A Study on Surface Etching of Metallic Co and Mo in R.F. Plasma (RF 플라즈마를 이용한 금속 코발트와 몰리브데늄의 표면 식각 연구)

  • 서용대;김용수;정종헌;오원진
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.1
    • /
    • pp.10-16
    • /
    • 2001
  • Recently plasma etching research has been focused on the metal surfaces in the nuclear industry. In this study, surface etching reaction of metallic Co and Mo, principal contaminants in the spent nuclear components, in CF$_4$/O$_2$, gas plasma has been experimentally investigated to look into the applicability and the effectiveness of the technique for the surface decontamination. Experimental variables are $CF_4$/$O_2$ ratio and substrate temperature between 29$0^{\circ}C$ and 38$0^{\circ}C$. Experimental results Show that the optimum gas composition is 80%CF$_4$-20%$O_2$ and the metallic Co and Mo are etched out well enough in the temperatures range. Cobalt starts to be etched above $350^{\circ}C$ and the etching rate increases with increasing substrate temperature. Maximum rate achieved at 38$0^{\circ}C$ under 220 W r.f. plasma power is 0.06 $\mu\textrm{m}$/min. On the other hand, the metallic Mo is etched easily even at low temperature and the reaction rate drastically increases as the substrate temperature goes up. Highest rate obtained under the same conditions is $1.9\mu\textrm{m}$/min. OES (Optical Emission Spectroscopy) analysis reveals that the intensities of F atom and CO molecule reach maximum at the optimum gas composition, which demonstrates that the principal reaction mechanism is fluorination and/or carbonyl reaction. It is confirmed, therefore, that dry processing technique using reactive plasma is quite feasible and applicable for the decontamination of surface-contaminated parts or equipments.

  • PDF

Decontamination Characteristics of 304 Stainless Steel Surfaces by a Q-switched Nd:YAG Laser at 532 nm (532 nm 파장의 큐스위치 Nd:YAG 레이저를 이용한 스테인리스 스틸 표면 제염특성)

  • Moon, Jei-Kwon;Baigalmaa, Byambatseren;Won, Hui-Jun;Lee, Kune-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.181-188
    • /
    • 2010
  • Metal surface decontamination characteristics were investigated by using a laser ablation method. A second harmonic generation of a Q-switched Nd:YAG laser with a wave length of 532 nm, a pulse energy of 150 mJ and a pulse width of 5 ns was employed to assess the decontamination performance for metal surfaces contaminated with $CsNO_3$, $Co(NH_4)_2(SO_4)_2$, $Eu_2O_3$ and $CeO_2$. The ablation behavior was investigated for the decontamination variables such as a number of laser shots, laser fluence and an irradiation angle. Their optimum values were found to be 8, 13.3 J/$cm^2$ and $30^{\circ}$, respectively. The decontamination efficiency was different depending on the kinds of the contaminated ions, due to their different melting and boiling points and was in the order: $CsNO_3>Co(NH_4)_2(SO_4)_2>Eu_2O_3>CeO_2$. We also evaluated a correlation between the metal ablation thickness and the number of laser shots for the different laser fluences.

CHEMICAL DECONTAMINATION OF SOIL CONTAMINATED WITH Cs-137

  • H. J. Won;Kim, G. N.;C. H. Jung;Park, W. K.;Kim, M. G.;W. Z. Oh;Park, J. H.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.83-95
    • /
    • 2004
  • The removal efficiency of several washing agents on the $Cs^+$ ion was investigated. Leaching of $Cs^+$ ion from the soil surface by washing agents is affected by the exchange capability of the washing solution. Reuse tests of the effective soil washing agents such as $BaCl_2$, NaOH, citric acid+ $HNO_3$ and oxalic acid were performed. NaOH, citric acid + $HNO_3$ and oxalic acid solutions can be reused after passing through the ion exchange column. Among the tested solutions, both of citric acid+ $HNO_3$ and oxalic acid were effective for the decontamination of TRIGA research reactor soil. The radioactivity of soils can be reduced to a release level by the successive application.

  • PDF

Application of Gaseous Ozone for Cleaning Biological Weapon Agent Contaminated Building (생물테러시 실내제독을 위한 효율적인 오존가스의 적용 방법)

  • Yoon, Je-Yong;Jeong, Woo-Dong;Mun, Sung-Min;Cho, Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.101-108
    • /
    • 2008
  • This study attempted to develop the technology by gaseous ozone for decontaminating building affected by a model of biological weapon agent(Bacillus subtilis spores) instead of Bacillus anthracis spore. The use of ozone is attractive method from a practical point of view of decontamination procedure since it has strong oxidation power but no residue after application. We examined the disinfection efficiency of gaseous ozone to Bacillus subtilis spores which suspension was sprayed on different material surfaces and dried. Three different types of gaseous ozone was applied : dry ozone, dry ozone with humidified air, and water bubbled wet ozone. Dry ozone(1500ppm) failed to achieve any significant inactivation for 2hrs. However, six log reduction of B. subtilis spore was achieved within 30min by 1500ppm of water bubbled wet ozone. This result shows the noticeable inactivation efficiency by gaseous ozone compared with previous studies. Good performance by wet ozone was also found for military material surface.(i.e. : gas mask hood, protective garments, army peinted metal surface).

Effect of Spinal Cord Removal before or after Splitting and Washing on CNST Decontamination of Beef Carcasses

  • Lim, D.G.;Kim, D.H.;Lee, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1770-1776
    • /
    • 2007
  • Beef carcasses were examined to explore the effects of spinal cord removal and washing on central nervous system tissue (CNST) decontamination of the surface during the slaughtering process. A total of 15 carcasses were split by sawing centrally down the vertebral column and left sides of split carcasses were used for analysis. Samples were collected by swabbing the surface from 4 defined parts on the interior and 4 on the exterior of carcasses from the abattoir and analyzed using an ELISA-based test. The results showed that automatic and manual spray washing decreased CNST contamination, especially on the interior ventral parts of carcass surfaces (p<0.01), but did not decrease CNST on the interior dorsal parts. Increasing washing time to 60 s did not affect the reduction of CNST contamination. Samples following spinal cord removal prior to splitting showed lower calculated levels of "risk material" than the stated limit of detection (0.1%) of the ELISA kit on interior and exterior carcass parts (p<0.01). Therefore, spinal cord removal prior to splitting could be a very effective way to minimize CNST contamination of beef carcasses.

Acceptable Decontamination Factor for Near-Surface Disposal of PEACER Wastes

  • Kim, Sung-Il;Lee, Kun-Jai
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.280-289
    • /
    • 2005
  • A pyrochemical process has been introduced and utilized so that the transmutation of spent PWR fuel in PEACER can produce mainly low and intermediate level waste for near surface disposal. Major radioactive nuclides from PEACER pyroprocessing are composed of TRU and LLFP. In this study, the requirement for the final waste from PEACER is evaluated based on the methodology for establishment of waste acceptance criteria. Also, sensitivity analysis for several input parameters is conducted in order to determine acceptable decontamination factor (DF) and LLFP removal efficiency and to find out input parameter that extremely have an effect on DE As a result of the study, LLFP removal efficiency, especially Sr-90 and Tc-99, is proved to be a major nuclide which contributes to annual dose by human intrusion scenario rather than TRU DF. More than $98.5\%$ of LLFP have to be removed to meet below dose constraint within the DF more than 5.0E+03. Besides, because of the relative short half-life of Sr-90, the increasing of the institutional control period is recommended for most important input parameter to determine DF.