• Title/Summary/Keyword: Suspended solid

Search Result 436, Processing Time 0.026 seconds

Effects of Energy Input and Air Flow Rate on Oxygen Transfer Rate at Different MLVSS in a Jet Loop Reactor (JLR) (MLVSS에 따른 Jet Loop Reactor (JLR)에서 동력량과 공기량이 산소전달률에 미치는 영향)

  • Yoon, Ae-Hwa;Bae, Jong-Hun;Lim, Hyun-Woo;Jun, Hang-Bae;Huh, Tae-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.868-873
    • /
    • 2011
  • Oxygen transfer rate generally determines the performance of an aerobic wastewater treatment process that treats high strength wastewater such as food wastewater, animal wastewater and landfill leachate. In this paper, OUR and $K_L{\cdot}a$ were evaluated by using Jet Loop Reactor (JLR) according to the concentration of a mixed liquor volatile suspended solid (MLVSS), oxygen (air) flow rate and energy input as the variable of the operating conditions. Also, a nonlinear regression model was proposed by the statistical methods with the calculated $K_L{\cdot}a$. As a results, in case of applying the high strength wastewater which has to maintain high MLVSS, the energy input and the air flow rate are major parameters oxygen transfer rate in JLR. Finally, the final nonlinear regression model had been developed as a function of E/V, $Q_g$, and ${\mu}_c$.

The Evaluation of the Water Quality in Coastal Boundary on Tidal flat (통계분석기법을 이용한 전남 갯벌 해역 수질특성)

  • Jun, Sue-Kyung;Kim, Chong-Ki;Kim, Yun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • To understand characteristics of the water quality on the coastal boundary on tidal flat, field observations between 2008 and 2009 were undertaken twice a month at five coastal areas (Muan bay, Tando bay, Hampyeong bay, Shinan Jido and Yeongkwang coastal areas). Yearly water temperature difference was large with the range between $1.3^{\circ}C$ and $31.1^{\circ}C$. Salinity was about 32 but was the lower less than 20 for the heavy rainfall season. DO was high in winter and low in summer according to the variation of water temperature. pH represented the variation similar to DO. Suspended solid was averagely high over 100 mg/l in Yeongkwang coastal area, especially. COD did not revealed large variation with the value of about 1 mg/l. DIN and DIP concentration were high when freshwater was highly input in summer. DIN concentration was low for winter and early spring but DIP concentration did not show the seasonal variation with the continuous increase from July 2009 to December 2009. Chlorophyll a appeared high for spring with approximately $10\;{\mu}g/l$ and was higher for summer in Yeongkwang coastal area than other sites. The results of principal component analysis conducted to compare the characteristics of water quality observed in study areas showed the distinguishable features as follows. The freshwater input fluctuation appeared as the first factor in Muan and Tando bays, and the change of water temperature was the first factor in Shinan Jido and Yeongkwang coastal areas. The influence mixed with the variation of freshwater outflow and the change of water temperature in Hampyeong bay was to be the first factor.

Dechlorination of Atrazine in Sediment Using Zero Valent Iron (영가철($Fe^0$)을 이용한 퇴적물내 Atrazine의 탈염소화)

  • Kim, Geon-Ha;Jeong, Woo-Hyeok;Choe, Seung-Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.4
    • /
    • pp.33-40
    • /
    • 2006
  • Residual pesticides discharged from diffuse sources at agricultural area in association with suspended solid will be settled at downstream, and may degrade surface water quality. This research studied dechlorination kinetic of atrazine, one of triazine-category herbicide, using zero-valent iron (ZVI) in sediment. It can be observed from the experiments that buffer capacity of sediment helped pH maintained beutral, resulted in continuous dechlorination. Sediments were spiked with atrazine at 10, 30, and 50 mg atrazine/L of total sediment for batch experiments. Dechlorination constants were $1.38x10^{-1}/d$ for the initial concentration of 10 mg/L, $1.29x10^{-l}/d$ for 30 mg/L, and $7.43x10^{-2}/d$ for 50 mg/L while dechlorination constants of initial concentration of 50 mg/L without ZVI adding were estimated as $3.05x10^{-2}/d. Half lifes atrazine by ZVI were estimated as 5.03 d fur 10 mg/L, 5.38 d for 30 mg/L, and 9.33 d for 50 mg/L, respectively.

The Estimation of Water Quality Changes in the Keum River Estuary by the Dyke Gate Operation Using Long-Term Data (장기관측자료에 의한 금강하구둑 수문조작에 따른 수질 변화 평가)

  • KWON Jung-No;KIM Jong-Gu;KO Tae-Seung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.4
    • /
    • pp.348-354
    • /
    • 2001
  • This study was conducted to estimation of change characteristics for water quality by the dyke gate operation in the Keum River estuary. The estimation data made use of surveyed data in Keum River estuary by NERDI (National Fisheries Research and Development Institute) during $1990\~1999$. Shown to compare water quality changes at st. A and st. D in Figure 1, the concentrations of TSS, COD and nutrients at st. A were as high as about $2\~4$ times than those at st. D due to affection of fresh water discharge in the Keum River. The percentages of water quality change at surface water by dyke gate operation in the Keum River estuary were shown that TSS (Total Suspended Solid) was decrease to $56\%,\;47\%$ at st. A and D, and COD (Chemical Oxygen Demand) was increase to $68\%,\;71\%$ at st. A and D, respectively. The changes percentage of DIN (Dissolved Inorganic Nitrogen) by dyke gate operation in the Keum River estuary were increase high to $95\%$ at surface water and $7\sim30\%$ at bottom water, but those of DIP (Dissolved Inorganic Phosphorus) were increase to $2.8\sim8.6\%$ at surface water and $28\%$ at bottom water. The range of fluctuation for water quality at each station by dyke gate operation has shown that salinity and TSS are little better than before dyke gate operation, but COD show highly fluctuation. Also we studied estimation of characteristics of water quality change by the season, COD was increased except the summer, TSS was decreased to all season. DIN was increased to about $61\sim172.1\%$ for all season, but DIP was increased to the spring and decreased to the autumn, DIN enrichment in the estuary by dyke gate operation are interpreted to improvement of organic matter decomposition and nitrification by increasing the residence time and to increase nutrient flux in sediments due to decreasing dissolved oxygen and increasing a deposit matter.

  • PDF

Decontamination of simulated radioactive metal waste by modified electrolytic Process with neutral salt electrolytes (개선된 중성염 진해공정을 이용한 모의 방사성 금속폐기물의 제염)

  • Lee, Ji-Hoon;Yuk, Wan-Yi;Yang, Ho-Yeon;Ha, Jong-Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.2
    • /
    • pp.95-100
    • /
    • 2002
  • Conventional and modified electrolytic decontamination experiment were performed in the 1.7 M solution of sodium sulfate and sodium nitrate tot decontamination of carbon steel as the simulated metal wastes which have been produced in large amounts from nuclear power plants. Anode ant cathode were used as inconel and titanium respective. The reaction time and temperature were 1 hr and $25^{\circ}C$ The analyses were performed of the characteristics such as weight loss arid thickness change of metal waste. suspended solid in electrolyte and SEM observation. In modified electrolyte decontamination system with increased current density ranged from 0.1 to $0.6A/cm^2$, the metal waste showed thickness changes of $0.48{\pm}0.005$ to $67.7{\pm}0.02{\mu}m$ in 1.7 M sodium sulfate and those of $0.06{\pm}0.005$ to $17.7{\pm}0.05{\mu}m$ in sodium nitrate. Metal waste in modified electrolyte decontamination system showed the thickness change of $9.8{\pm}0.01{\mu}m$ while it reacted up to $3.7{\pm}0.03{\mu}m$ in conventional system with $0.3 A/cm^2$ of current density and 1.7 M sodium sulfate. Decontamination efficiencies of modified electrolytic process ate much hither than that of conventional electrolytic process when both are applied to metal waste.

Characteristics Evaluation of Non Point Source Treatment Facilities in Construction Site (건설 현장 내 비점오염원 처리 시설의 제거 특성 평가)

  • Choi, Younghoa;Jeong, Seolhwa;Kim, Changryong;Kim, Hyosang;Oh, Jihyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.53-62
    • /
    • 2009
  • This study was conducted to investigate characteristics of the non-point source pollution under construction and evaluate available pollution control methods. Suspended solid loading is high when soil disturbs by rainfall and this phenomenon is much more severe at the initial stage of construction than at the final one. There are three methods available for erosion and sediment control, which are check dam, silt fence, and geotextile. Check dam and silt fence are for control of suspense solids and geotextile is for preventing soil erosion during rainfall. They can be installed as temporary control facilities at construction sites. From the comparison of those methods, it was found that geotextile method was the most efficient for the runoff control of non-point source pollution. Check dam and silt fence can remove suspense solids by pore spaces to some degree, but the removal of pollutants mainly occurs through sedimentation. Because the temporary control facilities have limited removal efficiency of pollutant, they often cause civil claims and contamination of water environment. Hence, using a pressurized filtration system along with temporary control facilities, highly enhanced treatment efficiency was anticipated. In addition, the loading capacity of these techniques depends on filtration velocity and input loading. And their pre-treatments are necessary for efficient operation.

  • PDF

The Horse Manure Fertilizers and Pollutants Characteristics Analysis Research (말 분뇨의 비료성분 및 오염물질 특성 조사 연구)

  • Kwag, J.H.;Jeong, M.W.;Choi, D.Y.;Kim, J.H.;Kim, Y.H.;Park, J.C.;Kim, I.C.;Yang, C.B.;La, C.C.
    • Journal of Animal Environmental Science
    • /
    • v.18 no.3
    • /
    • pp.201-206
    • /
    • 2012
  • Horse manure general composition and contaminants, heavy metals content analysis was investigated as follows. The moisture content of horse feces was 76.1% and 96% for horse urine. The average T-N, T-P, T-K concentrations of the racing horse were 0.18%, 0.10%, 0.22% respectively and 2.88%, 0.0015%, 0.84% for urine. And the average BODs, COD, SS concentrations were 26,906 $mg/{\ell}$, 36,642 $mg/{\ell}$, 89,375 $mg/{\ell}$ respectively and 14,298 $mg/{\ell}$, 7,484 $mg/{\ell}$, 6,987 $mg/{\ell}$ for urine. In addition, the Cr, Cu, Ni, Cd, Pb, Zn concentrations of feces were 2.65 mg/kg, 7.05 mg/kg, 1.24 mg/kg, 0.07 mg/kg, 0.01 mg/kg, 45.11 mg/kg respectively and 1.52 mg/kg, 1.62 mg/kg, 0.00 mg/kg, 0.03 mg/kg, 0.03 mg/kg, 4.49 mg/kg for urine on the fresh matter basis. The end of the survey was that the quality of the compost can be used as a raw material, and manure is necessary to constantly driven forward horse manure composting research.

Temporal and Spatial Evaluation of Water Pollution Characteristics in Gohyeon Stream and Its Tributaries (고현천 및 유입지류의 수질오염 특성의 시·공간적 평가)

  • Kim, Sung-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.3
    • /
    • pp.235-247
    • /
    • 2012
  • BACKGROUND: Gohyeon Stream is the municipal eco-stream of 7.1km in total length which flows through the downtown area of Gohyeon in Geoje city, rising from the watershed of Mundong Water Fall. Gohyeon district in Geoje city has been a rapid growing area centering in Geoje city and then experienced an rapid increase in population. Large amounts of sewage pollutants have been spewed into Gohyeon Stream from its tributaries, due to the lack of sewer system. Gohyeon Stream is laced with unhealthy levels of fecal coliform (FC). Restoration of water quality in Gohyeon Stream is no less inevitable in behalf of its ecosystem and the citizen. In this study, the water quality of Gohyeon Stream and its tributaries was examined temporally and spatially, and their relationships were comparatively analyzed to give useful basic data applying to a restoration project of the water quality of Gohyeon Stream. METHODS AND RESULTS: The samples ware taken at 20 points in Gohyeon Stream and 19 points in its tributaries during the rainy and dry seasons, respectively, and examined on the parameters of pH, temperature, salinity, dissolved oxygen (DO), suspended solid (SS), biochemical oxygen demand (BOD), chemical oxygen demand (COD), dissolved inorganic nitrogen (DIN; $NH_3$-N, $NO_3$-N, $NO_2$-N), disolved inorganic phosphorus (DIP; $PO_4$-P) and FC. The data were analyzed using a comparative analysis and Pearson's correlation analysis among the parameters. During the rainy season, the concentration of SS was high in the upper region of Gohyeon Stream, and the concentrations of COD, DIN and DIP were low in the upper region and high in the middle and lower regions. During the dry season, the concentration of SS was low and the concentrations of COD, DIN, DIP and FC were high in all regions. The Pearson's correlation analyses showed that the relationships between DO and FC, COD and DIP, and DIN and FC during the rainy season as well as between DO and DIN, SS and FC, COD and DIP, and DIN and DIP during the dry season were significant. CONCLUSION: During the rainy season, the upper region of Gohyeon Stream flowed the high level of SS, the middle region the high level of nutrients due to an agricultural run-off, and the lower region the high level of nutrients due to a sewage inflow. During the dry season, the water quality of Gohyeon Stream was directly and sensitively influenced on the inflow of sewage from the tributaries.

Evaluation of Water Quality Characteristics at Kyeongan Stream Using the Flow-Loading Equation and Factor Analysis (유량-오염부하량 관계식과 요인분석을 이용한 경안천의 수질특성 평가)

  • Kwon, Phil-Sang;Park, Min-Ji;Lee, Young-Joon;Cho, Yong-Chul;Noh, Chang-Wan;Jung, Woo-Seok;Kim, Ji-Ho;Yu, Soon-Ju
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.4
    • /
    • pp.226-236
    • /
    • 2017
  • In this study, we aimed to analyze the characteristics of water quality variation at Kyeongan Stream for a decade and to investigate by the flow-loading equation. The correlation analysis of water quality parameters and the influence factors were examined by statistical analysis. The characteristics of water quality variation showed that the fluctuations in $BOD_5$, $COD_{Mn}$ and TOC were repeated from year to year. TN and TP were decreased by year. By the flow-loading equation, the concentrations of $BOD_5$, $COD_{Mn}$, TOC and TN were decreased when the flow rate was on the rise. However, the flow did not affect the concentration of TP. According to correlation analysis, $BOD_5$ was highly correlated with $COD_{Mn}$ and TOC with the correlation coefficients of 0.890 (p<0.01) and 0.721 (p<0.01). The result of factor analysis, we identified that the water quality in Kyeongan Stream has been highly influenced by the organic matter index, followed by nitrogenous substance depending on the seasonal variations and the influx of suspended solid in accordance with the increase of flow.

A Study on Electrodeionization for Purification of Primary Coolant of a Nuclear Power Plant (원자력 발전소의 일차 냉각수 정화를 위한 전기탈이온법의 기초연구)

  • Yeon, Kyeong-Ho;Moon, Seung-Hyeon;Jeong, Cheorl-Young;Seo, One-Sun;Chong, Sung-Tai
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.73-86
    • /
    • 1999
  • The ion-exchange method for the purification of primary coolant has been used broadly in PWR(pressurized water reactor)-type nuclear power plants due to its high decontamination efficiency, simple system, and easy operation. However, its non-selective removal of metal and non-radionuclides shortens its life, resulting in the generation of a large amount of waste ion-exchange resin. In this study, the feasibility of electrodeionization (EDI) was investigated for the purification of primary cooling water using synthetic solutions under various experimental conditions as an alternative method for the ion exchange. The results shows that as the feed flow-rate increased, the removal efficiency increased and the power consumption decreased. The removal rate was observed as a 1000 decontamination factor(DF) at a nearly constant level. For the synthetic solution of 3 ppm TDS (Total Dissolved Solid), the power consumption was 40.3 mWh/L at 2.0 L/min of feed flow rate. The higher removal rate of metal species and lower power consumption were obtained with greater resin volume per diluting compartment. However, the flow rate of the EDI process decreased with the elapsed time because of the hydrodynamic resistivity of resin itself and resin fouling by suspended solids. Thus, the ion-exchange resin was replaced by an ion-conducting spacer in order to overcome the drawback. The system equipped with the ion-conducting spacer resolved the problem of the decreasing flow rate but showed a lower efficiency in terms of the power consumption, the removal rate of metal species and current efficiency. In the repeated batch operation, it was found that the removal efficiency of metal species was stably maintained at DF 1000.

  • PDF