• 제목/요약/키워드: Surface treatment$NO_x$

검색결과 114건 처리시간 0.03초

Ag/$Al_2O_3$ 촉매하의 HC-SCR에서 수소 풍부 에탄올의 반응 특성 (Kinetics of Hydrogen Rich Ethanol as Reductant for HC-SCR over $Al_2O_3$ Supported Ag Catalyst)

  • 이주헌;박정환;김성수;유승준;김진걸
    • 한국수소및신에너지학회논문집
    • /
    • 제21권6호
    • /
    • pp.519-525
    • /
    • 2010
  • Ethanol was used as reductant to remove $NO_x$ over Ag/$Al_2O_3$ catalyst via SCR from stationary emission source. Among the tested hydrocarbon reductants, ethanol showed highest de-$NO_x$ performance over the Ag/$Al_2O_3$ catalyst. De-$NO_x$ efficiency of about 83% was obtained in the condition of GHSV 20,000 $hr^{-1}$, $NO_x$ 200 ppm, CO 200 ppm, $O_2$ 13%, $H_2O$ 5% and mole ratio of ethanol/$NO_x$ = 2 between temperature of $300^{\circ}C$ and $400^{\circ}C$. While $SO_2$ presence in the $NO_x$ exhaust suppressed the catalytic activity, catalyst with acid (0.7% $H_2SO_4$) treatment of catalyst showed higher catalytic activity, where In-Situ DRIFT showed S presence over catalyst surface was increased after acid treatment of catalyst. From in-situ DRIFT and SCR results, it was concluded that sulfur presence over the surface of Ag/$Al_2O_3$ catalyst was the dominant factor to control the de-$NO_x$ reaction yield via HC-SCR from the exhausted gas including $SO_2$.

SOx 함유 HC-SCR에서 산처리 Ag/Al2O3 촉매의 반응 특성 (Effect of SOx on HC-SCR Kinetics over Ag/Al2O3 Catalyst)

  • 이주헌;박정환;김성수;유승준;김진걸
    • 한국수소및신에너지학회논문집
    • /
    • 제22권5호
    • /
    • pp.714-720
    • /
    • 2011
  • Ethanol was used as reducing agent to remove $NO_x$ exhaust from the stationary source. Pre-treatment with sulfuric acid over $Ag/Al_2O_3$ catalyst was dedicated to overcome the $SO_2$ poisoning effect. The $NO_x$ reduction experiment was performed under the simulated condition of power plant The increased surface area with higher CPSI devoted to increase de-$NO_x$ yield. De-$NO_x$ yield of the $NO_x$ exhaust containing 20 ppm of $SO_2$ increased after acid treatment with 0.7% $H_2SO_4$ over 4.0% $Ag/Al_2O_3$, where the increased dispersion of Ag found from the results of XRD and XPS was the dominant factor for the increased de-$NO_x$ yield. However, the reason for the decreased de-$NO_x$ yield with the acid treatment of higher concentration (1.0% and 2.0%) of $H_2SO_4$ was found to be due to the formation of $Ag_2SO_4$ crystallites found from XRD result. Acid-treated $Ag/Al_2O_3$ catalyst showed maximum de-$NO_x$ yield at higher temperature than non-treated $Ag/Al_2O_3$ catalyst did.

표면처리가 지르코니아와 레진 시멘트의 전단결합강도에 미치는 효과 (The Effect of Surface Treatment on the Shear Bond Strength of Resin Cement to Zirconia Ceramics)

  • 정승현;김계순;이재인;이진한;김유리;조혜원
    • 구강회복응용과학지
    • /
    • 제25권2호
    • /
    • pp.83-94
    • /
    • 2009
  • 본 연구는 지르코니아의 연마 정도와 tribochemical coating 등 두 가지 표면처리가 두 가지 레진 시멘트, 즉 Bis-GMA 계 레진 시멘트와 자가접착형 레진 시멘트와의 결합력에 어떠한 영향을 미치는가를 연구 비교하였다. $1{\mu}m$$50{\mu}m$ 의 다이아몬드 디스크로 연마한 지르코니아 시편을 만들어 접착기전이 다른 두 가지 레진 시멘트 RelyX ARC(3M Espe, USA)와 RelyX Unicem(3M Espe, USA)으로 결합시켰다. 지르코니아 표면에 로카텍 시스템 처리를 한 군과 하지 않은 군을 비교해 지르코니아와 레진 시멘트 사이의 전단결합강도를 측정하여 다음과 같은 결론을 얻었다. 1. 로카텍 시스템으로 표면처리를 한 군이 하지 않은 군에 비해 높은 전단결합강도를 보였다(P < 0.001). 2. 로카텍 시스템으로 표면처리를 한 군에서는 $50{\mu}m$ 연마 군이 $1{\mu}m$ 연마 군에 비해 높은 전단결합강도를 보였으며 통계학적 유의성을 보였다(P <0.001). 그러나 로카텍 처리를 하지 않은 군에서는 $50{\mu}m$ 연마 군과 $1{\mu}m$ 연마 군 간의 차이는 없었다(P >0.01). 3. RelyX Unicem을 이용하여 접착한 군이 RelyX ARC를 이용하여 접착한 군에 비해 높은 전단결합강도를 보였다(P < 0.01). 본연구의 결과에 따르면, 새로운 형태의 자가접착형 레진 시멘트의 지르코니아와의 전단결합강도는 기존의 Bis-GMA 계 레진 시멘트보다 우수하였으나, 제조자의 지시와 달리 지르코니아 표면에 로카텍 처리를 하는 것이 전단결합강도의 증진에 매우 효과적이었다.

촉매담지 세라믹 필터의 표면 산처리 효과 (Efficiency of catalyst-coated ceramic filter with acid treatment)

  • 조을훈;서광석;김수효;신민철;신병길;김진성;이희수
    • 한국결정성장학회지
    • /
    • 제18권2호
    • /
    • pp.91-95
    • /
    • 2008
  • 코디어라이트를 원료로 하여 다공성 세라믹 필터를 제조하였고, 진공함침법으로 $V_2O_5$ 촉매를 코팅하였다. 제조된 세라믹 필터의 기공률은 58%, 압축강도는 10 MPa, 400$^{\circ}C$, 5 cm/sec의 유속에서 압력손실은 1,200 Pa이었다. $V_2O_5$ 촉매의 경우 $NO_x$에 대해 80% 이상의 처리효율을 나타내었고, 산처리에 의한 필터의 비표면적 증가를 통해 처리효율을 약 10%개선할 수 있었다. 이는 필터의 비표면적 증가를 통해 코팅된 촉매의 분산성을 향상시킴으로써 촉매의 활성점이 증대되었기 때문으로 판단된다.

표면처리방법이 지르코니아와 레진시멘트 간의 전단결합강도에 미치는 영향 (The Effect of Surface Treatment on the Shear Bond Strength of Zirconia Ceramics to Resin Cemen)

  • 김경수;김정미;김유리
    • 구강회복응용과학지
    • /
    • 제29권1호
    • /
    • pp.69-79
    • /
    • 2013
  • 본 연구의 목적은 각각 다른 표면처리를 한 지르코니아를 레진시멘트로 접착한 후 전단결합강도를 평가, 비교하는 것이다. 디스크 모양의 산화 지르코늄(3-TZP, Kyoritsu, Tokyo, Japan) 시편 120 개를 다음과 같이 표면처리 하였다. (1)110 ${\mu}m$ 산화 알루미나 분사 처리 (2)Silica coating(RocatecTM, 3M ESPE) (3)처리하지 않음 시편을 한 군당 10 개씩 총 6 개군으로 나누어 두 개의 지르코니아 시편을 자가 접착형 레진 시멘트(RelyX U-200, 3M ESPE)로 합착하였다. (1)처리하지 않음/처리하지 않음 (2)처리하지 않음/110 ${\mu}m$ 산화 알루미나 분사처리 (3)처리하지 않음/Silica coating (4)110 ${\mu}m$ 산화 알루미나 분사 처리/110 ${\mu}m$ 산화 알루미나 분사 처리 (5)110 ${\mu}m$ 산화 알루미나 분사 처리/Silica coating (6)Silica coating/Silica coating. 각 군의 전단결합강도를 만능시험기로 측정하였다. 표면처리에 따른 결합강도의 차이를 살펴보기 위해 일원변량분석(One-way ANOVA)을 이용하고 사후 분석으로 Tukey HSD test를 실시하였다. Silica coating을 한 두 개의 시편을 접착한 군이 가장 높은 결합 강도를 보였다(P<0.05). 표면 처리하지 않은 시편을 접착한 군과 두 개의 시편 모두 알루미나 분사 처리한 시편을 접착한 군은 서로 간에 유의한 차이를 보이지 않았으며, 그 외의 군에 비해서는 유의하게 낮았다(P<0.05). 본 연구의 결과에 따르면 Silica coating은 자가중합형 레진시멘트를 이용하여 접착한 두 지르코니아 간의 결합을 증진시키는데 효과적이었다.

Optimization of ultrasonification of slaughter blood for protein solubilization

  • Jeon, Yong-Woo
    • Environmental Engineering Research
    • /
    • 제20권2호
    • /
    • pp.163-169
    • /
    • 2015
  • In this study, we attempted to solubilize protein in slaughter blood (SB) using ultrasonic technology. The application of ultrasonic technology can make enzymatic degradation of SB more effective, which has no comparable alternative for treatment. The SB was homogenized by grinding it for 10 minutes at 10,000 rpm as a pretreatment for preventing its clotting, and then ultrasonic treatment was attempted to solubilize protein in SB. To maximize the efficiency of ultrasonic treatment for SB, the optimum condition of ultrasonic frequency (UF) was determined to be 20 kHz. To optimize the operation conditions of ultrasonification with 20 kHz of frequency, we used response surface methodology (RSM) based on ultrasonic density (UD) and ultrasonification time (UT). The solubilization rate (SR) of protein (%) was calculated to be $101.304-19.4205X_1+0.0398X_2+7.9411X_1{^2}+0.0001X_2{^2}+0.0455X_1X_2$. From the results of the RSM study, the optimum conditions of UD and UT were determined at 0.5 W/mL and 22 minutes, respectively, and SB treated under these conditions was estimated to have a 95% SR. Also, experimentally, a 95.53% SR was observed under same conditions, accurately reflecting the theoretical prediction of 95%.

EFFECT OF SURFACE TREATMENT METHODS ON THE SHEAR BOND STRENGTH OF RESIN CEMENT TO ZIRCONIA CERAMIC

  • Lee, Ho-Jeong;Ryu, Jae-Jun;Shin, Sang-Wan;Sub, Kyu-Won
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.743-752
    • /
    • 2007
  • Statement of problem. The aims of the study were to evaluate the effect of current surface conditioning methods on the bond strength of a resin composite luting cement bonded to ceramic surfaces and to identify the optimum cement type. Material and methods. The sixty zirconia ceramic specimens(10 per group) with EVEREST milling machine and 60 tooth block were made. The zirconia ceramic surface was divided into two groups according to surface treatment: (1) airborne abrasion with $110{\mu}m$ aluminum oxide particles; (2) Rocatec system, tribochemical silica coating. The zirconia ceramic specimens were cemented to tooth block using resin cements. The tested resin cements were Rely X ARC, Panavia F and Superbond C&B. Each specimen was mount in a jig of the universal testing machine for shear strength. The results were subjected to 2-way ANOVA and Post hoc tests was performed using Tukey, Scheffe, and Bonferroni test. Results. The mean value of shear bond strength(MPa) were as follows: $$RelyXARC(+Al_2O_3),5.35{\pm}1.69$$; $$RelyXARC(+Rocatec),8.50{\pm}2.13$$; $$PanaviaF(+Al_2O_3),9.58{\pm}1.13$$; $$PanaviaF(+Rocatec),12.98{\pm}1.71$$; $$SuperbondC&B(+Al_2O_3)8.27{\pm}2.04$$; $$SuperbondC&B(+Rocatec),14.46{\pm}2.39$$. There was a significant increase in the shear bond strength when the ceramic surface was subjected to the tribochemical treatment(Rocatec 3M) in all cement groups(P<0.05). Bonding strengths of cements applied to samples treated with $Al_2O_3$ were compared; Rely X ARC showed the lowest values, whereas Panavia F cement showed higher value than that of Superbond C&B group with no statistical significance. When the bond strength of cements with of Rocatec treatment was compared, Rely X ARC showed lowest values. Overall, it was apparent that tribochemical treated Super-Bond possessed higher mean bond strength (14.46MPa; P<0.05) than that of Panavia F cement group with no significance. Conclusions. Silica coating followed silanization(Rocatec treatment) increase the bond strength between resin cement and zirconia ceramic. Panavia F containing phosphate monomer and Superbond C&B comprised of 4-META tend to bond chemically with zirconia ceramic, thus demonstrating higher bond strength compared to BisGMA resin cement. Superbond C&B has shown to have highest value of bonding strength to zirconia ceramic after Rocatec treatment compared to other cement.

디젤 NOx 후처리 장치에 있어서 암모니아 SCR 시스템 혼합영역 내 가스유동의 유입열 수치모델링에 관한 연구 (A Study on Numerical Modeling of the Induced Heat to Gaseous Flow inside the Mixing Area of Ammonia SCR System in Diesel Nox After-treatment Devices)

  • 배명환;샤이풀
    • 대한기계학회논문집B
    • /
    • 제32권11호
    • /
    • pp.897-905
    • /
    • 2008
  • Selective catalytic reduction(SCR) is known as one of promising methods for reducing $NO_x$ emissions in diesel exhaust gases. $NO_x$ emissions react with ammonia in the catalyst surface of SCR system at working temperature of catalyst. In this study, to raise the reacting temperature when the exhaust gas temperature is too low, a heater is located at the bottom of SCR reactor. At an ambient temperature, ammonia is radially injected perpendicular to the exhaust gas flow at inlet pipe and uniformly mixed in the mixing area after being impinged against the wall. To predict the turbulent model inside the mixing area of SCR system, the standard ${\kappa}\;-\;{\varepsilon}$ model is applied. This work investigates numerically the effects of induced heat on the gaseous flow. The results show that the Taylor-$G{\ddot{o}}rtler$ type vortex is generated after the gaseous flow impinges the wall in which these vortices influence the temperature distribution. The addition of heat disturbs the flow structure in bottom area and then stretching flow occurs. Vorticity strand is also formed when heat is continuously increased. Constriction process takes place, however, when a further heat input over a critical temperature is increased and finally forms shed vortex which is disconnected from the vorticity strand. The strong vortex restricts the heat transport in the gaseous flow.

표면처리방법이 지르코니아와 수종의 시멘트의 전단결합강도에 미치는 영향 (The influence of surface conditioning on the shear bond strength of self-adhesive resin cement to zirconia ceramics)

  • 정지혜;정승현;조혜원;김유리
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.251-258
    • /
    • 2010
  • 연구 목적: 이 연구의 목적은 표면처리방법이 지르코니아와 네 종류의 시멘트의 전단결합 강도에 미치는 영향을 평가하는 것이다. 연구 재료 및 방법: 총 120개의 디스크 모양의 산화 지르코늄 (3Y-TZP, Kyoritsu, Tokyo, Japan) 시편을 다음과 같이 표면처리 하였다: (1) $110\;{\mu}m$ 산화 알루미나 분사처리 (2) Silica coating ($Rocatec^{TM}$ 3M ESPE)를 이용한 표면처리 (3) 처리하지 않음. 각각의 표면 처리 후, 2종의 자가 접착형 시멘트 (RelyX Unicem, Maxcem)와 레진 강화 글라스 아이오노머 시멘트 (RelyX Luting), Bis-GMA 레진 시멘트 (Nexus3)를 시편에 부착하였으며 각 군은 UTM을 이용하여 전단결합강도를 측정하였다. 표면처리, 시멘트의 종류에 따른 결합강도의 차이를 살펴보기 위하여 일원변량분석 (One-way ANOVA)과 이원변량분석 (two-way ANOVA)을 이용하고 사후 분석으로 Tukey HSD test를 실시하였다. 결과: 로카텍 처리 후, RelyX Unicem을 부착한 군이 가장 높은 결합 강도를 보였으며 (P<.05) 알루미나 분사처리를 한 군과 로카텍 처리를 한 군은 아무런 처리를 하지 않은 군보다 유의하게 높은 결합 강도를 보였다 (P<.05). 또한 모든 표면상태에서 RelyX Luting은 다른 군에 비해 통계적으로 유의하게 가장 낮은 결합강도를 보였다 (P<.05). 결론: 본 연구의 결과에 따르면 RelyX Unicem은 지르코니아와 강한 결합력을 보였으며 로카텍 처리는 결합을 증진시키는데 효과적이었다.

임플랜트 표면 처리 방법에 따른 골조직 반응에 대한 연구 (ON THE BONE TISSUE REACTION TO IMPLANTS WITH DIFFERENT SURFACE TREATMENT METHODS)

  • 김용재;조인호
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.71-84
    • /
    • 2007
  • Statement of problem: Implant surface characteristics plays an important role in clinical success and many studies have been made for improvement of success by changing surface roughness. Purpose: Appropriate increase of surface roughness increases the activity of osteoblast and enhance contact and retention between bone and implant. Material and method- Machined, SLA and RBM surface implants, which are the most commonly used implants were implanted into the tibia of rabbits and after 1 week, 4 weeks, 8 weeks and 12 weeks there were histologic and histomorphometric analysis and study for bone gradient and change of Ca/P ratio using EDS(Energy Dispersive X-ray Spectroscope). Results: Comparison of bone-implant contact showed no significant difference among each implant. In comparison of bone area rates, SLA showed higher value with significant difference at 1 week and 4 weeks, and SLA and RBM at 8 weeks than Machined implant (p<0.05). In analysis of bone constituents with EDS, titanium was specifically detected in new bones and the rates were constant by surface treatment method or period. In case of Ca/P ratio, according to surface treatment method, each group showed significant difference. Lots of old bone fragments produced during implantation remained on the rough surface of RBM implant surface and each group showed histological finding with active synthesis of collagen fibers until 12 weeks. In transmission electronic microscopic examination of sample slice after elapse of twelve weeks, tens nm of borderline (lamina limitans like dense line)was seen to contact the bone, on the interface between bone and implant. Conclusion: SLA and RBM implant with rough surface shows better histomorphometrical result and the trend of prolonged bone formation and maturation in comparison with Machined implant. In addition, implant with rough surface seems to be helpful in early stage bone formation due to remaining of old bone fragments produced in implantation. From the results above, it is considered to be better to use implant with rough surface in implantation.