• 제목/요약/키워드: Switching Modulation

검색결과 724건 처리시간 0.031초

Optimized PWM Switching Strategy for an Induction Motor Voltage Control

  • Lee, Hae-Hyung;Hwang, Seuk-Yung
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.527-533
    • /
    • 1998
  • An optimized PWM switching strategy for an induction motor voltage control is developed and demonstrated. Space vector modulation in voltage source inverter offers improved DC-bus utilization and reduced commutation losses, and has been therefor recognizedas the perfered PWM method, especially in the case of digital implementation. Three-phase invertor voltage control by space vector modulation consists of switching between the two active and one zero voltage vector by using the proposed optimal PWM algorithm. The prefered switching sequence is defined as a function of the modulation index and period of a carrier wave. The sequence is selected by suing the inverter switching losses and the current ripple as the criteria. For low and medium power application, the experimental results indicate that good dynamic response and reduced harmonic distortion can be achieved by increasing switching frequency.

  • PDF

Single Pulse-Width-Modulation Strategy for Dual-Active Bridge Converters

  • Byen, Byeng-Joo;Jeong, Byong-Hwan;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.137-146
    • /
    • 2018
  • This paper describes a single pulse-width modulation control strategy using the Single Pulse-Width Modulation (SPWM) method with a soft-switching technique for a wide range of output voltages from a bidirectional Dual-Active Bridge (DAB) converter. This method selects two typical inductor current waveforms for soft-switching, and proposes a rule that makes it possible to achieve soft-switching without any compensation algorithm from the waveforms. In addition, both the step-up and step-down conditions are analyzed. This paper verifies that the leakage inductance is independent from the rule, which makes it easier to apply in DAB converters. An integrated algorithm, which includes step-up and step-down techniques, is proposed. The results of experiments conducted on a 50-kW prototype are presented. The system efficiency is experimentally verified to be from 85.6% to 97.5% over the entire range.

특정 고조파 제거를 위한 Cascaded H-bridge 7레벨 인버터의 특성해석 및 시뮬레이션 (Analysis and simulation of Cascaded H-bridge 7 level inverter for eliminating typical harmonic waveforms)

  • 진선호;오진석;조관준;곽준호;임명규;김장목
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1022-1028
    • /
    • 2005
  • This paper is presented the analysis results and simulation results of cascaded H-bridge 7 level inverter with various modulation index. Stepped waveform having number of switching was used to eliminate harmonic components. Switching angles according to modulation index are calculated numerically. Therefore, 3 times of switching with 7 level topology and QWS(Quarter Wave Symmetry) could eliminate 5th and 7th harmonics. The harmonic characteristics are compared to those of space vector modulation method which known as common modulation method in industrial field. Stepped waveform method showed higher ability to reduce, especially lower order of harmonics.

  • PDF

변형 공간벡터방식을 사용한 Z-Source 인버터의 해석 및 제어 (Analysis and Control of Z-Source Inverter using Modified Space Vector Methods)

  • 전태원;황빈트랜;김흥근;노의철
    • 전력전자학회논문지
    • /
    • 제12권4호
    • /
    • pp.332-338
    • /
    • 2007
  • 본 논문은 ZSI에서 shoot-through 시간을 효율적으로 제어하기 위한 변형 공간전압 변조방식으로 3종류를 제시하였다. 3개의 변형 공간전압 변조방식에 대한 스위칭 패턴과 shoot-through 시간변화에 대한 변조신호의 변화를 분석한다. Shoot-through 시간 제어 범위와 함께 스위칭 패턴 및 변조신호의 평형성 등을 고려하여 최적의 변형 공간전압 변조방식을 선정하였으며, 32비트 DSP를 사용한 실험을 통하여 그 타당성을 확인한다.

배전선반송 데이타통신에서의 주기적 임펄스노이즈의 발생특성 (The Originating Characteristics of Periodic Impulse Noises in the Data Communication System by Distribution Line Carrier Method)

  • 최순만;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권2호
    • /
    • pp.75-82
    • /
    • 1994
  • The existence of peroodic impulse noises in distribution line carrier (DLC) communication system is known to be the most serious obstacle for improving DLC communication quality in reliability and capacity. From the spectral points, impulse noises can be divided into baseband type and modulation type the noise width of whichs are much different each other. With each nose type, this study presents the basic characteristics in relation to what they originate from and how their spectrum properties are revealed. The baseband type impulse noise is normally caused from thyristor circuit running with low switching speed and the modulation type noise from the circuit of switching power supply. The base wave of modulation noise is shown to be the pulsuatic charging current to primary condenser in switching power circuit. The study result indicates also that placing the DLC carrier frequency away the band predominated by modulated noise especially from RCC type switching power circuit is very important in DLC design.

  • PDF

Throughput Improvement of an AMQAM Scheme by using New Switching Thresholds over Nakagami-m Fading Channels

  • Lee, Youngkou;Park, Sungsoo;Insoo Koo;Kim, Seung-Geun;Kim, Kiseon
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1440-1443
    • /
    • 2002
  • In this paper, we investigate the throughput improvement of an adaptive M-ary quadrature modulation (AMQAM) scheme by using new switching thresh-olds over slow frequency nonselective Nakagami-m fading channels. The new switching thresholds are obtained by using the approximated BER expressions with complimentary error functions for each modulation scheme given in AWGN channels. By using the new switching thresholds, we can improve the maximum system throughput. For example, we get the maximum throughput improvement about 0.32 when tile target BER is 10$\^$-3/ and the fading figure m = 3.

  • PDF

A Digital Self-Sustained Phase Shift Modulation Control Strategy for Full-Bridge LLC Resonant Converters

  • Zheng, Kai;Zhou, Dongfang;Li, Jianbing;Li, Li;Zhao, Yujing
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.915-924
    • /
    • 2016
  • A digital self-sustained phase shift modulation (DSSPSM) strategy that allows for good soft switching and dynamic response performance in the presence of step variations is presented in this paper. The working principle, soft switching characteristics, and voltage gain formulae of a LLC converter with DSSPSM have been provided separately. Furthermore, the method for realizing DSSPSM is proposed. Specifically, some key components of the proposed DSSPSM are carefully investigated, including a parameter variation analysis, the start-up process, and the zero-crossing capture of the resonant current. The simulation and experiment results verify the feasibility of the proposed control method. It is observed that the zero voltage switching of the switches and the zero current switching of the rectifier diodes can be easily realized in presence of step load variations.

Comparative Study on SVPWM Switching Sequences for VSIs

  • Vivek, G.;Biswas, Jayanta;Nair, Meenu D.;Barai, Mukti
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.133-142
    • /
    • 2018
  • Paper presents a comparative study of space vector pulse width modulation (SVPWM) switching sequences for Voltage Source Inverters (VSIs). Various SVPWM switching sequences are studied for two and three level VSIs in linear modulation index region. The computations of dwell times are presented for two and three level VSIs based on space vector geometry in a synchronized and optimized manner. The existing SVPWM switching sequences are implemented using Matlab / Simulink and in an experimental setup for three phase two and three level VSIs. The simulation and experimental waveforms of conventional SVPWM (CSVPWM) and bus clamped SVPWM (BCSVPWM) are demonstrated for two and three level inverter respectively. The performance of different SVPWM switching sequences are evaluated and presented based on weighted voltage total harmonic distortion (THD).

New Resonant AC Link Snubber-Assisted Three-Phase Soft-Switching PWM Inverter and Its Comparative Characteristics Evaluations

  • Yoshida, Masanobu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.239-248
    • /
    • 2003
  • This paper presents a novel prototype of three-phase voltage source type zero voltage soft-switching inverter with the auxiliary resonant snubbers suitable for high-power applications with IGBT power module packages in order to reduce their switching power losses as well as electromagnetic conductive and radiative noises. A proposed single inductor-assisted resonant AC link snubber circuit topology as one of some auxiliary resonant commutation snubbers developed previously to achieve the zero voltage soft-switching (ZVS) for the three-phase voltage source type sinewave PWM inverter operating under the instantaneous space voltage vector modulation is originally demonstrated as compared with the other types of resonant AC link snubber circuit topologies. In addition to this, its operation principle and unique features are described in this paper. Furthermore, the practical basic operating performances of the new conceptual instantaneous space voltage vector modulation resonant AC link snubber-assisted three-phase voltage source type soft-switching PWM inverter using IGBT power module packages are evaluated and discussed on the basis of switching voltage and current waveforms, output line to line voltage quality, power loss analysis, actual power conversion efficiency and electromagnetic conductive and radiative noises from an experimental point of view, comparing with those of conventional three-phase voltage source hard-switching PWM inverter using IGBT power modules.

전압제어 유도 전동기를 위한 최적 PWM 스위칭 방법 (An Optimized PWM Switching Strategy for an Induction Motor Voltage Control)

  • 한상수;추순남
    • 한국정보통신학회논문지
    • /
    • 제13권5호
    • /
    • pp.922-930
    • /
    • 2009
  • 유도 전동기를 전압 제어하기 위한 최적 PWM 스위칭 방법을 제시하려한다. 전압 인버터의 공간 벡터 변조 방식은 DC-버스 이용을 향상시키고 정류 손실을 감소시키기 때문에 디지털 구현의 경우 특히 선호하는 PWM 방법이다. 유도 전동기 전압 제어를 위한 최적 PWM 스위칭 방법은 제시한 최적 PWM 알고리즘을 사용하여 두 개의 활성 전압 벡터(active voltage vector)와 하나의 영 전압 벡터(zero voltage vector)로 구성하였다. 선택된 스위칭 순차 열은 변조 지수(modulation index)와 운송파(carrier wave) 주기의 함수로 정의 된다. 순차 열은 인버터 스위칭 손실과 전류 리플 값을 기준으로 사용하여 선택된다. 실험 결과 중 저 전력용으로 사용할 경우 스위칭 주파수를 증가시킴에 따라 고조파 왜곡이 감소하고 동특성이 좋아짐을 확인할 수 있었다.