• Title/Summary/Keyword: Surface strength

Search Result 6,025, Processing Time 0.034 seconds

A study on bonding characteristics of SoQ bonding according to surface treatment process conditions (표면처리 공정 조건에 따른 SoQ 접합의 접합 특성에 관한 연구)

  • Kim, Jong-Wan;Song, Eun-Seok;Kim, Yong-Kweon;Baek, Chang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1501_1502
    • /
    • 2009
  • Plasma treatment time was optimized to maximize the bonding strength between silicon and quartz. Bonding strength between the silicon and quartz is related to a surface energy which can be calculated by contact angle measurement. It was found that optimized time to get maximized surface energy was 15 sec. Silicon and quartz wafers were treated with $O_2$ plasma under different time splits and then bonded together. Bonding strength of the bonded wafers was measured by shear test. It was verified that the highest bonding strength was obtained when the silicon and quartz wafers were treated for 15 seconds. The maximum bonding strength exceeded the fracture strength of silicon.

  • PDF

Effect of conjugation of mesogenic core of nematic liquid crystals for polar anchoring strength on rubbed polyimide surfaces (극각 방향의 결합강도에 관한 네마틱 액정의 분자구조 변화의 효과)

  • 서대식
    • Electrical & Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.265-269
    • /
    • 1996
  • We have studied the effect of the mesogenic core of nematic liquid crystals (NLCs) for polar (out-of-plane tilt) anchoring strength and surface order parameter on rubbed polyimide (PI) surfaces. The order of polar anchoring strength for NLCs on rubbed PI surfaces is 5CB > PCH5 > CCH5. From the above results, we suggest that the polar anchoring strength depends on the polarizability of the NLCs. The surface order parameter for NLCs is 5CB > PCH5 > CCH5 on rubbed PI surfaces. We conclude that the polar anchoring strength is strongly related to the surface order parameter on rubbed PI surfaces.

  • PDF

Evaluation of the Adhesion Strength of Metal Spray Coating System in Steel using High-frequency Arc Metal Spray Method (고주파 아크 금속용사기를 이용한 금속용사 코팅계의 부착강도 평가)

  • Choe, Hong-Bok;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.96-97
    • /
    • 2014
  • The purpose of this study is to analyze the adhesion strength of metal spray coating system in steel using high-frequency arc metal spray method. For the purpose the experimental factor such as surface roughness was selected at 3 levels. As a result of experiment, it appeared that high-frequency arc metal spray method had higher adhesion strength than existing metal spray method. Especially, Al-Mg showed the highest adhesion strength than other metals. In case of surface roughness, the higher roughness steel has, the higher adhesion strength appeared.

  • PDF

Effect of Facial Treatment for Resin Teeth on Bonding Strength of Denture (레진치아의 표면처리가 의치상과의 결합강도에 미치는 영향)

  • Kim, Yong-Won
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.71-77
    • /
    • 2008
  • Acrylic resin has been widely used for dental care since it requires relatively simple equipment for treatment and less time and cost are needed to make it and, furthermore, proper strength, dimensional stability as well as durability are ensured after treatment. A survey of denture users showed, however, that more than 60% of dentures installed need repair each year, $22{\sim}30%$ of which are due to falling out of teeth. This study is aimed at exploring the means to increase bonding strength of denture by reducing the causes for falling out of teeth during the processing of dentures. For this aim, the bonding strength of dentures was compares and analyzed before and after the glazed surface of teeth contacting denture was eliminated. From the analysis, it was revealed that there was a difference of 4.3MPa in average in bonding strength between 20MPa for the glazed surface not eliminated and 24.3MPa for the glazed surface eliminated.

  • PDF

Improved Adhesive Strength of Vulcanized Rubber upon Laser Treatments

  • Sohn, Hong-lae;Lee, Bong-Ju
    • Macromolecular Research
    • /
    • v.12 no.5
    • /
    • pp.540-543
    • /
    • 2004
  • Surface treatment using an excimer pulse laser beam has been conducted in order to increase the adhesive strength of vulcanized rubber. The adhesive strength increased with increasing the number of irradiation time with laser pulses and reached to 1,500 N/m after 100 cycles of irradiation. Increased in energy density was directly proportional to the improvement of the adhesive strength. Maximum value of the adhesive strength of 1,500 N/m obtained at the energy density of 176 mJ/$\textrm{cm}^2$. We conclude that an increased energy density improves in both the surface area and adhesive strength.

A study on adhesion strength of electroless plated deposits on Alumina substrate (Alumina substrate 상의 무전해 도금층의 밀착력에 관한 연구)

  • 조용균;안균영;박용수
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.4
    • /
    • pp.187-195
    • /
    • 1991
  • Adhesion strength of electroless-plated Ni, Ni-P and Cu deposites on alumina substrate has been studied. Grain boundary spaces produced on the substrate surface by etching treatment provided anchoring sites for enhancing the adhesion strength. Adhesion strengths of Ni-P and Ni deposit were higher than that of Cu deposit, because of higher initial nucleation rates than the latter. The electroless-plated Ni-P and Ni underlayer improved the adhesion strength of the Cu deposit. In could be attributed to the enhanced adhesion between the substrate and those underlayers as well as the satisfactory adhesion between Cu deposits and those underlayers. Heat treatment was also conducted in order to enhance the adhesion strength of Cu layer. The strength was enhanced by about 19% when the treatment was conducted at $150^{\circ}C$ for 2 hours. The enhancement was attributed to relief of internal stress and release of hydrogen.

  • PDF

Shear bond strength of orthodontic adhesive to amalgam surface using light-cured resin (광중합형 레진으로 아말감 면에 브라켓 접착 시 전단결합강도)

  • Cho, Ji-Young;Lee, Dong-Yul;Lim, Yong-Kyu
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.443-450
    • /
    • 2005
  • This study was performed to compare the shear bond strength of orthodontic adhesive to amalgam according to different light sources (halogen-based light and light emitting diode (LED)) and amalgam surface treatments. Ninety extracted human premolars were randomly divided into 6 groups (4 experimental and 2 control groups) of 15 by light sources and surface treatments. Orthodontic brackets were bonded and shear bond strength was measured with an Instron universal testing machine. The findings were as follows: The bond strength of adhesive to amalgam surface was 3-5.5 MPa which was lower than that of acid-etched enamel (19 MPa) control. In the sandblasted amalgam surface, the shear bond strength of the halogen light group was higher than that of the LED group (p < 0.05) but. in the non-treated amalgam surface. there was no significant difference in the shear bond strength according to the light sources (p> 0.05). Within the same light source. sandblasting had no significant effect on the shear bond strength of the adhesive bonded to amalgam surface (p > 0.05). There was no significant difference in shear bond strength according to the light sources in acid-etched enamel control groups. This results suggest that there can be a limit in using light curing adhesives when brackets are bonded to an amalgam surface. Additional clinical studies are necessary before routine use of halogen light and LED light curing units can be recommended in bonding brackets to an amalgam surface.

A STUDY ON THE SHEAR BOND STRENGTH OF LUTING GLASS IONOMER AND DENTIN TREATED WITH CALCIUM SOLUTION (칼슘수용액으로 처리한 상아질과 합착용 글래스아이오노머의 전단결합강도에 관한 연구)

  • Paik, Young-Girl;Lee, Sung-Bok;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.593-610
    • /
    • 1996
  • The objective of this paper was to evaluate the shear bond strength of luting glass ionomer cement with defferent calcium based solution treatment on dentin surface. 120 extracted human teeth were classified into 12 group based on presence of smear layer on dentin surface and type of treatment solution. Smear layer remove on dentin surface was done using 6% citric acid for 60 seconds. Five different dentin surface treatment solutions(calcium acetate, calcium carbonate, clacium chlorided, calcium hydroxide, and calcium phosphate) were evaluated in this study. After surface modification, metal ring(inner diameter : 3mm, depth : 1mm) was placed to expose the same dentin surface area and inner space was filled with luting glass ionomer cement according to the recommended procedure for stadard clinical procedure. The shear bond strength of glass ionomer cement was determined after 24 hours. SEM was used for the evaluation of the surface morphologic changes and EDAX analysis was done for determination of the change of the calcium contents of treated dentin. Follwing conclusion can be drawn : 1. In the group of the dentin surface with smear layer, the calcium carbonate solution was the most effective for the increase of the clacium content and the shear bond strength of glass ionomer cement to dentin surfaces. 2. In the group of the calcium carbonate treated dentin with msear layer, the shear bond strength was increased twice compared to the control group and cohesive failure mode was observed. 3. The shear bond strength of cement was increased significantly be the removal of smear layer using 6% citric aicd. However, additional calcium solution treatments were not effective for further bond strength increase. 4. The shear bond strength of cement was significantly improved by both of the removal of smear layer and the calcium solution treatment, and the former was more effective for bond strength improvement. 5. The smear layer removed/calcium solution treated groups showed dentinal tubule obstruction and crystal attachment in SEM evaluation. However, the shear bond strengths of these groups were not increased compared to the smear layer removed/no dentin treatment group.

  • PDF

REGIONAL MICRO-SHEAR BOND STRENGTH TO DENTIN:EFFECTS OF DENTINAL HARDNESS, POSITION, AND REMAINING DENTIN THICKNESS (상아질의 경도, 위치 및 잔존 상아질 후경이 상아질에 대한 부위별 미세 전단결합강도에 미치는 영향)

  • Hwang, Seon-Seong;Im, Mi-Kyung;Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.401-412
    • /
    • 1998
  • The aim of this study was to measure the regional micro-shear bond strength of dentin bonding agents to dentin, and to investigate the relationship between the micro-shear bond strength and two dentinal characteristics ; Vickers hardness and remaining dentin thickness. Twenty-four freshly extracted, noncarious human molars were selected for this study. The materials tested in this study consisted of two commercially available dentin bonding agents (MAC-BOND, ONE-STEP) and two restorative light-cured composite resins (AELITEFIL, Z100). The occlusal or side surface of tooth crown was sectioned to expose dentin, and the exposed surface was finally polished with # 600 sandpaper. Four groups of application methods were used combining the filling materials and the dentin bonding agents. The composite resin-attached tooth specimens were embeded in a cold cure acrylic resin, and were cut with a low speed diamond saw to the dimension of 1mm $\times$ 1mm. Nine specimens were obtained from each tooth. The cut specimens were divided into three groups depending on the position of the dentin bonding surface. The micro-shear bond strength, remaining dentin thickness, and dentinal hardness were measured. Experimental results were then statistically analyzed with ANOVA. t-test, Scheffe test, and regression analysis. From this experiment, the following results were obtained : 1. In the case of occlusal surface bonding, the pooled micro-shear bond strength of ONST-AELIT group (16.62 MPa) was significantly higher than that of MACB-AELIT group (9.91 MPa) (p<0.05). However, there was no significant difference in the micro-shear bond strength depending on the dentin position (p>0.05). 2. In the case of side surface bonding of crown, the pooled micro-shear bond strength of four different bonding groups was not significantly different among each other (p>0.05). However, in three of the test groups (ONST-AELIT, MACB-Z100, ONST-Z100), the micro-shear bond strength to the lower 1/3(III) position was significantly lower than that to middle 1/3(II) position of surface (p<0.05). 3. In the ONST-AELIT bonding group, the pooled micro-shear bond strength to the occlusal surface was significantly lower than that to the side surface of crown (p<0.05). 4. There was no significant correlation between the micro-shear bond strength and dentin hardness / remaining dentin thickness (p>0.05).

  • PDF

Frature Toughness Characteristics of Surface-Hardened SM53C Steel by High Frequency Induction (고주파 표면경화퇸 SM53C강의 파괴인성 특성)

  • Park, Won-Jo;Jeon, Hyun-Bae;Hur, Chung-Weon;Kim, Jin-Bum
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.1
    • /
    • pp.12-17
    • /
    • 2008
  • The earn shaft is very important for the safety of automobiles. The earn shaft needs a surface hardening process by high frequency induction to have both strength and toughness. It is required for safety of automobile to consider how the characteristics of tensile strength and toughness are changed according to the condition of surface hardness. In this study, we prepared surface hardened SM53C which is used as cam shaft materials. We examined the tensile strengths according to the depth of surface hardening and the effect of tempering. We also investigated the fracture toughnesses according to the depth of surface hardening(1mm, 2mm).