Journal of the Korean Society of Propulsion Engineers
/
v.16
no.4
/
pp.80-86
/
2012
This study is for figuring out a possibility of realization of the thermal protection system(TPS) for temporary use under high temperature condition and improving a design of the future TPS. On this purpose, environmental condition of the system has been simplified: the boundary conditions consist of a internally heating surface and a externally heated surface which is simulating the external high temperature condition. Configuration of the system is simplified as a hexahedon. Melting characteristics of the phase change material(PCM) and air temperature variation of TPS with or without connector have been numerically analyzed and compared. As a result of numerical analysis, the heat from the internally heated surface could not be effectively transferred. Therefore, temperature of inner space has been increased.
Bekesy measured the sound transformation system of the middle ear 49 years ago. According to his reports, a ratio between the size of ear drum and the size of oval window is 17 : 1, and the lever function of the ossicles is physiologically 1.3 : 1. Therefore, the hearing might be aggravated to 27.5㏈ in the case of the vanishment of 3 ossicles. In 1952, Wullstein reported 5 types of tympanop-lasty and the fourth type among them was especially named for the sound-protection. The oval window is only exposed by the sound pressure and the round window is not exposed. According to the application by this idea, the post-operative hearing might be improved until 27.5㏈. Mean while, in 1942, Onchi verified through his experiment that the results of Bekesy's measurement was not completely conformed to Onchi result. Bekesy measured the sound pressure on the stapes plate of the oval window, on the other hand, Onchi measured the sound pressure on the surface of the perilymph of the oval window after removing the stapes plate(Fig. 1).(Figure omitted) The difference of their experiment is recognized that the impedance of the stapes plate exists or not (Fig. 1). Both Audiogrums are compared as Fig. 2. The result of IV type of tympanoplasty is success ful in 54% as the Table 1. (Table Omitted) The reason of unsatisfactory is caused by the thick and unmovable window-membrane and by the closing of air passage to the round window. The closing of the air passage to the round window is occurred by the adhesion between the grafting membrane and the surface of promontorium. In order to preserve this adhesion, I produce to transplantate the mucous membrane of the lip to the bone surface of tympanic cavity after removing the granulation tissue of the tympanic cavity and to form a membranous canal for the sake of air passage (Fig. 3). (Figure Omitted) The post-operative hearing by this method is shown as Fig. 4, 5. In other words, the post-operative sound pressure entered into the cochlea directly, by way of the oval window only, not by way of the round window, as a theorie of the sound protection. (Figure omitted)
Journal of the Korea Institute of Information Security & Cryptology
/
v.33
no.6
/
pp.939-946
/
2023
In the hyper-connected network, which network equipment is diverse and network structure is complex, the attack surface has also increased. In this environment, MTD(Moving Target Defense) technology is being researched as a method to fundamentally defend against cyber attacks by actively changing the attack surface. network-based MTD technologies are being widely studied. However, in order for network address mutation technology to be applied within the existing fixed IP-based system, research is needed to determine what impact it will have. In this paper, we studied the impact of applying network address mutation technology to the existing network protection system. As a result of the study, factors to be considered when firewall, NAC, IPS, and network address mutation technologies are operated together were derived, and elements that must be managed in network address mutation technology for interoperability with the network analysis system were suggested.
Transactions of the Korean Society of Mechanical Engineers A
/
v.28
no.9
/
pp.1384-1390
/
2004
The full containment Liquefied Natural Gas(LNG) storage tank is based on a double liquid container concept : two separate containers, one within the other, are capable of containing the LNG. The outer concrete tank provides comer protection(secondary containment) to withstand and safely contain any spill from the inner tank. The comer protection is installed on inside corner surface of outer concrete tank. Because of high and complex stresses, corner protection is designed by ASME section ⅧI Div. 2, Appendix 4 on behalf of API 620 which is main design code for LNG tank. Design guidelines to determine design factors such as liner thickness and knuckle radius are not well understood because Appendix 4 is the design method not based on equation but FEM. Recently, the volume of LNG tank shows a tendency to increase. So it is necessary to set up the design guidelines to cope with change of LNG tank capacity and height/diameter ratio. In this paper, optimum design of corner protection was performed and the design guidelines were suggested by the results of FEM for LNG tanks which have different capacities and height/diameter ratio.
To investigate removal effects of nutrients in stormwater runoff by soil of riparian protection zone, soil column experiment was conducted for 20 months. Artificial stormwater runoff containing phosphate and nitrate was applied on the surface of soil column twice a week, and phosphate and nitrate concentrations were measured from the leached water. Soil of riparian protection zone reduced the released amount of infiltrated water to the surrounding water. After infiltration of 1m depth of soil column, average removal rates of phosphate and nitrate were 97.7 % and 74.7 %, respectively. As main mechanisms of phosphate are adsorption to soil particle and utilization by plants, periodical replacement of soil and harvesting of plant at the end of growing season are required. For the removal of nutrients in stormwater runoff by the soil layer, soil of riparian protection zone has higher hydraulic conductivity to infiltrate stormwater. Sandy soil having hydraulic conductivity of about $1{\times}10^{-2}cm/s$ range might be appropriate for this purpose.
This study surveys the surface water environment in Southwest sea areas of Vietnam in order to evaluate the current environment. It collects and analyzes experimental results of programs, scientific subjects, and international projects relevant to ecological areas and coastlines of Kien Giang province. The methods analyzed and discussed by specialists are evaluated according to pollution coefficients established by the World Health Organization (WHO), sampling methods, and case study analyses. Comparison between the scale of pollution levels and the surface water quality in experimental areas of Long Xuyen Quadrangle shows a light-moderate pollution level. In Ca Mau Peninsula, the surface water source is only slightly polluted. Sea areas and islands are also light-moderately polluted. Computing results from water quality indices (WQI) show the level of pollution in experimental sites. Activities such as constructing infrastructures for tourism, exploiting minerals, and increasing population accelerate environmental pollution by deteriorating inherently sensitive ecosystems like corals, sea grass, mangrove swamps, and Melaleuca forests. Surveying and evaluating the present situation of surface water are fundamental solutions for environmental protection in the Southwest sea areas of Vietnam.
Proceedings of the Computational Structural Engineering Institute Conference
/
2002.04a
/
pp.395-400
/
2002
Epoxy coating and sealing used in nuclear plants for the protection of radiation degrades with aging and hazardous atmosphere. In order to evaluate the degradation of the epoxy, dependence of the acoustic impedance on the change of mechanical properties has been used. Unlike metals, the surface of the epoxy coating on a concrete liner is so wavy that the acoustic impedance is difficult to measure by using the reflectivity of the ultrasound on the interface surface because of the irregular reflection and propagation from the epoxy surface. SA(simulated annealing) algorithm is applied to calculate the acoustic impedance using a reflection wave from the rough epoxy surface. The surface waviness and acoustic impedance are taken into account and determined by SA method to evaluate the state of degradation quantitatively.
Korean Journal of Air-Conditioning and Refrigeration Engineering
/
v.24
no.4
/
pp.323-329
/
2012
In this study, a rational procedures for estimation of insulation thickness of a vertical wall for condensation control or personnel protection has been investigated. Design parameters are height of the wall, thermal conductivity, emissivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation for the purpose of surface temperature control, especially in natural convection situation. radiation heat transfer coefficients for some new insulation material surface, such as elastomers, estimated to be more than 90% of the total surface heat transfer coefficient.
Jung, Haechang;Kim, Wang Ryeol;Jeong, Chanyoung;Lee, Junghoon
Journal of Surface Science and Engineering
/
v.52
no.1
/
pp.37-42
/
2019
Electrodeposited zinc layer is widely used as a sacrificial anode for a corrosion protection of steel. In this study, we modified the surface of electrodeposited zinc to have a hydrophobicity, which shows various advanced functionalities, such as anti-corrosion, anti-biofouling, anti-icing and self-cleaning, due to its repellency to liquids. Superhydrophobicity was realized on electrodeposited zinc layer with a hydrothermal treatment, creating nanostructures on the surface, and following Teflon coating. The superhydrophobic surface shows a great repellency to water with high surface tension, while liquid droplets with low surface tension easily adhered on the superhydrophobic surface. However, immiscible lubricant-impregnated superhydrophobic surface shows a great repellency to various liquids, regardless of their surface tension. Therefore, it is expected that the lubricant-impregnated surface can be an alternative of superhydrophobic surface, which have a drawback for some liquids with a low surface tension.
Prestressed Concrete steel Cylinder Pipe (PCCP) is extensively used as seawater pipes for cooling in nuclear power plants. The internal surface of PCCP is exposed to seawater, while the external surface is in direct contact with underground soil. Therefore, materials and strategies that would reduce the corrosion of its cylindrical steel body and external steel wiring need to be employed. To prevent against the failure of PCCP, operators provided a cathodic protection to the pre-stressing wires. The efficiency of cathodic protection is governed by the anodic performance of the system. A mixed metal oxide (MMO) electrode was developed to meet criteria of low over potential and high corrosion resistance. Increasing coating cycles improved the performance of the anode, but cycling should be minimized due to high materials cost. In this work, the effects of $RuCl_3$ concentration on the electrochemical properties and lifespan of MMO anode were evaluated. With increasing concentration of $RuCl_3$, the oxygen evolution potential lowered and polarization resistance were also reduced but demonstrated an increase in passive current density and oxygen evolution current density. To improve the electrochemical properties of the MMO anode, $RuCl_3$ concentration was increased. As a result, the number of required coating cycles were reduced substantially and the MMO anode achieved an excellent lifespan of over 80 years. Thus, we concluded that the relationship between $RuCl_3$ concentration and coating cycles can be summarized as follows: No. of coating cycle = 0.48*[$RuCl_3$ concentration, $M]^{-0.97}$.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.