• 제목/요약/키워드: Surface Topography

검색결과 679건 처리시간 0.029초

Cell Adhesion and Growth on Nanostructured Surface

  • Yoon, Seo Young;Park, Yi-Seul;Choi, Sung-Eun;Jung, Da Hee;Lee, Jin Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.93-93
    • /
    • 2013
  • To make the rationale design of interface between cell and artificial surface, many studies have been controlled influencing cue which can typically be divided into two central categories: chemical cues based on modification surface chemical properties containing attractive/repulsive molecules, and physical cues that may include applied tension/stress, electrical polarization, magnetic field, and topography. Recently, researches have been focused on physical cue, especially topography. The surface topography may influence cellular responses for example, cell adhesion, cell morphology and gene expression. However, there were few systematic studies about these nanotopographical effects on neuronal developments in a feature size-dependent manner. Herein, we report a nanoscale-resolved study of nanotopographical effects on cellular adhesion and growth. In this study, we use substrates with packed glass beads by rubbing method for generating highly periodic nanotopographies with various sizes. We found that acceleration of neuritogenesis appeared only on the beads larger than 200 nm in diameter, and observed that filopodial thickness was comparable with this scale. This study is expected to be essential to elucidate the nanotopographical effect on cellular adhesion and growth.

  • PDF

삼차원 표면 조도 측정기와 삼차원 레이저 공초점 현미경 적용에 따른 표면 거칠기에 대한 영향 연구 (Study of the Effect of Surface Roughness through the Application of 3D Profiler and 3D Laser Confocal Microscope)

  • 정희영;김대은
    • Tribology and Lubricants
    • /
    • 제40권2호
    • /
    • pp.47-53
    • /
    • 2024
  • Surface topography plays a decisive role in determining the performance of several precision components. In particular, the surface roughness of semiconductor devices affects the precision of the circuit. In this regard, the surface topography of a given surface needs to be appropriately assessed. Typically, the average roughness is used as one of the main indicators of surface finish quality because it is influenced by both dynamic and static parameters. Owing to the increasing demand for such accurate and reliable surface measurement systems, studies are continuously being conducted to understand the parameters of surface roughness and measure the average roughness with high reliability. However, the differences in the measurement methods of surface roughness are not clearly understood. Hence, in this study, the surface roughness of the back of a silicon wafer was measured using both contact and noncontact methods. Subsequently, a comparative analysis was conducted according to various surface roughness parameters to identify the differences in surface roughness depending on the measurement method. When using a 3D laser confocal microscope, even smaller surface asperities can be measured compared with the use of a 3D profiler. The results are expected to improve the understanding of the surface roughness characteristics of precision components and be used as a useful guideline for selecting the measurement method for surface topography assessment.

표면거칠기를 고려한 평행 스러스트 베어링의 혼합윤활 해석 (Mixed Lubrication Analysis of Parallel Thrust Bearing by Surface Topography)

  • 이동길;임윤철
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.134-141
    • /
    • 2000
  • The real area of contacts, average film thickness, mean real pressure, and mean hydrodynamic pressure are investigated numerically in this study, especially for the parallel thrust bearing. Model surface is generated numerically with given autocorrelation function and some surface profile parameters. Then the average Reynolds equation contained flow factors and contact factor is applied to predict the effects of surface roughness in mixed lubrication regimes. In this equation, flow factors are defined as correction terms to smooth out high frequency surface roughness and contact factor is introduced to relieve from obtaining the average film thickness. Therefore the computation time to obtain h can be reduced.

  • PDF

액체 보조 엑시머 레이저 미세가공 공정 (Excimer laser micromachining process assisted by liquid)

  • 장덕석;김동식
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.60-65
    • /
    • 2006
  • Previous studies demonstrated that laser ablation under transparent liquid can result in ablation enhacement and particle removal from the surface. In this work, the liquid-assisted excimer laser ablation process is examined fer polyethylene terephthalate (PET), polymethyl methacrylate (PMMA), Si, and alumina with emphasis on ablation enhacement, surface topography, and debris formation. In the case of PET and PMMA, the effect of liquid is analyzed both fer thin water film and bulk water. As the ablation enhanement by liquid is already known for Si and alumina, the analysis focuses on surface topography and debris formation resulting from the liquid-assisted laser ablation process. The results show that application of liquid increases the ablation rate of PMMA while that of PET remains unchanged even in the liquid-assisted process. It is also revealed that the liquid can significantly improve the surface quality by reducing the debris deposition. However, the surface roughness is generally deteriorated in the liquid-assisted process. The surface toporaphy is found to be strongly dependent on the method of liquid application, i.e., thin film or bulk liquid.

  • PDF

유체역학 현상을 이용한 현미경 검사법 개발 (A Scanning Flow Impedance Micrscope)

  • 김태영;김동권;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2670-2675
    • /
    • 2008
  • We introduce a new type of surface microscope using hydrodynamic phenomena. The fluid flow through the opening of the pipette probe is blocked at short distances between the probe and the surface, thus increasing the pressure loss. Therefore, a scanning flow impedance microscope (SFIM) can image the surface topology by scanning the probe with measuring the pressure loss. The SFIM can display the topology regardless of surface hardness, surface electrical conductivity, and surrounding fluid. The present letter contains the first experimental results on surface topography obtained with this novel microscope. The preliminary results in air demonstrate the lateral resolution of the SFIM is very close to the inner diameter of the probe.

  • PDF

대기 안정도와 지표면 온도가 미세규모 국지 흐름에 미치는 영향: 수문지역을 대상으로 (Effects of Atmospheric Stability and Surface Temperature on Microscale Local Airflow in a Hydrological Suburban Area)

  • 박수진;김도용;김재진
    • 대기
    • /
    • 제23권1호
    • /
    • pp.13-21
    • /
    • 2013
  • In this study, the effects of atmospheric stability and surface temperature on the microscale local airflow are investigated in a hydrological suburban area using a computational fluid dynamics (CFD) model. The model domain includes the river and industrial complex for analyzing the effect of water system and topography on local airflow. The surface boundary condition is constructed using a geographic information system (GIS) data in order to more accurately build topography and buildings. In the control experiment, it is shown that the topography and buildings mainly determine the microscale airflow (wind speed and wind direction). The sensitivity experiments of atmospheric stability (neutral, stable, and unstable conditions) represent the slight changes in wind speed with the increase in vertical temperature gradient. The differential heating of ground and water surfaces influences on the local meteorological factors such as air temperature, heat flow, and airflow. These results consequentially suggest that the meteorological impact assessment is accompanied by the changes of background land and atmospheric conditions. It is also demonstrated that the numerical experiments with very high spatial resolution can be useful for understanding microscale local meteorology.

머신비전을 이용한 밸브어셈블리의 3차원 마멸특성 분석 (3D Wear Analysis of Valve Assemblies by Using the Machine Vision)

  • 박창우;정성종
    • 대한기계학회논문집A
    • /
    • 제30권5호
    • /
    • pp.496-504
    • /
    • 2006
  • Wear of engine valves and seat inserts is a major factor affecting engine performance. In order to improve quality and life of valve assemblies, wear mechanism and 3-D surface topography should be analyzed according to operating conditions of the engine. After developing an engine simulator that generates valve speed up to 90Hz and temperature up to $900^{\circ}C$ as well as controls test load, wear experiments have been conducted for two different engine speeds as 10Hz and 25Hz. In order to observe the wear characteristics and monitor surface conditions of the valve assemblies, a cost-effective 3-D wear analysis system based on the shape from focus(SFF) and machine vision has been fabricated in this paper. 3-D surface topography of the valve assemblies has been analyzed to understand the wear behavior according to operating conditions of the engine. Consequently, wear volume of the valve assemblies is quantized by using the developed 3-D wear analysis system.

모아레 체형측정법이 청소년기 척추측만증의 조기집단검진 활용 가능성에 대한 평가 (Application of 3-Dimensional MOIRE Topography to the School Screening Program for Adolescent Scoliosis)

  • 한명금;신병철
    • 대한추나의학회지
    • /
    • 제4권1호
    • /
    • pp.1-16
    • /
    • 2003
  • Objectives : The purpose of this study is researching for possibility that Moire topography be applied in group school screening for scoliosis known school health problem, and find acceptable method of early detection and early treatment for scoliosis Methods : The authors practiced Moire topography for primary & middle school 1,895 students[male 976, female 919] in Jeonju, korea in 2001. After we distinguished students who had abnormal finding in Moire topography and then re-examined spinal X-ray analysis. The data was analysed and evaluated statistically Results : According to this research, the abnormal finding in Moire topography was 53.7% (1,018 students), and students needed X-ray re-examination were 11.2% (213 students). Students diagnosed scoliosis by X-ray re-examination were 1.8%. According to statistical analysis, interval between vertical base line of pelvis and vertical base line of neck, gap between left distance and right distance to the vertical base line of pelvis and difference of contour lines have strong correlations with deformity degree of the body surface examined by Moire. Conclusions : Following this research, throughout early detection for scoliosis by Moire topography could reduce exposure from scoliosis radiographs, and could detect trunk asymmetry that couldn't be found existing X-ray examination, so it made selecting students under observation who have bad posture possible.

  • PDF