• 제목/요약/키워드: Switch Point

검색결과 242건 처리시간 0.026초

최적의 모드 결합을 얻기 위해 수정된 결합 영역을 갖는 전기광학 폴리머 디지탈 광스위치의 해석 (Analysis of electro-optic polymer digital optical switch with a coupling region modified for optimum mode coupling)

  • 이상신;신상영
    • 전자공학회논문지D
    • /
    • 제34D권4호
    • /
    • pp.87-93
    • /
    • 1997
  • An electro-optic polymer digital optical switch with a coupling region modified for optimum mode coupling is proposed, and it is analyzed by using the beam propagation method combined with the effective index method. Its modified coupling region is adiabatically introduced along the propagation direction from the branching point of the two waveguides. The structure of the modified coupling region and its refractive index profiles are designed to optimize the mode coupling in the Y-branch waveguide. Therefor, the switching performance of the device may be enhanced with a fixed device length. It is confirmed from the numerical calculation that the drive voltage is reduced by more than 30 percents and te crosstalk is improved by about 8dB.

  • PDF

텅레일 밀착력 측정기 개발에 관한 연구 (Study on developing CSEM Sratch Tester of tongue rail)

  • 이남일;고양옥;정호형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1663-1668
    • /
    • 2010
  • The terms of track is a train-only line for a train service, in premises of station of a station, that the unit over the track for turnout the track from one track to another track, which it changes the course from the main track that is used for operating a train to the side track, is called a turnout The stick strength of tongue rail is adjusting uniform pressure on the both sides, the adhesion strength between a basic rail and tongue rail has to maintain over 100kg of power value to open over 1mm the ends. This study suggested developing a measuring instrument that can measure a basic rail and the stick strength of a movable rail in according with a switch, such as a switch point, and a performance test. This study ties to be helped that it improves measuring usability for the maintainers through improving quality in a stick measuring instrument, that it solves a technique in the site difficulties through improving a measuring instrument, with reducing the obstacles and expenses.

  • PDF

네온사인 기능을 수행하는 형광램프용 전자식 스타터 (A Electronic Starter for Fluorescent Lamps for use as Neon Signs)

  • 송상빈;곽재영;여인선;임건호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.228-233
    • /
    • 1999
  • In this paper we develop an electronic starter circuit that is suitable for Neon sign operation of switch-start fluorescent lamps. The developed starter enable single pulse ignition of fluorescent lamp at the peak point of preheating current, irrespective of the position of the Tum-On signal. This is possible due to the sequential operation of two transistors different in their operation characteristics and a diode operation characteristic. The switching endurance test using this starter has been carried for more than 3000 hours for a single switch-start on a severe blinking condition of preheating of 0.1s and of successive lighting interval of 0.1s.

  • PDF

PWM 스윗치 모델을 이용한 PV용 Boost Converter Modelling (Boost Converter Modeling of Photovoltaic System Using PWM Switch Model)

  • 김효진;이기옥;최주엽;정영석;유권종;권종덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.286-293
    • /
    • 2002
  • Photovoltaic systems normally use a maximum power point tracking (MPPT) technique to continuously deliver the highest possible power to the load when variations in the insolation and temperature occur. A simple method of tracking the maximum power points (MPPs) and forcing the boost converter system to operate close to these Points is presented through deriving small-signal model and transfer function of boost converter. This paper aims at modeling boost converter including equivalent series resistance of input reservoir capacitor by state-space-averaging method and PWM switch model. In the future, properly designed controller for compensation will be constructed in real system for maximum photovoltaic power tracking control.

  • PDF

알루미늄 호일 퓨즈를 이용한 펄스 압력발생 및 이용기술 개발 (A Development of the Rotary Arc Gap Switch for Pulsed High Current Transfer)

  • 조주현;임근희;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2242-2244
    • /
    • 1999
  • Recently, An important research field of pulsed power is high voltage, high power generation with exploding wire opening switch. Another point of view exploding wire effects have been researched for generation of the pulsed high pressure shock wave. Theoretical considerations of the shock pressure generation along with experiment results are presented in this paper and. Some experimental results of hard rock fracturing show the possibilities of commercial using.

  • PDF

4스위치 3상 인버터의 직류 링크 중성점 전압 추정에 의한 출력전압 불평형 개선 (Improvement of Output Voltage Waveforms by DC-Link Neutral Point Voltage Estimation for FSTPI)

  • 김정훈;조인철;이홍희
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1741-1749
    • /
    • 2009
  • It is very important to maintain the balanced output voltage waveforms under the unbalanced DC-link voltages in the four-switch three-phase inverter(FSTPI). In this paper, the improvement of output voltage waveforms is proposed with the aid of DC-link voltage ripple estimation. The proposed method can be implemented without the additional voltage sensor. The proposed method applied to the permanent magnet synchronous motor (PMSM) is simulated and experimented in order to verify its feasibility.

배전계통 리클로우저 기반의 자율적 고장복구 방법론 (The Self-Fault Restoration Methodology based on the Recloser in the Distribution Systems)

  • 고윤석
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1681-1688
    • /
    • 2009
  • This paper proposes a new fault restoration method which adopts the recloser as top agent to release the problems of the data concentration and fault processing delay of the existing DAS(distribution Automation System) under the ubiquitous distribution system. In proposed method, top agent collects the data based on the multi-casting communication with the tie switches of the interconnection point, and then selects a closed switch(tie switch) to transfer the sound outage load to other feeders based on the heuristic search strategy step by step until the load transfer work is finished. Here, a new heuristic rule is developed which can guarantee the relational load balancing and line loss from the collected voltage data. Finally, the several faults are simulated for typical multi-section and multi-interconnection distribution system to prove the effectiveness of the proposed strategy, in particular, for each simulation cases, the load balancing index and line loss index of the obtained solution from the proposed method is compared with those of all of feasible solutions.

다단 맥류 스위칭을 이용한 교류-직류 변환의 성능분석 (Performance Analysis of the AC-DC Transformation Method using Multi-level Pulsating Current and Selection Switch)

  • 이재생
    • 한국군사과학기술학회지
    • /
    • 제13권4호
    • /
    • pp.586-593
    • /
    • 2010
  • In this paper, I have proposed that the 1st and 2nd AC-DC transformation methods using multi-level pulsating currents and selection switches. Through making the rectified voltage of the proposed AC-DC translation which is similar to reference voltage by selecting from multi-level pulsating currents, the proposed translation has dramatically reduced the ripple voltage. I have compared the performance of the DC voltage, the ripple voltage and the peak to peak voltage of the proposed method with the conventional method. The simulation results show that the proposed 2nd method has the better performance than the 1st method in the point of average DC voltage drop and peak to peak voltage increase.

Design of a Microcontroller Based Electronic Load Controller for a Self Excited Induction Generator Supplying Single-Phase Loads

  • Gao, Sarsing;Murthy, S. S.;Bhuvaneswari, G.;Gayathri, M. Sree Lalitha
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.444-449
    • /
    • 2010
  • The generation of electric power using self excited induction generation (SEIG) is a viable option in remote and rural areas where grid electricity is not available. The generated voltage and frequency of these machines, however, varies with varying loads. This characteristic can be resolved either by adjusting the values of the excitation capacitance or by controlling the prime mover speed. Further, in a single-point constant power application, where the machines deliver a fixed amount of power, the electronic load controller (ELC) can be used to switch-in or switch-out a dump load whenever the consumer load decreases or increases respectively. This paper presents a detailed analysis and the design of a microcontroller based SEIG -ELC system intended for stand-alone pico hydro power generation. The simulated performance of the controller is supplemented by experimental results.

Framework for Multimedia Service using Multicast in CVCN Network

  • Woo, Yoseop;Kim, Iksoo
    • 한국정보기술학회 영문논문지
    • /
    • 제9권2호
    • /
    • pp.55-63
    • /
    • 2019
  • Vehicle communication networks have some deficient network resources to support a vast multimedia service including safety driving information, video, news and some broadcast relayed from the playgrounds such as professional baseball games for autonomous vehicles. This paper deals with the framework for providing seamless multimedia service including safety driving information using multicast in cooperated-connected vehicle communication network (CVCN). It adopts smart-switch (SS) and smart intelligent multicast agent(SIMA) to support the seamless multimedia service. The SS manages and switches multimedia streams through SIMA in CVCN network. The SIMA to operate as an access point, is composed of multicast supporting part and control part of mobile devices/autonomous vehicles in CVCN network. Therefore this proposed technique using SS and SIMA within CVCN network is a new framework for multimedia service that can disperse the load of server.