• 제목/요약/키워드: Surface acidity

검색결과 313건 처리시간 0.025초

충북 청원군의 안개, 이슬, 서리의 산성도 연구 (An Acidity Study of Fog, Dew and Frost Observed in Chongwon, Choongbook)

  • 정용승;김태군
    • 한국대기환경학회지
    • /
    • 제8권1호
    • /
    • pp.45-51
    • /
    • 1992
  • A study on acidity in fog, dew and frost was carried out. Samples were taken during May 1990-February 1991 at two sites in Chongwon, Choongbook. The acidity of dew and of fog collected from grass at site A was 4.89 and 5.46, respectively. Dew in summer showed very strong acidity. The volume of dew deposited on grass was much less than the volume of rain, but dew is effective to diffuse acid predursors and acid materials. Dew and fog can remove more effectively atmospheric acid materiasl deoposited on grass by diurnal turbulent motion rather than direct absorption of acid predursors and materials in the atmosphere. In a polluted area, acidic dew and fog can be occurred by the direct absorption and oxidation of acidic predursors in the atmosphere as well as the role of wet removal on grass surface. Acidity of frost collected on teflon surface showed little difference to acidity of dew and fog on teflon surface. This suggests a similar absorption mechanism of atmospheric precursors and materials into dew and frost in the atmosphere. Strong acidity in dew, fog and frost appeared to occur from local pollution sources of several ten kilometres. In particular, strong acidity in dew, fog, and frost together with acid rain can accelerate a damage in ecosystems. Discussion is made on scientific analyses and seasonal variations of acidity of fog, dew and frost. A mechanism on acidification of fog, dew and frost is also discussed.

  • PDF

Characterizations of Membrane for Water Treatment: Surface Charge Analysis by Electrophoresis and Acidity Measurements

  • Yongki Shim;Lee, Sangyoup;Moon, Seung-Hyeon;Jaeweon Cho
    • Korean Membrane Journal
    • /
    • 제2권1호
    • /
    • pp.56-59
    • /
    • 2000
  • The surface charge properties of a polymeric NF and a ceramic UF membranes were characterized in terms of zeta potential and acidity. Both the negative zeta potential and acidity values increased as pH increases due to ionizable acidic functional groups. Increased ionic strength reduced the acidity of the negatively-charged membrane surface as anticipated. Through these results, it can be envisioned are used to reject solutes with ionizable functional groups. Fouling of the negatively-charged membrane with natural organic matter (NOM) having a negative charge density was also investigated with respect to the surface charge. The surface charge of the NF membrane increased negatively when greater NOM adsorption onto the membrane surface occured.

  • PDF

콜로이드 실리카 종류와 산도영향에 따른 졸겔코팅제 특성연구 (Properties of Sol-Gel Materials Synthesized According to Kinds of Colloidal Silica and Acidity)

  • 강동필;안명상;나문경;명인혜;강영택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.1927-1929
    • /
    • 2005
  • Colloidal Silica(CS)/methyltrimethoxy silane(MTMS) sol solutions were prepared in variation with synthesizing parameters such as kinds of CS, acidity and reaction time. In order to understand its surface properties, sol-gel coating films on glass were fabricated. The coating film obtained from CS/MTMS sol had stable contact angle and more enhanced flat surface at reaction time of 24 hours. In case of the initial and final period of reaction, the coating films had unstable contact angle and more rough surface. In addition, surface of CS/MTMS sol-gel coating film was more rougher with increasing of acidity.

  • PDF

Investigation of the Effect of Acidity and Polyethylene Glycol on Electrochemical Deposition of Trivalent Chromium Ions

  • Phuong, N.V.;Kwon, S.C.;Lee, J.Y.;Kim, M.;Lee, Y.I.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2011년도 춘계학술대회 및 Fine pattern PCB 표면 처리 기술 워크샵
    • /
    • pp.47-48
    • /
    • 2011
  • The effect of solution acidity and organic additives, polyethylene glycol (PEG), on the trivalent chromium electroplating was systematically investigated in the view point of solution stability, electroreduction of trivalent chromium ions and characterization of deposition layer. It was found that, the concentration of fraction chromium complexes in the trivalent chromium bath containing formic acid is strongly depended on pH value. PEG molecules were stable in trivalent chromium bath containing formic acid via studies on electrospray ionization mass spectrometry (ESI-MS) and UV-Vis. However, the presence of PEG molecules decreased the reductive current of hydrogen evolution, increasing of current efficiency higher about 10 % compared with solutions without PEG. Moreover, PEG additives developed the nodular morphology during electroreduction of trivalent chromium ions with the increase of solution acidity and enhanced its current efficiency by maintaining the consumption of complexant, formic acid, at a low speed. In this study, the effect of solution acidity was emphasized important, there, it controlled the formation of complexes in the solution, cathodic film (CF) during deposition, and properties of deposited layer. By electrochemical quartz crystal microbalance (EQCM), studies show that chromium electrodeposition occurs via the formation of intermediate complexes and adsorption on the cathode surface, which hinder the penetration of ions from bulk solution to the cathode surface.

  • PDF

한지의 산성도 측정을 위한 비파괴적 방법의 적용 (The application of a nondestructive method to measure the acidity of Korean papers)

  • 이혜윤;정용재;이규식;한성희
    • 보존과학연구
    • /
    • 통권20호
    • /
    • pp.21-47
    • /
    • 1999
  • According to damage of papers by the chemical cause, papers become to acidify. Among the 3 kinds of method measuring the acidity of paper, one was nondestructive method measuring the surface of the paper by flat type electrode and the others were destructive methods measuring directly by cold water extract method and hot water extract method. In case of the cellulolytic cultural properties, the latter methods were not applied because those methods must bedissociated papers. To measure the paper acidity nondestructively, we investigated the correlation of the nondestructive method and the destructive methods. The conclusions are as follows. 1) In the relationship of the cold water extract method and the hot water extract method, It was indicated that the pH measured by the hot water extract method was high quality printing paper 0.08, rough printing paper 0.13, and Korean paper 0.29 higher than that by the cold water extract method.2) In the relationship of the cold water extract method and the surface measurement method, It showed that the pH value measured by the cold water extract method was high quality printing paper 1.86, rough printing paper 0.80,and Korean paper 0.58 higher than value that by the surface measurement.3) In the relationship of the hot water extract method and the surface measurement method, It showed that the pH value measured by the hot ABSTRACT water extract method was high quality printing paper 1.78, rough printing paper 0.66, and Korean paper 0.29 higher than that by the surface measurement. From the above-mentioned results, the pH value measured by the surface measurement was need to high about 1.78∼1.86 in high quality printing paper, 0.66-0.80 in rough printing paper, and 0.29∼0.58 in Korean paper and the surface measurement with flat type electrode was very available to measure the acidity of Korean papers actually.

  • PDF

Effect of Dentin Bonding Agent Acidity on Surface Microhardness of Mineral Trioxide Aggregate

  • Yun-Hui Im;Yoon Lee
    • Journal of Korean Dental Science
    • /
    • 제17권1호
    • /
    • pp.36-44
    • /
    • 2024
  • Purpose: This study investigated the effect of dentin bonding agent acidity on surface microhardness of MTA. Materials and Methods: Forty cylindrical molds (3 mm×5 mm) were prepared, and three dentin bonding agents with different acidities: Adper Single Bond 2 (ASB), Single Bond Universal (SBU), and Clearfil SE bond 2 (CSE) were applied to the inner surface of the molds (n=10). No bonding agent was applied in the control group. MTA was mixed and inserted into the molds and sealed with a wet cotton pellet for 4 days. After setting, the Vickers microhardness (HV) test was done at 200, 400, 600 ㎛ from the inner surface of the mold. One-way ANOVA was conducted for all samples. A P-value of less than .05 was considered significant. Tukey HSD test was performed for post-hoc analysis. Results: The mean HV values and standard deviations were 67.02±11.38 (Con), 48.76±11.33 (ASB), 43.78±11.19 (CSE), 37.84±9.36 (SBU), respectively. The difference between the control group and the experimental groups was statistically significant (P<0.001). The difference between ASB and SBU was statistically significant (P<0.001), while the difference between SBU and CSE was not. There were no statistically significant differences between the various points from the inner surface of the mold within each group (P>0.05). Conclusion: Results of the current study indicate that use of dentin bonding agents with MTA can reduce the surface microhardness of MTA. Moreover, there is a direct relationship between the acidity of dentin bonding agents and the surface microhardness of MTA.

3가크롬 이온의 전착 반응에 용액 산도 및 유기물 첨가제가 미치는 영향 연구 (Investigation of the Effect of Solution Acidity and Organic Additives on the Electrodeposition of Trivalent Chromium Ions)

  • 이주열;;강대근;김만;권식철
    • 한국표면공학회지
    • /
    • 제43권6호
    • /
    • pp.297-303
    • /
    • 2010
  • The effect of solution acidity and organic additives, polyethylene glycol (PEG), on the trivalent chromium electroplating was systematically investigated in the view point of electroreduction of trivalent chromium ions and solution stability. It was found that solution acidity controlled at pH 2.5 showed the widest current range for bright electrodeposits in the presence of PEG additives, which reduced the local current intensification at high current densities. Through complex interaction between PEG additives and hydrogen ion, that is, solution acidity, electrode potential was moved in the negative direction in the bulk solution, while it shifted in the positive when electric potential was scanned. In conjunction with electrochemical quartz crystal microbalance (EQCM), it was found that PEG additives had a role in promoting the electron transfer to trivalent chromium ion complexes in bulk solution and their adsorption at the electrode surface as well as interfering with hydrogen ion reduction process below pH 2.5. The PEG additives developed the nodular morphology during electroreduction of trivalent chromium ions with the increase of solution acidity and enhanced its current efficiency by maintaining the consumption of complexant, formic acid, at low speed.

탄약 표면 처리용 아연계 인산염 피막의 중량 및 내식성에 관한 연구 (Study on the coating weight and corrosion resistance of Zinc phosphate for surface treatment of ammunition)

  • 김명현;이승용;이현희;이영태
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.603-610
    • /
    • 2017
  • 탄약을 포함한 다양한 산업 분야에서 사용되는 철강 재료는 부식에 취약하므로, 표면 그대로 사용하는 것은 바람직하지 않다. 따라서 도금, 도장, 화성처리와 같은 표면 처리 이후 사용하여야 하는데, 탄약 제조 과정에서는 주로 아연계 인산염 피막 처리가 사용되고 있다. 표면 처리 기법 중 하나인 아연계 인산염 피막은 금속 표면을 화학적으로 처리하여 안정성이 높은 화합물 층을 표면에 고착시키는 방법으로, 크게 도장 하지용 경인산염 피막과 부식 방지용 중인산염 피막으로 나뉘어지는데, 아연계 인산염 피막은 전산도, 철 함량과 같은 여러 가지 인자에 의해 피막의 품질과 내식성이 결정된다. 본 연구에서는 전산도 및 철 함량이 탄약 부식 방지 목적으로 사용되는 아연계 중인산염 피막의 중량 및 내식성에 미치는 영향에 대하여 알아보았다. 철 함량에 따라 피막의 구조가 치밀해지며, 내식성이 향상되는 결과를 확인할 수 있었으나, 전산도는 피막의 두께와 중량에만 영향을 주고 내식성에는 큰 영향을 주지 못하였다. 위 결과를 토대로 탄약 제조 과정에서 사용되는 인산염 피막 처리 공정의 최적 제어 수준을 제시하였다.

발굴현장 수습 유물 보존처리 (On-site conservation of a gilt bronze crown)

  • 유재은
    • 보존과학연구
    • /
    • 통권20호
    • /
    • pp.49-64
    • /
    • 1999
  • According to damage of papers by the chemical cause, papers become to acidify. Among the 3 kinds of method measuring the acidity of paper, one was nondestructive method measuring the surface of the paper by flat type electrode and the others were destructive methods measuring directly by cold water extract method and hot water extract method. In case of the cellulolytic cultural properties, the latter methods were not applied because those methods must bedissociated papers. To measure the paper acidity nondestructively, we investigated the correlation of the nondestructive method and the destructive methods. The conclusions are as follows. 1) In the relationship of the cold water extract method and the hot water extract method, It was indicated that the pH measured by the hot water extract method was high quality printing paper 0.08, rough printing paper 0.13, and Korean paper 0.29 higher than that by the cold water extract method.2) In the relationship of the cold water extract method and the surface measurement method, It showed that the pH value measured by the cold water extract method was high quality printing paper 1.86, rough printing paper 0.80,and Korean paper 0.58 higher than value that by the surface measurement.3) In the relationship of the hot water extract method and the surface measurement method, It showed that the pH value measured by the hot ABSTRACT water extract method was high quality printing paper 1.78, rough printing paper 0.66, and Korean paper 0.29 higher than that by the surface measurement. From the above-mentioned results, the pH value measured by the surface measurement was need to high about 1.78∼1.86 in high quality printing paper, 0.66-0.80 in rough printing paper, and 0.29∼0.58 in Korean paper and the surface measurement with flat type electrode was very available to measure the acidity of Korean papers actually.

  • PDF