Fine Structural Modification of Mouse Ovarian Tissue by Irradiation of 6 MeV LINAC Radiation (6 MeV LINAC 방사선 조사에 의한 생쥐 난소조직의 미세구조 변화)

  • Yoon, Chul-Ho;Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.33 no.2
    • /
    • pp.117-130
    • /
    • 2003
  • This research investigates the fine structural as well as the morphological changes of the mouse ovarian tissue after irradiation of various dose rates of 6 MeV LINAC radiation. The normal structure of the ovarian tissue is consisted of various stages of follicles including primordial and growing follicles, and ovarian stromal connectives. When we observed the ovarian tissues irradiated with a dose rate of 200 cGy/min using light and electron microscopes, granular cells in growing follicles are in irregular shape unlike normal follicles. Small segments of cells scattered in follicular antrum among granular cells. We could observe neutrophils and macrophages around the segments, which means the cells already got in the process of decease owing to the effects radiation. With coincident to the increase of the dose rate of x-ray irradiation as 400 or 600 cGy/min, the mature follicles appeared as an irregular form and the granular cells surrounding oocyte also deformed comparing to their normal counterparts. The granulosa cells within mature follicle are already occurred necrotic change and apoptosis. The nuclei in some cells got so fragmented that the segments formed the shape of a horseshoe or scattered in small and condensed pieces. All the cells at a granular layer irradiated with a dose rate of 600 cGy/min show typical characteristics of apoptosis. The neutrophils involved in inflammatory reaction appear evidently in follicular antrum of growing follicles, and macrophage scattered with residual and apoptotic bodies.

Effects of Arc Number or Rotation Range upon Dose Distribution at RapidArc Planning for Liver Cancer (간암환자를 대상으로 한 래피드아크 치료계획에서 아크수 및 회전범위가 선량분포에 미치는 영향)

  • Park, Hae-Jin;Kim, Mi-Hwa;Chun, Mi-Son;Oh, Yeong-Teak;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.165-173
    • /
    • 2010
  • In this paper, we evaluated the performance of 3D CRT, IMRT and three kind of RA plannings to investigate the clinical effect of RA with liver cancer case. The patient undergoing liver cancer of small volume and somewhat constant motion were selected. We performed 3D CRT, IMRT and RA plannings such as 2RA, limited triple arcs (3RA) and 3MRA with Eclipse version 8.6.15. The same dose volume objectives were defined for only CTV, PTV and body except heart, liver and partial body in IMRT and RA plannings. The steepness of dose gradient around tumor was determined by the Normal Tissue Objective function with the same parameters in place of respective definitions of dose volume objectives for the normal organs. The approach between the defined dose constraints and the practical DVH of CTV, PTV and Body was the best in 3MRA and the worst in IMRT. The DVHs were almost the same among RAs. Plans were evaluated using Conformity Index (CI), Homogeneity Index (HI) and Quality of coverage (QoC) by RTOG after prescription with dose level surrounding 98% of PTV in the respective plans. As a result, 3MRA planning showed the better favorable indices than that of the others and achieved the lowest MUs. In this study, RA planning is a technique that is possible to obtain the faster and better dose distribution than 3D CRT or IMRT techniques. Our result suggest that 3MRA planning is able to reduce the MUs further, keeping a similar or better targer dose homogeneity, conformity and sparing normal tissue than 2RA or 3RA.

Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy (고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정)

  • Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.98-103
    • /
    • 2014
  • Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

  • PDF

Effect of Fiber Number Per Mass Concentration in Korean Produced Asbestos on Lung Function and Pathology (중량당 섬유수가 다른 국내산 석면이 폐 기능과 폐 조직에 미치는 영향 평가)

  • Chung, Yong Hyun;Han, Jeong Hee;Kang, Min Gu;Kim, Jong Kyu;Yang, Jeong Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.301-308
    • /
    • 2012
  • Objectives: To evaluate the pulmonary toxicity of 2 Korea asbestos(chrysotile, anthophyllite), Sprague-Dawely rats were exposed to 2 mg domestic asbestos by intratracheal instillation(IT). Methods: Lung function of rats was analyzed by pressure transducer(MAX1320, Buxco Electronics, USA). The effects of 2 mg asbestos(chrysotile ; $8,814,244{\times}10^{6}$ fibers/mg, average diameter 0.08 ${\mu}m$, average length 4.39 ${\mu}m$, anthophyllite ; $5,182{\times}10^{6}$ fibers/mg, average diameter 0.95 ${\mu}m$, average length 7.29 ${\mu}m$) on pulmonary function and pathological changes were evaluated at after a single IT. Lung function and histopathological evaluation were assessed in 5 animals from each group at each time point. Results: Due to differences in fiber numbers, chrysotile induce marked lung pathology and lung function change than anthophyllite at the same mass dose. Chrysotile showed notable thickening of interstitial areas surrounding the alveolar ducts and terminal bronchioles. Conclusions: On a mass dose basis, chrysotile that have 1,700 times numbers of fibers per unit weight than anthophyllite produced a greater persistent lung injury than anthophllite for at least 4 weeks after exposure.

Gamma-ray Dosimetry with Thin Plastic Film

  • Yoo, Young-Soo;Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.223-233
    • /
    • 1973
  • Thirty two different kinds of domestic plastic films for use in measuring high gamma-ray dose have been collected and their dosimetric characteristics investigated with the help of a Co-60 gamma radiation source. Among them a rigid polyvinyl chloride(PVC) film of 0.06mm in thickness which is manufactured by Lucky Chemical Co., Korea, seem to be the most suitable one for this purpose. The relation between optical density at 3100$\AA$ and radiation exposure in this PVC film was linear in the range of 0.6$\times$10$^{6}$ R to 1.3$\times$10$^{7}$ R, and also the film showed a good reproducibility within 9% under the standard experimental condition. The effect of absorbed dose, oxygen content of surrounding atmosphere and irradiation temperature have also been studied for this film. It appeared to have a good property in the dosimetrical point of view.

  • PDF

Effect of Chlorination on Disinfection Byproducts Production and Release of Microcystins from Bloom-forming Algae (녹조현상 원인조류들의 염소처리에 의한 소독부산물 생성 및 microcystins 유출)

  • Park, Hae-Kyung;Seo, Yong-Chan;Cho, Il-Hyung;Park, Byung-Hwang
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.513-520
    • /
    • 2006
  • The effect of chlorination on disinfection byproducts (DBPs) production from bloom-forming freshwater algae including 7 strains of cyanobacteria and 6 strains of diatoms was investigated. The release and degradation of hepatotoxin (microcystins) by the chlorination on Microcystis under differential condition of the chlorination time and dose were also investigated. The disinfection byproducts formation potentials (DBPFP) of cyanobacterial species and diatoms were ranged from 0.017 to $0.070{\mu}mol\;DBPs/mg$ C and from 0.129 to $0.708{\mu}mol\;DBPs/mg$ C respectively. Among three major groups of DBPs, haloacetonitrils (HANs) was major product in most test strains except Aphanizomenon sp. and Oscillatoria sp. Haloacetic acids (HAAs) was less than 5 % of total DBPs. Chloroform and dichloroacetonitril (DCAN) were dominant compounds in trihalomethanes (THMs) and HANs respectively. After 4 hours chlorination of toxic Microcystis aeruginosa under the dose range of 0.5 to $10mg\;Cl_2/L$, the concentration of intracellular microcystins decreased, but dissolved dissolved microcystins concentration increased with the treatment of more than $3mg\;Cl_2/L$. However the total amount of microcystins was almost constant even at $10mg\;Cl_2/L$ of chlorination. To conclude, our results indicate that the chlorination causes algal cell lysis and release of intracellular microcystins in the intact form to surrounding waters.

Radiological Assessment of Environmental Impact of the IF-System Facility of the RAON

  • Lee, Cheol-Woo;Whang, Won Tae;Kim, Eun Han;Han, Moon Hee;Jeong, Hae Sun;Jeong, Sol;Lee, Sang-jin
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.2
    • /
    • pp.58-65
    • /
    • 2021
  • Background: The evaluation of skyshine distribution, release of airborne radioactive nuclides, and soil activation and groundwater migration were required for radiological assessment of the impact on the environment surrounding In-Flight (IF)-system facility of the RAON (Rare isotope Accelerator complex for ON-line experiment) accelerator complex. Materials and Methods: Monte Carlo simulation by MCNPX code was used for evaluation of skyshine and activation analysis for air and soil. The concentration model was applied in the estimation of the groundwater migration of radionuclides in soil. Results and Discussion: The skyshine dose rates at 1 km from the facility were evaluated as 1.62 × 10-3 μSv·hr-1. The annual releases of 3H and 14C were calculated as 9.62 × 10-5 mg and 1.19 × 10-1 mg, respectively. The concentrations of 3H and 22Na in drinking water were estimated as 1.22 × 10-1 Bq·cm-3 and 8.25 × 10-3 Bq·cm-3, respectively. Conclusion: Radiological assessment of environmental impact on the IF-facility of RAON was performed through evaluation of skyshine dose distribution, evaluation of annual emission of long-lived radionuclides in the air and estimation of soil activation and groundwater migration of radionuclides. As a result, much lower exposure than the limit value for the public, 1 mSv·yr-1, is expected during operation of the IF-facility.

Evaluation of the accuracy of mobile cone-beam computed tomography after spinal instrumentation surgery

  • Eom, Ki Seong;Park, Eun Sung;Kim, Dae Won;Park, Jong Tae;Yoon, Kwon-Ha
    • Journal of Trauma and Injury
    • /
    • v.35 no.1
    • /
    • pp.12-18
    • /
    • 2022
  • Purpose: Pedicle screw fixation provides 3-column stabilization, multidimensional control, and a higher rate of interbody fusion. Although computed tomography (CT) is recommended for the postoperative assessment of pedicle screw fixation, its use is limited due to the radiation exposure dose. The purpose of this preliminary retrospective study was to assess the clinical usefulness of low-dose mobile cone-beam CT (CBCT) for the postoperative evaluation of pedicle screw fixation. Methods: The author retrospectively reviewed postoperative mobile CBCT images of 15 patients who underwent posterior pedicle screw fixation for spinal disease from November 2019 to April 2020. Pedicle screw placement was assessed for breaches of the bony structures. The breaches were graded based on the Heary classification. Results: The patients included 11 men and four women, and their mean age was 66±12 years. Of the 122 pedicle screws, 34 (27.9%) were inserted in the thoracic segment (from T7 to T12), 82 (67.2%) in the lumbar segment (from L1 to L5), and six (4.9%) in the first sacral segment. Although there were metal-related artifacts, the image of the screw position (according to Heary classification) after surgery could be assessed using mobile CBCT at all levels (T7-S1). Conclusions: Mobile CBCT was accurate in determining the location and integrity of the pedicle screw and identifying the surrounding bony structures. In the postoperative setting, mobile CBCT can be used as a primary modality for assessing the accuracy of pedicle screw fixation and detecting postoperative complications.

Minimization of Treatment Time Using Partial-Arc Volumetric Modulated Arc Therapy with Bladder Filling Protocol for Prostate Cancer

  • Hojeong Lee;Dong Woon Kim;Ji Hyeon Joo;Yongkan Ki;Wontaek Kim;Dahl Park;Jiho Nam;Dong Hyeon Kim;Hosang Jeon
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.101-107
    • /
    • 2022
  • Purpose: Radiotherapy after bladder filling protocol (BFP) is known to enhance treatment quality and reduce side effects in prostate cancer, a common male solid cancer globally. However, due to the need to hold back urine during treatment, patients frequently complain of discomfort, and treatment is frequently suspended when patients urinate during treatment and urine penetrates the treatment device, causing malfunction. Therefore, the effect of minimizing treatment time when partial-arc volumetric modulated arc therapy (VMAT) was used instead of full-arc was assessed in this study. Methods: A total of 70 plans were created in 10 patients using 7 different arc sizes, and the treatment time for each plan was calculated. Results: Reduced arc size by half resulted in a 54.4% decrease in mean treatment duration, with a proportional tendency observed. Furthermore, the effect of VMAT arc size reduction on target dose homogeneity was significantly limited, and the effect on surrounding organs at risk (OAR) was negligible. It should be noted, however, that when the arc size decreases by >40%, the dose increases in the area without OAR around the target. Conclusions: The results of this study demonstrated that partial-arc VMAT for enhancing treatment convenience and efficacy of prostate cancer patients undergoing BFP can achieve a considerable reduction in treatment time while preserving treatment quality, and it is expected to be useful for partial-arc VMAT plan design and implementation in practice.

The effect of indomethacin on the matrix metalloproteinases in canine permanent tooth eruption (인도메타신의 투여가 치아 맹출 시 기질금속단백분해 효소의 분포에 미치는 영향)

  • Kang, Yoon-Goo;Nam, Jong-Hyun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.91-102
    • /
    • 2006
  • Tooth eruption requires remodeling of surrounding tissues. This study was aimed to investigate the effect of indomethacin on the dental follicle and paradental tissues during tooth eruption by observing the distribution and expression of MMP by the immunohistochemical method. Ten mongrel dogs of ten to twelve weeks old were divided into 5 groups; four experimental groups administered indomethacin 2 mg/Kg/day and 8 mg/Kg/day orally 2 times a day for 14 days and 7 days respectively, and the control group was administered a placebo. Permanent teeth before eruption and their surrounding tissues were selected and excised. H&E staining and immunohistochemical stainings of MMP-3 and -9 were performed and examined under the light microscope. Osteoclasts, osteoblasts, periodontal ligament cells, ameloblasts and odontoblasts of the control group all expressed MMP-3 and -9. In the experimental group, osteoclasts, osteoblasts and periodontal ligament cells showed reduced expression of MMP-3 and -9. Magnitude of MMP reduction In the experimental group showed a time and dose of indomethacin administration dependent manner. These results show that indomethacin inhibited MMP-3 and -9 expression in the dental follicle and surrounding tissues and suggest that when indomethacin is administered for long periods, tooth eruption could be delayed.