• 제목/요약/키워드: Surface ozone

검색결과 370건 처리시간 0.024초

서울.수도권 지역 고농도 오존 사례의 지상 및 종관 기상 특성 (Characteristics of Surface and Synoptic Meteorology During High-Ozone Episodes in the Greater Seoul Area)

  • 오현선;김영성
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.441-455
    • /
    • 1999
  • Meteorological characteristics of three high-ozone episodes in the Greater Seoul Area, selected on the basis of morning-average wind direction and speed for the 1990~1997 period, were investigated. Three high-ozone episodes thus selected were seven days of July 3~9, 1992, nine days of July 21~29, 1994, and three days of August 22~24, 1994. Along with surface meteorological data from the Seoul Weather Station, surface and 850-hPa wind fields over the Northest Asia around the Korean Peninsula were used for the analysis. In the July 1992 episode, westerly winds were most frequent as a result of the influence of a high-pressure system in the west behind the trough. In contrast, in the July 1994 episode, easterly winds were most frequent due to the effect of a typhoon moving north from the south of Japan. Despite different prevailing wind directions in the two episodes, the peak ozone concentration of each episode always occurred when a sea-land breeze developed in association with weak synoptic forcing. The August 1994 episode, selected as being representative of calm conditions, was another typical example in which peak ozone concentration rose to 322 ppb under the well-developed sea-land breeze. All three high-ozone episodes were terminated by precipitation, and subsequent rises in ozone concentrations were also suppressed by a series of precipitation afterwards. In particular, two heavy rainfalls were the main reason why the August 1994 episode, with the highest and second-highest ozone concentrations during the 1990~1997 period, lasted for only a few days.

  • PDF

Inactivation of Vibrio parahaemolyticus by Aqueous Ozone

  • Feng, Lifang;Zhang, Kuo;Gao, Mengsha;Shi, Chunwei;Ge, Caiyun;Qu, Daofeng;Zhu, Junli;Shi, Yugang;Han, Jianzhong
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권8호
    • /
    • pp.1233-1246
    • /
    • 2018
  • Vibrio parahaemolyticus contamination causes serious foodborne illness and has become a global health problem. As a disinfectant, aqueous ozone can effectively kill a number of bacteria, viruses, parasites, and other microorganisms. In this study, three factors, namely, the aqueous ozone concentration, the exposure time, and the bacterial density, were analyzed by response surface methodology, and the aqueous ozone concentration was the most influential factor in the sterilization ratio. Under low aqueous ozone concentrations (less than 0.125 mg/l), the bacterial cell membranes remained intact, and the ozone was detoxified by intracellular antioxidant enzymes (e.g., superoxide dismutase and catalase). Under high aqueous ozone concentrations (more than 1 mg/l), cell membranes were damaged by the degree of peripheral electronegativity at the cell surface and the concentration of lactate dehydrogenase released into the extracellular space, and the ultrastructures of the cells were confirmed by transmission electron microscopy. Aqueous ozone penetrated the cells through leaking membranes, inactivated the enzymes, inhibited almost all the genes, and degraded the genetic materials of gDNA and total RNA, which eventually led to cell death.

지표면의 종류에 따른 오존의 건성침적속도에 관한 수치모의 (Numerical Simulation for Dry Deposition Velocity of Ozone According to Land-use Types)

  • 이화운;노순아;문난경
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.583-594
    • /
    • 2003
  • Ozone is an important atmospheric pollutant that is occurred in tropospheric chemical process and it also affects the human health and plants. For a correct application of abatement strategies for ozone, it is necessary to understand the factors that control atmospheric ozone removal by dry deposition processes. The present study investigates the numerical simulation of the dry deposition velocity (V$^{d}$ ) obtained from PNU/DEM (Pusan National University Deposition Model). PNU/DEM includes seasonal categories, meteorological factors, surface properties and land-use types and proposes for an accurate numerical computation. And, this study examines the ability of the PNU/DEM to compute V$_{d}$ of ozone over water surfaces and evaluates PNU/DEM by comparing its estimated V$_{d}$ to past observed V$_{d}$ over water. The parametrization was found to yield V$_{d}$ values generally in good agreement with the observations for the deciduous forest and the coniferous forest. Ozone is removed slowly at wet surface or water due to its low water solubility. Therefore V$_{d}$ values over water were lower than Vd values over the other surfaces. Comparison of PNU/DEM simulated V d values to observations of ozone V$_{d}$ that have been reported in the literature implies that PNU/DEM produces realistic results.

UV/Ozone 복합 살균기의 살균력 개선 연구 (Improvement of a UV/Ozone Duplex Sterilizer)

  • 지정은;양원균;박은철;김강석;주정훈
    • 한국표면공학회지
    • /
    • 제41권2호
    • /
    • pp.76-82
    • /
    • 2008
  • We investigated sterilization characteristics of UV lights by counting the number of bacteria units with varying sterilization time and distance from the light source. We focused on an idea that UV light of 184.9 nm could generate ozone and developed a new sterilizer. The UV-ozone duplex system sterilized bacteria faster than UV-only sterilizers. To reduce shadowing effects by target objects, we used UV transparent quartz plate as a support and put a reflecting plate. Distribution of UV irradiation intensity and ozone supply were analyzed by a 3D model and measured by a semiconductor UV sensor. But even with an Al reflector, multi-layered pens could not be treated properly from UV irradiation only. Ozone generating lamp could treat more uniformly multi-layered pens with a stirring fan by supplying ozone to shadowed surfaces.

고농도 오존일의 강우와 운량 (Precipitation and Cloud Cover on High Ozone Days)

  • 김영성;김영진;윤순창
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.747-755
    • /
    • 1999
  • Effects of precipitation and cloud cover on high ozone days are examined by investigating the precipitation and average cloud cover before the ozone peak time within a day. High ozone days above 100 ppb in the Greater Seoul Area(GSA) for the ozone season from May to September are chosen for the analyses in terms of the surface meteorological data during 1990~1997. The result shows that the effect of precipitation on the rise of ozone concentration is definitely negative so that ozone concentration could not rise above 100ppb immediately after precipitation. But, the effect of cloud cover is associated with the variations of other meteorological parameters. The number of high ozone days with "zero" cloud cover is rather less than that with cloud cover of 1 to 4 since temperature is usually lower in "zero" cloud cover days. Furthermore, ozone concentration can rise above 100ppb even with full cloud cover when the wind is weak and the temperature is high.temperature is high.

  • PDF

TOVS로 부터 도출한 한반도 부근의 전오존량 분포 및 그 특성 비교 (The Distribution of Total Ozone Amounts and Intercomparison of their characteristics Derived from the TOVS Observations over the Korean Peninsula)

  • 정효상;주상원
    • 대한원격탐사학회지
    • /
    • 제11권3호
    • /
    • pp.23-31
    • /
    • 1995
  • 기상청에서는 1990년부터 Smith등(1984,1986)이 개발한 ITPP-VI(International TOVS Program Package)를 사용하여 직접 물리 해법을 이용한 연직온도분포 및 총오존량을 산출하여 예보현업에 이용하고 있다. 그러나 현재의 초기입력자료로 사용되는 기후값은 너무 오래되었고, 국지효과나 한반도 부근의 특성이 제외되었으므로 도출된 전오존량의 분포를 직접 사용하기에는 그 정확성이나 신빙성이 희박하다. 따라서 ITPP-VI로부터 오존량 산출자료의 질적 개선을 위해 초기 입력자료중 지표값을 기후자료 대신에 GPV(Gridded Point Values) 자료를 입력하여 오존량 도출을 수행하였다. GPV자료의 입력을 통한 TOVS 오존량 자료(TOVS-GPV)가 정량적으로 어느 정도 개선되었는 지 알아보기 위하여 두경우의 총오존분포도를 비교하였다. GPV 지표자료의 입력으로 도출한 총 오존량은 기후값으로 도출한 총오존량(TOVS-CLIMA)에 비해 한반도 부근에서의 오존량 변화를 더 자세하게 표현하였다. 정량적으로 질적 개선을 알아보기 위해 1994년 2월 한달동안 지상 관측 자료로써 연세대학교의 오존분광기(Dobsometer)로 관측한 오존량(Uy), TOVS-GPV(Ug), TOVS- CLIMAT(Uc), 그리고 TOMS(Total Ozone Monitoring System) 관측값(Um)을 이용하여 나타낸 결과, 월변화의 경향은 연세대학교 총오존량값의 변화에 대해 TOVS-GPV(Ug), TOVS-CLIMAT (Uc)와 TOMS(Um) 값들의 변화는 크지만, 새로운 TOVS-GPV 오존량은 TOVS-CLIMAT 오존 량에 비해 TOMS 오존량과 연세대학교 관측치와 유사한 경향을 보였다.

반도체 습식 세정 공정 중 상온의 초순수와 염기성 수용액 내에서 오존의 용해도 최적화 (The Optimization of Ozone Solubility and Half Life Time in Ultra Pure Water and Alkaline Solution on Semiconductor Wet Cleaning Process)

  • 이상호;이승호;김규채;권태영;박진구;배소익;이건호;김인정
    • 반도체디스플레이기술학회지
    • /
    • 제4권4호
    • /
    • pp.19-26
    • /
    • 2005
  • The process optimization of ozone concentration and half life time was investigated in ultra pure water and alkaline solutions for the wet cleaning of silicon wafer surface at room temperature. In the ultra pure water,. the maximum concentration (35 ppm) of ozone was measured at oxygen flow rate of 3 liters/min and ozone generator power over 60%. The half life time of ozone increased at lower power of ozone generator. Additive gases such as $N_2$ and $CO_2$ were added to increase the concentration and half life time of ozone. Although the maximum ozone concentration was higher with the addition of $N_2$ gas, a longer half life time was observed with the addition of $CO_2$. When $NH_4OH$ of 0.05 or 0.10 vol% was added in DI water, the pH of the solution was around 10. The addition of ozone resulted in the half life time less than 1 min. In order to maintain high pH and ozone concentration, ozone was continuously supplied in 0.05 vol% ammonia solutions. 3 ppm of ozone was dissolved in ammonia solutions. The static contact angle of silicon wafer surface became hydrophilic. The particle removal was possible alkaline ozone solutions. The organic contamination can be removed by ozonated ultra pure water and then alkaline solution containing ozone can remove the particles on silicon surface at room temperature.

  • PDF

수표면 방전을 이용한 오존발생특성 (Ozone Generation Characteristic Utilizing a Water Surface Discharge)

  • 김인웅;김찬규;박승록;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1763-1765
    • /
    • 2002
  • A silent discharge type ozone generator using a water surface as an electrode has been proposed and investigated experimentally. A water surface has many Taylor cones when the ac voltage is applied on its surface, which increase the discharge surface greatly. In this paper, it was studied about the effect of the water conductivity. As increasing the water conductivity, the amount of generated ozone was increased and the silent discharge on the water surface took place steadily and calmly.

  • PDF

난분해성 유기물질 제거를 위한 오존/촉매 공정의 비교에 관한 연구 (A Comparative Study of Catalytic Ozone processes for Removal of Refractory Organics)

  • 이규환;이유미;이동석
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.199-205
    • /
    • 2006
  • Ozone alone and catalytic ozone processes were introduced for treatment of humic acid, which is representative refractory organic compound. The treatment efficiencies of humic acid in each process were analyzed in pH variation, DOC removal, and $UV_{254}$ decrease. Mn loaded GAC catalyst was prepared by loading potassium permanganate onto the granular activated carbon surface. BCM-GAC and BCM-Silica gel catalyst were prepared by BCM. $UV_{254}$ decrease in all processes was comparatively high with efficiency over 87%. DOC removal in ozone/GAC process was the highest with 78%, and removal rates for other processes followed the order ozone/BCM-GAC(62%) > ozone/BCM-silica gel(45%) > ozone/silica gel(43%) > ozone/Mn Loaded GAC(42%) > ozone alone(37%).

  • PDF

슬릿 유전체 장벽을 갖는 선대 평판형 방전장치의 방전 및 오존 발생특성 (Discharge and Ozone Generation Characteristics of a Wire-Plate Discharge System with a Slit Barrier)

  • 문재덕;정재승
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.421-426
    • /
    • 2005
  • A wire-plate discharge system with a slit barrier has been proposed and investigated experimentally by focusing on the discharges on the slit barrier and ozone generation characteristics. This wire-plate discharge system with a slit barrier can generate an intensive corona discharges, and produce corona discharge twice, once from the corona wire electrode and second time from the surface and the slits of the slit dielectric barrier. As a result this propose wire-plate discharge system with the slit barrier can produce greatly increased ozone than without the slit barrier. This type of wire-plate discharge system with the slit barrier could be used for effective ozone generation as a means with retard to the removal of pollutant gas