• 제목/요약/키워드: Switch Point

검색결과 242건 처리시간 0.028초

은행서비스 산업에서 범주형 회귀분석을 이용한 지속적 거래의도 평가 (An Empirical Evaluation of Continuous Transaction Intents Using Categorial Regression in the Banking Industry)

  • 하홍열
    • 한국경영과학회지
    • /
    • 제37권3호
    • /
    • pp.1-12
    • /
    • 2012
  • The research mainstream has focused on improving the competitiveness throughout the reinforcement of customer satisfaction and loyalty in the banking industry, but there is still a lack of research that reflects characteristics of banking services. From a customer point of view, this study considers a variety of bank characteristics such as levels of interest rate, numbers of transaction banks, monthly average balance, and age. In line with this observation, the main objective of the current research is to investigate the relationship between bank characteristics and ongoing transaction intentions with a particular bank using a categorial regression analysis and in turn, provide insights for managers. First, the findings show that deposit interest rate is insignificant for leading customers to ongoing transaction intentions, but loan interest rate is significant when customers are satisfied with a loan interest rate. Second, if customers only transact their banking services with a particular bank, they are more likely to deal with the bank, rather than customers who transact additional one or two banks. Third, in the case of monthly average balance, customers who have more than \100 million wons per month are likely to switch other competitors. Finally, old customers are more stable than young customers when they consider to switch the relationship with a bank. The author provides insights for bank managers and discusses research limitations and further directions of the study.

Pulse Density Modulated ZVS High Frequency Inverter with Reverse Blocking Single Switch for Dielectric Barrier Discharge Lamp Dimming

  • Sugimura Hisayuki;Yasui Kenji;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.206-209
    • /
    • 2006
  • At present, the cold cathode fluorescent lamp (CCFL) using mercury lamp has been generally used far liquid crystal backlight source of personal computer and car navigation and so on. This kind of lamp is more excellent on luminance performance and cost. However, the requirements of liquid crystal backlight due to a light source without mercury have been strongly increased from a viewpoint of the actual influence on environmental preservation and environmental recycling. As fluorescent lamp without mercury, Dielectric Barrier Discharge based rare gas fluorescent lamp (DBD-FL) using xenon (Xe) gas has been studied so far. This DBD lamp has no influence on the human body and environmental recycle. Its operating life is long because electrode is out. In this paper, the simulation and experimental results of soft switching high frequency inverter with reverse blocking single switch as a high frequency power supply circuit for DBD-FL using Xe gas are comparatively evaluated and discussed from a practical point of view.

  • PDF

무선 ATM LAN 시스템에서 이동 단말에 의한 핸드오버 제어 기법 (Handover Control Scheme Initiated by the Mobile Terminal in Wireless ATM LAN System)

  • 박남훈;김영선;최준균;감상하
    • 한국정보처리학회논문지
    • /
    • 제7권4호
    • /
    • pp.1236-1245
    • /
    • 2000
  • This paper propose a novel scheme, called Mobiel Terminal Initiated Scheme(MTIS), in which mobile terminal initiates the backward handover by sending handover request message with the list of target radio ports. In this scheme, the old ATM switch suporting end-user mobility, denoted by EMAS\ulcorner, checks whether each EMAS\ulcorner, managing the target radio port, has its available resources. If it has, the EMAS\ulcorner performs the path rerouting between CrossOver Switch (COS) and itself after deciding the most suitable target radio port. Therefore, the MT initiates the handover after deciding the most suitable target radio port through the beacon signal of Wireless Access Point (WAP). The EMAS\ulcorner have only to check the resource availability of the target radio port. It is no need to waste time to decide the suitable target radio port. Also, once receiving the request of the resource availability, the EMAS\ulcorner can reduce the rerouting delay time due to perform the path rerouting to the COS. In comparison with that of the ATM-Forum procedure, our proposed MTIS handover delay time reduced 14~21%, and end-to-end transfer delay time reduced 2~9%, as a result of the simulation.

  • PDF

직접접촉식 RF MEMS 스위치에서의 미소용접 현상 억제 (Suppression of Microwelding on RF MEMS Direct Contact Switches)

  • 이태원;김성준;박상현;이호영;김용협
    • 한국항공우주학회지
    • /
    • 제33권4호
    • /
    • pp.41-46
    • /
    • 2005
  • 본 연구에서는 고 전력의 RF 신호용 직접 접촉식 스위치에서 문제가 되고 있는 접촉부위에서의 미소용접에 의한 점착 현상을 감소시키기 위해, 고 융점 금속인 텅스텐(W)과 몰리브덴(Mo)을 스위치 접촉 부위에 코팅하여 스위치의 성능을 분석하였다. 스위치의 삽입손실과 신호격리도, 전력 손실 등의 변화를 네트워크 분석기, 전력 측정기 등을 통하여 측정하였다. 측정결과로부터 RF 신호 전송에 있어서 낮은 입력 전력에서는 고융점 금속이 금(Au)보다 접촉저항이 더 크지만 입력 전력이 커지면 비교적 낮은 비저항의 고융점 금속을 사용하는 것이 고전력 전송 및 수명 연장에 있어서 유리함을 밝혀냈다.

Split-Capacitor Dual-Active-Bridge 컨버터 (Split-Capacitor Dual-Active-Bridge Converter)

  • 김기수;박시호;차헌녕;최병조
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.352-358
    • /
    • 2018
  • A split-capacitor (SC) dual-active-bridge (DAB) converter is proposed in this study. The DC-link capacitors of input and output are split in the proposed converter. The primary and secondary windings of transformer are connected to the midpoints of the DC-links. Hence, the SC DAB converter can inherently prevent transformer from saturation. Although the switch current stress of the proposed converter is twice that of the conventional DAB converter, the switch voltage stress is reduced by half. Therefore, the proposed converter can reduce switching loss and achieve high efficiency in a high switching frequency. Given the SC structure, the proposed converter can readily be connected to neutral-point-clamped- or half-bridge-type converters. The topology of the proposed converter is presented and the operating principle is analyzed in detail. A 3-kW hardware prototype was built and tested to verify the performance of the proposed converter.

진동장치를 이용한 기능성 스마트 팬츠 개발 및 평가 (Development and Evaluation of Smart Pants with Vibrating Devices)

  • 최선윤;이정란
    • 한국의류산업학회지
    • /
    • 제11권1호
    • /
    • pp.121-129
    • /
    • 2009
  • Nowadays, global interest is being placed on research and development of smart clothing which is expected to create a high added-value industry in the future. The purpose of this research is to develop smart pants with vibrating massage functions that have excellent outer appearances and provide comfort to wearers and assess outer appearance, comfort, and massaging effects of smart pants. As the results of this research, smart pants where vibrating devices which are mainly composed of vibrating motor, controller, and switch are attached were completed. Vibrating motors were fixed on a thin and light non-woven fabric material, covered with a mesh material, and attached by snaps to the experiment pants. Switch was attached to the inside of a pocket, and batteries were positioned inside of pockets. Ten subjects marked their satisfaction of wearing smart pants on a 5-point scale. Noticeable changes in outer appearance when vibrating motors operate turned out to be low. Wearer's comfort in back waist and front thigh parts where vibrating motors were attached turned out to be high-satisfied. Massaging effects of smart pants turned out to be high. Attaching and detaching vibrating devices turned out to be convenient. Lining materials used for smart paints were effective in blocking electromagnetic waves generated from vibrating devices.

Electrically-induced actuation for open-loop control to cancel self-excitation vibration

  • Makihara, Kanjuro;Ecker, Horst
    • Smart Structures and Systems
    • /
    • 제9권2호
    • /
    • pp.189-206
    • /
    • 2012
  • This paper focuses on the actuation system combined with a piezoelectric transducer and an electric circuit, which leads to a new insight; the electric actuation system is equivalent to mechanical variable-stiffness actuation systems. By controlling the switch in the circuit, the electric status of the piezoelectric transducer is changed, and consequently a variable-stiffness mechanism is achieved on the electric actuator. This proposed actuator features a shift in the equilibrium point of force, while conventional electrically-induced variable-stiffness actuators feature the variation of the stiffness value. We intensively focus on the equilibrium shift in the actuation system, which has been neglected. The stiffness of the variable-stiffness actuator is periodically modulated by controlling the switch, to suppress the vibration of the system in an open-loop way. It is proved that this electric actuator is equivalent to its mechanical counterpart, and that the electrical version has some practical advantages over the mechanical one. Furthermore, another kind of electrically-induced variable-stiffness actuator, using an energy-recycling mechanism is also discussed from the viewpoint of open-loop vibration control. Extensive numerical simulations provide comprehensive assessment on both electrically-induced variable-stiffness actuators employed for open-loop vibration control.

모드 결합을 최적화 하기 위해 수정된 결합 영역을 갖는 전기광학 폴리머 디지탈 광스위치 (Polymeric digital optical switch with a coupling region modified for optimum mode coupling)

  • 이상신;신상영
    • 한국광학회지
    • /
    • 제8권3호
    • /
    • pp.245-249
    • /
    • 1997
  • 본 논문에서는 모드 결합을 최적화하기 위해 수정된 결합 영역을 갖는 전기광학 폴리머 디지탈 광스위치를 제작하였다. 분기형 도파로는 반응이온식각 방법을 이용하여 만들었다. 그리고, 수정된 결합 영역은 두 광도파로의 분기점에서부터 광파의 진행 방향을 따라 점진적으로 도입하였으며, 소자 제작 이후에 광표백 방법을 이용하여 구현하였다. 분기 영역에서 두 도파로 간의 모드 결합이 최적화 되도록 수정된 결합 영역의 구조와 굴절률 분포를 조절함으로써, 소자의 길이가 고정되어 있는 상태에서 스위칭 성능을 향상시켰다. 측정 결과에 의하면, 구동 전압은 약 30%이상 감소되었으며 누화는 4~6 dB정도 개선되었다.

  • PDF

군집화 기법을 이용한 GIS 열화 패턴 연구 (A Study on Degradation Pattern of GIS Using Clustering Methode)

  • 이덕진
    • 한국전기전자재료학회논문지
    • /
    • 제31권4호
    • /
    • pp.255-260
    • /
    • 2018
  • In recent years, increasing electricity use has led to considerable interest in green energy. In order to effectively supply, cut off, and operate an electric power system, many electric power facilities such as gas insulation switch (GIS), cable, and large substation facilities with higher densities are being developed to meet demand. However, because of the increased use of aging electric power facilities, safety problems are emerging. Electromagnetic wave and leakage current detection are mainly used as sensing methods to detect live-line partial discharges. Although electromagnetic sensors are excellent at providing an initial diagnosis and very reliable, it is difficult to precisely determine the fault point, while leakage current sensors require a connection to the ground line and are very vulnerable to line noise. The partial discharge characteristic in particular is accompanied by statistical irregularity, and it has been reported that proper statistical processing of data is very important. Therefore, in this paper, we present the results of analyzing ${\Phi}-q-n$ cluster distributions of partial discharge characteristics by using K-means clustering to develop an expert partial discharge diagnosis system generated in a GIS facility.

전압형 PWM 인버터의 새로운 고장 검출 기법 (A Novel Fault Detection Scheme for Voltage Fed PWM Inverter)

  • 유옥선;박남주;현동석
    • 전력전자학회논문지
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 2007
  • 본 논문에서는 각종 산업분야에서 매우 중요한 전력전자 시스템의 신뢰성을 향상시키기 위해 전압형 인버터 시스템의 새로운 고장 검출 기법을 제안한다. 제안한 기법은 인버터 시스템의 스위치 고장 발생시에 각 상의 하단 스위치에 나타나는 전압 이상을 검출하여 고장을 판단한다. 시스템의 재구성 방법은 고장이 발생한 상을 양방향 스위치에 의해 직류-링크 중성점과 연결함으로서 4-스위치 구동으로 구성한다. 제안한 고장 검출기법은 간단한 알고리즘으로 구현되며 빠른 고장 검출이 가능하다는 장점을 갖는다. 그러므로 고장 발생 후에도 빠른 시스템 재구성을 통해 연속적인 시스템 운영이 가능하다. 제안한 고장 검출과 고장 허용 시스템의 우수성은 시뮬레이션을 통하여 검증되었다.