• Title/Summary/Keyword: Surface ozone

검색결과 369건 처리시간 0.025초

이종방전 중첩에 의한 방전 플라스마반응기의 효율개선의 시도 - 연면.직류코로나 방전 중첩형 반응기의 특성 - (A Trial for Improvement of Energy Efficiency of Plasma Reactor by Superposing Two Heterogeneous Discharges - Characteristics of Surface and Corona Discharge Combined Plasma Reactor -)

  • 우인성;;황명환
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.66-70
    • /
    • 2000
  • In order to cope with environmental problems caused by harmful gases emitted from various industrial sources, a new technology which employs discharge plasma formed in ordinary atmospheric pressure has been intensively investigated in many industrialized nations. Although a plenty of useful outcomes and suggestions have been made public by scientists in this field, few commercial products which effectively decompose pollutant gases have appeared as yet. This is partly because that the energy efficiency of a most effective plasma reactor has not reached a satisfactory level in comparison with those of devices using conventional technologies. In an attempt to solve the problem mentioned above, we noticed to combine heterogeneous electrical discharges. This concepts is based on that each plasma reactor has its specific spatial region in which chemical reaction are active and by electrically affected with another reactor of different type, the activated region would increase - which may lead to cutting down the energy consumption. To prove this concept experimentally, two different discharge equipments, a plane ceramic-based surface discharge electrode and a corona electrode with tungsten needle may, are selected and combined to fabricate a hybrid plasma reactor. The results are summarized as follows; (1) Ozone concentration generated in the plasma region drastically increases when the positive corona discharge is added to the surface discharge. The rate of increase of ozone depends on the frequency of the surface discharge. The negative corona, however, does not contribute to the improvement of the ozone generation. (2) NO(nitrogen monoxide) decomposition rate also improves by simultaneously applying the surface and the positive corona discharges. The effect of the corona superposition is more evident when the level of the surface discharge is moderate. (3) By adjusting the corona level, the net energy efficiency during NO decomposition improves in comparison with the simple surface discharge reactor.

  • PDF

제주도 고산지역 자외선복사의 월변화 특성과 원인 고찰 (A Study on the Monthly Characteristics of Solar UV Radiation in Gosan, Jeju)

  • 김영아;최우갑
    • 대기
    • /
    • 제27권3호
    • /
    • pp.291-300
    • /
    • 2017
  • The monthly-mean irradiance of ultra violet (UV)-B and UV-A observed from 2005 to 2014 and 2012 to 2014, respectively, at noon in Gosan, Jeju, South Korea are analyzed. We compare cloudiness, total ozone, visibility, and relative humidity with an emphasis on the four months from May to August (MJJA), which shows the largest UV radiation. While the incoming UV-B radiation at the top of the atmosphere in Gosan is the largest in June due to the small solar zenith angle, the observed surface UV-B shows an unexpected smaller value in June than those in May, July or August. In June, the meteorological conditions affecting Gosan are completely dominated by cloudiness and thus, frequent overcast seems to determine the minimum UV-B. Another important UV-determining factor is the total ozone, which exhibits a monotonic decrease during MJJA without agreeing to the characteristic feature of UV. The ratio of UV-B to UV-A is not generally influenced by cloudiness. Thus, the ratio is a useful indicator of atmospheric turbidity showing larger values for increasing visibility, except in June. A simple model has been used to estimate surface UV by using the observed ozone and visibility in the cloudless condition. The result shows that UV has the lowest value in June with small variation during MJJA. Model estimation also shows that the different characteristic features observed in July between surface UV-B and UV-A is the result of less absorption of UV-B by ozone than that of UV-A by a smaller amount of total ozone.

경제적이고 효과적인 경피 약물전달을 위한 3차원 구조의 코팅 고분자 마이크로니들 (3-Dimensional Coating Polymer Microneedles for Economical and Efficient Transdermal Drug Delivery)

  • 이한솔;박정환
    • 폴리머
    • /
    • 제38권3호
    • /
    • pp.391-396
    • /
    • 2014
  • 고분자 마이크로니들은 몰딩 공정으로 쉽고 저렴하게 생산할 수 있지만 3차원 고분자 마이크로 구조체에 수용액 기반의 약물 코팅은 어려움이 있다. 2차원 형태의 평면 금속 마이크로니들에 약물을 코팅한 기존의 코팅 마이크로니들과 비교하여 볼 때 3차원 구조의 고분자 마이크로니들은 코팅 면적이 2배 넓고 단위면적당 마이크로니들의 수를 크게 증가시킴으로써 두 배 이상의 약물을 경피를 통해 전달할 수 있다. 증점제와 계면활성제 첨가 방법의 경우 2차원의 평면에는 균일한 코팅을 얻을 수 있었지만 3차원 구조의 고분자 마이크로니들 표면에서는 만족할 코팅을 얻지 못했다. 하지만, 고분자 마이크로니들 표면을 금속 코팅 혹은 UV/ozone으로 처리한 경우 3차원의 마이크로 니들 표면에 만족할 코팅을 얻을 수 있었으나 금속 코팅의 경우 피부에 찌르고 제거하는 과정에서 금속이 피부 안에 남는 안전성 문제가 있어 UV/ozone을 최종 표면 처리 방법으로 선정하였다. 이렇게 처리한 고분자 마이크로니들 표면에 calcein이 첨가된 코팅물질로 코팅된 마이크로니들은 15분 이상의 피부 투여로 코팅물질을 성공적으로 진피층까지 전달할 수 있었다.

Methodology to Simultaneously Optimize the Inlet Ozone Concentration to Oxidize NO and Relative Humidity Composition for the $NO_x$ Degradation using Soil Bio-filter

  • Cho, Ki-Chul;Hwang, Kyung-Chul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제24권E2호
    • /
    • pp.83-91
    • /
    • 2008
  • This work investigated the methodology to simultaneously optimize the ozone and relative humidity composition for the $NO_x$ degradation using soil biofilter. Experiments were made as a function of inlet ozone concentration ($0{\sim}1,770\;ppb$) and relative humidity ($38{\sim}81%$). Factorial design ($2^2+3$) and response surface methodology by central composite designs were used to examine the role of two factors and optimal response condition on $NO_x$ degradation. It was found that a second-order response surface model can properly interpret the experimental data with an $R^2$-value of 0.9730 and F-value of 71.83, based on which the maximum $NO_x$ degradation was predicted up to 92.8% within our experimental conditions.

오존 정수처리 음용수조 구조물에 사용하는 에폭시 수지 방수.방식재의 표면특성 평가 (A Study on the Surface Deterioration Evaluation of Epoxy Resin Coating as Anticorrosive Material of Concrete Water Tank Using Ozone($O_3$))

  • 오상근;강효진;곽규성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.513-518
    • /
    • 2003
  • Recently, advanced systems for water treatment are introduced for water quality improvement. One of those systems is water treatment method using ozone($O_3$). For it has strong oxidizing energy, it is necessary to have materisl stability against $O_3$. In this paper, epoxy resin specimens using as anticorrosive material of concrete structure for drink water are used to serve as a material of deterioration evaluation. It is to be studied weight loss, surface corrosion of specimens, ingredient analysis of floating particle, a solute of chemical ingredient by way of accelerated ozone testing. As the results of experiment, specimen weight is decreased. The surface of specimen is eroded heavily and showed a loss of gloss and floating particle, and in the stability for drinking water, harmful ingredient is not detected in the water.

  • PDF

오존에 노출된 에폭시 코팅재의 표면 열화특성 평가기술 (Techniques for Characterizing Surface Deterioration of Epoxy Exposed to Ozone Damage)

  • 최성민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.167-177
    • /
    • 2014
  • 최근 수질오염의 악화로 고도정수처리시설에 대한 수요가 커지고 있으며, 오존처리와 같은 밀폐형 고도정수처리시설의 설치가 늘고 있는 실정이다. 그러나 오존의 강력한 산화작용으로 인해 콘크리트 구조물의 침식이 우려됨에 따라 오존에 대응 가능한 에폭시 방수방식재가 콘크리트 표층부 보호 코팅재로 적용되고 있다. 그러나 이러한 에폭시가 오존에 대한 성능수준 및 장기적 내구성을 명확히 측정할 방법과 기준이 없어 정확한 품질관리가 이루어지지 않고 있는 실정이며, 이로 인해 수처리용 콘크리트 구조물의 장기내구성 확보에 대한 우려가 제기되고 있다. 이 연구에서는 AFM과 나노인덴테이션 기법이 기존에 사용하던 평가방법인 육안관찰, 중량변화, 표면관찰, 색차분석 등의 간접적 평가방법과 함께 에폭시 방수방식재 평가방법으로써의 적합한지를 판단하고자 하였으며, 이를 위해 오존용으로 개발된 6종의 다른 성분으로 구성된 에폭시계 방수방식재를 대상으로 열화특성을 분석하였다. 연구결과 AFM과 나노인덴테이션을 활용할 경우 기존 평가방법보다 직접적이고 정량적인 평가가 가능함을 확인하였으며, 일부 에폭시 코팅재료의 경우 오존에 대한 성능 한계치 (임계치)를 명확히 확인할 수 있었다.

불소 단량체를 이용한 자외선 경화형 내 오존성 코팅 막 제조 (Preparation of UV-curable Ozone Resistance Coating Solutions using Fluoromonomer)

  • 이창호;이상구;김성래;이종대
    • Korean Chemical Engineering Research
    • /
    • 제50권3호
    • /
    • pp.421-426
    • /
    • 2012
  • 불소계 아크릴레이트 2,2,2-trifluoroethylmethacrylate을 사용한 자외선 경화형 유-무기 하이브리드 코팅 막에 있어서 무기물 및 사용되는 유기 단량체의 종류 및 조성이 내 오존성 및 표면 특성에 미치는 영향에 대해 연구하였다. 코팅액은 금속 알콕사이드인 tetraethoxysilane(TEOS)와 실란 커플링제인 methacryloyloxypropyltrimethoxysilane(MPTMS)로 구성된 유-무기 혼성 용액에 2,2,2-trifluoroethylmethacrylate와 자외선 경화를 위한 유기물을 첨가하여 제조되었다. 코팅막은 코팅액을 기재위에 바 코팅 한 후 자외선 경화를 통해 제조되었다. 제조된 코팅 막의 내 오존성은 TEOS의 함량이 증가할수록 내 오존성과 표면경도는 향상되었다. 또한, 불소 함량이 증가할수록 내 오존성은 향상되었지만 표면 경도는 다소 떨어졌다. 우레탄 아크릴레이트를 첨가한 코팅 막은 높은 연필경도를 나타내었다. 코팅 막의 투과도는 TEOS와 2,2,2-trifluoroethylmethacrylate의 함량에 큰 영향을 받지 않았다. 더욱이, 코팅 막은 90% 이상의 높은 투과도를 나타내었다.

반도체 감광막 제거공정 적용을 위한 고농도 오존발생장치 개발 (Development on the High Concentration Ozone Generator System for the Semiconductor Photoresist Strip Process)

  • 손영수;함상용
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.591-596
    • /
    • 2006
  • we have been developed on the ultra high concentration ozone generator system which is the core technology in the realization of the semiconductor photoresist strip process using the ozone-vapor chemistry. The proposed ozone generator system has the structure of the surface discharge type which adopt the high purity ceramic dielectric tube. We investigate the performance of the proposed ozone generator system experimentally and the results show that the system has very high ozone concentration characteristics of $19.7[wt%/O_2]$ at the flow rate of $0.3[{\ell}/min]$ of each discharge cell. As a result of the silicon wafer photoresist strip test, we obtained the strip rate of about 400[nm/min] at the ozone concentration of $16[wt%/O_2]$ and flow rate of $8[{\ell}/min]$. So, we confirmed that it's possible to use the proposed high concentration ozone generator system for the ozone-vapor photoresist strip process in the semiconductor and FPD industry.

Ultraviolet Microscopic Study on Lignin Distribution in the Fiber Cell Wall of BCTMP

  • Yoon, Seung-Lak;Yasuo Kojina
    • 펄프종이기술
    • /
    • 제36권1호
    • /
    • pp.61-66
    • /
    • 2004
  • Bleached chemithermomechanical pulp (BCTMP) was produced from CTMP of Betula maximowicziana Regel by two staged ozone-hydrogen peroxide bleaching in order to improve the optical properties of high yield pulp. This pulp was used for the evaluation of optical properties improvement, chemical characteristics of lignin in fiber and the relationship between lignin and optical properties in fiber cell wall. Hydrogen peroxide treatment improved the brightness, but the post color number (PC No.). There was little improvement on optical properties by ozone treatment, but this could be improved more by using two staged ozone-hydrogen peroxide bleaching. The hydrogen peroxide treatment did not make any change on chemical characteristics of lignin in cell wall, but by ozone treatment, it was found that the non-aromatic conjugated structure was existed in the surface of cell wall, but this could be removed by hydrogen peroxide treatment in two staged ozone-hydrogen peroxide treatment. Therefore, the optical properties was significantly improved, due to the removal of non-aromatic conjugated structure.

오존을 이용한 용존성 망간 제거 특성: 공존이온의 영향 및 최적주입량 (Characteristics of manganese removal by ozonation: Effect of existing co-ion and optimum dosage)

  • 곽연우;이슬기;이용수;홍성호
    • 상하수도학회지
    • /
    • 제32권2호
    • /
    • pp.145-152
    • /
    • 2018
  • This study is focused on manganese (Mn(II)) removal by ozonation in surface water. Instant ozone demand for the water was 0.5 mg/L in the study. When 0.5 mg/L of Mn(II) is existed in water, the optimum ozone concentration was 1.25 mg/L with reaction time 10 minutes to meet the drinking water regulation. The ozone concentration to meet the drinking water regulation was much higher than the stoichiometric concentration. The reaction of soluble manganese removal was so fast that the reaction time does not affect the removal dramatically. When Mn(II) is existed with Fe, the removal of Mn(II) was not affected by Fe ion. However As(V) is existed as co-ion the removal of Mn(II) was decreased by 10%. Adding ozone to surface water has limited effect to remove dissolved organic matter. When ozone is used as oxidant to remove Mn(II) in the water, the existing co-ion should be evaluated to determine optimum concentration.