• Title/Summary/Keyword: Switch-control

Search Result 1,253, Processing Time 0.033 seconds

Sensorless Control for Switched Reluctance Motor by Comparing Two Consecutive Switch-on times (인접한 스위치 온 타임 비교를 통한 SRM의 센서리스 제어)

  • Yang, Hyong-Yeol;Kim, Jae-Hyuck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.185-191
    • /
    • 2010
  • This paper describes a new position sensorless control for the switched reluctance motor (SRM) by monitoring the rate of change of current with respect to the inductance variation. Two consecutive switch-on times in hysteresis current control are compared to calculate the rate of change of current and hence to estimate the rotor position and speed. The proposed sensorless control algorithm is simple to implement as it does not depend on extensive computation or additional hardware. Simulation and experimental results are presented to demonstrate the feasibility of the proposed sensorless control method.

A Study on the New Control Scheme of Class-I Inverter for IH-Jar Applications with Clamped Voltage Characteristics Using Pulse frequency Modulation (주파수 변조 기법을 이용한 전압 클램프 특성을 갖는 유도가열용 Class-E 인버터의 새로운 제어에 관한 연구)

  • 이동윤;최영덕;현동석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.3
    • /
    • pp.133-139
    • /
    • 2003
  • In this paper, a new control scheme of Class-E inverter for Induction Heating (IH) Jar applications with clamped voltage characteristics using Pulse-Frequency-Modulation (PFM) is introduced. To reduce the voltage stress of switch, the proposed PFM control scheme doesn't need any auxiliary circuit in comparison to a family of Active Clamped Class-E (ACCE) inverter. It can decrease voltage stress of switch through modulation of switching frequency. The Class-E inverter using the proposed control scheme has the advantage of not only the same output power when it is compared with a Hybrid-Active Clamped Class-E (Hybrid-ACCE) inverter but also Zero-Voltage-Switching (ZVS), which are characteristics of conventional Class-E and ACCE inverter. The control principles and analysis of proposed method are explained in detail and its validity is verified through simulation and experimental results.

A Study on the Main Winding Control of Single Phase Induction Motor using One-Chip Micom (원칩 마이컴을 이용한 단상유도전동기의 주권선 제어에 관한 연구)

  • Park, Su-Gang;Baek, Hyeong-Rae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.1
    • /
    • pp.70-76
    • /
    • 2000
  • This paper describes a one-chip micom controller and phase angle control method for self-starting and energy saving of single-phase induction motor. The proposed method is based on the optimal efficiency control which is running by variable phase angle of main winding current such as to maintain the maximum efficiency characteristics of the motor, in voltage control with TRIAC. Experiments are focused on a capacitor starting single-phase induction motor. The optimal energy saving by variable phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

Performance Analysis of ATM Switch with Priority Control Mechanisms (우선순위제어기능을 가진 ATM스위치의 성능 분석)

  • 장재신;신병철;박권철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.8
    • /
    • pp.1190-1200
    • /
    • 1993
  • In this work, the performance of both delay sensitive traffics and loss sensitive traffics of the output buffered ATM switch with priority control mechanisms has been evaluated. We choose the partial buffer sharing mechanism as the loss priority control mechanism and the HOL(Head Of Line) priority control mechanism as the time priority control mechanism. We model loss sensitive traffics with Poisson process and delay sensitive traffics with MMPP. With loss priority control, it is confirmed that loss probability of loss sensitive traffice decreases when the loss priority control mechanism is chosen. With time priority control, it has also been confirmed that mean cell delay of delay sensitive traffics decreases when the HOL priority control mechanism is used. From this analysis, It has been confirmed that the requirements of QOS for both loss sensitive and delay sensitive traffics can be satisfied in the ATM switch by combining both the loss priority control mechanism and the HOL priority control mechanism.

  • PDF

A Study on the Design and Validation of Switching Mechanism in Hot Bench System-Switch Mechanism Computer Environment (HBS-SWMC 환경에서의 전환장치 설계 및 검증에 관한 연구)

  • Kim, Chong-Sup;Cho, In-Je;Ahn, Jong-Min;Lee, Dong-Kyu;Park, Sang-Seon;Park, Sung-Han
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.7
    • /
    • pp.711-719
    • /
    • 2008
  • Although non-real time simulation and pilot based evaluations are available for the development of flight control computer prior to real flight tests, there are still many risky factors. The control law designed for prototype aircraft often leads to degraded performance from the initial design objectives, therefore, the proper evaluation methods should be applied such that flight control law designed can be verified in real flight environment. The one proposed in this paper is IFS(In-Flight Simulator). Currently, this system has been implemented into the F-18 HARV(High Angle of Attack Research Vehicle), SU-27 and F-16 VISTA(Variable stability. In flight Simulation Test Aircraft) programs. This paper addresses the concept of switching mechanism for FLCC(Flight Control Computer)-SWMC(Switching Mechanism Computer) using 1553B communication based on flight control law of advanced supersonic trainer. And, the fader logic of TFS(Transient Free Switch) and stand-by mode of reset '0' type are designed to reduce abrupt transient and minimize the integrator effect in pitch axis control law. It hans been turned out from the pilot evaluation in real time that the aircraft is controllable during the inter-conversion process through the flight control computer, and level 1 handling qualities are guaranteed. In addition, flight safety is maintained with an acceptable transient response during aggressive maneuver performed in severe flight conditions.

Novel Dual DC-DC Flyback Converter with Leakage-Energy Recycling

  • Yang, Lung-Sheng
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1007-1014
    • /
    • 2018
  • A novel dual DC-DC flyback converter with leakage-energy recycling is presented in this paper. Only an active switch is used for this converter. A pulse-width-modulation strategy is adopeted to control this switch. Two transformers are employed for the proposed converter. During the switch ON-period, the primary windings of the two transformers store energies. At the switch OFF-period, the energies stored in the primary windings of the two transformers are released to the output via the secondary windings of the two transformers. Meanwhile, the leakage energies of the two transformers can be recycled. The operating principles and steady-state analyses of the proposed converter are described in detail. A prototype circuit of the proposed converter is implemented for verifying the performances.

Numerical Analysis of a Flux-Reversal Machine with 4-Switch Converters

  • Lee, Byoung-Kuk;Kim, Tae-Heoung
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.124-128
    • /
    • 2012
  • Many different converter topologies have been developed with a view to use the minimum number of switches in order to reduce construction costs. Among this research, the four-switch converter topology with a novel PWM control technique based on the current controlled PWM method is thought to be a good solution. In this paper, a two dimensional time-stepped voltage source finite-element method (FEM) is used to analyze the characteristics of a Flux-Reversal Machine (FRM) with a 4-switch converter. To validate the proposed computational method, a digital signal processor (DSP) installed controller and prototype FRM are built and experiments performed.

Two Stage Power Factor Correction (PFC) Converter With A Single PWM Controller

  • Park, Hang-Seok;Lee, Kyu-Chan;B.H. Cho
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.252-257
    • /
    • 1998
  • Two-stage power factor correction (PFC) converter with a single PWM controller for universal input voltage (90-264V) is proposed. It consists of a power factor pre-regulator cascaded by a DC/DC converter as in a conventional two-stage approach. However, a single PWM controller is used as in a single-stage, single-switch PFC approach. The switch in the PFC part is synchronized with the switch in the DC/DC converter with a fixed switching frequency. Employing an adaptive delay scheme the switch in the PFC part is controlled to limit the energy storage capacitor voltage within a designed range for the optimum efficiency, and to reduce input current harmonic distortion. The experimental results obtained on a 200W (5V/40A) prototype PFC converter are given to verify the effectiveness of the proposed control method.

  • PDF

Study on the Characteristics on the Heater-Triggered Switch for the Charging of a Superconducting Magnet (초전도자석 충전을 위한 BSCCO 히터트리거 스위치의 특성 연구)

  • 김영식;배덕권;안민철;윤용수;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.196-199
    • /
    • 2003
  • Characteristics of a heater-triggered switch has been analyzed through the simulations and experiments. It was for the charging of Bi-2223 double pancake load with 1.7 mH and two heaters were used. The timing of the sequential control and the heating current with two heaters are important factors to generate pumping-current. The thermal analysis of the switch considering the heater input and time was carried out. Based on the analysis just mentioned. heater-triggered switch was fabricated. Characteristic analysis was carried out through two modes having different sequential timing controls. Maximum pumping-current reached 18 A and the pumping rate was 113 mA/s at that time.

  • PDF

Design and Development of Low-Cost Switched Reluctance Motor Drive System (저가형 스위치드 릴럭턴스 모터 드라이브 시스템 개발)

  • Ha, Keun-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2162-2167
    • /
    • 2009
  • A Low cost and variable speed brushless motor drive system with single switch per phase is presented. The motor drive is realized with a novel two-phase flux-reversal-free switched reluctance motor and a split AC two switch converter. The strategy of the controller and the converter for its realization are described. Comparisons between a split AC converter, asymmetric converter, split DC converter, single controllable switch converter, and N+1 converter are performed for its device rating, cost, switching losses and conduction losses, and converter efficiency. The split AC converter is analyzed and simulated to verify the characteristics of the converter circuitry and control feasibility and the simulation results are presented. The efficiency with various loads is numerically estimated and experimentally compared from viewpoint of subsystem and system in details. The focus of this paper is to compare the presented motor drive system to the asymmetric converter system throughout experiments and demonstrate single switch per phase converter having comparable efficiency as the asymmetric converter system.