• 제목/요약/키워드: Surface area measurement

검색결과 685건 처리시간 0.03초

방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발 (Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device)

  • 진동식;김경령;이재근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

Thickness Measurement of a Transparent Thin Film Using Phase Change in White-Light Phase-Shift Interferometry

  • Kim, Jaeho;Kim, Kwangrak;Pahk, Heui Jae
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.505-513
    • /
    • 2017
  • Measuring the thickness of thin films is strongly required in the display industry. In recent years, as the size of a pattern has become smaller, the substrate has become larger. Consequently, measuring the thickness of the thin film over a wide area with low spatial sampling size has become a key technique of manufacturing-yield management. Interferometry is a well-known metrology technique that offers low spatial sampling size and the ability to measure a wide area; however, there are some limitations in measuring the thickness of the thin film. This paper proposes a method to calculate the thickness of the thin film in the following two steps: first, pre-estimation of the thickness with the phase at the peak position of the interferogram at the bottom surface of the thin film, using white-light phase-shift interferometry; second, accurate correction of the measurement by fitting the interferogram with the theoretical pattern through the estimated thickness. Feasibility and accuracy of the method has been verified by comparing measured values of photoresist pattern samples, manufactured with the halftone display process, to those measured by AFM. As a result, an area of $880{\times}640$ pixels could be measured in 3 seconds, with a measurement error of less than 12%.

위상대조도 MRI에서 숙임각에 따른 상행대동맥의 혈류 측정 (Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta)

  • 김문선;권대철
    • 한국자기학회지
    • /
    • 제26권4호
    • /
    • pp.142-148
    • /
    • 2016
  • 자기공명영상에서 위상대조(phase contrast; PC) 기법으로 혈류 속도와 혈류량을 정량적으로 측정하기 위해 VENC(150 cm/s)에서 숙임각의 변화에 따른 혈류 속도와 혈류량을 측정하였다. 1.5T MRI로 지원자 17명(여: 8, 남: 9, 평균연령 $57.9{\pm}15.4$)을 대상으로 non-breath holding 기법을 적용하여 상행대동맥에서 VENC(150 cm/s)로 숙임각을 $20^{\circ}$, $30^{\circ}$, $40^{\circ}$ 변화하여 측정하였다. 혈류는 average velocity, peak velocity, net forward volume, net forward volume/body surface area를 획득하였다. 상행대동맥에서 AV(average velocity)의 평균값은 숙임각 $20^{\circ}$(9.87 cm/s), $30^{\circ}$(9.6 cm/s), $40^{\circ}$(10.05 cm/s)로 측정되었다. 숙임각을 $20^{\circ}$, $30^{\circ}$, $40^{\circ}$에서 peak velocity, average velocity, net forward volume, net forward volume/body surface area는 통계적인 유의한 차이가 없었다(p > .05). 혈류속도와 혈류량 측정은 매개변수를 조정하여 적용하면 심장혈관 질환의 진단 및 치료에 중요한 정보가 되는 혈류량을 정확히 계산하고, 혈류량 측정에 관한 연구에 도움을 줄 수 있다.

A Study of the Electrical Properties of the Buccal Area using Facial Surface Electromyography

  • Choi, Yoo Min;Kim, Jong Uk;Kim, Lak Hyung;Yook, Tae Han
    • Journal of Acupuncture Research
    • /
    • 제34권2호
    • /
    • pp.75-82
    • /
    • 2017
  • Objectives : The purpose of this study was to determine the electrical properties of the buccal area using facial surface electromyography (sEMG). Methods : This research was conducted on 44 healthy participants irrespective of their sex. Surface electrodes were attached to the midpoints of three imaginary lines connecting ST4 (Dicang) to ST6 (Jiache), ST4 to SI18 (Quanliao), and ST4 to the center point of SI18 and ST6. Then, the participants were trained in the movement that included a comprehensive action of buccal area. While the participants were performing the motion, sEMG values ($E_1$, $E_2$, $E_3$) and the distance change of the three imaginary lines ($D_1$, $D_2$, $D_3$) were measured. The data were statistically analyzed using SPSS ver. 22.0. Results : Significant differences were observed in the distance changes ($D_1$>$D_3$, $D_2$>$D_3$) and sEMG values ($E_1$<$E_2$<$E_3$). Moreover, there were positive correlations between $D_1$ and $E_1$, $D_2$ and $E_2$. Conclusion : We suggest that the measurement at ST4 to the center point of ST6 and SI18 with this motion would be adequate to check the electrical characteristics of the buccal area.

애자 표면열화에 의한 방전특성과 ICP-AES 분석 (The discharge characteristics and ICP-AES analysis of insulators by surface deterioration)

  • 송길목;김영석;정진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1408_1409
    • /
    • 2009
  • It's described the discharge characteristics and ICP-AES analysis of insulators by surface deterioration in this paper. For the assessment of insulators, there are applied the conductivity of dusts, contact angle measurement of the insulator surfaces and the ingredient analysis in each area. Through the analysis of pollutants attached to insulators inside the tunnel, the cleaning cycle is discussed. As the results, it would be expected to the electrical safety.

  • PDF

두상의 표면적 측정 방안 (A surface area measurement techniques for the human head and face)

  • 이근부
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1996년도 춘계공동학술대회논문집; 공군사관학교, 청주; 26-27 Apr. 1996
    • /
    • pp.655-657
    • /
    • 1996
  • In this study, the methods and equipment that can be used to detail the anthropomorphic data were developed. This new method that utilizes the Moire' interferometry and image processing technique is less expensive than the conventional methods. We took 36 subjects (18 years to 28 years old). The face area was calculated based on contour information. The cluster analysis about those data enables us to classify our subjects into four groups.

  • PDF

Sentinel-1 위성영상을 활용한 소규모 저수지 저수량 추정 (Estimation of Small Reservoir Storage Using Sentinel-1 Image)

  • 장문엽;송주일;장초록;김한태
    • 한국재난정보학회 논문집
    • /
    • 제16권1호
    • /
    • pp.79-86
    • /
    • 2020
  • 연구목적: 본 연구에서는 Sentinel-1 위성이 촬영한 영상을 활용하여 천안지역 저수지의 저수량을 추정하는 모형을 개발하였다. 연구방법: 총 3개의 저수지를 대상으로 연구를 진행하였으며, 3개 저수지 모두 수위가 계측되고 있는 소규모 저수지이다. Sentinel-1 영상의 전 처리는 유럽항공우주국(ESA, European Space Agency)에서 배포한 SNAP을 활용하였으며, 임계치 분류 방식에 의해 수체를 구분하여 저수면적을 추정하였다. 추정한 저수면적에 대해서는 인공위성이 촬영한 날짜와 동일한 날짜에 드론으로 촬영하여 저수면적을 비교하였다. 저수지 저수면적을 추정한 것과 관측유량 자료와의 관계식을 도출하여 저수량 추정모형을 구축하였다. 연구 결과 및 결론: 위성영상분석을 통해 추정한 저수량 값은 실제 계측자료와 유사한 값을 가지는 것을 확인할 수 있었다. 다만, 여름철 저수지의 녹조, 부착돌말류 등으로 인해 저수면적의 과소 추정과 위성영상 해상도로 인한 저수면적이 10,000㎡ 이하인 저수지는 위성영상으로는 탐지가 어려운 문제점이 존재하는 것을 확인하였다.