A Study on Switching Power Measurement of an Electrical Point Machine Using a Sensor (센서를 활용한 전기선로전환기의 전환력 측정에 대한 연구)

  • Lee, Jong-Hyun;Kim, Yong-Kyu
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.4
    • /
    • pp.335-343
    • /
    • 2015
  • The role of the turnouts installed on the points of railway branches and intersections is to safely switch the directions of trains. In case of abnormal forces applied to the turnouts due to extreme operating conditions, it is difficult in the current system to conduct accurate diagnosis and measuring. Moreover, the existing measurement devices for turnout switching power are mostly based on foreign technologies, which provide only limited information on the switching power; this information is insufficient for effective monitoring and maintenance. In this paper, through an analysis of the characteristics of the switching and locking function, the problems in turnout power measurements of current electrical point machines in Korea are examined. And based on the results, a new sensor-based method for measuring switching power is proposed.

New hysteresis current control for induction motor drive with NPC inverter (NPC 인버터에 의한 유도전동기 구동시스템의 새로운 히스테리시스 전류 제어기법)

  • 김춘삼;이병송
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 1999
  • A new current controlled PWM t'||'&'||'pound;rlmique with NPC(Neutral Point Qarll)ed) structure is IrOIX>Sed in this paper. A current controlled PWM technique with neutral-JXlint-cIamped pulse-width modulation inverter composed of main switching devices which operates as switch for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. The proposed current controller has a first and second current band The switching pattern will be made by the first current band. According to the second current band, the output state of the switching pattern is changed into positivee and negative state. This inverter output contains less hanronic content and lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Thbe induction machine drive with proposed technique is investigated by commputer simulation.

  • PDF

A Novel Fault Detection Method of Open-Fault in NPC Inverter System (NPC 인버터의 개방성 고장에 대한 새로운 고장 검출 방법)

  • Lee, Jae-Chul;Kim, Tae-Jin;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.115-122
    • /
    • 2007
  • In this paper, a novel fault detection method for fault tolerant control is proposed when the NPC inverter has a open failure in the switching device. The open fault of switching device is detected by checking the variation of a leg-voltage in the neutral-point-clamped inverter and the two phases control method is used for continuously balance the three phases voltage to the load. It can be achieve the fault tolerant control for improving the reliability of the NPC inverter by the fault detection and reconfiguration. This method has fast detection ability and a simple realization for fault detection, compared with a conventional method. Also, this fast detection ability improved the harmful effects such as DC-link voltage unbalance and overstress to other switching devices from a delay of fault detection. The proposed method has been verified by simulation and experiment.

The Determinants of Switching On·Off-Line Channels for Consumers (소비자의 온·오프라인 채널이동 유형의 결정요인에 대한 연구)

  • Jun, Sangmin
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.245-256
    • /
    • 2013
  • This study illustrates factors that determine consumer types based on ways in which they alternate between online and offline channels for searching and eventually buying their desired products. This study conducted an online survey targeting 1,040 consumers. As per the study, consumer types fall into five groups: 1) on-on type(online search${\rightarrow}$online buying), 2) off-off type(offline search${\rightarrow}$offline buying), 3) on-off type(online search${\rightarrow}$offline buying), 4) off-on type(offline search${\rightarrow}$online buying), and, 5) on-off-on type(online search${\rightarrow}$ offline search${\rightarrow}$nline buying). The primary factors that determine how the different consumer types switch between online and offline channels are price orientation, convenience orientation,, risk-aversion orientation, and channel familiarity. Although they feel cross-channel shopping can be cumbersome, the findings show that cross-channel consumers would gladly switch channels to buy cheaper and proven products. The findings of this study will be useful for businesses that have both online and offline channels and point out the theoretical aspects of the decision-making process as consumers switch between channels.

Control and Analysis of an Integrated Bidirectional DC/AC and DC/DC Converters for Plug-In Hybrid Electric Vehicle Applications

  • Hegazy, Omar;Van Mierlo, Joeri;Lataire, Philippe
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.408-417
    • /
    • 2011
  • The plug-in hybrid electric vehicles (PHEVs) are specialized hybrid electric vehicles that have the potential to obtain enough energy for average daily commuting from batteries. The PHEV battery would be recharged from the power grid at home or at work and would thus allow for a reduction in the overall fuel consumption. This paper proposes an integrated power electronics interface for PHEVs, which consists of a novel Eight-Switch Inverter (ESI) and an interleaved DC/DC converter, in order to reduce the cost, the mass and the size of the power electronics unit (PEU) with high performance at any operating mode. In the proposed configuration, a novel Eight-Switch Inverter (ESI) is able to function as a bidirectional single-phase AC/DC battery charger/ vehicle to grid (V2G) and to transfer electrical energy between the DC-link (connected to the battery) and the electric traction system as DC/AC inverter. In addition, a bidirectional-interleaved DC/DC converter with dual-loop controller is proposed for interfacing the ESI to a low-voltage battery pack in order to minimize the ripple of the battery current and to improve the efficiency of the DC system with lower inductor size. To validate the performance of the proposed configuration, the indirect field-oriented control (IFOC) based on particle swarm optimization (PSO) is proposed to optimize the efficiency of the AC drive system in PHEVs. The maximum efficiency of the motor is obtained by the evaluation of optimal rotor flux at any operating point, where the PSO is applied to evaluate the optimal flux. Moreover, an improved AC/DC controller based Proportional-Resonant Control (PRC) is proposed in order to reduce the THD of the input current in charger/V2G modes. The proposed configuration is analyzed and its performance is validated using simulated results obtained in MATLAB/ SIMULINK. Furthermore, it is experimentally validated with results obtained from the prototypes that have been developed and built in the laboratory based on TMS320F2808 DSP.

Structure Optimization and 3D Printing Manufacture Technology of Pull Cord Switch Components Applied to Power Plant Coal Yard (발전소 저탄장에 적용되는 풀코드스위치 부품의 구조최적화 3D 프린팅 제작기술 개발)

  • Lee, Hye-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.319-330
    • /
    • 2016
  • Recently, 3D printing technology has been applied to make a concept model and working mockup of an industrial application. On the other hand, this technology has limited applications in industrial products due to the materials and reliability of the 3D printed product. In this study, the components of a full cord switch module are proposed as a case of a 3D printed component that can be used as a substitute for a short period. These are hub-driven and lever lockup components that have the structural characteristics of breaking down frequently in the emergency operating status. To ensure the structural strength for a substitute period, research of structure optimization was performed because 3D printing technology has a limitation in the materials used. After optimizing the structure variables of the hub-driven component, reasonable results can be drawn in that the safety factors of the left and right switching mode are 1.243 (${\Delta}153.67%$) and 3.156 (${\Delta}404.96%$). The lever lockup component has a structural weak point that can break down easily on the lockup-part because of a cantilever shape and bending moment. The rib structure was applied to decrease the deflection. In addition, optimization of the structural variables was performed, showing a safety factor of 7.52(${\Delta}26%$).

A Study on the Ignition Distance from a Leakage Point of the LP Gas Pipe (LP 가스 배관의 누출부로부터 점화가능 거리에 관한 연구)

  • Ryou, Young-Don;Kim, Young-Gu;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.70-76
    • /
    • 2017
  • The standards related to the "Urban Gas Business Act" and the "Safety Control and Business Regulation of Liquefied Petroleum Gas Act" prescribe the separation distance between gas piping joint excluding welded joints and electric equipments(electric switch, watt meter, breaker, connector, etc). The "Korea Electro technical Regulation" also prescribes the distance between gas piping joints and electric equipments in accordance with the gas related standards. In case of the standards related to the "Urban Gas Business Act", the distance criteria stipulated in the standard of supplying facilities are different from those stipulated in the standard of using facilities. In this study, we have conducted pilot test on the possible ignition distance from the piping joint when LP gas is leaked from the point. We have also examined the adequacy of current standards on the separation distance between gas piping joint and electric equipments. As a result of the tests, we have found that ignition is able to occur at a distance of 30 cm as stipulated in the current standards or more when LP gas is leaked from the joint of the pipe. Therefore, we have made a decision that the criteria for separation distance between gas piping joint and electric equipment specified in the current standards related to the "Urban Gas Business Act" and the "Safety Control and Business Regulation of Liquefied Petroleum Gas Act" is appropriate.

A Fairness Control Scheme in Multicast ATM Switches (멀티캐스트 ATM 스위치에서의 공정성 제어 방법)

  • 손동욱;손유익
    • Journal of KIISE:Information Networking
    • /
    • v.30 no.1
    • /
    • pp.134-142
    • /
    • 2003
  • We present an ATM switch architectures based on the multistage interconnection network(MIN) for the efficient multicast traffic control. Many of these applications require multicast connections as well as point-to-point connections. Muiticast connection in which the same message is delivered from a source to arbitrary number of destinations is fundamental in the areas such as teleconferencing, VOD(video on demand), distributed data processing, etc. In designing the multicast ATM switches to support those services, we should consider the fairness(impartiality) and priority control, in addition to the overflow problem, cell processing with large number of copies, and the blocking problem. In particular, the fairness problem which is to distribute the incoming cells to input ports smoothly is occurred when a cell with the large copy number enters upper input port. In this case, the upper input port sends before the lower input port because of the calculating method of running sum, and therefore cell arrived into lower input port Is delayed to next cycle to be sent and transmission delay time becomes longer. In this paper, we propose the cell splitting and group splitting algorithm, and also the fairness scheme on the basis of the nonblocking characteristics for issuing appropriate copy number depending on the number of Input cell in demand. We evaluate the performance of the proposed schemes in terms of the throughput, cell loss rate and cell delay.

Micro-scale Solar Energy Harvesting System with a New MPPT control (새로운 MPPT 제어기능을 갖는 마이크로 빛에너지 하베스팅 회로)

  • Yoon, Eun-Jung;Yoon, Il-Young;Choi, Sun-Myung;Park, Youn-Soo;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2627-2635
    • /
    • 2013
  • In this paper micro-scale solar energy harvesting system with a new MPPT control are proposed. In conventional solar energy harvesting systems, continuous perturbation techniques of the clock frequency or duty cycle of a power converter have been used to implement MPPT(Maximum Power Point Tracking) control. In this paper, we propose a new MPPT technique to control the duty cycle of a power switch powering a power converter. The proposed circuit is designed in $0.35{\mu}m$ CMOS process, and the designed chip area including pads is $770{\mu}m{\times}800{\mu}m$.

Overlapping Effects of Circular Shift Communication and Computation (원형 쉬프트 통신의 중첩 효과 분석)

  • Kim, Jung-Hwan;Rho, Jung-Kyu;Song, Ha-Yoon
    • The KIPS Transactions:PartA
    • /
    • v.9A no.2
    • /
    • pp.197-206
    • /
    • 2002
  • Many researchers have been interested in the optimization of parallel programs through the latency hiding by overlapping the communication with the computation. We ana1yzed overlapping effects in the circular shift communication which is one of the collective communications being frequently used In many data parallel programs. We measured the time which can be possibly overlapped and the time which cannot be overlapped in over all circular shift communication period on an Ethernet switch-based clustered system. The result from each platform nay be used for the input of optimizing compilers. The previous performance models usually have two kinds of drawbacks one is only based on point-to-point communication, so it is not appropriate for analyzing the overall effects of collective communications. The other provides the performance of collective communication, but no overlapping effect. In this paper we extended the previous models and analyzed the experimental results of the extended model.