• 제목/요약/키워드: Surface temperature distribution measurement

검색결과 114건 처리시간 0.027초

Sheet Molding Compound 금형의 가열채널설계 및 평가기술 (Beating Channel Layout Design and Evaluation Technology for SMC Molds)

  • 허영무;고영배;이종훈;이성희
    • 소성∙가공
    • /
    • 제14권3호
    • /
    • pp.263-268
    • /
    • 2005
  • Heating channel layout design and evaluation technology for SMC molding system was investigated in this work. Traditional rules of cooling channel design in injection molding were applied to the present work. Finite element thermal analysis with $ANSYS^{TM}$ was performed to evaluate the temperature distribution of SHC mold surface. SMC mold was manufactured to evaluate the effect of a proposed heating channel layout system on the temperature distribution of SMC mold surface and infrared camera was applied to a measurement of temperature distribution. It was shown that infrared camera application was possible in a measurement of temperature distribution on SHC mold surface.

탄소강 담금질 공정의 온도 측정방법에 대한 고찰 (A Study on Temperature Measurement for Quenching of Carbon Steel)

  • 김동규;정경환;강성훈;임용택
    • 소성∙가공
    • /
    • 제19권1호
    • /
    • pp.25-31
    • /
    • 2010
  • To achieve desired microstructure and mechanical property of a manufacturing product, heat treatment process is applied as a secondary process after forging. Especially, quenching process is used for improving strength, hardness, and wear resistance since phase transformation occurs owing to rapid heat transfer from the surface of the specimen. In the present paper, a study on surface temperature measurement for water quenching of eutectoid steel was investigated. In order to determine the temperature history in experiments, three different measuring schemes were used by varying installation techniques of K-type thermocouples. Depending on the measured temperature distribution at the surface of the specimen, convective heat transfer coefficients were numerically determined as a function of temperature by the inverse finite element analysis considering the latent heat generation due to phase transformation. Based on the inversely determined convective heat transfer coefficient, temperature, phase, and hardness distributions in the specimen after water quenching were numerically predicted. By comparing the experimental and computational hardness distribution at three different locations in the specimen, the best temperature measuring scheme was determined. This work clearly demonstrates the effect of temperature measurement on the final mechanical property in terms of hardness distribution.

Off-Axis 디지털홀로그래피를 이용한 마이크로히터의 실시간 온도분포측정 (Real Time Temperature Distribution Measurement of a Microheater by Using Off-Axis Digital Holography)

  • 체랭돌가르;백병준;김대석
    • 한국진공학회지
    • /
    • 제20권2호
    • /
    • pp.106-113
    • /
    • 2011
  • 본 논문은 마이크로히터표면의 실시간 온도분표측정을 위한 마하젠더 간섭계 기반의 off-axis 디지털홀로그래피기술에 대한 것이다. 제안된 방법은 재료표면의 온도분포에 직접적인 함수인 2차원 위상 분포를 측정하고, 이를 통해 실시간으로 재료표면의 온도 map을 측정할 수 있다. 본 논문에서는 섭씨 20도에서 60도 사이의 온도구간에서 마이크로히터 표면의 위상변화와 실제표면온도가 선형적인 관계가 있음을 실험적으로 보였다. 제안된 방법은 재료표면의 온도분포를 실시간으로 측정하고자 하는 다양한 응용분야에 적용될 수 있을 것으로 기대된다.

적외선 패널히터의 온도분포 측정 (Measurement of Temperature Distribution in the Infrared Panel Heater)

  • 이공훈;하수석;김욱중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1178-1183
    • /
    • 2004
  • Temperature distribution and heating characteristic of the panel heater for infrared heating have been investigated. The temperature variation with time is firstly measured with the thermocouple to figure out the response time of the heater to the power input. The heater reaches faster to the steady state in comparison to the ceramic heater. The infrared thermal imaging system is utilized to investigate the temperature distribution over the heater surface. The measured thermal images show that the thermal boundary layer induced by the free convection near the heater surface affects the temperature distribution on the surface. The images also show the fairly good uniformity of the temperature distribution in the core region of the surface.

  • PDF

SMC 금형의 가열채널레이아웃 평가기술에 관한 연구 (A Study of Evaluation Technology for Heating Channel Layout in SMC Molds)

  • 이성희;고영배;이종훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.580-584
    • /
    • 2004
  • In the present study, an evaluation technology for heating channel layout was investigated in SMC molding system design. Conventional design rules of cooling channel in injection molding process were applied to the present work. Finite element thermal analysis with ANSYSTM was performed to evaluate the temperature distribution of mold surface. SMC mold was manufactured to test the effect of a proposed heating channel layout system on the temperature distribution of mold surface and infrared camera was applied to a measurement of temperature. It was shown that infrared camera application was possible in a measurement of temperature distribution on mold surface.

  • PDF

온돌난방주택의 난방방식별 열 특성에 관한 실험연구 (Experimental Study on the Thermal Characteristics in Ondol Heating Systems)

  • 윤정숙
    • 한국주거학회논문집
    • /
    • 제1권1호
    • /
    • pp.91-102
    • /
    • 1990
  • The aim of this study is to discover thermal characteristics of Ondol heating systems. The housing subjected was categorized into detached single family houses and apartments, reinforced concrete and brick structures, intermittent and continous heating system, and the space subjected was bedroom. In order to understand the thermal characteristics of each floor heating systems, the vertical distribution of indoor temperature and the distribution of surface temperature on the floor were measured. The vertical distribution of indoor temperature except the measurement point 1 largely showed average temperature distribution, and the temperature of the measurement point 1 in the housing surveyed showed the highest temperature in the house "sample A" because of the radiation heating from the floor of the Ondol room. As the result of the measurement, the thermal characteristics of each heating system were more stable distribution in apartments of R.C structure.structure.

  • PDF

열원의 온도분포 해석을 통한 접촉표면의 온도측정 (Temperature Measurement of the Contact Surface from the Analysis of Temperature Distribution of the Hot Spots)

  • 정동윤
    • Tribology and Lubricants
    • /
    • 제9권1호
    • /
    • pp.16-21
    • /
    • 1993
  • A method has been developed to measure the surface temperature in a sliding tribosystem. The determination of the surface temperature was inferred from the temperature of hot spots which were generated by frictional heat. The temperature of hot spots was determined by regressing those digitized data on Gecim-Winer's theoretical model. The experimental results are discussed considering the important factors such as PV and frictional heat. The surface temperature rise is related to the thermal conductivity in low PV range. As PV increases, it reaches nearly constant value called the critical temperature.

SURFACE CHARACTERIZATION OF CU ELECTRODES IN ELECTROCHEMICAL REDUCTION OF $CO_2$ BY CORE LEVEL X-RAY PHOTOELECTRON SPECTROSCOPY AND VALENCE LEVEL PHOTOELECTRON EMISSION MEASUREMENT

  • Terunuma, Y.;Saitoh, A.;Momose, Y.
    • 한국표면공학회지
    • /
    • 제29권6호
    • /
    • pp.728-734
    • /
    • 1996
  • To obtain the relation in the electrochemical reduction of $CO_2$ in aqueous $KHCO_3$ colution between an activity for the product and the nature of Cu electrode, the electrode surface was characterized by using two methods: X-ray photoelectron spectroscopy (XPS) and photoelectron emission (PE) measurement. Electrolyses were performed with Cu electrodes pretreated in several ways. The distribution of the products changed drastically with electrolysis time and the pretreatment method. The features in XPS spectra were closely connected with the product distribution. The oxide film at the electrode surface was gradually reduced to bare Cu metal with electrolysis time, resulting in a variation of the product distribution. PE was measured by verying the wavelength of incident light at several temperatures. The dependence of PE on the measurement temperature changed greatly before and after electrolysis.

  • PDF

EHC 기반 Urea-SCR 시스템 히터 표면온도 분포의 1-D 모델링 (1-D Modeling of Heater Surface Temperature Distribution in EHC-based Urea-SCR System)

  • 박선홍;손지현;문석수;오광철;장성욱;박성서
    • 한국분무공학회지
    • /
    • 제27권1호
    • /
    • pp.11-17
    • /
    • 2022
  • In upcoming Post Stage-V and Tier 5 regulations of construction machineries, nitrogen oxide (NOx) emissions are strictly limited in cold start conditions. In response to this, a method of improving NOx conversion efficiency has been applied by installing an electric heating catalyst (EHC) in front of conventional urea-SCR systems so that the evaporation and thermal decomposition of urea-water solution can be promoted in cold start conditions. In this strategy, the evaporation and thermal decomposition of urea-water solution and corresponding NOx conversion efficiency are governed by temperature conditions inside the EHC. Therefore, characterizing the temperature distribution in the EHC under various operating conditions is crucial for the optimized operation and control of the EHC in Urea-SCR systems. In this study, a 1-D modeling analysis was performed to predict the heater surface temperature distribution in EHC under various operating conditions. The reliability of prediction results was verified by comparing them with measurement results obtained using an infrared (IR) camera. Based on 1-D analysis results, the effects of various EHC operation parameters on the heater surface temperature distribution were analyzed and discussed.

쑥뜸과 1064 nm 파장의 근적외선 레이저로 가열된 아가젤 조직 팬텀 심부의 온도분포 가시화 (Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 nm Infrared Laser)

  • 조지용;김중경
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.54-59
    • /
    • 2010
  • A laser moxibustion therapy device having effect similar to that of traditional moxibustion is being developed using 1064 nm infrared laser. The therapy device allows direct interaction of laser light with the tissue rendering temperature distribution both on the skin surface and deep under the skin. We made a device that could measure temperature of deep under the surface of agar gel tissue phantom using thermocouples. A thermal imaging camera was used to verify results from the temperature measurement device. We compared the characteristics of heat transfer inside the tissue phantom during moxibustion and laser irradiation. The temperature distribution measured by thermocouples was found to be similar to that of distribution given by thermal imaging camera.