• Title/Summary/Keyword: Surgical robot

Search Result 107, Processing Time 0.031 seconds

Development of An Image-Guided Robotic Surgery System for Spinal Fusion (영상 지원 척추 융합 수술 로봇 시스템의 개발)

  • Chung Goo-Bong;Lee Soo-Gang;Kim Sung-Min;Oh Se-Min;Yi Byung-Ju;Kim Young-Soo;Park Jong-Il;Oh Seong-Hoon;Kim Whee-Kuk
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.144-148
    • /
    • 2005
  • The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods fer spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images and intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Several experiments employing the developed robotic surgery system are conducted. The experimental results confirmed that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to his/her respiration.

  • PDF

Static Modeling of a Miniaturized Continuum Robot for Surgical Interventions and Displacement Analysis under Lateral External Loads (중재 시술 적용을 위한 소형 연속체 로봇의 정역학 모델링 및 외부 측면 하중에 의한 변위 분석)

  • Kim, Kiyoung;Woo, Hyunsoo;Cho, Jangho;Shin, Minki;Suh, Jungwook
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.4
    • /
    • pp.301-308
    • /
    • 2020
  • In this paper, we deal with the static modeling of a continuum robot that can perform surgical interventions. The proposed continuum robot is made of stainless steel wires and a multi lumen flexible tube using a thermoplastic elastomer. This continuum robot could be most severely deformed in physical contact with narrow external environments, when a lateral external force acts at the distal tip of the continuum robot. In order to predict the shape and displacement under the lateral external force loading, the forward kinematics, the statics modeling, the force-moment equilibrium equation, and the virtual work-energy method of the continuum robot are described. The deflection displacements were calculated using the virtual work-energy method, and the results were compared with the displacement obtained by the conventional cantilever beam theories. In conclusion, the proposed static modeling and the virtual work-energy method can be used in arrhythmia procedure simulations.

Early experiences with robot-assisted prosthetic breast reconstruction

  • Ahn, Sung Jae;Song, Seung Yong;Park, Hyung Seok;Park, Se Ho;Lew, Dae Hyun;Roh, Tai Suk;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.46 no.1
    • /
    • pp.79-83
    • /
    • 2019
  • Robotic surgery facilitates surgical procedures by employing flexible arms with multiple degrees of freedom and providing high-quality 3-dimensional imaging. Robot-assisted nipple-sparing mastectomy with immediate reconstruction is currently performed to avoid breast scars. Four patients with invasive ductal carcinoma underwent robot-assisted nipple-sparing mastectomy and immediate robot-assisted expander insertion. Through a 6-cm incision along the anterior axillary line, sentinel lymph node biopsy and nipple-sparing mastectomy were performed by oncologic surgeons. The pectoralis major muscle was elevated, an acellular dermal matrix (ADM) sling was created with robotic assistance, and an expander was inserted into the subpectoral, sub-ADM pocket. No patients had major complications such as hematoma, seroma, infection, capsular contracture, or nipple-areolar necrosis. The mean operation time for expander insertion was 1 hour and 20 minutes, and it became shorter with more experience. The first patient completed 2-stage prosthetic reconstruction and was highly satisfied with the unnoticeable scar and symmetric reconstruction. We describe several cases of immediate robot-assisted prosthetic breast reconstruction. This procedure is a feasible surgical option for patients who want to conceal surgical scars.

Study for the Indirect Measuring Method of Operational Force in Surgical Robot Instrument (복강경 수술용 로봇 인스트루먼트의 간접적 작동력 측정법에 관한 연구)

  • Kim, Chi-Yen;Lee, Min-Cheol;Lee, Tae-Kyung;Choi, Seung-Wook;Park, Min-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.9
    • /
    • pp.840-845
    • /
    • 2010
  • This paper proposes the method indirectly measuring the operating force of the end-effect tip of surgical robot instrument which conducts the surgical operation in the body on behalf of the surgeon's hand. Due to the size and safety obligation to the surgical robot instrument, it is difficult to measure the operation force of its tip like grasping force. However the instrument is driven by cable-pulley torque transmission mechanism and when some force is occurred at the tip, then the reaction force appears on the cable as additional tension. Based on this phenomenon, this paper proposes a method to estimate the operating force from measuring reaction force against the driving motor by using a loadcell. And it induces mathematical equation to calculate the force from loadcell by approaching the modulus of elasticity to high order polynomial. And this paper proves the validity of proposed mechanism by experimental test.

Development of Control and HMI for Safe Robot Assisted Minimally Invasive Surgery (최소침습수술용 로봇의 안전성을 위한 제어 및 HMI 개발)

  • Jung, Hoi-Ju;Song, Hyun-Jong;Park, Jang-Woo;Park, Shin-Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.9
    • /
    • pp.1048-1053
    • /
    • 2011
  • Recently, robots have been used in surgical area. Robotic surgery in Minimally Invasive Surgery gives many advantages to surgeons and patients both. This study introduce a robotic assistant to improve the safety of telerobotic Minimally Invasive Surgical procedures. The master-slave system is applied to the telerobotic surgical system with the master arm, which control the system, and slave robot which operates the surgery on the patient body. By using a 3-DOF master arm, the surgeon can control the 6-DOF surgical robot under the constraint of fulcrum point. This paper explains the telerobotic surgical system and confirms the system with the precision of the robot control related to the fulcrum point to enhance the safety.

Evaluation of a Possibility of Estimation of Reaction Force of Surgical Robot Instrument using Sliding Perturbation Observer (슬라이딩 섭동 관측기를 이용한 수술용 로봇 인스트루먼트의 반력 추정 가능성 평가)

  • Yoon, Sung-Min;Lee, Min-Cheol;Kim, Chi-Yen;Kang, Byeong-Ho
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.1
    • /
    • pp.20-28
    • /
    • 2012
  • In spite of the difficulties and uncertain characteristic of cable driven method, surgical robot instrument has adopted it as driving mechanism for various reasons. To overcome the problem of cable system, previous research applied SMCSPO (sliding mode control with sliding perturbation observer) algorithm as robust controller to control the instrument and found that the value of SPO (sliding perturbation observer) followed force disturbance, reaction force loaded on the tip very similarly. Thus, this paper confirms that the perturbation observer is sufficient estimator which finds out the mount of loaded force on the surgical robot instrument. To prove the proposition, simulation using the similar model with an actual instrument and experimental evaluation are performed. The results show that it is possible to substitute SPO for sensors to measure the reaction force. This estimated reaction force will be used to realize haptic function by sending the reaction force to a master device for a surgeon. The results will contribute to create surgical benefit such as shortening the practice time of a surgeon and giving haptic information to surgeon by using it as haptic signal to protect an organ by making force boundary.

Development of Low-inertia Master device for Haptic system configuration of surgical robot (수술용 로봇 햅틱 시스템 구성을 위한 저관성 마스터 장치 핸들부 개발)

  • Kang, Byeong-Ho;Yoon, Sung-Min;Lee, Min Cheol;Kim, Chi-Yen
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.4
    • /
    • pp.267-275
    • /
    • 2012
  • When using commercialized robot assisted laparoscopic, surgeon has met some problems to depend only on image of the surgical field. To solve it, there were various researches. The previous study showed that it is possible to estimate the operation force on the commercialized instrument inside patient without sensors. To apply the estimated force to a haptic master console for the laparoscopy surgical robot system, the light haptic master console should be designed. This paper suggests the design of lighter master console handle to reduce a weight of the console whose structure can match with the joint and DOF of an instrument. A cable-conduit mechanism is designed to make light structure to perform a delicate manipulation. The cable-conduit mechanism removes the weight and inertia of link caused by haptic actuator and encoder which is separated from handle link of a manipulator.

Experimental Evaluation of a Surgical Robot System (ARTHROBOT) for Hip Surgery using Sawbones and Pig Femurs

  • Ko, Seong-Young;Kim, Jonathan;Chung, Jong-Ha;Kwon, Dong-Soo;Lee, Jung-Ju;Yoon, Yong-San;Won, Chung-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.119.3-119
    • /
    • 2002
  • $\textbullet$ A bone-mountable surgical robot system for hip surgery $\textbullet$ A simple gauge-based registration method $\textbullet$ A proposed surgical procedure $\textbullet$ Evaluation method for position/orientation accuracy $\textbullet$ Evaluation method for surface conformity $\textbullet$ The performance evaluation of ARTHROBOT $\textbullet$ Summary

  • PDF

Impedance Model based Bilateral Control for Force reflection of a Laparoscopic Surgery Robot (복강경 수술 로봇의 힘 반향을 위한 임피던스 모델 기반의 양방향 제어)

  • Yoon, Sung-Min;Kim, Won-Jae;Lee, Min-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.801-806
    • /
    • 2014
  • LAS (Laparoscopy Assisted Surgery) has been substituted alternatively for traditional open surgery. However, when using a commercialized robot assisted laparoscopic such as Da Vinci, surgeons have encountered some problems due to having to depend only on information by visual feedback. To solve this problem, a haptic function is required. In order to realize the haptic teleoperation system, a force feedback and bilateral control system are needed. Previous research showed that the perturbation value estimated by a SPO (Sliding Perturbation Observer) followed a reaction force that loaded on the surgical robot instrument. Thus, in this paper, the force feedback problem of surgical robots is solved through the reaction force estimation method. This paper then introduces the possibility of the haptic function realization of a laparoscopic surgery robot using a bilateral control system. For bilateral control, the master uses an impedance control and the slave uses a SMC (Sliding Mode Control). The experiment results show that a torque and force sensorless teleoperation system can be implemented using a bilateral control structure.

Robot-assisted submandibular gland excision via modified facelift incision

  • Jung, Seung Wook;Kim, Young Kwan;Cha, Yong Hoon;Koh, Yoon Woo;Nam, Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.25.1-25.6
    • /
    • 2017
  • Background: The conventional transcervical resection for submandibular gland disease has some risks and an unsatisfactory cosmetic result. Recently, robot-assisted surgery has been developed as a plausible substitute for conventional surgery which provides an excellent cosmetic outcome. Case presentation: The authors performed robot-assisted sialadenectomy via modified facelift incision using the da Vinci Xi surgical system (Intuitive Surgical Inc., CA, USA) with two endowrist arms (monopolar curved scissors and Maryland bipolar forceps) successfully in a 44-year-old female patient who suffered from sialolith and severe atrophic submandibular gland. Conclusions: If similar studies are done in the future, this robot-assisted sialadenectomy may become established as an alternative to existing disadvantageous surgical methods.