• Title/Summary/Keyword: Surgical model

Search Result 467, Processing Time 0.035 seconds

Simultaneous resection of synchronous colorectal liver metastasis: Feasibility and development of a prediction model

  • Mufaddal Kazi;Shraddha Patkar;Prerak Patel;Aditya Kunte;Ashwin Desouza;Avanish Saklani;Mahesh Goel
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.1
    • /
    • pp.40-48
    • /
    • 2023
  • Backgrounds/Aims: Timing of resection for synchronous colorectal liver metastasis (CRLM) has been debated for decades. The aim of the present study was to assess the feasibility of simultaneous resection of CRLM in terms of major complications and develop a prediction model for safe resections. Methods: A retrospective single-center study of synchronous, resectable CRLM, operated between 2013 and 2021 was conducted. Upper limit of 95% confidence interval (CI) of major complications (≥ grade IIIA) was set at 40% as the safety threshold. Logistic regression was used to determine predictors of morbidity. Prediction model was internally validated by bootstrap estimates, Harrell's C-index, and correlation of predicted and observed estimates. Results: Ninety-two patients were operated. Of them, 41.3% had rectal cancers. Major hepatectomy (≥ 4 segments) was performed for 25 patients (27.2%). Major complications occurred in 20 patients (21.7%, 95% CI: 13.8%-31.5%). Predictors of complications were the presence of comorbidities and major hepatectomy (area under the ROC curve: 0.692). Unacceptable level of morbidity (≥ 40%) was encountered in patients with comorbidities who underwent major hepatectomy. Conclusions: Simultaneous bowel and CRLM resection appear to be safe. However, caution should be exercised when combining major liver resections with bowel resection in patients with comorbid conditions.

Two-jaw surgery by use of Surgical Jaw Relator (Surgical Jaw Relator를 이용한 양악 수술 치험례)

  • Yang, Sang-Duck
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.238-249
    • /
    • 2005
  • The contemporary two-jaw surgical approach usually involves a Le Fort osteotomy of the maxilla and a ramal osteotomy of the mandible with 3-dimensional repositioning of the jaws as well as the occlusal planes. After making the surgical treatment plan. the surgical movements are duplicated in the model surgery. During this procedure, reference poings and lines are drawn on the base of the models over the dental arch and sawcuts are mads according to these marked osteotomy lines. This technique, however, has been found to be inexact. especially when the laws are moved in several dimensions simultaneously. To overcome this. different methods have been developed for an accurate repositioning of the jaws as planned. A new appliance. Surgical Jaw Relater, has been devised by th8 author for the simple 3-dimensional relocation of the upper and lower models, resulting in the easy construction of the splints such as centric relation splint, intermediate and final splint. This article describes an introduction and a clinical application of this appliance. Through the application of this system to the orthognathic cases including two-law surgery. it is proved that the row device is very clinically useful.

Maxillo-mandibular Contouring Surgery in Monostotic Fibrous Dysplasia Patients using Simulation Surgery

  • Kim, Dong-Young;You, Myoung-Sang;Ah, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.2
    • /
    • pp.60-63
    • /
    • 2016
  • Fibrous dysplasia is quite a rare disease usually involving maxilla and mandible. Because of its benign clinical course, conservative contouring surgery has been recommended for facial deformity. 3D rapid prototype (RP) model gives a lot of informations before operation such as depth of drilling, area of resection and important anatomic structure. The purpose of this study was to report maxilla-mandibular contouring surgery in fibrous dysplasia patients. A total of 14 consecutive patients were included for surgical and esthetic evaluation. Among 14 patients, RP model study was performed in two patients with severe facial deformity. The other patients underwent contouring surgery under conventional methods. Surgical evaluation was performed with computed tomography scan before and after operation. Surgical resection was successful and patients were satisfied with the surgical results.

An Analysis of Cost and Profit of a Nursing Unit using Performance-Based Costing: Case of a General Surgical Ward in a General Hospital (시행기준 원가계산을 적용한 간호단위 원가 및 수익 인식에 관한 연구: 1개 종합병원 일반외과병동 사례를 중심으로)

  • Lim, Ji-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.1
    • /
    • pp.161-171
    • /
    • 2008
  • Purpose: The aim of this study was to analysize net income of a surgical nursing ward in a general hospital. Method: Data collection and analysis was conducted using a performance-based costing and activity-based costing method. Result: Direct nursing activities in the surgical ward were 68, indirect nursing activities were 10. The total cost volume of the surgical ward was calculated at \119,913,334.5. The cost volume of the allocated medical department was \91,588,200.3, and the ward consumed cost was \28,325,134.2. The revenue of the surgical nursing ward was \33,269,925.0. The expense of a surgical nursing ward was \28,325,134.2. Therefore, the net income of a surgical nursing ward was \4,944,790.8. Conclusion: We suggest that to develop a more refined nursing cost calculation model, a standard nursing cost calculation system needs to be developed.

Development of Tissue-Tool Interaction Simulation Algorithms for Rotator Cuff Surgery Scenario in Arthroscopic Surgery Training Simulator

  • Jo, Kyungmin;Bae, Eunkyung;You, Hyeonseok;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.154-164
    • /
    • 2020
  • Various simulator systems for surgery training have been developed and recently become more widely utilized with technology advancement and change in medical education adopting actively simulation-based training. The authors have developed tissue-instrument interaction modeling and graphical simulation algorithms for an arthroscopic surgery training simulator system. In this paper, we propose algorithms for basic surgical techniques, such as cutting, shaving, drilling, grasping, suturing and knot tying for rotator cuff surgery. The proposed method constructs a virtual 3-dimensional model from actual patient data and implements a real-time deformation of the surgical object model through interaction between ten types of arthroscopic surgical tools and a surgical object model. The implementation is based on the Simulation Open Framework Architecture (SOFA, Inria Foundation, France) and custom algorithms were implemented as pulg-in codes. Qualitative review of the developed results by physicians showed both feasibility and limitations of the system for actual use in surgery training.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

An Analysis of Stress Transfer Behaviors within the Necrotic Cancellous Bone following Surgical Procedures or the Management of the Osteonecrosis of the Femoral Head (대퇴골두 무혈성 괴사증의 수술적 기법 적용 후 괴사 망상골 내에서의 응력 변화 해석)

  • Kim, J.S.;Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.245-248
    • /
    • 1997
  • Operative interventions for the management of osteonecrosis of the femoral head (ONFH) include core drilling, with or without vascularized fibular bone grafting. Nevertheless, their clinical results have not been consistently satisfactory. Recently, a new surgical procedure that incorporates cementation with polymethylmethacrylate (PMMA) after core drilling has been tried clinically. In this study, a biomechanical analysis using a finite element method(FEM) was undertaken to evaluate surgical methods and their underlying surgical parameter. Our finite element models included five types. They were (1) normal model (Type I), (2) necrotic model (Type II), (3) core decompressed model (Type III). (4) fibular bone grafted model (Type IV), and (5) cemented with PMMA model (Type V). The geometric dimensions of the femur were based on digitized CT-scan data of a normal person. Various physiological loading conditions and surgical penetration depths by the core were used as mechanical variables to study their biomechanical contributions in stress transfer within the femoral head region. In addition. the peak von Mises stress(PVMS) within the necrotic cancellous bone of the femoral head was obtained. The fibular bone grafted method and cementation method provided optimal stress transfer behaviors. Here. substantial increase in the low stress level was observed when the penetration depth was extended to 0mm and 5mm from the subchondral region. Moreover, significant decrease in PVMS due to surgery was observed in the fibular bone grafted method and the cementation method when the penetration depths were extended up to 0 and 5mm from the subchondral region. The drop in PVMS was greater during toe-off than during heel-strike (57% vs. 28% in Type IV and 49% vs. 22% in Type V). Both the vascularized fibular bone grafting method (Type IV) and the new PMMA technique (Type V) appear to be very effective in providing good stress transfer and reducing the peak Von-Mises stress within the necrotic region. Overall results show that fibular bone grafting and cementation methods are quite similar. In light of above results, the new cementation method appears to be a promising surgical alternative or the treatment of ONFH. The use of PMMA for the core can be less prone to surgical complication as opposed to preparation of fibular bone graft and can achieve more immediate fixation between the core and the surrounding region.

  • PDF

Clinical considerations for successful results in FOS(Functional Orthognathic Surgery): Surgery first orthodontic treatment later (임상가를 위한 특집 1 - 성공적인 선 수술 교정 치료를 위한 고려사항)

  • Oh, Chang-Ok
    • The Journal of the Korean dental association
    • /
    • v.50 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • The fundamental principles and the role of surgeons and orthodontists to produce successful results in orthodontic treatment combined with orthognathic surgery is not different from those of conventional procedures and FOS: surgery-first-orthodontic-treatment-later approach. The communication and cooperation between surgeon and orthodontist is of crucial importance. In FOS, the pre-surgical orthodontic preparation is not carried out in the patient's mouth, but in the mounted stone model and in addition to the simulation of tooth movement, to get a precise surgical occlusion, the entire steps of treatment should be simulated on the articulator as well. Right after the surgery, due to the instability of the occlusion, appropriate post operational care should be given according to the surgical technique applied to the mandible by use of final surgical wafer about 8 weeks.

Development of Korean Teaching Model for Surgical Procedures in Trauma -Essential Surgical Procedures in Trauma Course-

  • Kim, Hohyun;Park, Chan-Yong;Cho, Hyun-Min;Yeo, Kwang-Hee;Kim, Jae Hun;Yu, Byungchul;Go, Seung-Je;Kwon, Oh Sang
    • Journal of Trauma and Injury
    • /
    • v.32 no.1
    • /
    • pp.8-16
    • /
    • 2019
  • Purpose: The Essential Surgical Procedures in Trauma (ESPIT) course was developed as a model to teach necessary surgical procedures to trauma physicians. Its goals are to improve knowledge, self-confidence, and technical competence. Methods: The ESPIT course consisted of five lectures and a porcine lab operative experience. The ESPIT course has been run seven times between February 2014 and April 2016. ESPIT participants completed a questionnaire to assess self-efficacy regarding essential surgical procedures in trauma before and immediately after taking the ESPIT course. Sixty-three participants who completed both pre- and post-course questionnaires on self-efficacy were enrolled in this study. Results: The overall post-ESPIT mean self-efficacy score was higher than the pre-ESPIT mean self-efficacy score ($8.3{\pm}1.30$ and $4.5{\pm}2.13$, respectively) (p<0.001). Self-efficacy was significantly improved after the ESPIT course in general surgeons (p<0.001), thoracic and cardiovascular surgeons (p<0.001), emergency medicine doctors, and others (neurosurgeons, orthopedic surgeons) (p<0.001). The differences in self-efficacy score according to career stage (<1 year, 1-3 years, 3-5 years, and >5 years) were also statistically significant (p<0.001). Conclusions: The data of the ESPIT participants indicated that they felt that the ESPIT course improved their self-efficacy with regard to essential surgical procedures in trauma. The ESPIT course may be an effective strategy for teaching surgical procedures, thus promoting better management of traumatic injuries.

Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons

  • Ju Gang Nam;Whal Lee;Baren Jeong;Eun-Ah Park;Ji Yeon Lim;Yujin Kwak;Hong-Gook Lim
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.706-713
    • /
    • 2021
  • Objective: To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development. Materials and Methods: A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from preoperative electrocardiography-gated CT scans of a 6-month-old patient with TOF with complex pulmonary stenosis. Eleven cardiothoracic surgeons independently evaluated the suitability of four 3D-printed models using composite Tango 27, 40, 50, and 60 in terms of palpation, resistance, extensibility, gap, cut-through ability, and reusability of. Among these, Tango 27 was selected as the final model. Six attendees (two junior cardiothoracic surgery residents, two senior residents, and two clinical fellows) independently performed simulation surgeries three times each. Surgical proficiency was evaluated by an experienced cardiothoracic surgeon on a 1-10 scale for each of the 10 surgical procedures. The times required for each surgical procedure were also measured. Results: In the simulation surgeries, six surgeons required a median of 34.4 (range 32.5-43.5) and 21.4 (17.9-192.7) minutes to apply the ventricular septal defect (VSD) and right ventricular outflow tract (RVOT) patches, respectively, on their first simulation surgery. These times had significantly reduced to 17.3 (16.2-29.5) and 13.6 (10.3-30.0) minutes, respectively, in the third simulation surgery (p = 0.03 and p = 0.01, respectively). The decreases in the median patch appliance time among the six surgeons were 16.2 (range 13.6-17.7) and 8.0 (1.8-170.3) minutes for the VSD and RVOT patches, respectively. Summing the scores for the 10 procedures showed that the attendees scored an average of 28.58 ± 7.89 points on the first simulation surgery and improved their average score to 67.33 ± 15.10 on the third simulation surgery (p = 0.008). Conclusion: Inexperienced cardiothoracic surgeons improved their performance in terms of surgical proficiency and operation time during the experience of three simulation surgeries using a 3D-printed TOF model using Tango 27 composite.