• Title/Summary/Keyword: Surgery Information

Search Result 1,170, Processing Time 0.024 seconds

Analysis of Abdominal Trauma Patients Using National Emergency Department Information System

  • Song, In-Gyu;Lee, Jin Suk;Jung, Sung Won;Park, Jong-Min;Yoon, Han Deok;Rhee, Jung Tak;Kim, Sun Worl;Lim, Borami;Kim, So Ra;Jung, Il-Young
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.116-123
    • /
    • 2016
  • Purpose: To develop an inclusive and sustainable trauma system as the assessment of burden of injuries is very much important. The purpose of this study was to evaluate the estimates and characteristics of abdominal traumatic injuries. Methods: The data were extracted from the National Emergency Department Information System. Based on Korean Standard Classification for Disease 6th version, which is the Korean version of International Classification of Disease 10th revision, abdominal injuries were identified and abdominal surgeries were evaluated with electronic data interchange codes. Demographic factors, numbers of surgeries and clinical outcomes were also investigated. Results: From 2011 to 2014, about 24,696 patients with abdominal trauma were admitted to the hospitals annually in South Korea. The number of patients who were admitted to regional and local emergency medical centers was 8,622 (34.91%) and 15,564(63.02%), respectively. Based on National Emergency Department Information System, liver was identified as the most commonly injured abdominal solid organ (39.50%, 9,754/24,696, followed by spleen (17.57%, 4,338/24,696) and kidney (12.94%, 3,195/24,696). Conclusion: This study shows that the demand for abdominal trauma care is considerable in South Korea and most of the patients with abdominal trauma were admitted to regional or local emergency centers. The results of this study can be used as good source of information for staffs to ensure proper delivery of abdominal trauma care in trauma centers nationally.

Why most patients do not exhibit obstructive sleep apnea after mandibular setback surgery?

  • Kim, Jin-Wook;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.7.1-7.8
    • /
    • 2020
  • Maxillomandibular advancement (MMA) is effective for the treatment of obstructive sleep apnea (OSA). In previous studies, the airway was increased in the anteroposterior and transverse dimensions after MMA. However, the effect of the opposite of mandibular movement (mandibular setback) on the airway is still controversial. Mandibular setback surgery has been suggested to be one of the risk factors in the development of sleep apnea. Previous studies have found that mandibular setback surgery could reduce the total airway volume and posterior airway space significantly in both the one-jaw and two-jaw surgery groups. However, a direct cause-and-effect relationship between the mandibular setback and development of sleep apnea has not been clearly established. Moreover, there are only a few reported cases of postoperative OSA development after mandibular setback surgery. These findings may be attributed to a fundamental difference in demographic variables such as age, sex, and body mass index (BMI) between patients with mandibular prognathism and patients with OSA. Another possibility is that the site of obstruction or pattern of obstruction may be different between the awake and sleep status in patients with OSA and mandibular prognathism. In a case-controlled study, information including the BMI and other presurgical conditions potentially related to OSA should be considered when evaluating the airway. In conclusion, the preoperative evaluation and management of co-morbid conditions would be essential for the prevention of OSA after mandibular setback surgery despite its low incidence.

Similar Operative Outcomes between the da Vinci Xi® and da Vinci Si® Systems in Robotic Gastrectomy for Gastric Cancer

  • Alhossaini, Rana M.;Altamran, Abdulaziz A.;Choi, Seohee;Roh, Chul-Kyu;Seo, Won Jun;Cho, Minah;Son, Taeil;Kim, Hyung-Il;Hyung, Woo Jin
    • Journal of Gastric Cancer
    • /
    • v.19 no.2
    • /
    • pp.165-172
    • /
    • 2019
  • Purpose: The robotic system for surgery was introduced to gastric cancer surgery in the early 2000s to overcome the shortcomings of laparoscopic surgery. The more recently introduced da Vinci $Xi^{(R)}$ system offers benefits allowing four-quadrant access, greater range of motion, and easier docking through an overhead boom rotation with laser targeting. We aimed to identify whether the $Xi^{(R)}$ system provides actual advantages over the $Si^{(R)}$ system in gastrectomy for gastric cancer by comparing the operative outcomes. Materials and Methods: We retrospectively reviewed all patients who underwent robotic gastrectomy as treatment for gastric cancer from March 2016 to March 2017. Patients' demographic data, perioperative information, and operative and pathological outcomes were collected and analyzed. Results: A total of 109 patients were included in the $Xi^{(R)}$ group and 179 in the $Si^{(R)}$ group. Demographic characteristics were similar in both groups. The mean operative time was 229.9 minutes in the $Xi^{(R)}$ group and 223.7 minutes in the $Si^{(R)}$ group. The mean estimated blood loss was 72.7 mL in the $Xi^{(R)}$ group and 62.1 mL in the $Si^{(R)}$ group. No patient in the $Xi^{(R)}$ group was converted to open or laparoscopy, while 3 patients in the $Si^{(R)}$ group were converted, 2 to open surgery and 1 to laparoscopy, this difference was not statistically significant. Bowel function was resumed 3 days after surgery, while soft diet was initiated 4 days after surgery. Conclusions: We found no difference in surgical outcomes after robotic gastrectomy for gastric cancer between the da Vinci $Xi^{(R)}$ and da Vinci $Si^{(R)}$ procedures.

Carpal Bone Segmentation Using Modified Multi-Seed Based Region Growing

  • Choi, Kyung-Min;Kim, Sung-Min;Kim, Young-Soo;Kim, In-Young;Kim, Sun-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.332-337
    • /
    • 2007
  • In the early twenty-first century, minimally invasive surgery is the mainstay of various kinds of surgical fields. Surgeons gave percutaneously surgical treatment of the screw directly using a fluoroscopic view in the past. The latest date, they began to operate the fractured carpal bone surgery using Computerized Tomography (CT). Carpal bones composed of wrist joint consist of eight small bones which have hexahedron and sponge shape. Because of these shape, it is difficult to grasp the shape of carpal bones using only CT image data. Although several image segmentation studies have been conducted with carpal bone CT image data, more studies about carpal bone using CT data are still required. Especially, to apply the software implemented from the studies to clinical fIeld, the outcomes should be user friendly and very accurate. To satisfy those conditions, we propose modified multi-seed region growing segmentation method which uses simple threshold and the canny edge detector for finding edge information more accurately. This method is able to use very easily and gives us high accuracy and high speed for extracting the edge information of carpal bones. Especially, using multi-seed points, multi-bone objects of the carpal bone are extracted simultaneously.

Recovery Outcomes Following Laparoscopic Surgery in Overweight Rectal Cancer Patients (과체중 직장암 환자의 복강경 수술 회복성과)

  • Woo, Sang Jun;Lee, Eun Sook;Kim, Hyeong Rok
    • Journal of Korean Clinical Nursing Research
    • /
    • v.15 no.3
    • /
    • pp.17-26
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the recovery outcomes between a normal weight group (BMI<25) and an overweight group ($$BMI{\geq_-}25$$), who received laparoscopic surgery for rectal cancer, to provide information for effective decision making. Methods: Data from 76 patients who received laparoscopic surgery for rectal cancer in a university hospital were reviewed retrospectively from September 2004 to March 2007. Collected data were analyzed using Win SPSS 12.0. The recovery outcomes related to the operation were the length of the operation, the amount of bleeding during the operation, the length of stay in the recovery room, first bowel movement, the length of hospital stay, and complications. Results: There was no statistical difference between the two groups with regard to the recovery outcomes. Conclusion: From the above results, nursing information can be offered to help make effective decisions before the operation for overweight patients with rectal cancer who prefer laparoscopic surgery.

Complications associated with orthognathic surgery

  • Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.1
    • /
    • pp.3-15
    • /
    • 2017
  • While most patients undergo orthognathic surgery for aesthetic purposes, aesthetic improvements are most often followed by postoperative functional complications. Therefore, patients must carefully decide whether their purpose of undergoing orthognathic surgery lies on the aesthetic side or the functional side. There is a wide variety of complications associated with orthognathic surgery. There should be a clear distinction between malpractice and complications. Complications can be resolved without any serious problems if the cause is detected early and adequate treatment provided. Oral and maxillofacial surgeons must have a full understanding of the types, causes, and treatment of complications, and should deliver this information to patients who develop these complications.

Judgement in artificial eruption of embedded teeth from an oral surgery perspective: review article

  • Mahardawi, Basel;Kumar, KC;Arunakul, Kanin;Chaiyasamut, Teeranut;Wongsirichat, Natthamet
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.1
    • /
    • pp.12-18
    • /
    • 2020
  • Impacted teeth are a frequent phenomenon encountered by every clinician. The artificial eruption of embedded teeth is the process of directing an impacted tooth into normal occlusion. This procedure is currently attracting attention, with the aim of finding the best technique to use according to each case. This article presents key information regarding impacted incisors, canines, and premolars. In addition, we describe the most common techniques to use for artificial eruption, the open and closed techniques. We review the literature concerning these techniques and outline how clinicians can manage every type of impacted tooth.

Fluorescence Image-Based Evaluation of Gastric Tube Perfusion during Esophagogastrostomy

  • Quan, Yu Hua;Han, Kook Nam;Kim, Hyun Koo
    • Journal of Chest Surgery
    • /
    • v.53 no.4
    • /
    • pp.178-183
    • /
    • 2020
  • During esophagectomy and esophagogastrostomy, the prediction of anastomotic leakage relies on the operating surgeon's tactile or visual diagnosis. Therefore, anastomotic leaks are relatively unpredictable, and new intraoperative evaluation methods or tools are essential. A fluorescence imaging system enables visualization over a wide region of interest, and provides intuitive information on perfusion intraoperatively. Surgeons can choose the best anastomotic site of the gastric tube based on fluorescence images in real time during surgery. This technology provides better surgical outcomes when used with an optimal injection dose and timing of indocyanine green.

Resuscitative Endovascular Balloon Occlusion of the Aorta for an Iliac Artery Aneurysm: Case Report

  • Chang, Sung Wook;Chun, Sangwook;Lee, Gyeongho;Seo, Pil Won
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.429-432
    • /
    • 2021
  • Isolated iliac artery aneurysm (IAA) is rare, but can be fatal. Emergency surgery is performed in cases of hemorrhagic shock due to a suddenly ruptured IAA, which may have a high mortality rate because of massive non-compressible torso hemorrhage (NCTH). Recently, resuscitative endovascular balloon occlusion of the aorta (REBOA) has been accepted as an alternative to aortic cross-clamping via open thoracotomy to achieve hemostasis in trauma patients with profound shock due to NCTH and is considered an emerging bridging therapy for damage control. However, there is limited information on the use of REBOA in non-trauma patients with shock. Herein, we describe a patient with impending cardiac arrest due to isolated ruptured IAA, in whom perioperative bleeding was successfully controlled by REBOA.

3D Simulation of Dental Implant Surgery Using Surgical Guide Stents (식립 보조도구를 이용한 3D 치아 임플란트 시술 시뮬레이션)

  • Park, Hyung-Wook;Kim, Myong-Soo;Park, Hyung-Jun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.3
    • /
    • pp.216-226
    • /
    • 2011
  • Surgeon dentists usually rely on their experiential judgments from patients' oral plaster casts and medical images to determine the positional and directional information of implant fixtures and to perform drilling tasks during dental implant surgical operations. This approach, however, may cause some errors and deteriorate the quality of dental implants. Computer-aided methods have been introduced as supportive tools to alleviate the shortcomings of the conventional approach. In this paper, we present an approach of 3D dental implant simulation which can provide the realistic and immersive experience of dental implant information. The dental implant information is primarily composed of several kinds of 3D mesh models obtained as follows. Firstly, we construct 3D mesh models of jawbones, teeth and nerve curves from the patient's dental images using software $Mimics^{TM}$. Secondly, we construct 3D mesh models of gingival regions from the patient's oral impression using a reverse engineering technique. Thirdly, we select suitable types of implant fixtures from fixture database and determine the positions and directions of the fixtures by using the 3D mesh models and the dental images with software $Simplant^{TM}$. Fourthly, from the geometric and/or directional information of the jawbones, the gingival regions, the teeth and the fixtures, we construct the 3D models of surgical guide stents which are crucial to perform the drilling operations with ease and accuracy. In the application phase, the dental implant information is combined with the tangible interface device to accomplish 3D dental implant simulation. The user can see and touch the 3D models related with dental implant surgery. Furthermore, the user can experience drilling paths to make holes where fixtures are implanted. A preliminary user study shows that the presented approach can be used to provide dental students with good educational contents. With future work, we expect that it can be utilized for clinical studies of dental implant surgery.