• Title/Summary/Keyword: Surface skin thickness

Search Result 137, Processing Time 0.024 seconds

The Vasodilator Effect of a Cream Containing 10% Menthol and 15% Methyl Salicylate on Random-Pattern Skin Flaps in Rats

  • Dolen, Utku Can;Sungur, Nezih;Koca, Gokhan;Ertunc, Onur;Bosi, Ayse Tulay Bagci;Kocer, Ugur;Korkmaz, Meliha
    • Archives of Plastic Surgery
    • /
    • v.42 no.6
    • /
    • pp.695-703
    • /
    • 2015
  • Background It is still difficult to prevent partial or full-thickness flap necrosis. In this study, the effects of a cream containing menthol and methyl salicylate on the viability of random-pattern skin flaps were studied. Methods Forty female Sprague-Dawley rats were divided into two equal groups. Caudally based dorsal random-pattern skin flaps were elevated, including the panniculus carnosus. In the study group, 1.5 mL of a cream containing menthol and methyl salicylate was applied to the skin of the flap, and saline solution (0.9%) was used in the control group. Upon completion of the experiment, flap necrosis was analyzed with imaging software and radionuclide scintigraphy. Histopathological measurements were made of the percentage of viable flaps, the number of vessels, and the width of the panniculus carnosus muscle. Results According to the photographic analysis, the mean viable flap surface area in the study group was larger than that in the control group (P=0.004). According to the scintigrams, no change in radioactivity uptake was seen in the study group (P>0.05). However, a significant decrease was observed in the control group (P=0.006). No statistically significant differences were observed between the groups in terms of the percentage of viable flaps, the number of vessels, or the width of the panniculus carnosus muscle (P>0.05). Conclusions Based on these results, it is certain that the cream did not reduce the viability of the flaps. Due to its vasodilatory effect, it can be used as a component of the dressing in reconstructive operations where skin perfusion is compromised.

Verification of skin dose according to the location of tumor in Tomotherapy (토모테라피 시 종양의 위치에 따른 피부선량 검증)

  • Yoon, Bo Reum;Park, Su Yeon;Park, Byoung Suk;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • Purpose : To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. Materials and Methods : In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5mm and 10mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3mm and 5mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. Results : The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5mm and 3mm respectively. If placed 5mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5mm and 3mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2~17.1% whereas if the tumor is 5mm away from the ceiling part, the figure decreased to 2.8~9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment. Conclusion : This study found gaps between planned skin doses and actual doses in the Tomotherapy treatment planning. Especially to the Tomo-cocuh direction, skin doses were found to be larger than the planned doses. Thus, during the treatment of tumors near the Tomo-couch, doses will need to be more accurately calculated and more efforts to verify skin doses will be required as well.

The Method of Thermograph using Thermoelectric Sensor Device in the Carbon fiber Thick Films (Carbon fiber 후막형 열전센서 소자를 이용한 적외선 체열진단)

  • Song, Min-Jong;Dong, Kyung-Rae;Kim, Chang-Bok;Choi, Seong-Kwan;Park, Yong-Soon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Thick films of carbon fiber were prepared by a heating element of plan shape made in Darin co., We have investigated surface morphology of the specimen depending on heat-treatment temperatures. Scanning electron microscope(SEM) image of carbon fiber thick films of the specimen heat treated shows a grain growth at $1200^{\circ}C$ and becomes a poly-crystallization at $1350^{\circ}C$. The variation of resistivity at the thermally annealed specimen above $600^{\circ}C$ depends on type of the substrates. It may be due to a variation of film thickness and a difference of interfacial phenomena. A heating element of features was affected significantly by skin blood and quantity of heat of the body physiological function. After radiation of farinfrared for plate heating element, the function of biometric physiological is considered of skin blood flow and calorie which greatly affects on individuals. Electromagnetic wave was not influence on the body.

  • PDF

A step-by-step intraoperative strategy during one-stage reconstruction of an acute electrical burn injury in the neck for superior surgical outcome in India: a case report

  • Mainak Mallik;Sanjay Kumar Giri;M. Vishnu Swaroop Reddy;Kallol Kumar Das Poddar
    • Journal of Trauma and Injury
    • /
    • v.37 no.2
    • /
    • pp.151-157
    • /
    • 2024
  • Electrical burn injuries can cause more damage than clinical evaluations initially suggest. The energy waves penetrate from the surface to the deepest layers of tissue, causing extensive harm at every level. The neck is a critical area, both functionally and aesthetically. We present a case involving a young male patient with a severe fourth-degree electrical burn on the neck, who underwent a single-stage debridement and reconstructive surgery. The pectoralis major myocutaneous flap is a versatile option for various head and neck reconstructions. However, if the donor site cannot be closed primarily and requires split-thickness skin grafting, it can result in unsightly scars and deformities. For large flap paddles, it is ideal to reconstruct the secondary defect with locoregional flaps. In this case, we successfully reconstructed the donor site's secondary defect using a contralateral internal mammary artery perforator flap, without resorting to any skin grafts. The early postoperative results demonstrated satisfactory cosmesis, patient satisfaction, and functional outcomes.

Two Cases of Auricular Salvage after Wide Excision of Malignant Tumor at Periauricular Area (이개 주변 악성종양의 광범위절제술 후 이개의 보존 2례)

  • Kim, Kyul-Hee;Chung, Chul-Hoon;Chang, Yong-Joon;Lee, Jong-Wook;Rho, Young-Soo;Kim, Chang-Woo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.25 no.1
    • /
    • pp.39-42
    • /
    • 2009
  • Wide excision for curative treatment of malignant tumor on periauricular area often leads to loss of the external ear. But the auricle has rich vascular supply, Conservation of auricular contour is possible through salvage and engineering of remained auricular tissue. We experienced two cases of auricular salvage after wide excision of malignant tumor. In the first case, we performed two-staged technique. In first step, we covered soft tissue defect on periauricualr area with the anterolateral thigh free flap and remained auricle was floating over the flap after split-thickness skin graft was applied on it's posterior raw surface because it's survival was not confirmed. Second step was reposition of remained auricule on the anterolateral thigh flap. In the second case, we packed in periauricular dead space and external auditory canal with temoporalis muscle and temporoparietal fascial flap and then covered the flap with split thickness skin graft. In these two cases, there were no recurrence of tumors and we obtained cosmetically & functionally satisfactory results.

A Study on the Minimization of Tie-plate Loss of Cast Resin Transformer using Surface Impedance Boundary Condition (표면 임피던스 경계조건을 이용한 몰드변압기 Tie-plate 손실 최소화에 관한 연구)

  • Hwang, Sung-Ryul;Shin, Pan Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1334-1340
    • /
    • 2017
  • In this paper, a tie-plate shape is optimized by using the numerical technique to reduce the stray load loss of the tie-plate which is a mechanical structure for assembling and supporting of the transformer core. The eddy current loss of the structure is calculated by an electromagnetic field FEM program and the results are compared with 4 different shapes of tie-plates. Since the thickness of the tie-plate is very thin, and the skin depth is very small, the number of FE elements for 3-D transformer model is too big to solve. So, the surface impedance boundary condition (SIBC) is used to reduce the system matrix size and its computing time. To verify the method a 2.5 MVA 22,900/380V distribution transformer is simulated using one objective function and three design variables with some constraints. The final optimized tie-plate has three slots of 6 mm width and 23 mm gap, and the loss is reduced by 75 %. Consequently, the proposed algorithm seems to be considerably applicable to electric machinery as well as power transformer.

Reconstruction of Full Thickness Ala Defect with Nasolabial Fold and Septal Mucosal Hinge Flap

  • Yoo, Hye Mi;Lee, Kyoung Suk;Kim, Jun Sik;Kim, Nam Gyun
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.3
    • /
    • pp.133-137
    • /
    • 2014
  • Reconstruction of a full-thickness alar defect requires independent blood supplies to the inner and outer surfaces. Because of this, secondary operations are commonly needed for the division of skin flap from its origin. Here, we report a single-stage reconstruction of full-thickness alar defect, which was made possible by the use of a nasolabial island flap and septal mucosal hinge flap. A 49-year-old female had presented with a squamous cell carcinoma of the right ala which was invading through the mucosa. The lesion was excised with a 5-mm free margin through the full-thickness of ala. The lining and cartilage was restored using a septal mucosa hinge flap and a conchal cartilage from the ipsilateral ear. The superficial surface was covered with a nasolabial island flap based on a perforator from the angular artery. The three separate tissue layers were reconstructed as a single subunit, and no secondary operations were necessary. Single-stage reconstruction of the alar subunit was made possible by the use of a nasolabial island flap and septal mucosal hinge flap. Further studies are needed to compare long-term outcomes following single-stage and multi-stage reconstructions.

Macro-and Microstructure of Chinese Cabbage Leaves and Their Texture Measurements (김치제조용 배추의 구조와 조직감 측정에 관한 연구)

  • Lee, Cherl-Ho;Hwang, In-Ju;Kim, Jeong-Kyo
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.742-748
    • /
    • 1988
  • The macro-and microstructure of Chinese cabbage used for Korean Kimchi preparation were examined and the texture characteristics of raw cabbage leaf and salted or blanched leaves were evaluated by cutting test. The length and thickness of leaf stalk increased with the order of pyllotaxis, but the thinning effect of outermost leaves was observed. The microstructure of cut-profile of stalk showed densely compacted vascular systems aligned in the center of stalk and the outer space was filled with large parenchima cells. Due to this structure, characteristic cutting curves were obtained by cutting test, composing three peaks of cutting for inner surface skin, center vascular system and outer surface skin. Salting and blanching increased the cutting force mainly due to the increase of Gutted cell wall number caused by the structure collapse.

  • PDF

Conformal Design of PDMS Mold for Arbitrary Skin Surface with 3D Printing (3D Printing 공정을 이용한 PDMS Mold 제작)

  • Kim, KwangYoon;Park, SukHee;Lee, HanBit;Lee, NakGyu;Yoon, JongHun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2017
  • 3D printing technology has been a great interest in human bio-interfaces and human-like robotics since they require arbitrary and adaptive manufacturing. This research mainly concerns the 3D fabrication of a packed biosensor using elastomeric sheets made of PDMS. It is essential to design the PDMS molding with 3D printing since, in the case of biosensors, it should not only produce a conformal shape depending on an arbitrary skin surface but also guarantee a uniform thickness distribution during solidification in the PDMS prepolymer solution. To satisfy the characteristics of the PDMS molding, such as flexibility in the de-molding and stiffness in the solidification processes, multi-materials have been selectively applied to the PDMS molding design, which has been validated with finite element analyses and compared with the 3D printed molding.

Angiomyoma on Face : A Case Report (안면부에 발생한 혈관근종의 치험례 : 증례보고)

  • Choi, Junho;Chang, Hak
    • Korean Journal of Head & Neck Oncology
    • /
    • v.29 no.2
    • /
    • pp.48-50
    • /
    • 2013
  • Angiomyoma is a rare, benign smooth muscle cell tumor. These tumors may be found anywhere in the body. They frequently occur in the lower extremities except venous type. Angiomyoma in the head and neck area is very rare, and only a few cases have been reported. A 63 year-old male patient visited to outpatient clinic due to size-growing nodule-like lesion in the Lt. alar area. Excisional biopsy was done for diagnosis. The lesion was totally excised with 2 mm safety margin. Frozen biopsy of the lesion was requested, and all resection margins were proved negative. To cover the raw surface, full thickness skin grafting was performed. The graft was harvested from Rt. posterior auricular area. Tie over dressing was applyed on Lt. alar area. The graft was well taken and healed without any complication in both short term and long term follow up periods of 2 weeks, 1 month, 2 months, and 6 months. Donor site completed healed without any complications. The leiomyoma is benign tumor originated from smooth muscle, and it can be classified into solid leiomyoma, angiomyoma, and epithelioid leiomyoma. Especially, the angiomyoma consists of smooth muscle cell and blood vessel, and it is originated from the tunica media of blood vessel. Angiomyoma alone frequently occurs in the lower extremities as solitary painless subcutaneous tumor. Venous type of angiomyoma in the oral cavity was reported in other references, but on the facial surface it may be the first case reported as paper. So this report can be very meaningful.