• Title/Summary/Keyword: Switch-control

Search Result 1,253, Processing Time 0.033 seconds

A New Energy Recovery Snubber for Boost Converter (부스트 컨버터용 새로운 에너지재생 스너버)

  • 김만고;김진환
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.124-130
    • /
    • 1997
  • The main switch of high-frequency boost converter may be failed because the high switching current or voltage can damage this switch. The high switching stress can be reduced by snubber circuit. In this paper, a new passive snubber circuit which can recover trapped snubber energy without added control is proposed for boost converter. The control of boost converter with proposed snubber is the same as the conventional one. In addition, the energy recovery circuit can be implemented with a few passive components. The analysis for proposed circuit is presented, and the validity of the circuit is verified through simulation and experiment.

  • PDF

Design of Remote Control Electrical Switch Using Embedded Linux (임베디드 리눅스를 이용한 원격 제어 전기 스위치 개발)

  • 박세현;박세훈;노석호
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.788-791
    • /
    • 2004
  • 임베디드 리눅스를 이용한 원격 제어 전기 스위치를 개발한다. 산업 전반에 널리 보급된 인터넷을 이용하여 실시간으로 원격 전기 스위치 기기의 상태를 파악하고 제어함으로서 시간과 공간 및 비용 절감이라는 측면에서 효과를 볼 수 있다. 본 논문에서 설계된 원격 전기 스위치의 서버는 MPC860으로 구성되어 임베디드 리눅스가 포팅되었다. 클라이언트는 서버의 웹 페이지를 접속함으로서 전자 스위치를 원격 관리를 할 수 있게 HTML과 자바로 설계되어 있다. 하나의 서버는 마스트로서 다수의 슬레이브를 가지고 있으며 슬레이브는 전기스위치들과 아날로그 채널로 구성되어 있다.

  • PDF

A Study on the Design of Switch for High Speed Internet Communication Network (고속 인터넷 통신망을 위한 스위치 설계에 관한 연구)

  • 조삼호
    • Journal of Internet Computing and Services
    • /
    • v.3 no.3
    • /
    • pp.87-93
    • /
    • 2002
  • A complex network and a parallel computer are made up of interconnected switching units. The role of a switching unit is to set up a connection between an input port and an output port, according to the routing information. We proposed our switching network with a remodeled architecture is a newly modified Banyan network with eight input and output ports. We have analysed the maximum throughput of the revised switch. Our analyses have shown that under the uniform random traffic load, the FIFO discipline is limited to 70%, The switching system consists of an input control unit, a switch unit and an output control unit. Therefore the result of the analyses shows that the results of the networking simulation with the new switch are feasible and if we adopt the new architecture of the revised model of the Banyan switch, the hardware complexity can be reduced. The FIFO discipline has increased by about 11% when we compare the switching system with the input buffer system. We have designed and verified the switching system in VHDL using Max+plusII. We also designed our test environment including micro computers, the base station, and the proposed architecture. We proposed a new architecture of the Banyan switch for BISDN networks and parallel computers.

  • PDF

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I) (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I))

  • Kim, C.S.;Kim, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.2
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

A Switch Behavior Supporting Effective ABR Traffic Control for Remote Destinations in a Multiple Connection (다중점 연결의 원거리 수신원에 대한 효율적이 ABR 트래픽 제어를 제공하는 스위치 동작 방식)

  • Lee, Sook-Young;Lee, Mee-Jeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.6
    • /
    • pp.1610-1619
    • /
    • 1998
  • The ABR service class provides feedback based traffic control to transport bursty data traffic efficiently. Feedback based congestion control has first been studied to be applied to unicast connections. Recently. several congestion control algorithms for multicast connections have also been proposed as the number of ABR applications requiring multicast increases. With feedback based congestion control, the effectiveness of a traffic control scheme diminishes as propagation delay increases. Especially for a multicast connection, a remote destination may suffer unfair service compared to a local destination due to the delayed feedback. Amelioration of the disadvantages caused by feedback delay is therefore more important for remote destinations in multicast connections. This paper proposes a new switch behavior to provide effective feedback based mathc control for rentoh destinations. The proposed switches adjust the service rate dynamically in accordance woth the state of the downstream, that is, the congestion of the destinaion is immediately controlled by the nearest apstream switch before the source to ramp down the transmission rate of the connection. The proposed switch has an implementation overhead to have a separate buffer for each VC to adjust the service rate in accordance with a backward Rm cell of each VC. The buffer requirement id also increased at intermediate switches. Simulation results show that the proposed switch reduces the cell loss rate in both the local and the remote destinations and slso amelioratd the between the two destinations.

  • PDF

Development of Traffic Centralized Control System Based on Protocol Redirection for DB Protection (DB 보호를 위한 Protocol Redirection기반 트래픽 중앙통제시스템 개발)

  • Su, Yang-Jin;Lee, Jae-Pil;Park, Cheon-O;Lee, Deok-Gyu;Chang, Hang-Bae
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.8
    • /
    • pp.1212-1220
    • /
    • 2010
  • The technologies of domestic user programs are not enough to convert address convert information, which was collected via port redirection server, to user traffic. Generally traffic redirection technology is a special purpose technology for I/O traffic via network device. L4 switch needs various additional costs and devices to achieve this special purpose. To solve this problem, there appears need for a central management of control and monitoring by centralizing traffic at one position regardless of network structure and it is necessary to realize redirection function of switch at network layer. Therefore this study offer development of traffic central control system through protocol redirection of client-side.

A Study on Electric Safety Control Device for Prevention of Over Current and Short Circuit Faults (과전류 및 단락사고 방지용 전기안전 제어장치에 관한 연구)

  • Jo, Si-Hwan;Kwak, Dong-Kurl;Jung, Do-Young;Shim, Jae-Sun;Kim, Jung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2100-2101
    • /
    • 2008
  • This paper is studied on a protective control system for electrical fire and electrical faults due to over current or electric short circuit faults by using electrical thermal characteristics of PTC (Positive Temperature Coefficient) thermistor and current response characteristics of high sensitive reed switch. The PTC thermistor has characteristic of positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with BaTiO3_Ceramics of positive temperature coefficient. Also PTC thermistor shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point, and reed switch, which is used for electrical fault current sensing devices, have a excellent characteristic of response velocity in degree of ${\mu}s{\sim}ms$ that sensing magnetic flux in proportion to dimension of line current. This paper is proposed on a protective control system use PTC thermistor and reed switch for sensor which is protected from electrical fire due to overload faults or electric short circuit faults. Some experimental results of the proposed electric safety control device are confirmed to the validity of the analytical results.

  • PDF

Development of a Lighting Control Switch Using Power Line Communication Technology (전력선 통신기술을 이용한 조명제어 스위치의 개발)

  • Song Jae-yong;Moon Seung-bo;kil Gyung-suk;Lee Gyung-soo;Kim Chang-yul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.4
    • /
    • pp.792-797
    • /
    • 2005
  • Lighting control switches based on the power line communication technology are developed and extended to incorporate dimming control to provide energy saving and appropriate illumination. The developed switch uses a general purpose microprocessor and associated electronics. Both the power line communication and the dimming function are implemented in one microprocessor, and it enables the low price commercialization. The frequency of the carrier was set at 250kHz considering the transmission data length and signal attenuation in power lines. Tests on prototypes in an low-voltage power lines have shown that the switches have a robust operation characteristics with the length of power lines and the variation of load capacities.

A Fault Tolerant Structure and Control Strategy for Electromagnetic Stirring Supplies

  • Li, Yan;Luo, An;Xiang, Xinxing;Chen, Yandong;He, Zhixing;Zhou, Fayun;Chen, Zhiyong
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1256-1267
    • /
    • 2017
  • A fault tolerant structure and its corresponding control strategy for electromagnetic stirring power supplies are proposed in this paper. The topology structure of the electromagnetic stirring power supply contains two-stages. The fore-stage is the PWM rectifier. The back-stage is the fault tolerant inverter, which is a two-phase three-bridge orthogonal inverter circuit while operating normally. When the power switch devices in the inverter are faulty, the structure of the inverter is reconfigured. The two-phase half bridge inverter circuit is constructed with the remaining power switch devices and DC-link capacitors to keep the system operating after cutting the faulty power switch devices from the system. The corresponding control strategy is proposed to let the system work under both normal and fault conditions. The reliability of the system is improved and the requirement of the electromagnetic stirring process is met. Finally, simulation and experimental results verify the feasibility of the proposed fault tolerant structure and corresponding control strategy.