• 제목/요약/키워드: Surface hologram

검색결과 39건 처리시간 0.025초

Optical Performance Degradation Effects by Fabrication Errors of Circular-type Computer Generated Holograms

  • Kim, Young-Gwang;Rhee, Hyug-Gyo;Ghim, Young-Sik
    • Journal of the Korean Physical Society
    • /
    • 제73권11호
    • /
    • pp.1657-1662
    • /
    • 2018
  • A null test method which relies on a computer generated hologram (CGH) is widely used to measure a large aspheric surface. For precise measurements of the surface shape of an aspheric optics, the CGH must precisely generate a wavefront that can fit on the ideal surface shape of the aspheric optics. If fabrication errors arise in the CGH, an unwanted wavefront will be generated and the measuring result will lack trustworthiness. Thus far, there has been limited research on wavefronts generated by CGH using only linear-type binary grating models. In this study, a theoretical error model of a circular-type zone plate, the most commonly used types for CGH patterns, is suggested. The proposed error model is checked by simulations and experiments.

비접촉 레이저 광센서의 성능 향상을 위한 센서보정에 관한 연구 (Development of a Sensor Calibration to Enhance the Performance of a Non-contact Laser Optical Sensor Unit)

  • 서평원;유영기;오춘석;변종환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.579-581
    • /
    • 2006
  • Flat panel image display devices such as TFT LCD and PDP have required more large area and high quality control components. To control the qualities of the components, measurements of the flatness of a plate glass has been required. In order to measure the shape of the specular objects, Non-Contact Optical Sensor using Hologram laser unit was proposed. The sensor has a optical system that is composed of a Hologram laser and objective lens. The temperature of the sensor body is controlled by TEC(Thermoelectric Cooler) to maintain the same wavelength of the diode laser. In this research, we proposed the calibration scheme to make sensor real time measuring sensor. From the experimental results we see that the proposed sensor unit can measure the position of the glass surface in rial time.

  • PDF

근접장 이진 홀로그램의 다중화, 다층화 및 병렬 저장 (Multiplexed, Stack-Wise, and Parallel Recording of Near-Field Binary Holograms)

  • 김경염;강진구;이병호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.382-389
    • /
    • 2002
  • We present experimental results on the multiplexed and stack-wise recording of near-field holograms. Experiments on angular multiplexing show that the angular selectivity of near-field hologram is better than that of the conventional hologram. Experiments on stack-wise recording prove that near-fields originated from sub-diffraction-limit-size objects could be stored in a photorefractive crystal at 2mm apart from the crystal surface. In addition, to improve the data access and transfer time, a silicon nano-aperture array was introduced and applied to the recording of near-field holograms.

건축물 홀로그램 표현에서 3D 실체감 표현 향상방안 (Realistic Enhancement of 3D Expressions for Building Expressions with Hologram)

  • 신성윤;이현창
    • 한국정보통신학회논문지
    • /
    • 제23권9호
    • /
    • pp.1104-1109
    • /
    • 2019
  • 홀로그램을 이용한 비즈니스 활동이 유사홀로그램을 이용한 활용이 많이 제시되고 있다. 이에 본 연구에서는 최대 3면 혹은 4면을 이용한 유사 홀로그램에 대한 개요를 살펴보며, 콘텐츠로서 건물을 3D(dimension) 모델링을 통해 제작된 결과물을 활용하여 홀로렌즈에서부터 유사 홀로그램을 위한 건축물 표현에 관하여 다루고자 한다. 또한 모델링의 단점인 실사 모습을 반영하기 위해서 실제 건물의 표면을 사진촬영을 통해 3D 모델에 반영함으로써 객체의 3D 표현감을 향상시키는 방안을 제시한다. 실질적인 건물을 AR/VR/MR 등 가상의 공간에서 보여지는 여러 방법들 가운데 홀로그램을 통해 공간상에 가상으로 볼 수 있도록 한다. 본 연구를 통해 건축물 혹은 문화재 등 다양한 소재를 홀로그램으로 실감 표현이 향상될 것이다.

The Selection of Measurement Positions for BEM Based NAH Using a Non-conformal Hologram to Reduce the Reconstruction Error

  • Oey, Agustinus;Ih, Jeong-Guon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1018-1021
    • /
    • 2007
  • This paper explores the use of BEM based NAH to reconstruct the surface vibration of a plate in a rectangular finite cavity, in which the distances between sensors and the nearest points on the source surface are not equal. In such circumstances, different degree of information on propagating and non-propagating wave components will be detected by sensors at different positions, as well as the influence of measurement noise will vary significantly from the nearest points of measurement to the farthest ones. On the other hand, the condition number of the vibro-acoustic transfer function matrix relating normal surface velocities and field pressures will becomes high, numerically indicating an increase of linear dependency between rows of transfer function matrix. The combination of poor measurement and high condition number will result inaccurate reconstruction. Therefore, one approach to be investigated in this work is to select the measurement positions in such ways that reduce measurement redundancy, as it indicated by the condition number. The improvement is found to be significant in the numerical simulations utilizing two different criterions, spanning from over-determined to under-determined cases, and in the validation experiment.

  • PDF

이진 컴퓨터 형성 홀로그램을 이용한 비구면 형상 측정용 위상편이 회절격자 간섭계 (Diffraction grating interferometer for null testing of aspheric surface with binary amplitude CGH)

  • 황태준;김승우
    • 한국광학회지
    • /
    • 제15권4호
    • /
    • pp.313-320
    • /
    • 2004
  • 위상편이 회절격자 간섭계와 이진 컴퓨터 형성 홀로그램을 제작하여 널 시스템을 구성하고 비구면형상 측정 시스템을 구축하였다. 제안하는 시스템은 비구면형상에 맞게 제작된 이진 컴퓨터 형상 홀로그램과 가시도가 조정된 위상편이 회절격자간섭계로 이루어져있다. 위상편이 회절격자간섭계는 회절격자의 홈 형상이나 간섭을 일으킬 측정광과 기준광을 바꿈으로써 가시도를 쉽게 조절할 수 있고, 높은 수준의 측정 정확도를 가지는 장점을 가지고 있다. 이진 컴퓨터 형성 홀로그램은 비구면의 정보를 통하여 컴퓨터로 수치모사한 후 전자-빔 리토그래피 장비로 제작할 수 있고, 위상편이 회절격자 간섭계, 비구면과 함께 자동곡률측정 방식으로 설치된다. 간섭계와 홀로그램을 제작한 후 비구면을 측정, 실험을 수행하고 시스템을 평가하였다.

마이크로 미러 표면을 이용한 홀로그램 저장 밀도의 향상 (Improvement of Hologram Dencity using a Micro-Mirror Surface)

  • 양병춘
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1998년도 제15회 광학 및 양자전자 학술발표회 논문집
    • /
    • pp.92-93
    • /
    • 1998
  • 폴리 실리톤으로 제작된 마이크로 미러의 표면에서 반사되는 스펙클을 이용하여 홀 로그램을 기록하였다. 마이크로 미러에서 반사되는 스펙클 패턴은 다중모드 광섬유에서 관 측할 수 있는 스펙클과 거의 비슷한 형태로 보이며 이를 이용하여 홀로그램의 기록밀도를 향상시킬수 있음을 보였다.

  • PDF

Null CGH를 이용한 포물면경 형상 측정 (Null computer generated hologram test for measurement of parabolic mirror)

  • 김태희;김성하;문일권;이윤우
    • 한국광학회지
    • /
    • 제13권6호
    • /
    • pp.537-542
    • /
    • 2002
  • 서로 다른 null optics를 사용하는 null test의 측정결과를 상호 비교함으로써 null CGH test 신뢰성을 알아보았다. 회전대칭 포물면경(90mm, F/0.76) 형상측정 및 측정장치 정렬용 null CGH를 설계, encoding, 제작 후 null CGH test를 실시하였다. 결과를 평면경을 null optics로 사용하는 autocollimation test측정치와 비교하여 null CGH test의 정확성을 평가하였다.

레이저 홀로그램을 이용한 플라즈마 진단 (Plasma Diagnostics Using Laser Hologram)

  • 김병환;정진수;서준현
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 추계학술대회 논문집
    • /
    • pp.182-182
    • /
    • 2015
  • 레이저 홀로그램을 이용하여 $N_2$ 플라즈마를 진단하였다. 홀로그램 이미지에서 추출한 데이터는 optical emission spectroscopy와 langmuir probe로 측정한 데이터와 매우 유사한 경향성을 보였다. 이는 홀로그램 센서가 플라즈마의 전기 광학적 입자 정보를 제공할 수 있음을 의미한다. 홀로그램 안에 이 같은 정보가 저장될 수 있는 원리는 빛을 구성하는 양의 전하를 가지는 입자와 진공을 채우고 있는 음의 입자가 함께 형성하는 전자기적 에너지 필드의 형성에 있음을 밝힌다. 이러한 원리에 기초해서 그간 개발된 센서들을 소개한다.

  • PDF

디지털홀로그램을 이용한 웨이퍼와 박막간의 경계면 모니터링 (Monitoring of interface between wafer and thin film using digital hologram)

  • 서준현;김병환
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2014년도 추계학술대회 논문집
    • /
    • pp.230-230
    • /
    • 2014
  • 디지털 홀로그램 이미징 장치를 이용하여 박막과 웨이퍼 간의 두께 및 하전입자의 분포를 모니터링하는 센서의 성능을 보고한다. 이 센서는 웨이퍼와 SiN 박막 간의 경계를 구분하였으며, 경계에서의 하전입자의 분포의 분석도 가능함을 보였다. 이 센서는 다양한 종류의 계면 내지 박막 내부의 하전입자의 분포의 측정을 가능하게 하며, 또한 두께 변이의 실시간 측정도 가능하게 하여 향후 대량 생산현장에서의 광범위한 응용이 예상된다.

  • PDF