• Title/Summary/Keyword: Suture Anchor

Search Result 114, Processing Time 0.019 seconds

Subscapularis Tendon Rupture with Medial Dislocation of Biceps Tendon - Case Report - (견갑하근 건 파열과 동반된 상완 이두근 건 탈구)

  • Lee Byung-Ill;Kim Dong-Wook;Kim Dong-Jin;Min Kyung-Dae;Rah Soo-Kyoon
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.147-153
    • /
    • 1998
  • Biceps tendon dislocation combined with rupture of subscapularis tendon is not a common lesion and there has been few case reported in Korea. We experienced one fifty Six years old male patient who shows typical features on physical examination and roentgenographic finding. He was injured by direct trauma on his right shoulder in adducted and external rotated position. He showed positive findings on passive external rotation test and lift-off test. On MR!, the subscpaularis tendon was totally ruptured and the biceps tendon was dislocated to anteromedial aspect of the glenoid labrum, which was typical finding. On the arthroscopic examination, the subscapularis tendon was totally ruptured from its humeral attachment and the biceps tendon was not seen in its normal anatomical position and it was dislocated antermedially to the glenoid labrum. We repaired the subscapularis tendon to humerus by use of suture anchor and the biceps tendon was relocated to its normal anatomical position in the intertubercular groove. On the post operative 6 months follow up, the patient shows improvements in his subjective symptoms and active range of motion.

  • PDF

Calcaneal Tuberosity Avulsion Fracture after Repair of Achilles Tendon Rupture: A Case Report (아킬레스건 파열 이후에 발생한 종골 결절의 견열골절: 증례 보고)

  • Lee, Sung Hyun;Yi, Young;Kim, Saintpee;Kang, Hong Je
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.216-219
    • /
    • 2019
  • In clinical practice, recurrent Achilles ruptures have been noted to occurr at the original ruptured site. However, reports of new developed fresh rupture of the Achilles tendon in other sites are is extremely rare. Our report is about one uncommon case of a traumatic calcaneal tuberosity avulsion fracture following augmented repair, which was performed using the Krackow locking loop technique. We performed open reduction and intra-osseous fixation using a suture anchor. This procedure was done through the primary longitudinal incision for the calcaneal avulsion fracture fragment. After 6 months of follow-up, our patient has achieved a complete functional recovery and he can normally perform daily and work-related tasks without pain.

Stabilization of Recurrent Medial Shoulder Luxation by Use of Three Bone Anchors in a Dog (재발성 내측 어깨 탈구를 보이는 개에서 본 앵커를 이용한 외과적 치료 증례)

  • Yoon, Hun-Young;Roh, Mi-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.30 no.1
    • /
    • pp.45-48
    • /
    • 2013
  • A 12-year-old male poodle weighing 2.0 kg presented for evaluation of right thoracic limb lameness. The owner reported that the dog showed recurrent bilateral shoulder joint luxation after a car accident for a year. Recently, the left shoulder joint appeared well maintained, but right shoulder joint luxation was exacerbated. On physical examination, the dog showed non-weight bearing lameness on the right thoracic limb. Craniocaudal radiographic views revealed medial displacement of the right humerus. Mediolateral radiographic views revealed overlap of the glenoid cavity and humeral head. Muscle atrophy of the right thoracic limb, reduced biceps brachii muscle tendon tone, a tear of the medial glenohumeral ligament, and a rupture of the subscapularis tendon were identified intraoperatively. Transposition of the biceps muscle tendon was performed. However, at 7 days, there was evidence of right shoulder reluxation on radiographs. The second surgery was performed with two $2mm{\times}6mm$ cortical bone anchors and a $4mm{\times}6mm$ cancellous bone anchor placed in the cortical bone of the distal scapula and the cancellous bone of the proximal humerus respectively. Two scapular bone anchors were then connected with a humeral bone anchor using heavy nylon suture to minimize shoulder abduction range of motion. On radiographs right after surgery and 6 weeks after surgery, the affected limb revealed no evidence of medial shoulder luxation. At 6 months, no evidence of lameness was noted on the right thoracic limb.

Patterns of Retear After Repair of the Rotator Cuff - MRI Analysis of 109Cases - (회전근 개 봉합술 후 발생한 재파열의 양상 - 109예의 자기 공명 영상 검사 분석 -)

  • Tae, Suk-Kee;Kim, Young-Sung;Lee, Ho-Min;Park, Pan-Kun
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.16-24
    • /
    • 2012
  • Purpose: This study was designed to investigate the rate of incidence, location and the clinical value of the rotator cuff retear by analyzing MRI scans, which was taken after an arthroscopic rotator cuff repair. Materials and Methods: This study included a total of 109 patients, who underwent a shoulder MRI scan after an average of 10.6 months later from the arthroscopic rotator cuff repair. We only defined the 'retear' when the Sugaya type IV and V was observed in the sagittal section of the MRI. The location of the retear was divided into the medial and lateral areas by the site, which was 1 cm medial to the anchor insertion. We investigated the incidence rate and the location of the retear, in terms of the age, sex, initial tear size and the suture method. Also, we compared the functional score of the retear group and the non-retear group, after an average of 13.9 months follow-up. Results: There were 38 of the 109 patients that showed the rotator cuff retear. Of these patients, 25 were male patients, and 13 were female patients. Of the 38 patients with the rotator cuff retear, 21 patients were included in the <3 cm retear group, and 17 were included in the ${\geqq}3$ cm retear group. At the end of the follow up period, all 109 patients showed a statistical significant improvement in the shoulder functional score. Conclusion: According to the follow up of the MRI scan, which was taken after the rotator cuff repair, the retear rate reached 34.9 %, and there were no significant differences on the age and the suture method. More rotator cuff retear occurred in male patients, and the initial tear size was positively correlated with the incidence rate of the rotator cuff retear. Also, the retear was more frequently observed at the medial side. That is because when the suture was performed, excessive tension was loaded on the medial side of the suture site.

New V-shaped Technique in SLAP Repair (Comparison of Cinical Results Between New V-shaped Repair and Conventional Rapair Technique in Arthroscopic Type II SLAP Surgery) (SLAP 병변 수술에 사용 가능한 새로운 V자 봉합 (Type II SLAP 병변의 관절경적 수술에 있어 새로운 V자 형태의 봉합술기와 기존의 방법과의 임상결과 비교))

  • Hyun, Yoon-Suk;Shin, Sung-Il;Kang, Jung-Woo;Ahn, Joo-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • Purpose: The purpose of this study was to compare clinical outcomes between the new V-shaped repair method and conventional methods for the arthroscopic repair of Type II SLAP lesions. Materials and Methods: Our study population consisted of 23 people treated with the new V-shaped repair method or conventional methods in the arthroscopic repair of Type II SLAP lesions at our institution between May 2006 and October 2008. Eleven shoulders were treated using the new V-shaped repair method. Twelve shoulders were treated using conventional methods. The average follow up period was 15 months. For evaluation of clinical results, we used UCLA and VAS pain scores. Results: Comparing change scores (preoperative vs. postoperative states) there were no significant differences in UCLA score or VAS score between the two groups. Conclusion: The new V-shaped repair technique elicits similar clinical results with conventional arthroscopic repair techniques and thus can be considered a useful alternative when using an absorbable suture that is anchor linked with only one suture.

Posterior type II SLAP Lesion Combined with Posterior Bankart Lesion - A Case Report - (후방 Bankart 병변을 동반한 후방 II형 SLAP 병변 - 증례보고 -)

  • Cheon, Sang-Jin;Youn, Myung-Soo;Kim, Hui-Taek;Suh, Jeung-Tak
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.2
    • /
    • pp.134-138
    • /
    • 2008
  • SLAP(Superior labrum anterior to posterior) lesion is found in superior labrum injury alone and also combined with extension of the Bankart lesion(anteroinferior labral tear) in recurrent shoulder dislocation patients and rarely accompanied by the posterior Bankart lesion. There have been reports about SLAP lesions associated with various lesions, however, posterior type II SLAP lesion associated with posterior Bankart lesion has been rarely reported. In such a case, there are important technical tips in inserting anchors and suturing during arthroscopic repair. We experienced a rare case of posterior type II SLAP lesion associated with posterior Bankart lesion, occurred not after repetitive throwing(common mechanism) but after trauma in slipping down with the arm stretched during riding a bicycle. The satisfactory result was obtained after arthroscopic repair in this case.

  • PDF

Calcific Tendinitis of Shoulder Associated with Intraosseous Involvement -A Case Report- (골내 침범을 동반한 견관절 석회화 건염 - 증례 보고 -)

  • Ku, Jung-Hoei;Cho, Hyung-Lae;Park, Man-Jun;Kim, Jeong-Cheol
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.2
    • /
    • pp.242-247
    • /
    • 2011
  • Purpose: We present an atypical case of calcific tendinitis of the shoulder with intraosseous loculation. Materials and Methods: A 59 year-old female complained of acute exacerbation of chronic left shoulder pain and restricted range of motion. Simple radiographs showed a subacromial calcific deposit and magnetic resonance imaging revealed cortical erosion with intraosseous extension of calcific material mimicking infection or tumor. She was managed with arthroscopic excision of the calcific deposit, curettage of the intraosseous lesion and subsequent rotator cuff repair with a suture anchor. Results: Her acute pain promptly subsided. Her rehabilitation was uneventful and she gained full range of motion. Radiographs five months after the operation showed no recurrence of calcific material. Conclusion: Calcific tendinitis of the shoulder can present with a variety of images involving the adjacent bone. The correct recognition of this disorder may avoid unnecessary investigation and treatment.

Arthroscopic Anterior Talofibular Ligament Repair for Grade II Chronic Ankle Instability - Two Cases Report - (족관절 중등도 불안정성의 관절경적 전거비인대 봉합 - 증례 보고 -)

  • Song, Baek-Yong;Young, Ki-Won;Kim, Jin-Su;Park, Young-UK;Kim, Tae-Won;Lee, Kyung-Tai
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.1
    • /
    • pp.22-27
    • /
    • 2011
  • The modified Brostrom procedure is first considered for the treatment of chronic ankle instability (CAI). Recently, ankle arthroscopy is also recommended for the treatment of concomitant intra-articular lesions during the open repair of the lateral ligaments. We arthroscopically repaired the anterior talofibular ligament with a use of bio suture anchor for CAI as well as performing the multiple drilling procedure for combined osteochondral lesion of talus. We report the cases with a review of the literature.

  • PDF

Cranioplasty and temporal hollowing correction with a three-dimensional printed bioresorbable mesh and double vertical suture anchor muscle sling: a case report

  • Choi, Jae Hyeok;Roh, Tai Suk;Lee, Won Jai;Baek, Wooyeol
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.4
    • /
    • pp.178-182
    • /
    • 2022
  • Postoperative temporal hollowing is a common complication of craniotomy. Damage and repositioning of the temporalis muscle can lead to a depression in the temporal side of the skull with inferior bulging, worsening aesthetic outcomes. We report a case of cranioplasty with three-dimensional (3D) printed mesh involving an additional correction using a temporalis muscle sling to help address this problem. A 3D-printed bioabsorbable mesh was prepared based on preoperative facial computed tomography, and was fixed to the hollowed area for tissue augmentation. The temporalis muscle was elevated and fanned out to its original position, and a sling was attached to a screw that was fixed to the mesh. For reinforcement, an additional sling was attached to another screw fixed to the mesh 2-3 cm vertically above the first screw. Aesthetic results were confirmed immediately after surgery and later during outpatient follow-up. Both depression and lateral bulging were resolved, and there was no delayed drooping of the temporalis muscle on 6-month follow-up. There were no complications, and the patient was satisfied with the appearance. This is a simple yet effective technique with a low risk of complications, and should be considered for postoperative temporal hollowing patients, especially those with severe lateral bulging.

Anatomical Analysis of Superior Glenoid and Glenoid Labrum (상부 관절와 및 관절와 순의 해부학적 분석)

  • Choi, Nam-Yong;Song, Hyun-Seok;Yoon, Hyung-Moon;Choi, Seung-Gyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.102-106
    • /
    • 2010
  • Purpose: The results of the repair for the superior labrum lesions attaching at the superior glenoid have not been satisfactory in every cases. We wanted to analyze the shoulder MRI and the anatomical morphology and pattern of the superior glenoid at which the superior labrum attaches to get anatomical information helpful in treating the superior labrum. Materials and Methods: We analyzed the coronal images of the shoulder MRI of 108 cases taken at our hospital. Average age was 52 years (range, 17~71 years), 55 males and 53 females. On two coronal images behind the attachment of the long head of biceps that the repair of the SLAP was performed at, the length of the attachment of superior labrum and the angle of the supero-lateral glenoid were measured. Results: The average length of the attachment of superior labrum was $9.78{\pm}1.64\;mm$. The average length was $10.1{\pm}1.61mm$ in male, $9.43{\pm}1.6\;mm$ in female. The angle of the supero-lateral glenoid was $89.6{\pm}7.6$ degrees. Conclusion: The attachment of the superior labrum in coronal plane was shorter in posterior spot than anterior. The angle of the supero-lateral glenoid was less in posterior spot.

  • PDF