• Title/Summary/Keyword: Surface treatment system

Search Result 1,227, Processing Time 0.031 seconds

Performance of Organic light-emitting diode by various surface treatments of indium tin oxide (Indium tin oxide 기판의 표면처리에 따른 유기 발광다이오드의 특성)

  • Kim, Sun-Hyuk;Han, Jeong-Whan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.9
    • /
    • pp.1-10
    • /
    • 2002
  • We have done various treatments of indium tin oxide (ITO) surface for organic light-emitting diodes (OLEDs), and investigated the surface states by different surface treatments using atomic force microscopy (AFM) and Auger electron spectroscopy (AES). We have fabricated OLEDs deposited by ultra-high vacuum molecular beam deposition system and studied the characteristics of the OLEDs. We have observed the dramatical improvement of the performance of OLEDs fabricated on ITO substrates treated by $O_2$ plasma treatment reduces the carbon comtamination of ITO surfaces and increases the work function of ITO.

Ability to Maintain Postural Control while Standing on Perturbed Surfaces (바닥면의 교란에 따른 자세균형능력의 변화)

  • Park, Sung-Ha;Lee, Seung-Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.4
    • /
    • pp.146-152
    • /
    • 2008
  • This study was aimed to understand the effects of perturbed floor surface on human postural stability while standing. Ten subjects were asked to stand quietly on the surface with two angles of inclination ($0^{\circ}$ and $5^{\circ}$), two contamination conditions (dry and oil-contaminated), and three commercial floor materials (ceramic tile, coated wood, and vinyl tile). During each trial, a force plate with data acquisition systems was used to collect subject's center of pressure (COP) position. Measured COPs were then converted into the length of postural sway path in both subject's anterior-posterior (AP) and medio-lateral (ML) axis. Results showed that the length of sway path in ML axis was significantly affected by the angle of inclination and the type of floor material. The sway length was increased significantly at the inclination angle of $5^{\circ}$ and on the vinyl tile, respectively. The contamination condition, however, did not significantly affect the postural sway length in both AP and ML axis. The results imply that a proper treatment of floor surface and material is critical to preserving postural balance while standing.

SHEAR BOND STRENGTHS OF COMPOSITE RESIN TO PORCELAINS AMONG PORCELAIN REPAIR SYSTEMS (도재 수리시스템에 따른 도재와 복합레진의 전단결합강도)

  • Kim, Kyoung-Kyu;Shin, Sang-Wan;Lee, Jeong-Yeol;Kim, Young-Su
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.419-430
    • /
    • 2007
  • Purpose: This in vitro study evaluated shear bond strengths of surface treatment porcelains with four porcelain repair systems simulating intraoral bonding of composite resin to feldspathic porcelain or pressable porcelain. Material and methods: Eighty Porcelain disks were prepared. Group A: forty disk specimens were fabricated with Feldspathic Porcelain($Omega^{(R)}900$, Vident, Menlo Park, CA, USA). Group B: forty disk specimens were fabricated with Pressable Porcelain(IPS Empress 2 ingot, Ivoclar-Vivadent, Schaan, Liechtenstein, Germany). Each groups was divided into 4 subgroups and composite resin cylinders were bonded to specimen with one of the following four systems: Clearfil Porcelain Bond(L. Morita, Tustin, CA, USA), Ulradent Porcelain Etch. (Ultradent, Salt Lake City UT, USA), Porcelain Liner-M(Sun Medical Co., Kyoto, Japan), Cimara Kit(Voco, Germany). After surface conditioning with one of the four porcelain repair systems substrate surfaces of the specimen were examined microscopically(SEM). Shear bond strengths of specimens for each subgroup were determined with a universal testing machine (5mm/min crosshead speed) after storing them in distilled water at $37{\pm}1^{\circ}C$ for 24 hours. Stress at failure was measured in $MP_a$, and mode of failure was recorded. Differences among four repair systems were analyzed with two way ANOVA and Duncan test at the 95% significance level. Results: In the scanning electron photomicrograph of the treated porcelain surface, hydrofluoric acid etched group appeared the highest roughness. The shear bond strength of the phosphoric acid etched group was not significantly(p>0.05) different between feldspathic porcelain and pressable porcelain. But in no treatment and roughened with a bur group, the shear bond strength of the feldspathic porcelain was significantly higher than that of the pressable porcelain. In hydrofluoric acid etched group, the shear bond strength of the pressable porcelain was significantly higher(p<0.05). Conclusion: 1. Treatment groups showed significantly greater shear bond strengths than no treatment group(p<0.05). 2. Group with more roughened porcelain surface did not always show higher shear bond strengths. 3. In phosphoric acid etched group, there was no significant difference in shear bond strength between feldspathic porcelain and pressable porcelain(p>0.05). However in the other groups, there were significant differences in shear bond strengths between feldspathic porcelain and pressable porcelain(p<0.05).

Effect of powder activated carbon replacement on HCPAC-MBR system operation (고농도 분말활성탄 결합 MBR 운전에 대한 활성탄 교체주기의 영향)

  • Lee, Chae-Ha;Kim, Jin-Tae;Lee, Jung-Hyun;Seo, Gyu-Tae;Kim, In S.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.141-148
    • /
    • 2008
  • This study was conducted to evaluate the effect of PAC(Powder Activated Carbon) retention time on stable operation of high concentration powered activated carbon(HCPAC-MBR) in the treatment of secondary domestic wastewater. The pilot scale HCPAC-MBR system was operated at two different SRTs, 25 days and 100 days. The main drawback of HCPAC-MBR system was the rapid increase of trans-membrane pressure. The increase rate of trans-membrane pressure was proportional to SRT value at constant flux. This result seemed to be caused by reduced amount of EPS adsorbed on the PAC in the reactor by decreasing the SRT of the PAC. The particle size of the PAC was also influenced by SRT. The PAC size was decreased as SRT was increased. The change of particle size could be one reason for the change of trans-membrane pressure. The pore volume in the cake-layer formed on the membrane surface became to be increased by reducing SRT, because the cake-layer was highly composed of the PAC. Therefore, increased pore volume might play a role to reduce the trans-membrane pressure. The removal rate of E260 and TOC was also inversely proportional to SRT value.

NUMERICAL METHOD FOR MOLTEN METAL FLOW SIMULATION WITH CUT CELL (Cut Cell을 고려하는 주조유동 해석 방법)

  • Choi, Y.S.;Hong, J.H.;Hwang, H.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.518-522
    • /
    • 2011
  • Cartesian grid system has mainly been used in the casting simulation even though it does not nicely represent sloped and curved surfaces. These distorted boundaries cause several problems. A special treatment is necessary to clear these problems. A cut cell method on Cartesian grids has been developed to simulate three-dimensional mold filling Cut cells at a cast-mold interface are generated on Cartesian grids. Governing equations were computed using volume and areas of cast at cut cells. In this paper, we propose a new method that can consider the cutting cells which are cut by casting and mold based on the patial cell treatment (PCT). This method provides a better representation of geometry surface and will be used in the computation of velocities that are defined on the cell boundaries in the Cartesian gird system. Various test examples for several casting process were computed and validated. The analysis results of more accurate fluid flow pattern and less momentum loss owing to the stepped boundaries in the Cartesian grid system were confirmed. We can know the momentum energy at the cut cell is conserved by using the cut cell method. By using the cut cell method. performance of computation gets better because of reducing the whole number of meshes.

  • PDF

A Trend on Quality Transformation of Waterproof Agent and Admixture of Cement for Concrete Surface Treatment (콘크리트 표면처리용 시멘트 액체방수제의 품질동향)

  • 최은수;김영근;박헌일;정순자
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.557-560
    • /
    • 2003
  • This study deals with the method of test for waterproof agent and admixture of cement, and especially, the effect on bond strength between waterproofing layer and mortar or concrete substrate in building construction. Quality of that has been managed according to it of construction standard manual, housing construction manual, 건, and Q until performance of that is specified by law as KS F 4923. Therefore this study focus on the quality and trend for a fatty system and PCM(Polymer Cement Mortar)

  • PDF

A Study on the Fabrication of Bi System Thick Film Using Melting Process (용융법에 의한 Bi계 Thick Film 합성)

  • Lee, Sang-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1775-1777
    • /
    • 2009
  • BiSrCaCuO films were prepared on MgO single substerate at $885^{\circ}C$ by melt process. The films showed superconductivity above liquid nitrogen temperature (Tc= 96K). To investigate the effect of a melting temperature on the forming of the surface texturing, the samples were prepared under various temperature. The used powder was of high Tc phase. It is implies that the origin of the properties due to the heat treatment.

A Study on the Correlation between Surface Electromyography and Assessment Scale for Facial Palsy (안면신경마비의 평가척도와 SEMG 검사 결과 간의 상관성 연구)

  • Kim, Jong Uk;Lee, Hyung Geol;Jung, Da Jung;Choi, Yoo Min;Song, Beom Yong;Yook, Tae Han;Kim, Woo Kyung;Kim, Lak Hyung
    • Journal of Acupuncture Research
    • /
    • v.30 no.5
    • /
    • pp.107-116
    • /
    • 2013
  • Objjectives : The purpose of this study is to investigate the correlation between surface electromyography(SEMG) and assessment scales for facial palsy. Methods : The subjects for this study were 21 patients who had peripheral facial nerve palsy. We analyzed about the correlation between the results of SEMG and facial nerve assessment scales that were carried out at the same time. The assessment scales used in this study were House-Brackmann scale, Yanagihara grading system, Sunnybrook facial grading system. Results : There are considerable correlation between the results of SEMG and the results of three kinds of assessment scales for facial nerve palsy. Conclusions : SEMG may be an objective examination for facial nerve palsy. Some research aimed at development of SEMG examination guideline for facial nerve palsy will be needed after this. And we expect that many researches for development of diagnostic equipments or treatment equipments that utilize SEMG will proceed.

Improvement of Soil Moisture Initialization for a Global Seasonal Forecast System (전지구 계절 예측 시스템의 토양수분 초기화 방법 개선)

  • Seo, Eunkyo;Lee, Myong-In;Jeong, Jee-Hoon;Kang, Hyun-Suk;Won, Duk-Jin
    • Atmosphere
    • /
    • v.26 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Initialization of the global seasonal forecast system is as much important as the quality of the embedded climate model for the climate prediction in sub-seasonal time scale. Recent studies have emphasized the important role of soil moisture initialization, suggesting a significant increase in the prediction skill particularly in the mid-latitude land area where the influence of sea surface temperature in the tropics is less crucial and the potential predictability is supplemented by land-atmosphere interaction. This study developed a new soil moisture initialization method applicable to the KMA operational seasonal forecasting system. The method includes first the long-term integration of the offline land surface model driven by observed atmospheric forcing and precipitation. This soil moisture reanalysis is given for the initial state in the ensemble seasonal forecasts through a simple anomaly initialization technique to avoid the simulation drift caused by the systematic model bias. To evaluate the impact of the soil moisture initialization, two sets of long-term, 10-member ensemble experiment runs have been conducted for 1996~2009. As a result, the soil moisture initialization improves the prediction skill of surface air temperature significantly at the zero to one month forecast lead (up to ~60 days forecast lead), although the skill increase in precipitation is less significant. This study suggests that improvements of the prediction in the sub-seasonal timescale require the improvement in the quality of initial data as well as the adequate treatment of the model systematic bias.

Effects of Surface Treatments of The Zirconium-Based Ceramic on the Bond Strength of Resin Cement (지르코니움 세라믹에서 표면 처리 방법이 레진 시멘트의 접착력에 미치는 영향)

  • Park, Kyung-Seok;Shin, Soo-Youn;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.3
    • /
    • pp.221-230
    • /
    • 2006
  • Recently, the need for esthetic results has increased the interest for all-ceramic crown prosthesis. Furthermore, the development of zirconium core via CAD/CAM system has allowed the all ceramic restorations to be applied to almost all fixed prosthesis situations. But, the increased strength has been reported to increase in proportion with the bond strength of cement, and recently, the tribochemical system which increases the bond strength through, silica coating and silanization has been introduced. The purpose of this study was to compare the $Rocatec^{TM}$ system and $CoJet^{TM}$ system with the traditional acid etching and silanization method of the irconium based ceramic. The surface character was observed via SEM(X2000), and the bond strength with the resin cement were measured. 50 In-Ceram Zirconia (Adens, Korea) discs were fabricated and embedded in resin, group 1 was treated with glass-bead blasting and cleaning, group 2 was treated with 20% HF for 10 minutes and silanized, group 3 was treated with the $Rocatec^{TM}$ system, and group 4 was treated with the $CoJet^{TM}$ system. Each group was comprised of 10 specimens. The specimens were cemented to a $3mm{\times}5mm$ resin block with Super-Bond C&B. The shear bond strength was measured with the $Instron^{(R)}$ 8871 at a crosshead speed of 0.5mm/min. The results were as follows. 1. According to SEM results, there were little difference between group 1 & group 2, but in group 3 and 4, silica coating was detected and there was increase in surface roughness. 2. The shear bond strength decreased in the order of group 3(46.28MPa), group 4(42.04MPa), group 2(31.56MPa), and group 1(27.46MPa). 3. There was significant differnce between group 1&2 and group 3&4(p<0.05). From the results above, it can be considered that the conventional method of acid etching and silane treatment cannot increase the bond strength with resin cements, and that by applying the tribochemical system of $Rocatec^{TM}$ system and $CoJet^{TM}$ system, we can achieve a stronger all ceramic restoration. Further studies on surface treatments to increase the bond strength are thought to be needed.