• 제목/요약/키워드: Surface examination

검색결과 854건 처리시간 0.022초

치아우식증 진단시 임상검사와 파노라마방사선사진검사의 탐지능 비교 (Comparison of the Clinical Examination with the Panoramic Radiography in the Diagnosis of Dental Caries)

  • 최항문
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.275-282
    • /
    • 1999
  • Purpose: The objective of this study was to compare clinical examination of dental caries and secondary caries with panoramic examination. and to examine bone lesions and dental anomaly of unerupted state. Materials and Methods: In this study. clinical records and panoramic radiographs were available for 89 first grade students in elementary school. Dental caries of occlusal surfaces. proximal surfaces. and buccolingual surfaces were examined. Secondary caries was examined too. In addition. the central lesion and dental anomaly of unerupted state were examined in panoramic radiographs. Results: The obtained results were as followed: 1. Carious detectability of clinical examination in occlusal and buccolingual surface was higher than that of panoramic examination. but it is statistically insignificant(p>0.05). In proximal surface. carious detect ability of panoramic examination was higher than that of clinical examination. and it is statistically significant(p<0.01). 2. In contrast to clinical examination only. when the two examination methods were combined. there was additional detection of dental caries(26.7% in occlusal surface. 48.2% in proximal surface. 33.3% in buccolingual surface. and 38.3% totally). 3. In detection of secondary caries. panoramic examination had lower ability than clinical examination in all three surfaces. but in case that both methods were combined. totally 36.0% extra carious lesions were detected. 4. In panoramic examination. detectability of secondary caries in upper teeth is lower than lower teeth. 5. In panoramic examination. it was possible to detect the central lesions and dental anomalies of unerupted state which cannot be detected in clinical examination. Conclusion: It is useful to combine the panoramic examination with clinical examination in order to increase carious detectability and to evaluate the central lesions and dental anomalies of unerupted state

  • PDF

흉부 왼쪽 엑스선검사 시 위치 잡기의 중요성 (The Importance of Positioning in Left Lateral Chest X-Ray Examination)

  • 조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권4호
    • /
    • pp.287-294
    • /
    • 2023
  • This study was conducted to ultimately reduce unnecessary radiation exposure by emphasizing the need and importance of correct positioning by examining the positioning relationship of anatomical structures in the human body and changes in X-ray images according to changes in patient positioning during the left lateral chest X-ray examination. This study investigated and analyzed previously published papers and books on the left lateral chest X-ray examination to find out the importance of positioning in the left lateral chest X-ray examination. To find out the importance of correct positioning in the left lateral chest X-ray, we compared three images of incorrectly positioned right thorax and left thorax rotated forward and the lower median surface of the body leaning against the image receptor. In the left lateral chest examination, a distorted image was obtained in which the shape of the anatomical structure observed in the image was changed according to the presence or absence of rotation of the patient and the inclination of the median visual surface. X-ray images with the most accurate and large amount of information were obtained from X-ray images with the correct positioning performed during left lateral chest X-ray examination. Therefore, It is believed that the left lateral chest X-ray examination will have beneficial effects such as providing accurate medical information, preventing misdiagnosis, reducing social costs, and ultimately reducing radiation exposure.

자연기흉에 대한 Thoracoscopy 의 임상적의의 (Clinical Significance of Thoracoscopy on Spontaneous Pneumothorax)

  • 김영태;김근호
    • Journal of Chest Surgery
    • /
    • 제8권1호
    • /
    • pp.19-28
    • /
    • 1975
  • The thoracoscopic study was reported on 21 cases of spontaneous pneumothorax requiring surgical management, and clinical values of thoracoscopic examination on spontaneous pneumothorax were also discussed. patients were treated in the Department of .Thoracic Surgery, Hanyang University Hospital for the period of two Years from May 1972 to April 1974. For exact detection of etiologic factors on spontaneous pneumothorax, the thoracoscopic examination in the intrapleural space was performed in parallel with X-ray study. this study, the difference of diagnostic and therapeutic significance between radiological and thoracoscopic findings were observed and compared simultaneously. The results are summerized as follows: Patients age was distributed between 3 and 70 years old with highest incidence in the age group of sixty decade [33. 3%], and sex ratio of male to female was 5:2. The tuberculous processes which developed superficial subpleural layer in the lung parenchyme, on the pulmonary surface could be observed by thoracoscopic examination in a characteristic picture. detection ratio of pulmonary tuberculosis by the radiologic study to that by thoracoscopy was 8:2. The adhesion between the visceral and the parietal pleura which could possibly make a rupture of the alveola and the visceral pleura was found to be localized in a small area of the lung surface. The other part of the lung surface was free of the adhesion and, therefore, the movement of the lung took place completely without any difficulty. The ruptured orifice of the pleura and pathological changes surrounding the orifice can be detected by thoracoscopy, but not by other means such as radiologic examination. A single tuberculous bleb and multiple emphysematous blebs were found on 6 cases out of 21 cases of spontaneous pneumothorax. Among these cases, radiologic Study revealed the bleb only in one patient. On the other hand, the blebs were found in all the six patients by means of thoracoscopic examination. It gives the detection ratio of bleb by radiologic study to that by thoracoscopy was 1:6. By thoracoscopy, the rupture on the lung surface were visualized on the 10 patients out of a total of 21 patients [10 patients of visual rupture]. However, the rupture of the pleura was not observed on the rest of 11 patients even by thoracoscopic examination [11 patients of non visual rupture]. Five patients [50%] out of ten who had the visual rupture on the lung surface was required a surgical operation to remove pneumothorax. For the patients who were detected to have the visual rupture of the pleura by thoracoscopy, be considered in the early stage of closed thoracostomy. of 21 patients, 16 patients [11 patients of non visual rupture of the pleura and 5 patients of visual rupture of the pleura] who received no surgical management, were treated with closed thoracostomy with continuous suction, and the` pneumothorax was healed completely up in each cases. Therapeutic measures for the remaining 5 patients of visual rupture of the pleura who were subjected to surgical approach for radical treatment of spontaneous pneumothorax were accordingly complicated, and the following different procedures were properly indicated case by case, that is, rib resection thoracostomy, simple closure of ruptured visceral pleura, wedged resection of the lung, and lobectomy.

  • PDF

펌프 Diffuser Vane 표면결함 깊이측정 기법 개발 (Development of Inspection Technology for the Depth Sizing on Surface Flaw of Pump Diffuser Vane)

  • 박철용;김진회
    • 한국압력기기공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.46-49
    • /
    • 2008
  • NDE(Nondestructive examination) detects a flaw or discontinuity in materials. Flaws detected by the pre-service or in-service examinations shall be sized for the purpose of analysis and repair. A flaw that is initiated from the surface is difficult to determine its depth by NDE. The depth of the surface flaw can be measured using an ultrasonic diffracted wave. To find the optimum standard for ultrasonic parameter(For example, frequency & size of transducer), a mock-up test and simulation were established and studied. This inspection technology may show the depth sizing possibility of the flaw down to nearly two(2) mm.

  • PDF

잔골재 표건상태 판정방법 개선에 관한 연구 (A study on the improvable decision of saturated surface dry of fine aggregate)

  • 송지흡;조현대;최현수;전명훈;이도헌;정재동
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.153-156
    • /
    • 2005
  • Surface dry condition examination method on the KS F 2504(Testing method for specific gravity and absorption of fine aggregate) has dim detail prescriptions which can cause different ways of understanding based on one's convinence, not on correct means of rule. So we investigate the problems about the inconsistency on decisioing surface dry condition at management examination in the lab and scene. In conclusion, free-falling method is easier and faster than self-weight method. And we also found that the most important face on decisioning surface dry is compacting factor of tamping rod.

  • PDF

MVR(Machinery Vapor Recompressor)의 고장분석에 관한 연구

  • 김태구
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2002년도 춘계 학술논문발표회 논문집
    • /
    • pp.171-176
    • /
    • 2002
  • 이 논문은 MVR(Machinery Vapor Recompressor) Impeller Blade의 파손으로 발생한 사고원인 조사Um 관한 것이다 MVR의 고장의 원인을 밝히기 위해서 육안 분석(visual examination), 실체현미경 분석(Stereoscopic examination), SEM 분석 (SEM examination)을 한 결과 주조결함으로 인한 Surface Crack이 장기간 지속되어 Initial Crack이 생성된 뒤에 이 부위에 응력이 집중되면서 Fatigue Crack이 임계 Crack 길이까지 진행되었다. 여기에 Impeller 회전속도의 상승으로 인한 과부하가 부가되어 MVR의 Blade가 파손된 것을 알 수 있었다.(중략)

  • PDF

동의수세보원(東醫壽世保元) 경험방에 근거한 사상체질별 복진의 문헌연구 (Overview on the Sasang Constitutional Abdominal Examination based on Experienced Prescriptions in the Donguisusebowon)

  • 이재철;김상혁
    • 동의생리병리학회지
    • /
    • 제26권2호
    • /
    • pp.141-146
    • /
    • 2012
  • Researches of Sasang Consitutional Medicine(SCM) have been conducted in many ways, especially for objective diagnosis methods of SCM. Despite of these efforts, relationship between SCM and abdominal examination is rarely known. Therefore 7 books related to abdominal examination and arranged specific abdominal examination descriptions in each books based on Experienced prescriptions(經驗方) of Donguisusebowon(東醫壽世保元) or Longevity and Life Preservation in Eastern Medicine were collected. In result, So-eumin and So-yangin show opposite descriptions to each others in abdominal examination. So-eumin has stuffiness and rigidity below heart, lower abdominal fullness and cramp. In contrast, So-yangin has fullness in the chest and hypochondrium, chest bind, lower abdominal numbness and lower tension. Strong abdominal surface tension could be palpated in Taeum-in's abdominal examination. Advantages of Abdominal Examination are notified recently, thanks to easiness of performing, objectiveness and well-adaptation to Theory of Traditional Eastern Medicine. These advantages could contribute to researching diagnosis of SCM with theory consensus of SCM specialists and practical trials.

Digital Imaging Fiber-Optic Trans-illumination을 이용한 초기 법랑질 우식병소의 조기 진단 (EARLY DETECTION OF INITIAL DENTAL CARIES USING A $DIFOTI^{TM}$)

  • 염혜웅;유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제31권4호
    • /
    • pp.587-597
    • /
    • 2004
  • 치아 우식증의 발생과 관련된 분야에 대한 연구는 지난 20년간 활발히 진행되어 괄목할만한 발전을 이루었다. 그러나 치아 우식증의 원천적인 예방을 이루기 위해서는 보다 새로운 실험 장비와 기구를 이용한 다각적인 연구가 요구되며, 이러한 흐름에 부응하여 미국의 인디아나 치과대학을 중심으로 초기 법랑질 우식증에 관한 재조명이 집중적으로 이루어지고 있다. 또한 세계적으로 치과계의 지속적인 대민 교육과 홍보 및 불소화사업 등의 우식 예방에 대한 노력과 구강 보건에 대한 대중의 인식 향상을 통해 치아 우식증이 감소하는 추세에 있으며, 이로 인해 치아 우식증이 기존의 교합면보다 인접면에서 더 많이 발견되는 추세로 변화되고 있다. 치아 우식증의 조기 진단을 목적으로 새로운 진단 장비들이 속속 개발되고 있으며 이미 성능의 우수성이 실험실 연구를 통해 입증된 바 있다. 본 연구의 목적은 초기 인접면 우식증의 진단에 있어 새로 개발된 $DIFOTI^{TM}$ 시스템의 효능을 기존의 방법인 시진 및 교익방사선사진과 비교 평가하고, 임상 적용시의 문제점을 파악하여 차후 $DIFOTI^{TM}$ 시스템 개발에 필요한 개선안을 제시함과 아울러 치아 우식증의 예방 및 불소를 이용한 초기 우식증 재광화 방법에 대한 기초 연구 자료를 마련하고자하였다. 학동기 연령에 있는 유치 탈락 시기에 근접한 것으로 기대되는 23명의 아동을 대상으로 구강 검진 2회, 구치부 교익 방사선 필름 판독 2회 그리고 전치부 및 구치부 $DIFOTI^{TM}$ 이미지 판독 2회를 실시하고 각 방법에 대한 신뢰도 평가를 시행한 결과 다음과 같은 결론을 얻었다. 1. 구강 검진시 검사자간 신뢰도는 교합면에서 평균 0.8470으로 가장 높았으며, 근심면 평균 0.6430, 원심면 평균 0.5727, 설면 평균 0.2807 그리고 협면 평균 0.2339순으로 나타났다. 구치부에 국한시킨 경우 교합면에서는 평균 0.8577이었으며, 원심면 평균 0.8211, 설면 평균 0.7728, 협면 평균 0.7152, 근심면 평균 0.6782 순으로 나타났다. 2. 구치부 교익 방사선 사진 판독 결과에 대한 검사자간 신뢰도는 교합면 평균 0.8346, 근심면 평균 0.8675, 원심면 평균 0.8482 순으로 나타났다. 3. $DIFOTI^{TM}$ 이미지 판독 결과에 대한 검사자간 신뢰도는 교합면 평균 0.8437, 협면 평균 8379, 근심면 평균 0.8223, 설면 평균 0.7766, 원심면 평균 0.6781 순으로 나타났다. 4. 치아 우식증 진단율을 비교한 결과 교합면, 협면, 설면에서는 $DIFOTI^{TM}$ 이미지 판독이 가장 우수한 것으로 나타났으며(p<0.05), 근심면과 원심면에서는 방사선 판독이 가장 우수한 것으로 나타났다(p<0.05).

  • PDF

초음파검사에서 인체모의 매질팬텀을 이용한 온도 변화와 TI MI 분석 (An Analysis of Temperature Change and TI MI using Tissue Mimicking Phantom in Ultrasonic Examination)

  • 전철민;한재복;곽종길;송종남
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.751-759
    • /
    • 2022
  • 현재 진단 초음파 및 건강검진 목적의 초음파 검사는 널리 이용되고 있고 건강보험 적용으로 더욱 증가 추세를 보이고 있다. 하지만 초음파검사의 위해성은 현재까지 명확히 밝혀진 바가 없어 초음파 검사 시 인체 조직의 온도가 상승하는 열효과를 알아보고자 본 연구에서는 인체 모의 매질 팬텀을 이용해 주파수, 모드별에 따른 표면과 심부 온도 변화를 시간별로 측정하였고 TI, MI 값도 비교하였다. 인체와 유사한 음향 특성 있는 카파 카라기난 분말과 고형화를 위해 염화칼륨을 소량 첨가하여 모의 팬텀 제작하였고 표면 온도계와 탐침용 온도계를 사용하여 표면과 심부 온도 변화를 측정하였다. 그 결과 저주파수를 사용하는 Convex Probe가 고주파를 사용하는 Linear Probe보다 높은 온도 상승을 보여 유의미한 차이를 보였고 표면에서 온도 상승이 가장 높았으며 1 cm의 낮은 깊이는 일시적 온도상승은 나타내지만 유의미한 온도변화는 없었다. 5 cm ~ 15 cm의 심부온도 변화는 없었으며 검사 시간동안 TI, MI값은 변화가 없었다. 이는 15분 실험동안 표면온도만 상승하였고 심부에는 온도변화가 없었기 때문에 인체에 유해할 만큼의 온도 변화를 나타내지 않을 것으로 사료되며 통상적인 진단초음파의 15분의 검사시간은 임상에서의 사용에는 무리가 없을 것으로 생각되지만 특정 부위의 장시간 검사는 온도 상승을 일으킬 수 있으므로 지양해야 될 것으로 사료된다.

의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구 (Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions)

  • 이신우;김다은;문채원;김갑중;김상하;박혜미;유세종
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.171-177
    • /
    • 2024
  • 본 연구에서는 대전지역 종합병원 중 일반촬영장치, CT, MRI 검사 장치 각 2대씩 선정하여 시간대 별 검사 장치의 표면오염도를 측정하여 감염도를 예측하고 감염 예방을 위한 기초자료로 활용하고자 실험을 하였다. 그 결과 일반촬영장치와 MRI 검사장치의 시간대 별 표면 오염도는 13시>8시>16시 순이였으며, CT검사 장치는 13시>16시>8시 순이었으며 이는 검사 건수의 영향으로 나타났다. 또한 검사 장치 부위 별 표면 오염도 결과는 일반촬영장치는 Stand Bucky 손잡이, CT 검사장치는 머리받침대, MRI 검사 장치는 조작 스위치에서 ATP 오염도 수치가 가장 많이 나왔으며, 이는 접촉 건수와 밀접한 관계가 있었다. 소독 전후를 비교한 결과 소독 후 모든 장치에서 유의한 차이로 감소한 결과를 보였다. 실험 결과를 바탕으로 영상의학과 검사실의 오염도를 파악하고 감염질환을 예방할 수 있는 기초자료가 될 수 있을 것이라고 사료된다.