• 제목/요약/키워드: Surge Line

검색결과 259건 처리시간 0.03초

지중배전계통에서의 분기선로의 서지특성 해석 (Analysis of Surge behavior on Branch Line in the Underground Distribution Systems)

  • 이장근;이종범;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.157-158
    • /
    • 2006
  • This paper describes the overvoltage of branch line in underground distribution systems when the direct lightning surge strikes on conductor of overhead line. Distribution systems are very complex because that includes so many branch lines, transformers, switches and so on. Therefor model systems consist of overhead distribution lines, underground cable include branch lines, lightning source and switches. Those are established by EMTP/ATPDraw. Simulation analyzes surge behavior on branch lines considering various conditions in underground distribution systems. Simulation results shoe overvoltage with location in various cases.

  • PDF

송전선로 피뢰기 적용 및 외부 갭형과 갭레스형의 동작특성 비교 (Comparison on Characteristics between air-gap type and gapless In transmission LA)

  • 유희영;김종채;김병헌;박윤석;이봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.347-348
    • /
    • 2008
  • This paper presents the use of Line Surge Arresters on 154kV double circuit lines. The ouatge rate which is highly related to the tower footing resistance is showed during the last a few year. The general methods that have been adopted at lines also are introduced. Lightning performance of lines without and with line surge arrester is studied and compared. The characteristics between air-gap type and gapless type LSA also compared. Line surge arrester installation strategy is presented.

  • PDF

가압기밀림관의 수평배관내 열성층유동 (Thermal stratification in a horizontal pipe of pressurizer surge line)

  • 정일석;김유;염학기;박만흥
    • 대한기계학회논문집B
    • /
    • 제20권4호
    • /
    • pp.1449-1457
    • /
    • 1996
  • In this paper, the unsteady two dimensional model for the thermal stratification in the pressurizer surge line of PWR plant has been proposed to numerically investigate the heat transfer and flow characteristics. The dimensionless governing equations are solved by using the Control Volume Formulation and SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm. The temperature profile of fluids and pipe wall with time are shown when the thermal stratification occurs in the horizontal pipe. The numerical result shows that the maximum dimensionless temperature difference is about O.514 between hot and cold section of pipe wall at dimensionless time 1,632.

765 KV 2 회선(回線) 송전선(送電線) 절연협조(絶緣協助) (Insulation coordination of 765 KV double circuit transmission line)

  • 김정부;민석원;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.774-777
    • /
    • 1988
  • This paper covers the insulation coordination of 765 KV transmission line in Korea Electric Power Corporation. The design for the lightning, switching surge, and contamination was conducted to increase the reliability of 765 KV line. The authors have used the result of a limited Westinghouse ANACOM swiching surge study of the Korea Electric Corporation's 765 KV Expansion plan. The study investigated the switching surge overvoltage distribution and maximum switching overvoltage when relosing 765 KV lines. They used the technical data of the suspension insulator for the contamination design, which was available from a foreign insulator manufacture. From this paper, the authors find out that the contamination design dominates to determine the number of insulator and the SOV design dominates the air clearance in the tower. Afterwards the authors will confirm this design by Demonstration Test with Korea Electro-technology Research Institute.

  • PDF

배전선로의 유도뢰 해석 (Analysis on Overvoltage induced on Power Distribution line by Lightning surge)

  • 김헌준;최상열;정호성;신명철;박남옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.279-281
    • /
    • 1998
  • This paper present overvoltage induced on distribution power line by lightning surge. It is important problem that overvoltage threatens credit and security of the power system. In this paper induced overvoltage was calculated. From the line being modeled in really actual practice. Also, the proper suppressing effects of a surge arrester against lightning induced voltages were suggested.

  • PDF

설계초과지진시 CPE를 고려한 밀림관 파단전누설 평가 (Leak Before Break Evaluation of Surge Line by Considering CPE under Beyond Design Basis Earthquake)

  • 김승현;김연정;이한걸;강선예
    • 한국압력기기공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.19-25
    • /
    • 2022
  • Nuclear Power Plants (NPP) should be designed to have sufficient safety margins and to ensure seismic safety against earthquake that may occur during the plant life time. After the 9.12 Gyeongju earthquake accident, the structural integrity of nuclear power plants due to the beyond design basis earthquake is one of key safety issues. Accordingly, it is necessary to conduct structural integrity evaluations for domestic NPPs under beyond design basis earthquake. In this study, the Level 3 LBB (Leak Before Break) evaluation was performed by considering the beyond design basis earthquake for the surge line of a OPR1000 plant of which design basis earthquake was set to be 0.2g. The beyond design basis earthquake corresponding to peak ground acceleration 0.4g at the maximum stress point of the surge line was considered. It was confirmed that the moment behaviors of the hot leg and pressurized surge nozzle were lower than the maximum allowable loading in moment-rotation curve. It was also confirmed that the LBB margin could be secured by comparing the LBB margin through the Level 2 method. It was judged that the margin was secured by reducing the load generated through the compliance of the pipe.

서지 마진 증가를 고려한 원심 압축기 설계 최적화 (A Study on Centrifugal Compressor Design Optimization for Increasing Surge Margin)

  • 최재호
    • 한국유체기계학회 논문집
    • /
    • 제11권2호
    • /
    • pp.38-45
    • /
    • 2008
  • This study presents a numerical procedure to optimize the compressor design to increase the surge margin of compressor with response surface method (RSM). The Box-Behnken design method is used to reduce the number of calculation for fitting the second-order response surface. In order to consider the increase of surge margin during numerical optimization without any calculation at the surge point, the slope of compressor characteristic curve at the design point is suggested as an objective function in the present optimization problem. Mean line performance analysis method is used to get the design and off-design characteristic curves of centrifugal compressor. The impeller exit angle, impeller exit height and impeller radius are chosen as design variables. The optimum shapes show the increase of surge margin for the surge margin optimization and increase of efficiency for the efficiency optimization in comparison with an initial shape.

Surge Phenomena Analytically Predicted in a Multi-stage Axial Flow Compressor System in the Reduced-Speed Zone

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권3호
    • /
    • pp.110-124
    • /
    • 2014
  • Surge phenomena in the zone of reduced speeds in a system of a nine-stage axial flow compressor coupled with ducts were studied analytically by use of a surge transient simulation code. Main results are as follows. (1) Expansion of apparently stable, non-surge working area of the pressure vs. flow field beyond the initial stage-stall line was predicted by the code in the lower speed region. The area proved analytically to be caused by significantly mismatched stage-working conditions, particularly with the front stages deep in the rotating stall branch of the characteristics, as was already known in situ and in steady-state calculations also. (2) Surge frequencies were found to increase for decreasing compressor speeds as far as the particular compressor system was concerned. (3) The tendency was found to be explained by a newly introduced volume-modified reduced surge frequency. It suggests that the surge frequency is related intimately with the process of emptying and filling of air into the delivery volume. (4) The upstream range of movement of the fluid mass having once passed through the compressor in surge was found to reduce toward the lower speeds, which could have caused additionally the increase in surge frequency. (5) The concept of the volume-modified reduced surge frequency was able to explain, though qualitatively at present, the behaviors of the area-pressure ratio parameter for the stall stagnation boundary proposed earlier by the author.

세라믹 필터를 이용한 동축 서지어레스터의 잔류전압 저감 (Residual Voltage Reduction of Coaxial Surge Arrestor Using Ceramic Filler)

  • 엄주홍;조성철;이태형;이영철
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.46-53
    • /
    • 2007
  • 현재 급속한 발전을 거듭하고 있는 이동통신 및 무선 멀티미디어 관련 서비스(W-CDMA, DMB, WiBro 등)의 확장은 이들 시스템을 구현하기 위한 수많은 기지국과 안테나 및 다수의 신호전송선로를 필요로 한다. 기지국 또는 중계시설의 안테나는 신호전송선로를 통하여 고가의 통신 네트워크 장비들과 결합되어 있으므로 주요 통신기기 시스템은 안테나를 통해 유입하는 직격뢰 및 유도뢰에 의한 순간적인 과전압의 위험에 항시 노출되어 있다. 현재 통신용 보호기로 사용되고 있는 가스방전튜브(GDT) 또는 협대역 스터브형 어레스터는 고속 광대역의 통신설비에 대한 뇌서지 보호수단으로서는 한계점이 드러나고 있다. 따라서 본 연구에서는 안테나를 통해 입사하는 뇌서지를 효과적으로 저감시켜주는 서지어레스터의 성능향상을 위해 세라믹 필터를 적용하였으며, 잔류전압 저감에 효과적임을 성능실험을 통해 입증하였다.

송전급 피뢰기용 ZnO 바리스터 소자의 전기적 특성 (Electrical Characteristics of ZnO Varistor for Transmission Class Arrester)

  • 김석수;박춘현;조이곤;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 반도체 재료 센서 박막재료 전자세라믹스
    • /
    • pp.179-182
    • /
    • 2004
  • ZnO varistor for transmission class arrester$({\Phi}65{\times}20mm)$ of 10kA(Class 3) grade was recently developed in korea and is tested for the properties by switching surge operating duty test to know the line discharge class and complex surge property in electric properties. To find out changing rate of residual voltage before and after lightning impulse residual voltage testing, the sample is cool to room temperature after finishing switching surge operating duty test, and the rate is good as 1.0~1.7%. The element had been considered as applicable ZnO varistor for electricity transmission from the test results of state conterl, switching surge operating duty, thermal stability and above test. But various test should be required for actual application because this is a part of the to be needed for application.

  • PDF