DOI QR코드

DOI QR Code

Static Modeling of a Miniaturized Continuum Robot for Surgical Interventions and Displacement Analysis under Lateral External Loads

중재 시술 적용을 위한 소형 연속체 로봇의 정역학 모델링 및 외부 측면 하중에 의한 변위 분석

  • Kim, Kiyoung (Department of Medical Assistant Robotics, KIMM) ;
  • Woo, Hyunsoo (Department of Medical Assistant Robotics, KIMM) ;
  • Cho, Jangho (Department of Medical Assistant Robotics, KIMM) ;
  • Shin, Minki (Department of Medical Assistant Robotics, KIMM) ;
  • Suh, Jungwook (Department of Robot and Smart System Engineering, Kyungpook National University)
  • Received : 2020.08.31
  • Accepted : 2020.11.03
  • Published : 2020.11.30

Abstract

In this paper, we deal with the static modeling of a continuum robot that can perform surgical interventions. The proposed continuum robot is made of stainless steel wires and a multi lumen flexible tube using a thermoplastic elastomer. This continuum robot could be most severely deformed in physical contact with narrow external environments, when a lateral external force acts at the distal tip of the continuum robot. In order to predict the shape and displacement under the lateral external force loading, the forward kinematics, the statics modeling, the force-moment equilibrium equation, and the virtual work-energy method of the continuum robot are described. The deflection displacements were calculated using the virtual work-energy method, and the results were compared with the displacement obtained by the conventional cantilever beam theories. In conclusion, the proposed static modeling and the virtual work-energy method can be used in arrhythmia procedure simulations.

Keywords

References

  1. J. Burgner-Kahrs, D. C. Rucker, and H. Choset, "Continuum robots for medical applications: a survey," IEEE Transactions on Robotics, vol. 31, no. 6, pp. 1261-1280, December, 2015, DOI: 10.1109/TRO.2015.2489500.
  2. H. Jeoung, J. Lee, and N. Kim, "Parameter estimation of a friction model for a tendon-sheath mechanism,"Journal of Korea Robotics Society, vol. 15, no. 2, pp. 190-196, June, 2020, DOI: 10.7746/jkros.2020.15.2.190.
  3. H.-J. Cha and B.-J. Yi, "Design of a new 4-dof soft finger mechanism," Journal of Korea Robotics Society, vol. 3, no. 4, pp. 315-322, December, 2008, [Online], http://www.jkros.org.
  4. G. He, "Motion planning and control for endoscopic operations of continuum manipulators," Intelligent Service Robotics, vol. 12, pp. 159-166, December, 2019, DOI: 10.1007/s11370-018-00269-0.
  5. J. Hwang, J.-Y. Kim, and H. Choi, "A review of magnetic actuation systems and magnetically actuated guidewire-and catheter-based microrobots for vascular interventions," Intelligent Service Robotics, vol. 13, pp. 1-14, January, 2020, DOI: 10.1007/s11370-020-00311-0.
  6. J.-W. Suh and K.-Y. Kim, "Harmonious cable actuation mechanism for soft robot joints using a pair of noncircular pulleys," Journal of Mechanisms and Robotics, vol. 10, no. 6, pp. 061002, December, 2018, DOI: 10.1115/1.4041055.
  7. H.-S. Yoon and B.-J. Yi, "Development of a 4-dof continuum robot using a spring backbone," Journal of Korea Robotics Society, vol. 3, no. 4, pp. 323-330, December, 2008, [Online], http://www.jkros.org.
  8. H. Lee, C. Song, and J. Son, "Hand-controller mechanism and its optimal design method for manually controlled endoscopic surgical instrument," Journal of Korea Robotics Society, vol. 14, no. 3, pp. 203-210, September, 2019, DOI: 10.7746/jkros.2019.14.3.203.
  9. H. Han and D. Y. Lee, "An inextensible wire-shaped deformation model for catheter simulation," Journal of Institute of Control, Robotics and Systems, vol. 22, no. 8, pp. 610-614, 2016, DOI: 10.5302/J.ICROS.2016.16.0119.
  10. J.-W. Suh and K.-Y. Kim, "Design of a discrete bending joint using multiple unit pref joints for isotropic 2-dof motion," International Journal of Control, Automation and Systems, vol. 15, no.1, pp. 64-72, 2017, DOI: 10.1007/s12555-016-0474-z.
  11. Y.-J Kim, S. Cheng, S. Kim, and K. Iagnemma, "A stiffnessadjustable hyper-redundant manipulator using a variable neutral-line mechanism for minimally invasive surgery," IEEE Transactions on Robotics, vol. 30, no. 2, pp. 382-395, April, 2014, DOI: 10.1109/TRO.2013.2287975
  12. R. J. Webster III and B. A. Jones, "Design and kinematic modeling of constant curvature continuum robots: a review," The International Journal of Robotics Research, vol. 29, no. 13 pp. 1661-1683, November, 2010, DOI: 10.1177/0278364910368147.
  13. D. B. Camarillo, C. F. Milne, C. R. Carlson, M. R. Zinn, and J. K. Salisbury, "Mechanics modeling of tendon-driven continuum manipulators," IEEE Transactions on Robotics, vol. 24, no. 6, pp. 1262-1273, December, 2008, DOI: 10.1109/TRO.2008.2002311.
  14. K. Oliver-Butler, J. Till, and C. Rucker, "Continuum robot stiffness under external loads and prescribed tendon displacements," IEEE Transactions on Robotics, vol. 35, no. 2, pp. 403-419, April, 2019, DOI: 10.1109/TRO.2018.2885923.