• Title/Summary/Keyword: Swing Phase Control

Search Result 69, Processing Time 0.034 seconds

A Study on the Characteristics of Gait in Patients with Chronic Low Back Pain (만성요통환자의 보행특성에 관한 연구)

  • Kim, Kyoung;Ko, Joo-Yeon;Lee, Sung-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.79-85
    • /
    • 2009
  • Purpose: This study examined the characteristics of gait in patients with chronic low back pain. Methods: The subjects were out-patients suffering from chronic low back pain at the department of physical therapy, B hospital in Seoul. Gait analysis was performed by dividing the subjects into two groups. The study and control group comprised 15 chronic low back pain patients and 14 healthy people, respectively. Gait analysis was performed using a VICON 512 Motion Analysis System to obtain the spatio-temporal and kinematic parameters. Results: First, there was a significant difference in the spatio-temporal parameters between the two groups (p<0.05). Second, the study group showed significant differences in the kinematic parameters during the stance phase (p<0.05). Third, there were significant differences in kinematic parameters in the study group during the swing phase (p<0.05). Conclusion: The gait pattern of patients with chronic low back pain is characterized by more rigid patterns. Compared to the control group, there was a decrease in the spatio-temporal parameters and kinematic parameters in patients with chronic low back pain. These findings are expected to play a role as basic data and to form a rehabilitation program for low back pain patients.

  • PDF

The 3-D Motion Analysis of Kinematic Variety on Lower Extremity during Ramp Ascent at Different Inclinations (정상인의 오름 경사로 보행 시 경사각에 따른 하지 관절의 삼차원적 동작 분석)

  • Han, Jin-Tae;Lee, Jong-Dae;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.633-650
    • /
    • 2005
  • The aim of this study was to investigate the kinematics of young adults during ascent ramp climbing at different inclinations. Twenty-three subjects ascended a four step at four different inclinations(level, $8^{\circ},\;16^{\circ},\;24^{\circ}$). The 3-D kinematics was analysed by a camera-based falcon system. Groups difference was tested with one -way ANOVA and SNK test. The different kinematic patterns of ramp ascent were analysed and compared to level walking patterns. The kinematics of ramp walking could be clearly distinguished from the kinematics of level walking. In sagittal plane, Ankle joint was more dorsiflexed at initial contact and Max. dorsiflex. during stance phase with $16^{\circ},\;24^{\circ}$ inclination and more plantarflexed at toe off and Max. plantarflex. during swing phase with $24^{\circ}$(p<.001). Knee joint was more flexed at initial contact with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Hip joint was more flexed at initial contact and Max. flex. during swing phase with $16^{\circ},\;24^{\circ}$ inclination and at toe off with $24^{\circ}$(p<.001) and was more extended at Max. ext. during stance phase with $24^{\circ}$(p<.05). In frontal plane, ankle joint was more everted at Max. eversion. during stance phase with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Knee joint was more increased at Max. varus. during stance phase with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Hip joint was not differentiated with different inclinations. In horizontal plane, all joints were not differentiated with different inclinations. Conclusionally, In ascent ramp walking, the different gait pattern generally occurred at over $16^{\circ}$ on the ascending ramp in sagittal and frontal plane. These results suggest that there is a certain inclination angle or angular range where subjects do switch between a level walking and a ascent ramp walking gait pattern. This shows their motor control strategy between level and ascent ramp walking. Further studies are necessary to confirm and detect the ascent ramp gait patterns.

  • PDF

Modeling of Hanlim's gas turbine generator & qualitative analysis of PSS operation (한림가스터빈 발전기/제어계의 모델링 및 PSS 동작의 정성적 분석)

  • Choi, K.S.;Moon, Y.H.;Kim, D.J.;Choo, J.B.;Lyu, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.95-98
    • /
    • 1996
  • Response speed of generator/control system kas increased with the aid of the development of power electronics. Even though it is desirable to enhance response speed for the control system(AVR/Gov) of generator itself, in case a certain generator/control system with high response excitation system is connected with bulk power system, terminal voltage and active power of some generators can oscillate with adjoining generators or near area when even a little of disturbance take place. PSS(Power System Stabilizer) is used to damp rotor swing by adding the supplementary signal in phase with speed. As the stable AVR response is very important before PSS is installed, modeling and analysis of generator/control system was performed. Next we have analysed PSS response of Hanlim's gas turbine by transmission line open/close test.

  • PDF

Changes in Gait Parameter with Adolescent Idiopatic Scoliosis

  • Kim, Su-Hyon;Kim, Hyun-Jin
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.3
    • /
    • pp.136-139
    • /
    • 2014
  • Purpose: The purpose of this study will demonstrate that relationship between scoliosis and gait factor and foot weight bearing in ambulation. Methods: Subjects were 40 elementary students. A normal control group consisted of a total of 20 children without any known musculoskeletal disorders and an AIS group of 20 children with mild AIS (defined by a Cobb angle between 10 and $25^{\circ}$) were recruited. Measurements were scoliometer screening test, Cobb angle, gait parameter (rate of swing/stance phase, gait velosity), foot weight bearing (entire, fore, hind). Results: Scoliometer screening test (P = 0.000) and X-ray Cobb angle (P = 0.000) significant difference of group which was significantly higher in the AIS group. Gait parameter not showed significant difference. Forefoot weight bearing was significantly higher in the AIS group than more normal group. Conclusion: It seems that the results of weight bearing analysis in ambulation may be used in modifying rehabilitation programs for individual needs of patients with idiopathic scoliosis.

Rigorous Dynamic Simulation of PTSA Process (PTSA 공정의 상세 동적 모사)

  • Lee, Hye-Jin;Ko, Dae-Ho;Moon, Il;Choi, Dae-Ki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.309-309
    • /
    • 2000
  • The main objective of this study is to understand the regeneration step of the PTSA(Pressure and thermal swing adsorption) process below the atmospheric pressure by rigorous dynamic simulation. This target process is to recover toluene using activated carbon as an adsorbent. To do this, the dynamic simulations for the regeneration step are performed at 360, 490, 590mmHg and at high temperature after the simulation of the adsorption step at latm and 298K. A mathematical model was developed to simulate the column dynamics of the adsorption systems. This model is based on non-equilibrium, non-isothermal and non-adiabatic conditions, and axial dispersion and heat conduction are also considered. Heat transfer resistances are considered in gas-solid, gas-column wall and column wall-outside air. The LDF(Linear Driving Force) approximation model describes the mass transfer rate between the gas and solid phase. This study shows that the recovery of toluene by PTSA is more preferable than that by general TSA.

  • PDF

The Influence of Unstable Modified Wall Squat Exercises on the Gait Variables of Healthy Adults (정상 성인에서 불안정 지지면의 수정된 월-스쿼트 운동이 보행변수에 미치는 영향)

  • Gong, Won-tae;Lee, Jae-nam;Park, Jae-myoung
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • Background: This study was conducted to investigate the effects of unstable modified wall squat exercises accompanied by abdominal drawing-in on the gait variables of healthy adults. Methods: The total number of subjects was 30, and 15 were randomly placed in the training group (TG) and 15 in the control group (CG). To determine the gait variables of TG and CG, step length difference (SLD) stance phase difference (STPD), swing phase difference (SWPD), single support difference (SSD), and step time difference (STD) were measured using OptoGait, a gait analysis system. Results: When the pre-intervention and post-intervention results of TG and CG were compared, statistically significant differences in SLD, STPD, SWPD, SSD and STD of TG were seen. Conclusion: Unstable modified wall squat exercises accompanied by abdominal drawing-in might help reduce the deviation between left and right gait variables during walking.

  • PDF

Spatial and Temporal Features of Motor Modules in an individual with Hemiparesis During the Curvilinear Gait: A Pilot Single-Case Study

  • LEE, Jae-Hyuk
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • Purpose: This study aimed to investigate spatial and temporal features of motor control in an individual with hemiparesis during the curvilinear gait (CG) and proposed an exercise guideline. Research design, data and methodology: An individual aged 63 with hemiparesis by stroke disease was participated in the study. Autoencoder (AE) was used to extract four motor modules from eight muscle activities of the paretic leg during CG. After extraction, each module of four modules was operationally defined by numbering from M1 to M4 according to spatial and temporal features and compared with results reported in a previous study. Results: As a result, an individual with hemiparesis had motor module problems related to difficulty of weight acceptance (module 1), compensation for the weakness of ankle plantar flexor (module 2), a spastic synergistic pattern (module 3) and difficulty with transition from the swing to stance phase (module 4) in terms of spatial features. Also, a delayed activation timing of temporal motor module (module 2) related to the forward propulsion during CG was observed. Conclusions: Gait rehabilitation for the stroke will need to consider clinical significances in respect of the deterioration of motor module and provide the tailored approaches for each gait phase.

Muscle Eccentric Control in Gait Initiation (보행 시작 시 원심성 근육 수축 조절)

  • Kim, Hyeong-Dong
    • Physical Therapy Korea
    • /
    • v.8 no.4
    • /
    • pp.81-89
    • /
    • 2001
  • There are two independent mechanisms to control the segmental reflex gain in humans during gait. They are presynaptic inhibition and homosynaptic depression. Through the mechanism of the presynaptic inhibition, the muscle spindle afferent feedback can be properly gated during eccentric phase of gait. The modulation of the presynaptic inhibition is reflected in the level of H-reflex at a constant EMG level. During the eccentric muscle activation presynaptic inhibition should increase to account for the lower amplitude level of H-reflex at a constant level of EMG. Homosynaptic depression is another mechanism responsible for regulating the effectiveness of the muscle spindle afferent feedback. Both the presynaptic inhibition and the monosynaptic depression are responsible for modulating reflex gain during gait initiation. Reflex modulation is influenced not only as a passive consequence of the alpha motor neuron excitation level, but also through supraspinal mechanisms. Spastic paretic patients show the impaired soleus H-reflex modulation either during the initial stance phase, or during the swing phase. This abnormal modulatory mechanism can partially and artificially be restored by the application of peripheral stimulus to the sole of the foot, provided that the segmental circuitry remains functional.

  • PDF

Development of the Active Ankle Foot Orthosis to Induce the Normal Gait for the Paralysis Patients (마비 환자의 정상적 보행을 위한 능동형 단하지 보조기 개발)

  • Hwang, Sung-Jae;Kim, Jung-Yoon;Hwang, Seon-Hong;Park, Sun-Woo;Yi, Jin-Bock;Kim, Young-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.131-136
    • /
    • 2007
  • In this study, we developed an active ankle-foot orthosis(AAFO) which can control dorsi/ plantar flexion of the ankle joint to prevent foot drop and toe drag during walking. 3D gait analyses were performed on five healthy subjects under three different gait conditions: the normal gait without AFO, the SAFO gait with the conventional plastic AFO, and the AAFO gait with the developed AFO. As a result, the developed AAFO preeminently induced the normal gait compared to the SAFO. Additionally, AAFO prevented foot drop by proper plantarflexion during loading response and provided enough plantarflexion moment as a driving force to walk forward by sufficient push-off during pre-swing. AAFO also could prevent toe drag by proper dorsiflexion during swing phase. These results indicate that the developed AAFO may have more clinical benefits to treat foot drop and toe drag, compared to conventional AFOs, and also may be useful in patients with other orthotic devices.

The design of high efficiency DC-DC Converter with ESD protection device for Mobile application (모바일 기기를 위한 ESD 보호 소자 내장형 고효율 DC-DC 컨버터 설계)

  • Ha, Ka-San;Son, Jung-Man;Shin, Samuell;Won, Jong-Il;Kwak, Jae-Chang;Koo, Yong-Seo
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.565-566
    • /
    • 2008
  • The high efficiency power management IC(PMIC) for Moblie application is proposed in this paper. PMIC is controlled with PWM control method in order to have high power efficiency at high current level. The saw-tooth generator is made to have 1.2 MHz oscillation frequency and full range of output swing from ground to supply voltage(VDD:3.3V). The comparator is designed with two stage OP amplifier. And the error amplifier has 70dB DC gain and $64^{\circ}$ phase margin. DC-DC converter, based on Voltage-mode PWM control circuits, achieved the high efficiency near 95% at 100mA output current. DC-DC converter is designed with LDO in stand-by mode which fewer than 1mA for high efficiency.

  • PDF