• Title/Summary/Keyword: Surge Simulator System

Search Result 9, Processing Time 0.031 seconds

A Study on Development of Lightning and Surge Protection System for Electrical Fire Prevention (전기화재 예방을 위한 낙뢰 및 써지 보호시스템 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.27-32
    • /
    • 2006
  • The occurrence frequency of lightning and surge from the weather accident is increasing recently, which the damage scale have been enlarged every year. A protection system development to solve these problems have been risen to a multinational concern field. In this paper, a novel protection system is proposed to restrain lightning and various surges which happen in electricity and communication equipment. The proposed protection system is designed to the structure to restrain the rise of the earth potential which is become to the problem of conventional protection system. The secondary damage as a result does not happen. The practicality of the developed surge protection system is proved through various accident occurrence simulator.

  • PDF

Effects of Lightning Surges on the Life of ZnO Varistors (뇌서지가 ZnO바리스터에 미치는 영향)

  • Lee, Bong;Lee, Su-Bong;Kang, Sung-Man;Lee, Bok-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.257-262
    • /
    • 2006
  • To evaluate the change in protective levels of zinc oxide (ZnO) varistors after the surge absorption, this paper investigated the effects of the number of injection and amplitude of lightning surges on the life of ZnO varistors for low voltages. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages were measured. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of 5 $[kA_p]$ was used. The ZnO varistor leakage current increases with exposure to impulse current, and the number of injection of $8/20{\mu}s$ impulse currents to breakdown was inversely proportional to the amplitude of the test current. Behaviors of ZnO varistor leakage currents were strongly dependent on the number of injection and amplitude of $8/20{\mu}s$ impulse currents. ZnO varistors degrade gradually when subjected to impulse current, and the resistive leakage current flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages was significantly increased after a certain number of injection that is dependent on the amplitude of the test impulse current. As a result, the life of ZnO varistors mainly depends on the amplitude and occurrence frequency of lightning surges.

Optimization of the Earthing Resistance and Research on the Electrical Characteristics of New Catalyst for the Quality Earthing (접지품질 개선을 위한 접지저항 최적화 및 접지충진제의 전기적 특성 연구)

  • Park, C.G.;Ahn, S.J.;Woo, J.W.;Ahn, S.J.;Yu, Y.J.;Ahn, S.J.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1078-1085
    • /
    • 2006
  • In earthing technologies, the intrusion of the surge wave can be protected when the earthing resistance is as low as several ohms. However, the cost fer realizing such a low resistance is quite high. Therefore it is important to determine appropriate target value of the earthing resistance to install cost-effective grounding system. In this work, we have proposed an optimization method of the earthing resistance according to the various environmental parameters by using a numerical simulator We have also developed new catalyst composed of water-soluble alkaline elements and activated carbon and investigated its electrical characteristics for enhancement of the earthing qualities.

  • PDF

Characteristics of leakage currents flowing through ZnO varistor exposed to surge currents (서지전류가 입사된 ZnO 바리스터에 흐르는 누설전류의 특성)

  • Lee, Bok-Hee;Li, Feng;Lee, Su-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.338-341
    • /
    • 2006
  • This paper presents the leakage current characteristics of ZnO varistors exposed to the $8/20{\mu}s$ lightning impulse currents as functions of the number of injection and amplitude of impulse currents. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of $5[kA_p]$ was used. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents were measured under 60 Hz AC voltages. The trend curves of resistive leakage current of ZnO varistors were analytically calculated.

  • PDF

A Research on the Design and Implementation of LED Display-based Light Gun Systems

  • Byong-Kwon Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.5
    • /
    • pp.85-91
    • /
    • 2024
  • With the current surge in leisure sports activities involving firearms and the costly shooting practices in the military, there's a growing interest in using virtual reality as a cost-effective alternative. This study proposes a system that addresses the drawbacks of existing shooting practice setups, such as dim spaces and high installation costs, by making it feasible on large display screens. The system integrates IR receivers and guns for practice, ensuring usability and efficiency through an application. Additionally, an accuracy adjustment feature enhances precise coordination recognition. As a result, this cyber light gun system offers an affordable solution for outdoor training.

A Study on the Malfunction Prevention for Transponder of Record Type Fire Alarm System (R형 자탐설비의 중계기 오동작 방지 대책에 대한 연구)

  • Yoo, Jae Ick;Jung, Jae Hee
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.54-59
    • /
    • 2014
  • The record type receivers that are operated in large industrial sites have strength in preventing fire. However, because of its long circuit lines and multiple detectors, the receivers are vulnerable to lightning, noise, and breakdown of equipments, resulting in malfunction. In case of malfunctioning of detection circuits of main protection areas, such as electrical room and server room, potential release of gaseous extinguisher agents may lead to property and life damage. In this paper, we present the results on the characteristics of the transponder that initiates the solenoid valves, with respect to various electromagnetic and lightning inflow conditions. Based on the measured data, we analyzed the systematic problems of the transponder. In order to prevent receiver malfunctions, a sequential circuit was configured with two additional transponders and a timer. The circuit was tested with a simulator with preference and delay circuit algorithms.

Efficient Resource Allocation Technique for LTE-Advanced based Interference Avoidance of Heterogeneous Network (LTE-Advanced 기반 이기종 네트워크 시스템의 간섭회피를 위한 효율적인 자원할당 기법)

  • Jang, Sung-Won;Seong, Hyeon-Kyeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.1
    • /
    • pp.46-52
    • /
    • 2016
  • LTE-Advanced system consisting of the number of cells in the cellular environment because it is built to allow efficient use of limited frequency resources of adjacent cell interference avoidance should be considered. Transition services in accordance with the development of the mobile communication technology, wireless multimedia content from voice-centric mobile communications services and causing a lot of mobile data traffic, such as smart phones and tablet terminals spread of a data-driven surge in mobile data traffic base stations in urban areas by increasing became a reality that can not be prevented. In this paper, we propose a new Hybrid resource allocation technique for improving the performance of the cell boundary and analyzed the performance of the proposed new techniques to perform the simulation using LTE-Advanced system level simulator based on 19cell of cellular system model.

A Study on Implementation of Indoor Positioning Simulator through Indoor Positioning API Development (실내측위 API개발을 통한 실내측위 시뮬레이터 구현에 관한 연구)

  • Shin, Chang Soo;Kim, Sung Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.873-881
    • /
    • 2023
  • The evolution of civil engineering technology, exemplified by recent milestones like the completion of the Gangnam Global Business Center (GBC), has fostered the construction of expansive civil and architectural structures both above and below the earth's surface. This surge in construction necessitates a commensurate advancement in research and technology pertaining to safety protocols applicable to these vast edifices. Such protocols encompass a spectrum of concerns, ranging from the preemptive mitigation of accidents to the effective management of exigencies such as fires. As the trajectory of construction endeavors continues unabated, encompassing both subterranean and elevated domains, a concomitant imperative emerges to refine the methodologies underpinning precise indoor positioning. To address this need, an innovative web-based simulator has been devised to emulate indoor positioning scenarios for rigorous testing. This research further entails the development of an indoor positioning data Application Programming Interface (API) fortified by Geographic Information System (GIS) spatial operation techniques. This API is anchored in the construction of intricate test data, centered on the spatial layout of building 13 at the Electronics and Telecommunications Research Institute (ETRI). Consequently, the study renders feasible the expeditious provisioning of diverse signal-based and image-based spatial information, pivotal for enhancing the navigational acumen of mobile devices. Path delineation, cellular signal mapping, landmark identification, and ancillary navigational aids are among the manifold datasets promptly furnished by the indoor positioning data API. In summation, this study engenders a crucial leap towards the fortification of safety protocols and navigational precision within the expansive confines of modern architectural wonders.

Effects of the Injected Number and Amplitude of 8/20 [μs] Impulse Current on the Life of ZnO Varistors (8/20 [μs] 임펄스전류의 인가횟수와 크기가 ZnO바리스터의 수명에 미치는 영향)

  • Lee, Bok-Hee;Li, Feng
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.118-124
    • /
    • 2007
  • This paper presents the effects of the injected number and amplitude of impulse current on the service life of ZnO varistors for low voltages. To analyze the effects of lightning impulse currents on the performance of ZnO varistors, the measurements of resistive leakage current and power dissipation at the power frequency ac voltage before and after the injections of the $8/20[{\mu}s]$ impulse currents were made. As a consequence, the duration and amplitude of resistive leakage current flowing through ZnO varistor were increased with increasing the number of injections of the $8/20[{\mu}s]$ impulse currents. It is desirable that the service life of ZnO varistors should be evaluated as a function of the number and amplitude of lightning impulse current.