• Title/Summary/Keyword: Surface shape measurement

Search Result 336, Processing Time 0.028 seconds

Multisensor System Integrating Optical Tactile and F/T Sensors for Determination of Type and Position of 3D Contact Surface (3차원 접촉면의 인식 및 위치의 결정의 위한 광촉각센서와 역각센서의 다중센서시스템)

  • 한헌수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.2
    • /
    • pp.10-19
    • /
    • 1996
  • This paper presents a finger-shaped multisensor system which can measure the tyep and position of a target surface by contactl. The multi-sensor system consists of a sphere-shpaed optical tactile sensor located at the finger tip and a force/torque sensor located at the joint of a finger. The optial tactile sensor determines the type and position of the target surface using the shape and position of the CCD image of the touching area generated by a contact between the sensor and the taget surface. The force/torque sensor also determines the position and surface normal vector by applying the distributionof forces and torques t the contact point to the equations of finger shape. The measurements on the position and surface normal vector at a contact point obtined by two individual sensors are fused using a statistical method. The integrated sensor system has 0.8mm error in position measurement and 1.31$^{\circ}$ error in normal vector measurement. The developed sensor system has many applications, such as autonomous compliance control, automatic grasping and recognition, etc.

  • PDF

A large surface-shape measurement method by using Atomic Force Microscope (원자간력 현미경을 이용한 대면적 표면 형상 측정 방법)

  • Shin Y.H.;Ko M.J.;Hong S.W.;Kwon H.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1543-1546
    • /
    • 2005
  • This paper presents a method to measure a large surface shape using atomic force microscopy, which has been used mostly for measuring over very tiny surfaces. Experiments are performed to measure a step height and a slope of a test sample. The proposed method is rigorously compared with the coordinate measuring machine. The repetition accuracy and the effects of the set point are also studied. The experimental results show that the proposed method is reliable and should be effective to measure both the nano-accuracy surface profile as well as the micro-accuracy global shape of a macro/micro parts using atomic force microscope.

  • PDF

Design of Brassiere Pattern for Big Size Breast Women -Based on 3D Breast Scanning Data- (유방이 큰 여성을 위한 브래지어 패턴 설계 -3차원 유방 형상 자료를 중심으로-)

  • Han, Chohee;Yi, Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.2
    • /
    • pp.204-214
    • /
    • 2019
  • A CAD program has recently been introduced that can be directly developed into a three-dimensional human body shape and made into a pattern. It is possible to fabricate a bra that reflects the volume and surface area of the breast; however, it still needs to be verified. This study investigates the average size and shape of 20 big-breasted women and designs a brassiere pattern for women with large breasts using a 3D Flattening function of OptiTex PDS v15.6. In addition, the study verifies the reliability of the proposed method compared to a conventional brassiere pattern. The study results are as follows. First, the three dimensional measurement values were smaller than the direct measurement dimensions when the three dimension measurement dimensions of the subjects were compared with the direct measurement dimensions, the replica measurement dimensions and the three dimensional measurement dimensions. Second, the 3D flattening pattern reflects the actual shape, length, and area of the actual breast when comparing a brassiere pattern using a 3D shape and pattern reflecting the direct measurement.

Optical Performance Degradation Effects by Fabrication Errors of Circular-type Computer Generated Holograms

  • Kim, Young-Gwang;Rhee, Hyug-Gyo;Ghim, Young-Sik
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1657-1662
    • /
    • 2018
  • A null test method which relies on a computer generated hologram (CGH) is widely used to measure a large aspheric surface. For precise measurements of the surface shape of an aspheric optics, the CGH must precisely generate a wavefront that can fit on the ideal surface shape of the aspheric optics. If fabrication errors arise in the CGH, an unwanted wavefront will be generated and the measuring result will lack trustworthiness. Thus far, there has been limited research on wavefronts generated by CGH using only linear-type binary grating models. In this study, a theoretical error model of a circular-type zone plate, the most commonly used types for CGH patterns, is suggested. The proposed error model is checked by simulations and experiments.

A curvature profilometry using white-light (백색광을 이용한 곡률 측정법 개발)

  • Kim, Byoung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.3
    • /
    • pp.81-86
    • /
    • 2008
  • I present a 3-D profiler specially devised for the profile measurement of specular surfaces that requires precision shape accuracy up to a few nanometer. A profile is reconstructed from the curvature of a test part of the surface at several locations along a line. The local curvature data are acquired with White-light Scanning Interferometry. Test measurement proves that the proposed profiler is well suited for the specular surface inspection like precision mirror.

  • PDF

A Study on the Improvement of Accuracy and Precision in the Vision-Based Surface-Strain Measurement (비전을 이용한 곡면변형률 측정의 정확도 및 정밀도 향상에 관한 연구)

  • 김두수;김형종
    • Transactions of Materials Processing
    • /
    • v.8 no.3
    • /
    • pp.294-305
    • /
    • 1999
  • A vision-based surface-strain measurement system has been still improved since the authors devel-oped the first version of it. New algorithms for the subpixel measurement and surface smoothing are introduced to improve the accuracy and precision in the present study. The effects of these algorithms are investigated by error analysis. And the equations required to calculate 3D surface-strain of a shell element are derived from the shape function of a linear solid finite-element. The influences of external factors on the measurement error are also examined, and several trials are made to obtain possible optimal condition which may minimize the error.

  • PDF

Noncontact 3-dimensional measurement using He-Ne laser and CCD camera (He-Ne 레이저와 CCD 카메라를 이용한 비접촉 3차원 측정)

  • Kim, Bong-chae;Jeon, Byung-cheol;Kim, Jae-do
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1862-1870
    • /
    • 1997
  • A fast and precise technique to measure 3-dimensional coordinates of an object is proposed. It is essential to take the 3-dimensional measurements of the object in design and inspection. Using this developed system a surface model of a complex shape can be constructed. 3-dimensional world coordinates are projected onto a camera plane by the perspective transformation, which plays an important role in this measurement system. According to the shape of the object two measuring methods are proposed. One is rotation of an object and the other is translation of measuring unit. Measuring speed depending on image processing time is obtained as 200 points per second. Measurement resolution i sexperimented by two parameters among others; the angle between the laser beam plane and the camera, and the distance between the camera and the object. As a result of these experiments, it was found that measurement resolution ranges from 0.3mm to 1.0mm. This constructed surface model could be used in manufacturing tools such as rapid prototyping machine.

Analysis of Measuring Error of Surface Roughness by Contact Stylus Profilometer (촉침에 의한 표면 거칠기 측정 오차 해석)

  • Cho, Nahm-Gyoo;Kwon, Ki-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.12
    • /
    • pp.174-181
    • /
    • 1999
  • This paper describes the effect of the stylus tip size on the shape error in surface topography measurement. To analyze the distortional effect of an actual surface geometry origination from the finite stylus size, the surface is modeled as a sinusoid and the stylus tip as a circle. The magnitude of this distortion is defined as the ration of standard deviation, and this is expressed as an analytic function of the stylus tip radius and the geometrical parameter of a sinusoid. In this paper, the spectrum analysis of the profile is applied to investigate the distortional effect due to the mechanical filtering of the stylus in the frequency domain. and, the cumulative power spectrum is proposed to assess the shape error of measured data according to the various stylus tip sizes. From these results, a new method to select proper stylus tip radius is proposed.

  • PDF

Effect of Surface Roughness of Rheometer on the Slip Phenomenon in the Viscosity Measurement of PIM Feedstock (분말사출재의 점도 측정 시 측정기 표면 조도가 미끄럼 현상에 미치는 영향)

  • 이병옥;민상준
    • Journal of Powder Materials
    • /
    • v.9 no.4
    • /
    • pp.251-260
    • /
    • 2002
  • In the viscosity measurement of PIM feedstock, slip correction methods require a number of experiments and produce a high level of error. In this study, a rotational rheometer with a parallel-discs configuration having different surface roughness was tried to minimize the effect of the slip phenomenon. Disc surface was prepared in 3 different roughness conditions - a smooth and 2 roughened surfaces. Results with the roughened surfaces were compared with the results obtained with a slip correction method. Relationship between powder characteristics such as size and shape and a surface roughness of the disc was examined for feedstock of 4 different powders with a same binder. As results, the effect of the slip phenomenon could be sufficiently minimized on the roughened surface in most cases. However, the effect of the slip phenomenon could not be sufficiently minimized for feedstock of a round-particular-shape powder and in the case of very narrow gap size.

A Study on the surface and analysis of phase map using optical interferometer (광 간섭계를 이용한 표면 및 위상지도 분석에 관한 연구)

  • Park, June-Do;Shin, Soo-Yong;HwangBo, Seung;Kang, Yong-Chel
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.436-437
    • /
    • 2005
  • 3-dimension object's feature measurement is used several industrial field to produce for examination of demanded high quality products by using optical measurement method. 3-dimension object's feature measurement is separated surface scanning and surface non-scanning. In this research, we illuminated interfero-pattern to object, it was constructed with Michelson interferometer by using laser is one of surface non-scanning method. And we extracted phase-map, it is one of featural measurement analysis of 3-dimensional object by using a phase shifting theory.

  • PDF