저압 수용가 설비에서 누전차단기와 서지방호장치 사이의 보호협조 (Protection coordination between residual current device and surge protective devices in low-voltage consumer's installations)

  • 이복희;김회구;박희열;안창환
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.75-81
    • /
    • 2013
  • In this paper, protection coordination between residual current devices and surge protective devices in low-voltage consumer's distribution systems are presented. In the case that a surge protrctive device(SPD) is located on the load side of an residual current device(RCD), when the surge is injected from the source side of the RCD, most of injected surge currents are split into the RCD and the protection coordination between the SPD and RCD is improper, three of 6 specimens experience unintended operation due to test impulse currents. Also when the surges is injected from the load side, a lot of the surge currents is split into the SPD, but a half of test specimens causes nuisance trip. Coordination between SPD and RCD is not valid. When installing SPD, it is important to select SPD after due consideration of the protection voltage level of metal oxide varistor embedded in RCD. It is expected that the results obtained from this work could be useful to improve the protection effects of SPD in low-voltage distribution systems.

저압용 서지 보호 장치(SPD)의 보호 거리 해석 (Analysis of the Protective Distance of Low-Voltage Surge Protective Device(SPD) to Equipment)

  • 이정우;오용택
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.28-34
    • /
    • 2012
  • Installing surge protection devices for a low-voltage system is important to ensure the survival of electric or electronic devices and systems. If surge protection devices (SPD) are installed without consideration of the concept of lightning protection zones, the equipment to be protected might be damaged despite the correct energy coordination of SPDs. This damage is induced by the reflection phenomena on the cable connecting an external SPD and the load protected. These reflection phenomena depend on the characteristics of the output of the external SPD, the input of the loads, and the cables between the load and the external SPD. Therefore, the SPD has an effective protection distance under the condition of the specific load and the specific voltage protection level of SPD. In this paper, PSCAD/EMTDC software is used to simulate the residual voltage characteristics of SPD Entering the low-voltage device. And by applying a certain voltage level, the effective protection distances of SPD were analyzed according to the each load and length of connecting cable, and the effectiveness of SPD were verified.

저압용 SPD가 설치된 전력선통신에서 데이터전송 성능 향상 (A Method for Enhancing Data Transmission Performance in the Power-Line Communication Channel with Low-Voltage Surge Protective Devices)

  • 최종민;전태현
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.78-85
    • /
    • 2012
  • Low-Voltage power lines should equip surge protection devices which protect electronic equipments and human lives against lightning and abnormal voltages. Data transmission capacity of the power line is determined by frequency characteristics of the surge protective devices. To analyze the effects of surge protective devices on the data transmission performance, various combinations of installation methods are tested which include ZnO varistor elements that is compatible with class I, class II and class III. The result claims that ZnO varistor for class III is found to be one of the main factors that deteriorates the transmission performance. To overcome this problem a serial connection methed between Gap type SPD and ZnO varistor is proposed. With the proposed scheme, laboratory experimental results show that the data transmission performance can be improved up to 91.9[%] with proper SPD combination.

A Study on the Performance Analysis of Photovoltaic System with Digital Surge Detection device

  • Byeong-Ho Jeong;Ju-Hoon Park
    • International journal of advanced smart convergence
    • /
    • 제13권3호
    • /
    • pp.376-387
    • /
    • 2024
  • This paper examines the performance improvement of a photovoltaic power generation system with a surge protection function by applying a digital surge detection device for surge suppression in a direct current distribution panel applied to a photovoltaic power generation system. The main components used for surge protection are mainly SAD, MOV, and GTA components, and a digital surge detection device was additionally applied to this. Each component has advantages and disadvantages in terms of performance and functionality for surge protection, so a surge protection device with meaningful performance and functionality must be designed in a complex device structure that harmonizes the advantages and disadvantages of each component in order to construct a surge protection device with meaningful performance and function. Through empirical experiments, a performance analysis of a complex surge detection device to which a digital surge detection device is applied was conducted. As a result of the experiment, through absorption and blocking of surges detected through a digital surge detection device, it has both absorption and blocking performance for surges and exhibits surge absorption characteristics for hundreds of voltages in micro second. This performance showed a relatively stable state against surge noise compared to conventional devices, which produced an output waveform of stable quality in the inverter output waveform.

바리스터와 LC필터를 사용한 2단 서지보호장치 (Two-Stage Surge Protection Device with Varistor and LC Filter.)

  • 이복희;김지훈;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.279-281
    • /
    • 1996
  • This paper deals with the two stage surge protection device by using varistor and LC low pass filter. Recently varistor alone has been used with overvoltage protection devices for the AC power mains and has same problems associated with high remnant voltage and noise. In this work, in order to improve the cutoff performance of surge protection device, the lightning surge protection device having two stage hybrid circuit for an AC single phase mains was designed and fabricated. Operation characteristics and surge clamping performance of the surge protection device in an $8/20{\mu}s$ surge current are investigated. As a consequence, it is found that the proposed two stage surge protective device for AC power mains has a variety of advantages such as a smaller clamping voltage, high frequency noise reduction and large clamping capacity.

  • PDF

종속 접속된 전압제한형 서지방호장치의 에너지협조 (Energy Coordination of Cascaded Voltage Limiting Type Surge Protective Devices)

  • 이복희;신희경
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.29-35
    • /
    • 2013
  • For the purpose of designing and applying optimum surge protection, one of the essential points is to take into account the energy coordination between cascaded surge protective devices(SPDs) and it is important to obtain an acceptable sharing of the energy stress between two cascaded SPDs. In this paper, in case of two voltage-limiting SPDs connected in parallel, the amount of splitting impulse current and energy that flow through each SPDs is investigated as a function of the protective distance. As a result, the energetic coordination between cascaded SPDs is strongly dependent on the voltage protection level of SPDs and the protective distance. It was confirmed that the sharing of the energy between two cascaded SPDs and the limited voltage levels are appropriate when the voltage protection levels of both upstream and downstream SPDs are the same.

낙뢰 Surge 방호를 위한, 독립접지를 공통접지로 개선하는 효율적인 방법에 대한 연구 (A Study on the Effective Surge Protection Method from Induced Lightning Surge to Improve Isolate Grounding to Common Grounding)

  • 우제욱
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2013년도 추계학술대회
    • /
    • pp.215-218
    • /
    • 2013
  • 본 논문은 낙뢰 Surge 방호를 위하여 독립접지를 공통접지로 개선하는 효율적인 방법을 제안하였다. 낙뢰 Surge 방호를 위해서는 등전위 이론에 근거하는 공통접지방식이 적합하고, 중성선이 있는 전원계통에서는 공통접지방식을 사용하는 것이 국제적으로 통용되는 기술규격이다. 따라서 낙뢰 Surge에 취약한 문제점을 갖고 있는 기존의 중성선이 없는 전원계통의 독립접지방식을 중성선이 있는 전원계통의 공통접지방식으로 개선을 하고, 정전압소자를 이용하여 낙뢰 Surge를 방호하는 효율적인 등전위 시스템 구축 방법을 제안한다.

  • PDF

낙뢰 Surge 방호를 위한, 독립접지를 공통접지로 개선하는 효율적인 방법에 대한 연구 (A Study on the Effective Surge Protection Method from Induced Lightning Surgeto Improve Isolate Grounding to Common Grounding)

  • 전형구;우제욱;서용준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1459-1467
    • /
    • 2011
  • 본 논문은 낙뢰 Surge 방호를 위하여 독립접지를 공통접지로 개선하는 효율적인 방법을 제안하였다. 낙뢰 Surge 방호를 위해서는 등전위 이론에 근거하는 공통접지방식이 적합하고, 중성선이 있는 전원계통에서는 공통접지방식을 사용하는 것이 국제적으로 통용되는 기술규격이다. 따라서 낙뢰 Surge에 취약한 문제점을 갖고 있는 기존의 중성선이 없는 전원계통과 독립접지방식을 중성선이 있는 전원계통과 공통접지방식으로 개선을 하고, 정전압소자를 이용하여 낙뢰 Surge를 방호하는 효율적인 등전위 시스템 구축 방법을 제안한다.

  • PDF

뇌서지 전류에 대한 산화아연바리스터의 Pspice 시뮬레이션 모델 (Pspice Simulation Model of a ZnO Varistor for Lightning Surge Current)

  • 이복희;공영훈;이경옥;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1675-1677
    • /
    • 1998
  • It is currently increasing to use surge protection devices in the protection of various electronic circuits from the transient overvoltages such as lightning strikes and switching surges. For this reason, the simulation methods, which can easily predict the protection performance of the devices, are strongly required in order to design the adequate surge protection circuits in lightning surge cut-off performance and economic aspects. This paper deals with ZnO varistor modeling method for designing a surge protection circuit and suggests the Pspice simulation model which takes the characteristic of varying clamping voltage into consideration during the time-to-crest, in range of $8{\sim}30{\mu}s$, of surge current applied to a ZnO varistor. The ZnO varistor Pspice simulation data introduced in this paper has produced almost same values as the measured results experimentally.

  • PDF

Characteristics of Lightning Overvoltages Coming in Low-Voltage Power Distribution Systems

  • Lee, Bok-Hee;Lee, Dong-Moon;Lee, Su-Bong;Jeong, Dong-Cheol;Lee, Jae-Bok;Myung, Sung-Ho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권3호
    • /
    • pp.91-98
    • /
    • 2003
  • The importance of improving the quality of electric power is being strongly raised, owing to an increasing use of sensitive and small-sized electronic devices and systems. The transient over-voltages on low-voltage power distribution systems are induced by direct or indirect lightning return strokes. These can cause damage and/or malfunction of the utility systems for home automation, office automation, factory automation, medical automation, etc. The behaviors of lightning overvoltages transferred through the transformer to the low-voltage distribution systems using a Marx generator were experimentally investigated. Furthermore, the coupling mechanisms of lightning overvoltages transferred to the low-voltage systems were clearly illustrated through a theoretical simulation using a Pspice program. The overvoltages in low-voltage ac power systems are rarely limited by the application of the surge arrester to the primary side of the distribution transformer. A superior surge protection scheme is to install surge protection devices at the service entrance switchboard and/or at the load devices in TN power systems.