• Title/Summary/Keyword: Sustained load

Search Result 112, Processing Time 0.031 seconds

Conceptual design of prestressed slab bridges through one-way flexural load balancing

  • Arici, Marcello;Granata, Michele Fabio
    • Structural Engineering and Mechanics
    • /
    • v.48 no.5
    • /
    • pp.615-642
    • /
    • 2013
  • In this paper a study on prestressed concrete slab bridges is presented. A design philosophy based on the concept of load balancing through prestressing is proposed in order to minimize the effects of delayed deformations due to creep. Aspects related to the stress redistribution inside these bridges for time-dependent phenomena are analyzed and discussed, by applying the principles of aging linear visco-elasticity. Prestressing is seen as an equivalent external load which counterbalances the permanent loads applied to the bridge, nullifying the elastic deflections due to sustained loads, and thus avoiding the related delayed deformations. An optimization of the structural behavior through the use of one-way prestressing is achieved. The determination of a convenient variable depth of slab bridges and the correspondent layout of tendons is considered as a useful means for applying the load balancing concept in actual cases of structures like long cantilevers or bridge decks. A case-study related to the slab bridges built 30 years ago at Jeddah in Saudi Arabia is presented and discussed, in order to show the effectiveness of the proposed approach to the conceptual design of prestressed concrete bridges.

Characteristics of Smart Skin for Wireless LAN system under Buckling Load (무선 랜 시스템용 스마트 스킨의 좌굴 특성 연구)

  • 전지훈;유치상;황운봉;박현철;박위상
    • Composites Research
    • /
    • v.14 no.2
    • /
    • pp.43-49
    • /
    • 2001
  • The characteristics of smart skin for wireless LAN system under compression load are investigated. The smart skin structure is composed of 3 layers of face material and 2 layers of core material. Theoretical formula for determining buckling load is derived by Rayleigh-Ritz method and compared with experimental result. The maximum length of specimen that buckling does not occur is determined by assuming that the compression load is sustained by only face material. In the experiment, if buckling occurs obviously then it follows the theoretical result well. In the process of buckling, the load supporting capability and the antenna property such as radiation pattern and reflection coefficient were examined.

  • PDF

Unified Reliability and Its Cost Evaluation in Power Distribution Systems Considering the Voltage Magnitude Quality and Demand Varying Load Model (전압 크기의 품질 및 전력수요 변동모델을 고려한 배전계통의 통합적인 신뢰도 및 비용 평가)

  • Yun, Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.705-712
    • /
    • 2003
  • In this paper, we propose new unified methodologies of reliability and its cost evaluation in power distribution systems. The unified method means that the proposed reliability approaches consider both conventional evaluation factor, i.e. sustained interruptions and additional ones, i.e. momentary interruptions and voltage sags. Because the three voltage quality phenomena generally originate from the outages on distribution systems, the basic and additional reliability indices are summarized considering the fault clearing mechanism. The proposed unified method is divided into the reliability evaluation for calculating the reliability indices and reliability cost evaluation for assessing the damage of customer. The analytic and probabilistic methodologies are presented for each unified reliability and its cost evaluation. The time sequential Monte Carlo technique is used for the probabilistic method. The proposed DVL(Demand Varying Load) model is added to the reliability cost evaluation substituting the average load model. The proposed methods are tested using the modified RBTS(Roy Billinton Test System) form and historical reliability data of KEPCO(Korea Electric Power Corporation) system. The daily load profile of the each customer type in domestic are gathered for the DVL model. Through the case studies, it is verified that the proposed methods can be effectively applied to the distribution systems for more detail reliability assessment than conventional approaches.

An effects of the Pulse Distortion due to Dispersion and Reflection on Tapered Microstrip Line (데이퍼형 마이크로 스트립 선로에서 분산과 반사가 펄스의 왜곡에 미치는 영향)

  • 김기래
    • Proceedings of the IEEK Conference
    • /
    • 2000.06a
    • /
    • pp.271-274
    • /
    • 2000
  • In this paper, the distortion of an electrical pulse with rise/fall time resulting from dispersion and reflection as it propagates along a tapered microstrip line is investigated, and the delay time and distortion rate with respect to input and load impedances are analyzed on triangular and exponential tapered lines and analyzed the influence of the reflection and frequency dispersion on the distorted voltage wave in the tapered lines. The observed overshoot in front of the distorted wave is caused due to the frequency dispersion and the sustained tail of that comes from the reflection in the tapered line.

  • PDF

Fracture and dislocation of the four lateral metatarsophalangeal joints - A case report (외측 4개 중족 족지 관절의 골절-탈구 - 증례보고 -)

  • Yim, Soo-Jae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.4 no.1
    • /
    • pp.19-22
    • /
    • 2000
  • Fracture and dislocation of the four lateral metatarsal head and neck at the metatarsophalangeal joint, which may be associated with a hyperextension force, axial load, and additional rotating force, has rarely been reported. The patient was a 32-year-old man who sustained the injury in a motor vehicle accident. Manual reduction was easily performed but maintenance of reduction was difficult, due to the associated fractures of the metatarsal necks. Thus percutaneous internal fixation with Kirshner's wires was required.

  • PDF

Experimental Investigation on the Creep Behavior of Pultruded FRP Composite Columns (인발성형 FRP 복합소재 기둥부재의 크리프거동에 대한 실험적 분석)

  • Kang, Jin Ook;Abdul Hamid Zureick
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.299-306
    • /
    • 2003
  • This paper presents the results of an experimental investigation pertaining to the creep behavior of fiber-reinforced polymeric (FRP) pultruded components subjected to sustained eccentric axial loading. Six different axial load/eccentricity combinations were investigated through the experiments. The test duration of these experiments was 2,000 hours (90 days), during which the mid-height lateral deflections of the components were recorded continually. Analytical formulations based on the Schapery's quasielastic method and a power law model were used for the prediction of the creep lateral deflection.

  • PDF

The Estimation of Stress Variationdue to Creep and Shrinkage on Composite Girder Section (크리프 및 건조수축에 의한 합성거더 단면의 응력변화 추정)

  • Kim, Byung-Kyu;Kim, Su-Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.357-360
    • /
    • 2006
  • Under sustained load, the stress variation occurs due to creep and shrinkage of concrete on the sections of steel-concrete composite girders. In standard specification for highway bridge, the method of stress estimation considering time effects is based on the concept of Yassumi method. In this study, comparing the analysis results using the AEMM and Yassumii method long-term behaviors, the rationality of specified requirements is checked.

  • PDF

Tapping the Potential of Roof Greening and Building a New City-scape

  • Wang, Xiao-yun
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.1
    • /
    • pp.33-36
    • /
    • 2001
  • Only do we have an earth! It is crucially important to improve our living environment and keep the sustained development of a city in the limited space. Some concrete examples will be analysized in the paper, elaborating upon how to make full use of roof space and various plants to create a better green-space. To create different activity space with unique characteristics for people, various plants, roof-space, water and buildings in the style of garden should be use when local conditions and design requirement should be considered.

  • PDF

탄소섬유 복합재료 사각튜브의 압추에너지 흡수 특성

  • Han, Chang-Whan;Kim, Keun-Taek;Lee, Jong-Won;Choi, Youn-Ho
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.19-31
    • /
    • 2002
  • Crush energy characteristics of graphite/epoxy square tubes are experimentally studied. Effect of the ply orientation on the peak load and the average load is investigated by applying compressive load on the top of the composite square tubes under the stroke control with crosshead speed of 0.003mm/sec and 0.3mm/sec. in addition to the experimental survey, the finite element analysis is used to estimate the peak load of the composite square tubes with [0/90]₄ and [0/±45/90]₂. The first buckling mode of the tube is superimposed to the perfect geometry and the distributed compressive load is applied on the top of the tubes. The applied compressive load that make Tsai-Wu criteria equal to one is regarded as the peak load of the tubes. The experimental data shows that the square tube with [45/-45]₄ has the highest peak load and the square tube with [60/-60]₄ has the average sustained load. The measure peak load of the composite tubes with [0/90]₄ and [0/±45/90]₂agree well with the estimated peak load using the finite element analysis.

  • PDF

Development of an Improved Point Load Apparatus (개량형 점하중강도시험기의 개발)

  • Kim, Yong-Phil;Um, Jeong-Gi
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.473-478
    • /
    • 2009
  • The accuracy of point load apparatus is depend on point to point coaxial fitting. Also, the estimation of applied point load using the pressure gauge frequently lead to erroneous results. An improved point load apparatus has been developed in this study by mounting linear bearing on polished support rod, and eccentric error of point to point axis has been sustained less than 0.1 mm even under series of extreme work load conditions. Two digital displacement gauges are attached to measure the distance from point to point with sample specimen. A load cell mounted at the end of upper conical platen measure the applied net load on sample instead of preassure gauge. Total of 107 point load tests has been achieved to assure the quality and performance of developed apparatus. This exercise turned out to be successful.