• Title/Summary/Keyword: Surplus electric power

Search Result 39, Processing Time 0.023 seconds

Design of a Cooperative Voltage Control System Between EMS (VMS) and DMS

  • Shin, Jeonghoon;Lee, Jaegul;Nam, Suchul;Song, Jiyoung;Oh, Seungchan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.279-284
    • /
    • 2020
  • This paper presents the conceptual design of a cooperative control with Energy Management System (EMS) and Distribution Management System (DMS). This control enables insufficient reactive power reserve in a power transmission system to be supplemented by surplus reactive power in a power distribution system on the basis of the amount of the needed reactive power reserve calculated by the EMS. This can be achieved, because increased numbers of microgrids with distributed energy resources will be installed in the distribution system. Furthermore, the DMS with smart control strategy by using surplus reactive power in the distribution system of the area has been gradually installed in the system as well. Therefore, a kind of hierarchical voltage control and cooperative control scheme could be considered for the effective use of energy resources. A quantitative index to evaluate the current reactive power reserve of the transmission system is also required. In the paper, the algorithm for the whole cooperative control system, including Area-Q Indicator (AQI) as the index for the current reactive power reserve of a voltage control area, is devised and presented. Finally, the performance of the proposed system is proven by several simulation studies.

Optimal Design of Urban MICROGRID using Economical Analysis Program (경제성분석 프로그램을 이용한 도심형 마이크로그리드 최적 설계)

  • Seung-Duck, Yu;SungWoo, Yim;Youseok, Lim;SungWook, Hwang;JuHak, Lee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.69-72
    • /
    • 2022
  • This paper actually investigates the load on major large-scale buildings in the downtown area, examines the economic feasibility of installing PV and ESS in a microgrid target building, and evaluates whether an electric vehicle capable of V2G through two buildings is effective as an economical analysis program (HOMER) was analyzed using. It is economical to install a mixture of ESS rather than using the whole PV, and it is shown that if there is an electric vehicle using the V2G function of EV, there is an economic effect to replace the PV. So that Incentives and policies are needed to replace a large area of PV and utilize the existing parking lot to lead EV as a resource of the microgrid. Currently, P2X technology that stores power as ESS or converts it to other energy to control when surplus renewable energy occurs in large-capacity solar power plants and wind farms, etc. This is being applied, and efforts are being made to maintain the stability of the system through the management of surplus power, such as replacing thermal energy through a heat pump. Due to the increase in electric vehicles, which were recognized only as a means of transportation, technologies for using electric vehicles are developing. Accordingly, existing gas stations do not only supply traditional chemical fuels, but electricity, and super stations that also produce electricity have appeared. Super Station is a new concept power plant that can produce and store electricity using solar power, ESS, V2G, and P2G. To take advantage of this, research on an urban microgrid that forms an independent system by tying a large building and several buildings together and supplies power through a super station around the microgrid is in full swing.

Analysis of Energy Saving Effect of the Residential BESS Connected to the Balcony-PV in Apartment Houses (공동주택 발코니 PV 연계 가정용 BESS의 에너지 절감 효과 분석)

  • Kim, Cha-Nyeon;Eum, Ji-Young;Kim, Yong-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.3
    • /
    • pp.21-31
    • /
    • 2020
  • The government mandates gradually zero energy building and Photovoltaic power generation systems installed in buildings are emerging as the most realistic alternative to increase the independence rate of building energy. In this study, we propose a method to reduce the power consumption of households by increasing the PV capacity of balconies and applying the method used the charged electric power stored in batteries after sunset. In order to evaluate the electric power energy savings of the residential BESS, a balcony PV 1.2 kW and a battery pack 2 kWh were installed for 9 houses in 4 apartments in Seoul and Gyeonggi-do. The BESS is charged when the balcony PV is generated electric power, and when solar power generation is finished, it supplies power to the electric appliances connected to the load. As a result of installing the solar PV module 1.2 kW and 2 kWh class BESS for 3 households located in Seoul and Gyeonggi-do, the average electric power consumption saving rate was 40%. The reduction in electricity consumption in the case of zero generation surplus power by maximizing the utilization rate of BESS has been improved to about 53%. Therefore, in order to increase the self-sufficiency rate of electric energy in apartment houses, it is effective to increase the solar photovoltaic capacity of the balcony and apply the residential BESS. In the future, it is believed that the balcony PV and home BESS will play a key role in achieving mandatory zero-energy housing.

A Study on Proposing Practicable Configurations against Propeller Racing for SOFC/GT Hybrid System in Ships (프로펠러 레이싱에 대비한 SOFC/GT 하이브리드시스템의 대책 방안에 관한 기초적 연구)

  • Kim, Myoung-Hwan;Lim, Tae-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.256-261
    • /
    • 2008
  • The purpose of this study is to propose practicable configurations against Rapid Load Down like propeller racing of ships which have been using SOFC/GT hybrid system on board. This paper suggests four kinds of countermeasures against propeller racing. The types A and B keep a fixed load of SOFC and save a surplus electric power to a storage system. In types of C and D, the load of SOFC is changed with the propeller racing. The best desirable countermeasure for Rapid Load Down depends upon the size of the ship, the propulsion power, and the characteristics of the engine system.

A Study on Power Trading Methods for in a Hydrogen Residential Model (수소주거모델의 전력 거래 참여 방안 고찰)

  • KISEOK JEONG;TAEYOUNG JYUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.91-99
    • /
    • 2023
  • Participation in power trading using surplus power is considered a business model active in the domestic energy trade market, but it is limited only if the legal requirements according to the type, capacity, and use of the facilities to be applied for are satisfied. The hydrogen residential demonstration model presented in this paper includes solar power, energy storage system (ESS), fuel cell, and water electrolysis facilities in electrical facilities for private use with low-voltage power receiving system. The concept of operations strategy for this model focuses on securing the energy self-sufficiency ratio of the entire system, securing economic feasibility through the optimal operation module installed in the energy management system (EMS), and securing the stability of the internal power balancing issue during the stand-alone mode. An electric facility configuration method of a hydrogen residential complex demonstrated to achieve this operational goal has a structure in which individual energy sources are electrically connected to the main bus, and ESS is also directly connected to the main bus instead of a renewable connection type to perform charging/discharging operation for energy balancing management in the complex. If surplus power exists after scheduling, participation in power trading through reverse transmission parallel operation can be considered to solve the energy balancing problem and ensure profitability. Consequentially, this paper reviews the legal regulations on participation in electric power trading using surplus power from hydrogen residential models that can produce and consume power, gas, and thermal energy including hybrid distributed power sources, and suggests action plans.

GAME MODEL AND ITS SOLVING METHOD FOR OPTIMAL SCALE OF POWER PLANTS ENTERING GENERATION POWER MARKET

  • Tan, Zhongfu;Chen, Guangjuan;Li, Xiaojun
    • Journal of applied mathematics & informatics
    • /
    • v.26 no.1_2
    • /
    • pp.337-347
    • /
    • 2008
  • Based on social welfare maximum theory, the optimal scale of power plants entering generation power market being is researched. A static non-cooperative game model for short-term optimization of power plants with different cost is presented. And the equilibrium solutions and the total social welfare are obtained. According to principle of maximum social welfare selection, the optimization model is solved, optimal number of power plants entering the market is determined. The optimization results can not only increase the customer surplus and improve power production efficiency, but also sustain normal profits of power plants and scale economy of power production, and the waste of resource can also be avoided. At last, case results show that the proposed model is efficient.

  • PDF

Settlement Technique of Constrained On/Off Compensation Amount using Surplus Function in Electricity Market (잉여함수를 이용한 전력시장에서의 제약보상금액 정산기법)

  • 국경수;문영환;오태규
    • Journal of Energy Engineering
    • /
    • v.11 no.4
    • /
    • pp.324-331
    • /
    • 2002
  • ln competitive electricity market, useful technique would be required to calculate settlement amount for electric power traded between market participants and KPX since a number of market partici-pants would appear and trade electric power. Especially calculation of constrained on/off compensation amount can be complicated, and needs to be understood clearly by market participants to avoid unnecessary disputes. This paper presents a technique to settle more easily constrained on/off compensation amount using surplus function. In this technique, a surplus is calculated by each dispatched values and then the compen-sation amount is calculated by the difference of each surpluses. By doing this, settlement amount can be cal-culated by summing the trading amount and the compensation amount.

Estimation of Electric Power Trading Price between Prosumer and Consumer Under Time-of-Use (TOU) (계시별 전기요금에서의 프로슈머와 소비자간 전력거래 가격추정)

  • Lee, Yungjoon;Park, Soojin;Yoon, Yongbeum
    • New & Renewable Energy
    • /
    • v.17 no.2
    • /
    • pp.1-8
    • /
    • 2021
  • We estimated the price range of electricity transactions under the prosumer system, considering the spread of renewable energy and the prospect of introducing a surplus power trading system between power consumers in Korea. The range (min/max) of power transaction prices was estimated by prosumers and consumers who could purchase electricity from utilities if needed. It is assumed that utilities purchased electricity from prosumers and consumers under a Time-of-Use (TOU) rate, trading at a monthly price. The range of available transaction prices according to the amount of power purchased from utilities and the amount of transaction power was also estimated. The price range that can be traded is expected to vary depending on variables such as the TOU rate, purchased and surplus power, levelized cost of electricity, etc.

A Study on DC Power Regeneration for Railway using Parallel PWM Converter (병렬 PWM 컨버터를 이용한 철도차량 직류 전력 회생장치에 관한 연구)

  • Lee Jong-Moo;Jang Su-jin;Song Sang-Hun;Won Chung-Yuen;Ahn Kyu-Bok;Lee Joon-Gee
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.524-527
    • /
    • 2004
  • When the electric tractions are stopped or driven through the falling slope way, it occured to surplus energy in the DC power line. At present, these energy are exhausted by breaking-system. The converter is not only capable of feeding energy back into the AC source during excessive regeneration. It is issued for this surplus energy regenerating system. These systems are faced with high voltage and high power for railway DC power regeneration. This paper proposed a parallel PWM converter how to solve these problem.

  • PDF

Performance Evaluation and Optimization of Hydrogen Liquefaction Process Using the Liquid Air for Pre-Cooling (액화공기(Liquid Air) 예냉기반 수소액화공정 성능 해석 및 최적화)

  • PARK, SUNGHO;AHN, JUNKEON;RYU, JUYEOL;KO, AREUM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.490-498
    • /
    • 2019
  • The intermittent electric power supply of renewable energy can have extremely negative effect on power grid, so long-term and large-scale storage for energy released from renewable energy source is required for ensuring a stable supply of electric power. Power to gas which can convert and store the surplus electric power as hydrogen through water electrolysis is being actively studied in response to increasing supply of renewable energy. In this paper, we proposed the novel concept of hydrogen liquefaction process combined with pre-cooling process using the liquid air. It is that hydrogen converted from surplus electric power of renewable energy was liquefied through the hydrogen liquefaction process and vaporization heat of liquid hydrogen was conversely recovered to liquid air from ambient air. Moreover, Comparisons of specific energy consumption (kWh/kg) saved for using the liquid air pre-cooling was quantitatively conducted through the performance analysis. Consequently, about 12% of specific energy consumption of hydrogen liquefaction process was reduced with introducing liquid air for pre-cooling and optimal design point of helium Brayton cycle was identified by sensitivity analysis on change of compression/expansion ratio.