• Title/Summary/Keyword: Suspended Particle

Search Result 299, Processing Time 0.023 seconds

Polymeric Interactions of Dispersant and Binder in Aqueous Silicon Nitride Suspensions (질화규소 현탁액에서 분산제와 결합제의 상호작용연구)

  • Kim, Bong-Ho;Kim, Myong-Ho;Lee, Soo;Paik, Un-Gyu
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.8
    • /
    • pp.901-908
    • /
    • 1995
  • In aqueous slurry processing of silicon nitride, the interaction of dispersant and binder used as polymeric processing additives on the silicon nitride particle surface was studied to identify the effect of these processing polymeric additives on the ceramic powder processing. The adsoprtion isotherm study of anionic organic molecule as dispersant and nonionic organic molecules as binder of silicon nitricde was studied to investigate the effect of these processing organic additives on the physicochemical properties of silicon nitride particles. As anionic molecule adsorbed onto silicon nitrice surface, the IEP of silicon nitride shifted toward acidic pH and changed the stability of silicon nitride particle. However, the adsorption of binder as nonionic organic molecule onto silicon nitride surface did not changed the IEP but caused the decrease of electrostatic potentials of silicon nitride. These distinctive adsorption behaviors of organic additives on silicon nitride particles can be closely correlated to the stability of silicon nitride particles suspended in aqueous media.

  • PDF

Evaluation on Light Scattering Behavior of a Pulverized Coal Suspension (슬러리내 석탄입자의 광산란 특성 평가)

  • Hwang, Munkyeong;Nam, Hyunsoo;Kim, Kyubo;Song, Juhun
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.5
    • /
    • pp.451-460
    • /
    • 2013
  • In a direct coal fuel cell (DCFC) system, it is essential to identify volume fraction of coal suspended in electrolyte melt in order to control its dispersion and fluidity. This requirement is compelling especially at anode channel where hot slurry is likely to flow at low velocity. In this study, light scattering techniques were employed to measure the volume fraction for a pulverized coal suspension with relatively high absorption coefficient. The particle size, scattering angle, and volume fraction were varied to evaluate their effects on the scattering behavior as well as scattering regime. The larger coal size and smaller forward scattering angle could provide a shift to more favorable scattering regime, i.e., independent scattering, where interferences of light scattering from one particle with others are suppressed.

Analysis of Controlling the Size of Microbubble in DAF (DAF에서 기포의 크기제어 및 영향분석)

  • Dockko, Seok;Kwak, Dong-Heui;Kim, Young-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.235-241
    • /
    • 2004
  • The dissolved air flotation (DAF) process has been widely used for removing suspended solids with low density in water. It has been known as measuring the size of microbubbles precisely which move upward rapidly in contact zone is difficult. In this study particle counter monitoring (PCM) method is used to measure the rising microbubble after injection from a nozzle. Size and distribution curve of microbubbles are evaluated at different conditions such as pressure drop at intermediate valve, length of pipeline between saturation tank and nozzle and low pressure. And the efficiency is also checked when it collides with different size floc. The experimental results show the following fact. As the final pressure drop occurred closer to a nozzle, the bubble size became smaller. And small bubble collides with large floc as well as small one because of its physical characteristic. However large bubble collides well with large floc rather than small one since hydrodynamic flow in streamline interferes to collide between two. With performing computational process by mathematical model we have analyzed and verified the size effect between bubble and floc. Collision efficiency is the highest when P/B ratio shows in the range of 0.75 < P/B ratio ($R_{particle/Rbubble}$) < 2.0.

Suspended Solid Dispersion Analysis for Coastal Areas Using Hybrid Concept of Particle and Concentration of Eulerian-Lagrangian Model (Eulerian-Lagrangian 농도 및 입자 결합모형에 의한 연안의 부유사 확산해석)

  • 서승원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.2
    • /
    • pp.185-192
    • /
    • 1996
  • In order to simulate the coastal dispersion effectively, hybrid concept of operator split Eulerian-lagrangian concentration model and random-walk particle tracking model are developed. Especially the random-walk model is adequate for region with steep slope of concentration. According to model tests, it agrees perfectly with analytical solution on around the source point for therefore. ▽C $\geq$ 0.005, meanwhile it shows poor results for ▽C$\leq$0.002. trial modeling for real situation therefore, random-walk model is applied for near field henceforth Eulerian-Lagrangian concentration model is adoped for whole domain so that overall performance and accuracy can be achieved by using developed hybrid model.

  • PDF

Atomospheric Concentration and Mutagenicity of Nitroarenes of Suspended Particulates in Seoul (대기부유분진중 nitroarenes 오염도와 그 돌연변이원성에 관한 조사연구 - 서울시 일부지역을 중심으로 -)

  • Jo, Seong-Joon;Choi, Yong-Wook;Lim, Young-Wook;Shin, Dong-Chun;Chung, Yong
    • Environmental Analysis Health and Toxicology
    • /
    • v.5 no.3_4
    • /
    • pp.19-28
    • /
    • 1990
  • Nitroarenes are ubiquitous environmental pollutants displaying potent mutagenicity in bacteria and carcinogenicity in mammal. In this study, the concentration of nitroarenes in coarse and fine particles and mutagenicity of POC$\_$N/ fraction was investigated in suspended particulates at the Shinchon and Bulkwang area of Seoul. The suspended particulates were collected bimonthly by a high volume cascade impactor air sampler from July 1987 to May 1988. Extractable organic matter was obtained by ultrasonic extraction on diethly ether/cyclohexane (8/2, v/v). Neutral fraction was obtained by liquid-liquid extraction. Polar neutral organic compounds (POC$\_$N/) was fractionated by thin-layer chromatography. Finally, the concentrations of nitroarenes in POC$\_$N/ fraction were measured and determined by capillary gas chromatography. Direct and indirect mutagenicity of POC$\_$N/ fraction were measured using Salmonella typhimurium TA 98. The result were as follows: 1) Major nitroarenes at the Shinchon area was 1-nitropyrene and at the Bulkwang area it was 2,7-dinitro-9-fluorenone during the year. 2) Average concentration of total nitroarenes measured was 67.26 ng/m$^3$in fine particles which was 1,3 folds higher that in coarse particle (52.30 ng/m$^3$). 3) Annual pattern of nitroarenes concentrations revealed that concentration during heating season (Feb., Jan., Mar.) was 2.2 folds higher than that in non heating season (May, Jul., Sep.). Concentration of each season has 157.68 ng/m$^3$and 80.39 ng/m$^3$. 4) The mutagenic activity of POC$\_$N/ fraction from fine particles was higher compared to that of coarse particles and was increased when metabolically activated, with 59 mixture. Mutagenicities, Metabolically activated, were significantly different between Shinchon and Bulkwang area, 322.8 rev/250 $\mu\textrm{g}$/plate and 286.8 rev/250 $\mu\textrm{g}$/plate, respectively. 5) Annual pattern of mutagenicity of POC$\_$N/ fraction revealed that mutagenicity during the heating season was 1.7 folds higher at Shinchon area and 1.2 folds higher at Bulkwang than during the non heating season. The variable contents and levels of nitroarenes in suspended particulates may affect human health significantly. Further studies such as risk assessment should be conducted on the basis of these kind of studies.

  • PDF

Clustering of sediment characteristics in South Korean rivers and its expanded application strategy to H-ADCP based suspended sediment concentration monitoring technique (한국 하천의 지역별 유사특성의 군집화와 H-ADCP 기반 부유사 농도 관측 기법에의 활용 방안)

  • Noh, Hyoseob;Son, GeunSoo;Kim, Dongsu;Park, Yong Sung
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.1
    • /
    • pp.43-57
    • /
    • 2022
  • Advances in measurement techniques have reduced measurement costs and enhanced safety resulting in less uncertainty. For example, an acoustic doppler current profiler (ADCP) based suspended sediment concentration (SSC) measurement technique is being accepted as an alternative to the conventional data collection method. In Korean rivers, horizontal ADCPs (H-ADCPs) are mounted on the automatic discharge monitoring stations, where SSC can be measured using the backscatter of ADCPs. However, automatic discharge monitoring stations and sediment monitoring stations do not always coincide which hinders the application of the new techniques that are not feasible to some stations. This work presents and analyzes H-ADCP-SSC models for 9 discharge monitoring stations in Korean rivers. In application of the Gaussian mixture model (GMM) to sediment-related variables (catchment area, particle size distributions of suspended sediment and bed material, water discharge-sediment discharge curves) from 44 sediment monitoring stations, it is revealed that those characteristics can distinguish sediment monitoring stations regionally. Linking the two results, we propose a protocol determining the H-ADCP-SSC model where no H-ADCP-SSC model is available.

Characterization of Aerosol Concentration during Severe Asian Dust Period at Busan, Korea in 20 March 2010 (2010년 3월 20일 부산지역에 발생한 극심한 황사의 에어로솔 농도 분포 특성)

  • Jung, Woon-Seon;Park, Sung-Hwa;Lee, Dong-In;Kang, Deok-Du;Kim, Dongchul
    • Journal of Environmental Science International
    • /
    • v.23 no.2
    • /
    • pp.275-289
    • /
    • 2014
  • Asian dust (or yellow sand) occurring mainly in spring in East Asia is affected by the distribution of weather systems. This study was performed to investigate the characteristics of suspended particulate for Asian dust at Busan, Korea in 20 March 2010, which was one of the extreme case for the last 10 years. There was used the data of weather chart, satellite, automatic weather system (AWS), $PM_{10}$, laser particle counter (LPC), and backward trajectories model. In synoptically, the high pressure was located in the northwestern part and low pressure was located in the northeastern part of Korea. The strong westerly winds from surface to upper layer makes it possible to move air masses rapidly. Air masses passing through Gobi Desert in Mongolia and Inner Mongolia plateau covered the entire Korean peninsula. As the results of aerosol analysis, $PM_{10}$ concentration at Gudeok mountain in Busan was recorded $2,344{\mu}g/m^3$ in 2300 LST 20 March 2010 and their concentration was markedly increased at coarse mode particle. In surface condition, westerly wind about 3 ~ 5 m/s was dominant and small particles of $0.3{\sim}0.5{\mu}m$ were distributed on the whole. In heavy metal components analysis, the elements from the land was predominated.

Evaluation of removal performance of a novel two-stage cylinder type cyclone against water and oil droplets (2단 실린더형 싸이클론의 물 및 오일 액적 제거 성능 분석 연구)

  • Kim, Sumin;Kim, Hak-Joon;Kim, Myungjoon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.119-125
    • /
    • 2017
  • A novel two stage cylindrical cyclone was developed for a 3 phase separator in shale oil production industry. The cyclone performance was compared with a cone type cyclone and multi cyclone at the same experimental condition using water and oil mists generated by a humidifier and atomizer at the flow rate 1 to $2m^3/min$. The removal efficiency of total suspended water droplets by the novel cyclone, calculated using inlet and outlet concentrations measured by an optical particle counter, was 99% which is higher than 90% of oil droplet removal efficiency at $2m^3/min$. It might be due to the evaporation of small water droplets during the tests. The water and oil droplet removal performance of the novel cyclone based on the quality factor which is a function of pressure drop and removal efficiency was the highest among three cyclones. The results indicate that the cyclone could be an economical device to remove water and oil mists from shale gas generation processes where a huge three phase separator is commonly used.

Study on the Solvent Effect in the Coating of Conductive Polythiophene Derivative (용매에 따른 폴리싸이오펜 치환체의 전기전도성에 미치는 영향)

  • Pak, Na-Young;Lee, Seong-Min;Chung, Dae-Won
    • Elastomers and Composites
    • /
    • v.46 no.4
    • /
    • pp.290-294
    • /
    • 2011
  • The surface resistance of poly(3,4-ethylenedioxythiophene)-polystyrene sulfonate (PEDOT/PSS), which has appeared to be one of the most successful conductive polymers, is affected by the solvent. In this paper, pellet-type PEDOT/PSS was suspended in $H_2O$, ethanol (EtOH), ethylene glycol (EG) or dimethylsulfoxide (DMSO), and coated on PET film. The surface resistances of the films made from EG or DMSO suspension were observed to be lower, nearly by 2 orders of magnitude, than that made from $H_2O$ suspension. No significant difference among four kinds of films was observed when the thermal properties and chemical structures were investigated by TGA and XPS, respectively. However, particle size of PEDOT/PSS was in the range of $1-3{\mu}m$ in EG or DMSO, on the other hand, less than $0.1{\mu}m$ in $H_2O$. It is considered that the particle size of PEDOT/PSS in the suspension plays an important role for the surface resistance.

Analysis of Particles Motion in Vertical Rayleigh Flow (수직 Rayleigh 유동내의 입자 거동 해석)

  • Ko, Seok-Bo;Jun, Yong-Du;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.447-456
    • /
    • 2007
  • Suspended particles behavior when they go through a vertical riser with heat transfer is of significant concern to system designers and operators in pneumatic transport, various processes such as in chemical, pharmaceutical and food industries. When it comes with the energy system, that knowledge is critical to the reliable design practices of related equipment as heat exchangers, especially in the phase of system scale-up. Without haying a good understanding of the related physics, many scale-up practices based on their pilot plant experience suffer from unexpected behaviors and problems of unstable fluidization typically associated with excessive pressure drop, pressure fluctuation and even unsuccessful particle circulation. In the present study, we try to explain the observed phenomena with related physics, which may help understanding of our unanswered experiences and to provide the designers with more reliable resources for their work. We selected hot exhaust gas with solid particle that goes through a heat exchanger riser as our model to be considered. The effect of temperature change on the gas velocity, thermodynamic properties, and eventually on the particles motion behavior is reviewed along with some heat transfer analyses. The present study presents an optimal riser length at full scale under given conditions, and also defines the theoretical limiting length of the riser. The field data from the numerical analysis was validated against our experimental results.