위상천이 풀-브릿지 컨버터 (Zero-Current Switching Two-Transformer Phase-Shifted Full-Bridge Converter using Voltage Ripple)

  • 한상규;문건우;윤명중;윤현기
    • 전력전자학회논문지
    • /
    • 제11권1호
    • /
    • pp.14-21
    • /
    • 2006
  • 본 논문에서는 출력 전압의 리플을 이용하여 지상 레그(lagging leg)의 스위치들의 영전류 스위칭(ZCS)을 수행하는 두 개의 트랜스포머를 가지는 위상천이 풀-브릿지 컨버터를 제안하다. 제안된 컨버터는 진상 레그(leading leg)의 스위치들은 영전압 스위칭(ZVS)을 수행하고, 지상 레그의 스위치들은 출력 전압-더블러(Voltage-Doubler)의 전압 리플차를 이용해 출력 다이오드의 전류 전환(commutation)이 빠르게 이루어지도록 하여서 중부하에는 영전류 스위칭을, 경부하에서는 영전압 스위칭을 가능하게 한다. 또한 출력측의 전압 리플차를 이용하기 때문의 기존의 1차측 부스트 캐패시터를 이용하는 컨버터에 비해 턴비를 이용하여 보다 빠른 전류 전환을 수행할 수 있는 장점을 가진다. 따라서 별도의 추가적인 소자없이 모든 스위치의 소프트스위칭이 가능하도록 하고, 지상 레그의 영전류 스위칭을 통해서 환류구간의 순환전류도 없애줌으로써 높은 효율을 얻을 수 있다. 모드 해석과 실험을 통하여 제안 컨버터의 성능을 검증한다.

3차 고조파 주입에 의한 단상 PWM컨버터의 고역률 제어 (Power Factor Correction of Single-phase PWM Converter using Third Harmonic Injection)

  • 손진근;유성식;김병진;박종찬;전희종
    • 조명전기설비학회논문지
    • /
    • 제13권3호
    • /
    • pp.25-33
    • /
    • 1999
  • 본 논문에서는 다이오드 정류기와 부스트 컨버터가 결합되 단상 PWM컨버터의 역률보상 및 고조파 저감 기법에 관하여 연구하였다. 일반적인 다이오드 정류기의 경우에서는 전원 입력측에 불연속 펄스 전류가 흘러서 역률의 저하 및 고조파 왜곡이 포함되어 다른 전원계통에 악영향을 주는 문제점이 있다. 이를 해결하기 위하여 본 논문에서는 3차 고조파가 주입된 PWM 기법을 사용하여 입력전류에서의 고조파왜곡이 감소되는 AC-DC 부스트 컨버트를 제안하였다. 이때의 부스트 컨버터는 스위칭 손실 및 회로구성이 용이한 불연속적전류모드 제어방식을 채용하였다. 스위칭 주파수가 5[kHz]인 컨버터를 구성하여 컴퓨터 시뮬레이션 및 실험을 행하였으며 그 결과 역률 보상 및 전 고조파 왜곡이 감소되었음을 확인하였다.

  • PDF

전류센서리스 단위역률 3상 PWM AC/DC Boost 컨버터 (Current Sensorless Three Phase PWM AC/DC Boost Converter with Unity Power Factor)

  • 천창근;김철우
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.105-112
    • /
    • 2003
  • AC/DC 전력변환장치로서 위상제어 컨버터나 출력전압을 제어할 수 없는 다이오드 정류기는 역률저하 및 저차고조파 발생의 문제점을 가진다. 본 논문에서는 역률개선 및 고조파 감소의 문제점을 극복하기 위하여 3상 PWM AC/DC Boost 컨버터에 대해 연구하였다. 제안한 컨버터의 특성은 입력 단에 전류 센서 없이 전압 센서만을 사용하여 입력전류의 위상을 조정하는 비교적 간단한 알고리즘으로 단위역률을 구현하였으며, 일정 주파수로 스위칭 소자를 구동시키는 정현 PWM 방식을 채용하여 불규칙한 스위칭 주파수 방식에서 나타나는 입력필터의 설계 및 스위칭 소자 선정에 대한 어려움을 극복하였다. 본 논문에서 제안한 제어알고리즘을 시뮬레이션 한 결과 부하영역 및 발전영역에서도 단위역률이 잘 이루어졌으며 DC link 단의 출력전압이 거의 리플 없이 다이나믹한 응답특성을 보였다. 또 시뮬레이션으로 얻어진 회로정수를 바탕으로 인덕터 및 커패시터의 용량을 적절한 크기로 산정하여 실험 에 적용한 결과 같은 부하조건에서 다이오드 정류기와 비교하여 역률 및 저차 고조파가 현저하게 개선되었음을 알 수 있었다.

영전압 제어 방법을 적용한 가변 펄스형 Nd:YAG 레이저시스템 (A Variable pulsed Nd:YAG laser system adopted ZCC method)

  • Doo-Youl Park;Whi-Young Kim
    • 한국컴퓨터산업학회논문지
    • /
    • 제2권3호
    • /
    • pp.357-362
    • /
    • 2001
  • 기존의 레이저통신용 스위칭 방식은 변압기 2차측에 정류부 및 평활용 콘덴서가 필수적으로 포함되어 있으며, 이렇게 얻어진 직류전압의 후단부를 스위칭 하게 되므로 시스템장치가 복잡하다. 또한 스위칭에 의한 손실이 크고, 펄스반복율(pulse repetition rate)이 증가할수록 콘덴서에 저장된 에너지가 램프로 충분히 전달되지 못하여 레이저 출력 효율이 저감되는 단점이 있다. 본 연구에서는 스위칭에 의한 손실을 줄여 레이저의 출력 효율을 개선하고자 교류전압의 영점(ZERO)을 ZCC(zero cross control)방식으로 검출하여 변압기 2차측 교류전압의 영점에서 SCR을 턴-온(turn-on)시키는 레이저 시스템을 설계 및 제작하였다. 그 결과 기존의 평활용 콘덴서와 정류부를 사용한 레이저 시스템보다 펄스반복울이 10[pps]씩 증가할수록 레이저 출력 효율 약 3.5$\%$씩 증가하여 60pps에서는 약 25$\%$까지 상승하였다.

  • PDF