• Title/Summary/Keyword: Survey meter

Search Result 172, Processing Time 0.024 seconds

Daily Water Intake and Exposure Parameters Related to the Multi-route Exposure in Drinking Water (음용수의 섭취량 및 다경로 노출평가를 위한 노출변수 조사연구)

  • Chung, Yong;Shin, Dong-Chun;Park, Seong-Eun;Choi, Shi-Nai;Park, Seon-Mee
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.19-29
    • /
    • 1996
  • Human exposure to volatile compounds in tap water can occur from inhalation and dermal absorption as well as direct ingestion. The relative contribution to total human exposure from these pathways has been considered to be important especially for VOC's (volatile organic compounds). In an attempt to reduce the uncertainty of the risk assessment, it has been suggested that the exposure assessment process could be significantly improved by adopting Monte-Carlo simulation. However, there is no actual data in Korea for each exposure parameter to determine the level of exposure, and the distributional pattern. Therefore, we surveyed water use patterns and behavior related to multi-route exposure to VOC's in household tap water in Korea, and compared these values to the those in western countries. In the first survey, we calculated daily water intake using data from a sample of 1322 persons of several cities in Korea. In the second survey, we obtained questionnaire data on exposure time for showering, bathing and household activities, and tap water intake from 851households in Korea. In the last survey, we measured the exposure parameters (exposure time, water use rate etc.) related to showers, baths, toilets, dish washing, washing and cooking, and tap water intake was surveyed. Also, the subjects were measured their body weight, height and tidal volume, etc. A diary, a flow meter and a measuring cup were used to measure these values as precisely as possible. Average daily water intake was ranged 0.79-1.71 L/day for adults in three surveys. Tap water intake measured by log-sheet during one week in third survey was 1.26 (average), 1.98 L/day (90 percentlie), respectively. These results were comparable with results from EPA (1.4, 2L/day). The average amount of water used by housewives in the third survey was 515.0 $\pm$ 564.6L/day. In usual activity, the amount of water used in the bathroom, the laundry and the kitchen was 140.0 $\pm$ 538.9, 148.0 $\pm$ 174.5, 229.3 $\pm$ 205.4 L/day, respectively. Exposure parameters such as water intake rate, exposure duration, body weight, inhalation rates in surveyed data of Korean people differed from those published from western countries. This could be attributed to variations in lifestyle, dietary habits and physiological characteristics.

  • PDF

Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling (쉴드 TBM터널 상부 지반 연약대 전기탐사)

  • Jung, Hyun-Key;Park, Chul-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

Analysis on the Survey of Skin Types According to Vata, Pitta, Kapha Constitution in Ayurveda (아유르베다의 바타(Vata), 피타(Pitta), 카파(Kapha) 체질에 따른 피부 유형 조사 분석)

  • Kim, Young-Mi;Choi, Eun-Young;Chang, Byung-Soo
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.2
    • /
    • pp.19-26
    • /
    • 2009
  • Objectives : This study was investigated to the relationship ayurvedic constitution and each skin hydration and pH. Methods : The questionaire survey and skin analysis of female students attending university located in Chugnam was carried out in order to assess skin types according to ayurvedic constituion such as vata, pitta and kapha. Data analysis were used describe statistics, ANOVA in Duncan's multiple comparative test and Pearson's correlation by SPSS. Skin hydration and pH was measured by Corneometer and skin-pH meter. Results : The results of this study are as follows. First, in terms of knowledge of ayurvedic constitutional types most students are not aware of that. Second, the most common constitution in the ayurveda medical system was pitta. Third, in the analysis of skin type by constitution of ayurveda, vata had dry skin while pitta and kapha tended to have more combination skin. However, this result didn't show any statistically significant difference either. Forth, the analysis of skin tone by constitution of ayurveda showed that vata was white, and pitta and kapha were just average. Discussion and Conclusion : The results of this study was shown that the difference between Korean and Indian, so we should develop effective diagnosis tool for Korean people. In the future, we expect that ayurvedic skin and body program developed by this study spread and practical use at esthetic industry and domain of esthetics in Korea.

  • PDF

Systematic Development and Effect Estimation of the Functional Insoles for Seniors (시니어전용 기능성 깔창의 체계적인 개발 및 효과분석)

  • Kim, Yong-Deok;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.184-192
    • /
    • 2015
  • Korea has already entered into an aging society. In recent decades, the health problems for seniors has received considerable interest. We often see the elderly who have been struggled from discomfort or illness of the foot. Those foot related problems mainly cause from the use of improper shoes. Recently, shoe makers sell the shoes for seniors, so called comfort shoes, but the shoes are too expensive for seniors to buy easily. In this paper, we develop cheap insoles for seniors as an alternative of the comfort shoes and suggest the systematic process for the insoles development. This systematic process is as follows: 1) Survey the literature about the market of insole, 2) Investigate the standard size of body and foot for the seniors in Korea, 3) Analyze the customer needs by survey, 4) Study the walking pattern by experiments, and 5) Develop the novel insole for the seniors to relieve the inconveniences related with foot. From the newly developed insoles, the company B gains the sales increasing effect approximately 30% over through the increase in consumer satisfaction and company reputation and secures for intellectual property rights. Using the database from Korea Research Institute of Standards and Science, the reliability of developing technology of the functional insole has been obtained. The seniors are also enable to choose an alternative of comfort shoes for foot health. In the future, the insoles developed from this study have wide applications in the medical, cosmetic fields, and leisure sports fields. Accordingly, it seems to require more systematic studies utilizing Walk Analyzer and Foot Pressure Meter.

Evaluation Tools for Patients with Neurologic Disorders Based on the ICF Model: A Survey of Korean Physical Therapists (ICF 모델 기반 신경계 환자 물리치료 평가 도구 사용 조사)

  • Lee, Ji-ah;Woo, Yong-Keun;Won, Jong-Im;Kim, Su-jin
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.359-370
    • /
    • 2022
  • Purpose: Physical therapists are required to properly choose the most appropriate treatment for each patient within the framework of the International Classification of Functioning, Disability, and Health (ICF model). The aims of this study were to determine whether neurological physical therapists in clinical settings in South Korea know about the ICF model and to investigate the current trends of outcome measures (OMs) used by them. Methods: Two hundred and one physical therapists who worked with patients with neurological disorders participated in this study. The survey was conducted via e-mail and asked about commonly used OMs and the considerations for selecting OMs. Results: All physical therapists involved in this study responded completely, and 45.8% of participants learned about the ICF model, while 37.3% understood the detailed information related to the ICF model. The rest of the participants did not know or just heard about the ICF model. The most frequently used tools at the body function/structure level were the Range of Motion (98%), Manual Muscle Test (97%), Berg Balance Scale (83.1%), and Modified Ashworth Scale (70.6%) when allowing repetition. At the activity level, the 10-meter walk test (71.1%), 6-minute walk test (54.2%), and Functional Ambulatory Category (43.3%) were used, while the Activity-Specific Balance Confidence Scale (23.9%) was used at the participation level. There was a positive relationship between the number of tools used and years of work, as well as the level of understanding of the ICF model. Conclusion: The results of this study suggest that it is necessary to learn the ICF model in a clinical setting. In addition, the medical system needs to be modified to encourage physical therapists in South Korea to use proper OMs within the ICF model.

A study on the commercialization cause of 2nd class residential area in urban center (도시거점내 제2종 일반주거지역 상업화 확산과 원인 분석)

  • Yoon, Yong-Suk;Yang, Woo-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.147-152
    • /
    • 2011
  • The purpose of this study is to find out the commercialization cause of 2nd class residential area in urban center as basic research to protect urban residential area against the pressure of commercialization. Through the research that are based on literature, field survey and urban planning map, it analysed the commercialization cause of selected two sites under similar urban condition ; to be a nearby subway station and to be a famous commercial street in site, etc. The consequences of this study are summarized as follows ; First the distance between subway station and residential block and residential commercialization are in inverse proportion each other. Second, the corner lot of a block and the access street directly connected collector street are very important factors to spread commercialization to residential area. Finally, nevertheless first and second results, there is square zone which is very high rate of commercialization within one regardless the distance between subway and residential block. the maximum range of square zone is assumed about 250 meter based on case study.

  • PDF

SHIELD DESIGN OF CONCRETE WALL BETWEEN DECAY TANK ROOM AND PRIMARY PUMP ROOM IN TRIGA FACILITY

  • Khan, M J H;Rahman, M;Ahmed, F U;Bhuiyan, S I;Haque, A;Zulquarnain, A
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.190-193
    • /
    • 2007
  • The objective of this study is to recommend the radiation protection design parameters from the shielding point of view for concrete wall between the decay tank room and the primary pump room in TRIGA Mark-II Research Reactor Facility. The shield design for this concrete wall has been performed with the help of Point-kernel Shielding Code Micro-Shield 5.05 and this design was also validated based on the measured dose rate values with Radiation Survey Meter (G-M Counter) considering the ICRP-60 (1990) recommendations for occupational dose rate limit ($10{\mu}Sv/hr$). The recommended shield design parameters are: (i) thickness of 114.3 cm Ilmenite-Magnetite Concrete (IMC) or 129.54 cm Ordinary Reinforced Concrete (ORC) for concrete wall A (ii) thickness of 66.04 cm Ilmenite-Magnetite Concrete (IMC) or 78.74 cm Ordinary Reinforced Concrete (ORC) for concrete wall B and (iii) door thickness of 3.175 cm Mild Steel (MS) on the entrance of decay tank room. In shielding efficiency analysis, the use of I-M concrete in the design of this concrete wall shows that it reduced the dose rate by a factor of at least 3.52 times approximately compared to ordinary reinforced concrete.

Analysis of Noise Environment of Cafe Occupants According to Interior Finishing (실내 인테리어 마감재에 따른 카페 재실자의 소음 환경 영향 분석)

  • Lee, Soo Han;Yun, Huiseung;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.4
    • /
    • pp.355-361
    • /
    • 2017
  • Indoor noise environment is an important factor when it comes to occupants comfort, especially in cafe. Results of the survey, 33.9% of occupants were feel unpleasant and sensitive about noise environment. Noise in cafe fluctuate depending on the finishing of both wall and ceiling, volume of the room, and the number of occupants in the room. Therefore, the noise meter device was used for measurement of various under conditions. Also, the subjective assessment of occupant noise was conducted through questionnaires. When the interior finish was exposed concrete, the maximum value of the noise measurement was 66.6 dB and the minimum value was 63 dB, respectively. Also, the result of subjective assessment of unpleasant noise were 5.43 and 4.96 point of 10 point of noise and echo, respectively. Otherwise, the interior finish was gypsum board, the maximum value of the noise measurement was 73.8 dB and the minimum value was 60.4 dB, respectively. Also, the result of subjective assessment of unpleasant noise were 3.88 and 3.95 point of 10 point of noise and echo, respectively. The results of the study showed that the noises and echoes in the cafes were lower than when did not.

MONITORING OF MOUNTAINOUS AREAS USING SIMULATED IMAGES TO KOMPSAT-II

  • Chang Eun-Mi;Shin Soo-Hyun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.653-655
    • /
    • 2005
  • More than 70 percent of terrestrial territory of Korea is mountainous areas where degradation becomes serious year by year due to illegal tombs, expanding golf courses and stone mine development. We elaborate the potential usage of high resolution image for the monitoring of the phenomena. We made the classification of tombs and the statistical radiometric characteristics of graves were identified from this project. The graves could be classified to 4 groups from the field survey. As compared with grouping data after clustering and discriminant analysis, the two results coincided with each other. Object-oriented classification algorithm for feature extraction was theoretically researched in this project. And we did a pilot project, which was performed with mixed methods. That is, the conventional methods such as unsupervised and supervised classification were mixed up with the new method for feature extraction, object-oriented classification method. This methodology showed about $60\%$ classification accuracy for extracting tombs from satellite imagery. The extraction of tombs' geographical coordinates and graves themselves from satellite image was performed in this project. The stone mines and golf courses are extracted by NDVI and GVI. The accuracy of classification was around 89 percent. The location accuracy showed extraction of tombs from one-meter resolution image is cheaper and quicker way than GPS method. Finally we interviewed local government officers and made analyses on the current situation of mountainous area management and potential usage of KOMPSAT-II images. Based on the requirement analysis, we developed software, which is to management and monitoring system for mountainous area for local government.

  • PDF

The Study on Decline Plan of Primary Production Organic Matter of Uiam Lake Basin (의암호 유역에서 발생하는 자체생산 유기물 저감방안에 관한 연구)

  • 허인량;이건호;함광준;최지용;정의호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.1
    • /
    • pp.50-58
    • /
    • 2004
  • The present study was designed to evaluate primary production organic matter in basin of lake around by execution of total maximum daily loading. BOD influent loading of Uiam lake was 2,819 kg/day, which was less then 28.3 percent, total effuluent loading as 3,619 kg/day, in comparision with BOD, total nitrogen influent loading was 4,681 kg/day, which was less then 10.0 percent, total effuluent loading as 5,150 kg/day. But in case of total phosphors influent loading was 73.3 kg/day, which was more then 34.2 percent, total run off loading as 48.3 kg/day. The result of survey reduction plan of primary production organic matter in basin of lake around which objectives of abstract is as follows. First plan was reduction of primary production organic matter by moving the outlet of municipal wastewater treatment center from present place to lake downstream. Secondary plan was improvement by diffusion type of outlet municipal wastewater treatment center. The third plan was reduction of environmental impact by passing and storing of municipal wastewater. Finally plan was decline water surface level which was present hydrouric retention time was reduction from 7.6 day to 6.0 day per meter.