• Title/Summary/Keyword: Surface ozone

Search Result 369, Processing Time 0.026 seconds

Characteristics of Diurnal Variation of the Atmospheric Pollutants Concentration in High-Ozone Episode day in Daegu (대구시 고농도 오존 사례일인 경우 대기 오염물질 농도의 일변화 특성)

  • 손임영;윤일희;김희종
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1253-1259
    • /
    • 2002
  • This study analyzes the surface ozone, NO and $NO_2$ concentration data from 1997 to 1999 in Daegu. It investigates effect on precursor during high-ozone episode days. The high-ozone episode is defined when a daily maximum ozone concentration is higher than 100 ppb(ambient air quality standard of Korea) in at least one station among six air quality monitoring stations. The frequency of episodes is 13 days(33 hours). The frequency is the highest in May and September, and the area with the highest frequency is Nowondong and Manchondong. The average value of daily maximum ozone concentration with high ozone episode is 81.6 ppb, and that of 8-hour average ozone concentration is 58.6 ppb. It means that ozone pollution is continuous and wide-ranging in Daegu. The daily variation of NO, $NO_2$ and $O_3$ in high-ozone episodes are inversely proportional one another. Nowondong an industrial area, is affected by pollutants that are emitted from the primary sources, while Manchondong a residential area, is affected by the advection of $O_3$ or by the primary pollutants like VOCs.

Ozone Generation Characteristics by Surface-Silent Discharge According to the Length of Coaxial Electrode (동축형 전극길이 변화시의 연면무성방전에 의한 오존발생특성(I))

  • Jo, Guk-Hui;Kim, Yeong-Bae;Seo, Gil-Su;Lee, Hyeong-Ho;Lee, Sang-Geun;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.791-797
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects of ozone. In this paper the concentration, yield and generation quantity of the ozone by the Surface-Silent Discharge According to the Length of Coaxial Electrode is described. The electrodes composed of 3 electrodes-2 gaps are coaxial type and the ozone generation tube were designed and fabricated from the point of view of the energy efficiency, stability and easy control. To investigate the ozone generation dependency on electrode length, a few discharge tubes with different lengths were fabricated. The experimental equipments were provided with cooling system and dehumidifier for the many testing conditions. The main results show that the concentration, yield and generation quantity of ozone are improved by decreasing gas temperatures and increasing electrode lengths.

  • PDF

Characteristics of the surface ozone concentration on the occurrence of air mass thunderstorm (기단성 뇌우 발생시 지표오존농도의 변화 특성)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.419-426
    • /
    • 2003
  • This study was performed to research ozone concentration related to airmass thunderstorm using 12 years meteorological data(1990~2001) at Busan. The occurrence frequency of thunderstorm during 12 years was 156 days(annual mean 13days). The airmass thunderstorm frequency was 14 days, most of those occurrence at summertime(59%). In case August 4, 1996, increase of ozone concentration was simultaneous with the decrease of temperature and increase of relative humidity, In case July 23, 1997, ozone concentration of western site at Busan increased, while its of eastern site decreased as airmass thunderstorm occurred(about 1500LST). It is supposed that these ozone increases are the effect of ozone rich air that is brought down by cumulus downdrafts from height levels where the ozone mixing ratio is larger. Thunderstorms can cause downward transport of ozone from the reservoir layer in the upper troposphere into planeta교 boundary layer(PBL). This complex interaction of source and sink processes can result in large variability fer vertical and horizontal ozone distributions. Thus a variety of meteorological precesses can act to enhance vertical mixing between the earth's surface and the atmospheric in the manner described fer thunderstorm.

Characteristics of Ozone Advection in Vertical Observation Analysis Around Complex Coastal Area (연직관측자료를 통한 복잡 연안지역의 오존 이류특성)

  • Lee, Hwa-Woon;Park, Soon-Young;Lee, Soon-Hwan;Leem, Heon-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.1
    • /
    • pp.57-74
    • /
    • 2009
  • In order to clarify the vertical ozone distribution in planetary boundary layer of coastal area with complex terrain, an observation campaign was carried out around Gwangyang Bay with dense pollutant emission sources during two days from June, 4 2007. For this observation are Radiosonde, SODAR(SOnic Detection And Ranging) and Tethered ozone sonde were employed. The surface meteorological and photochemical observation data provided by AWS (Automatic Weather System) and AQMS (Air Quality Monitoring System) were also applied for analysis. Synoptic condition is strongly associated with lower level ozone distribution in complex terrain coastal area. Since mesoscale circulation induced by difference of characteristics of land and sea and orographic forcing is predominant under calm synoptic condition, vertical distribution of ozone is complicate and vertical ozone concentration greatly fluctuated. However in second day when synoptic influence become strong, ozone concentration in lower levels is vertically uniform regardless of observation level. This results in vertical observation indicates that vertical ozone distribution is often determined by synoptic condition and also affects surface ozone concentration.

The Characteristics of Temporal and Spatial Distribution of Surface Ozone Concentration in Jeju Island (제주지역 지표 오존 농도의 시.공간적 분포 특성)

  • Lee, Gi Ho;Kim, Dae Jun;Heo, Cheol Gu
    • Journal of Environmental Science International
    • /
    • v.13 no.4
    • /
    • pp.377-387
    • /
    • 2004
  • This study has been performed to clarify the characteristics of temporal and spatial distribution of surface ozone concentration over Jeju Island, one of the cleanest areas in Korea with low emissions of air pollutants. Ozone data are monitored at four sites in Jeju Island. These monitoring sites are located at two urban area(referred to Ido and Donghong), coastal area(Gosan site) and forest site(Chuna site). Ozone data has been routinely collected at these sites for the late four years. The patterns of seasonal cycle of ozone concentrations at all stations show the bimodal with the peaks on spring and autumn and a significant summer minimum. However, the patterns of diurnal variations at rural station, i.e., Gosan and Chuna sites are considerably different to those at urban stations such as Ido and Donghong sites. The patterns of $\DeltaO_3$ variations are very similar with those of monthly mean ozone concentrations and $\DeltaO_3$ values are exceeded 30 ppb, at urban stations. This may be that urban stations are more influenced by local photochemical reactions rather than rural stations. In order to assess the potential roles of meteorological parameters on ozone formation, the meteorological parameters, such as radiation, temperature, and wind are monitored together with ozone concentrations at all stations. The relationships of meteorological parameters to the corresponding ozone concentration are found to be insignificant in Jeju Island. However, at Gosan and Donghong stations, when the sea breeze blew toward the station, the ozone concentration is considerably increased.

Effects of UV and Ozone on the Weathershed for Polymer Insulators (폴리머애자 갓 재료에 미치는 자외선 및 오존의 영향)

  • 이병성;한재홍;한용희;한상옥;윤여숭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.63-66
    • /
    • 1999
  • The effects of UV and ozone on the weathershed materials for 5 polymer insulators were investigated. This study was carried by material characterizations such as surface microstructure, thermal property, chemical structure and contact angle. The aged specimens are compared with new ones. In case of UV, the chalking of fillers and cracking of surface were increased with the increase of UV radiation time. In case of ozone, aged specimens are not different from new ones. From this study, It can be concluded that UV has more effect on the surface properties of weathershed materials than ozone.

  • PDF

Numerical Simulation of Ozone using UAM-V on Summer Episode in the Costal Urban Area, Busan (UAM-V를 이용한 부산지역 고농도 오존사례 수치모의)

  • 김유근;오인보;황미경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.1-11
    • /
    • 2003
  • Temporal and horizontal distributions of surface ozone concentrations covering the Busan metropolitan area were simulated by UAM -V (The Variable grid Urban Airshed Model) that was run with meteorological inputs taken from MM5 for ozone episode day (18 July 1999). UAM-V underestimated the daily maximum ozone con-centration about 14 ppb on average at all monitoring sites within Busan area comparing with observed value. but the correlation between observed and simulated values showed quite significant (R = 0.896, p< 0.01 on average). Higher concentrations of ozone occurred near the city center and industrial areas (western side of city) with high levels of anthropogenic source in the morning, and transport of ozone and its precursors by sea breeze developed in the afternoon contributed to elevated ozone levels in downwind rural areas. Particalarly in slightly downwind area of city center, the highest daily maximum ozone concentration ($\geq$120 ppb) was simulated by UAM-V at 1400 LST. Consequently, local environments including emission distributions and land -sea breeze circulation influenced ozone distributions in the Busan metropolitan area.

Characteristics on Variation of Temperature and Ozone Concentration during the Partial Solar Eclipse Event of 22 July 2009 at Busan (2009년 7월 22일 부분일식 발생 시 부산지역 기온과 오존농도의 변화 특성)

  • Jeon, Byung-Il;Oh, In-Bo
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.1049-1059
    • /
    • 2011
  • This paper examines the effects of the partial solar eclipse of 22 July 2009 across the Korean peninsular on surface temperature and ozone concentrations in over the Busan metropolitan region (BMR). The observed data in the BMR demonstrated that the solar eclipse phenomenon clearly affects the surface ozone concentration as well as the air temperature. The decrease in temperature ranging from 1.2 to $5.4^{\circ}C$ was observed at 11 meteorological sites during the eclipse as a consequence of the solar radiation decrease. A large temperature drop exceeding $4^{\circ}C$ was observed at most area (8 sites) of the BMR. Significant ozone drop (18~29 ppb) was also observed during the eclipse mainly due to the decreased efficiency of the photochemical ozone formation. The ozone concentration started to decrease at approximately 1 to 2 hours after the event and reached its minimum value for a half hour to 2 hours after maximum eclipse. The rate of ozone fall ranged between 0.18 and 0.49 ppb/min. The comparison between ozone measurements and the expected values derived from the fitted curve analysis showed that the maximum drop in ozone concentrations occurred at noon or 1 PM and was pronounced at industrial areas.

A Study on the Characteristics of the High Concentration Ozone Generator for the Semiconductor Wafer Cleaning with the Ozone Dissolved De-ionized Water (반도체 웨이퍼의 오존 수(水) 세정을 위한 고농도 오존발생장치 특성 연구)

  • 손영수;함상용;문세호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.579-585
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DI-O3 water) in semiconductor wet cleaning process to replace the conventional RCA methods has been studied. In this paper, we propose the water-electrode type ozone generator which has the ozone gas characteristics of the high concentration and high purity to produce the high concentration DI-O3 water for the silicon wafer surface cleaning process. The ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. We investigate the performance of the proposed ozone generator which has the design goal of the concentration of 7[wt%] and ozone generation quantity of 6[g/hr] at flow rate of 1[$\ell$/min). The experiment results show that the water electrode type ozone generator has the characteristics of 8.48[wt%] of concentration, 8.08[g/hr] of generation quantity and 76.2[g/kWh] of yield and it's possible to use the proposed ozone generator for the DI-O3 water cleaning process of silicon wafer surface.

Surface Ozone Episode Due to Stratosphere-Troposphere Exchange and Free Troposphere-Boundary Layer Exchange in Busan During Asian Dust Events

  • Moon, Y.S.;Kim, Y.K.;K. Strong;Kim, S.H.;Lim, Y.K.;Oh, I.B.;Song, S.K.
    • Journal of Environmental Science International
    • /
    • v.11 no.5
    • /
    • pp.419-436
    • /
    • 2002
  • The current paper reports on the enhancement of O$_3$, CO, NO$_2$, and aerosols during the Asian dust event that occurred over Korea on 1 May 1999. To confirm the origin and net flux of the O$_3$, CO, NO$_2$, and aerosols, the meteorological parameters of the weather conditions were investigated using Mesoscale Meteorological Model 5(MM5) and the TOMS total ozone and aerosol index, the back trajectory was identified using the Hybrid Single-Particle Lagrangian Integrated Trajectory Model(HYSPLIT), and the ozone and ozone precursor concentrations were determined using the Urban Ashed Model(UAM). In the presence of sufficiently large concentrations of NO$\sub$x/, the oxidation of CO led to O$_3$ formation with OH, HO$_2$, NO, and NO$_2$ acting as catalysts. The sudden enhancement of O$_3$, CO, NO$_2$ and aerosols was also found to be associated with a deepening cut-off low connected with a surface cyclone and surface anticyclone located to the south of Korea during the Asian dust event. The wave pattern of the upper trough/cut-off low and total ozone level remained stationary when they came into contact with a surface cyclone during the Asian dust event. A typical example of a stratosphere-troposphere exchange(STE) of ozone was demonstrated by tropopause folding due to the jet stream. As such, the secondary maxima of ozone above 80 ppbv that occurred at night in Busan, Korea on 1 May 2001 were considered to result from vertical mixing and advection from a free troposphere-boundary layer exchange in connection with an STE in the upper troposphere. Whereas the sudden enhancement of ozone above 100 ppbv during the day was explained by the catalytic reaction of ozone precursors and transport of ozone from a slow-moving anticyclone area that included a high level of ozone and its precursors coming from China to the south of Korea. The aerosols identified in the free troposphere over Busan, Korea on 1 May 1999 originated from the Taklamakan and Gobi deserts across the Yellow River. In particular, the 1000m profile indicated that the source of the air parcels was from an anticyclone located to the south of Korea. The net flux due to the first invasion of ozone between 0000 LST and 0600 LST on 1 May 1999 agreed with the observed ground-based background concentration of ozone. From 0600 LST to 1200 LST, the net flux of the second invasion of ozone was twice as much as the day before. In this case, a change in the horizontal wind direction may have been responsible for the ozone increase.