• 제목/요약/키워드: Surface Contamination Level

검색결과 161건 처리시간 0.025초

영산강 수계 표층 퇴적물의 금속류 분포 및 오염도 평가 (Assessment of Heavy Metal Pollution in Surface Sediments of the Yeongsan River)

  • 양해종;강태우;봉기문;정효진;양원준;한종학;정희정;황순홍;김경현
    • 환경분석과 독성보건
    • /
    • 제21권4호
    • /
    • pp.292-303
    • /
    • 2018
  • The particle sizes and heavy metal concentrations (Pb, Zn, Cu, Cd, Hg, As, Cr, Ni, Li, Al) of surface sediments of the Yeongsan River were analyzed to assess the distribution and pollution level of heavy metals. The distribution of particle sizes was dominated by sand in the upstream sites (MS1-MS7) and by silt loam in the downstream sites (MS8-ML3), but MS3 and MS6, located slightly upstream of the two weirs, were found to be loamy sand and silt loam, respectively. The concentrations of Pb, Zn, Cu, Cd and Hg were higher at the upstream sites, while As, Cr, Ni and Li were higher at the downstream sites. The heavy metals of crustal origin (As, Cr, Ni and Li) were strongly correlated with particle size, while the other heavy metals (Pb, Zn, Cu, Cd and Hg) were weakly correlated with particle size. Considering their concentrations, most of heavy metals were evaluated as having almost no toxic effects on benthic organisms, at all sites. In addition, anthropogenic contamination by the $I_{geo}$, EF and CF were found to have no impact at most sites, with only low levels of pollution at the others. Using the PLI method, the MS2 and MS3 sites, located upstream, were assessed to be affected by anthropogenic contamination. Most importantly, Zn, Cu and Hg were found to be the elements responsible for most pollution, and they were highest at the upstream sites, implying pollution by domestic sewage and urban discharge.

방사성 요오드 치료환자의 환의 및 시트에 대한 재사용주기 평가 (The Evaluation on Reuse Period of Patient's Clothes and Sheet After Radioiodine Therapy)

  • 김영선;서명덕;이완규;김기준;송재범
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.12-17
    • /
    • 2012
  • 방사성 요오드 치료병실에서 나온 환의 및 시트는 본디 방사성폐기물로서 관련 규정에 따라 일반 쓰레기와 동일하게 처리해야 하지만 사정상 일정기간 보관하여 방사능을 감쇄시킨 후 재사용하게 된다. 통상 최소보관기간 산출에 표면오염도(Bq/$m^2$)를 기반으로 하는 반출기준을 적용하고 있다. 하지만 방사선측정기를 이용하여 단위 면적당 총방사능량을 구하는 방법은 측정방법에 따라 편차와 불확실성이 상당히 커진다. 본 연구에서는 '방사성폐기물 자체처분 등에 관한 규정'에서 제시하고 있는 핵종 농도(Bq/g)를 Dose Calibrator를 이용하여 직접 측정하여 최소보관기간을 구함으로써, 환의 및 시트의 정확한 재사용 주기를 산출하고자 한다. 한편 반출기준으로 산출한 최소보관기간과 비교하여 그 차이를 살펴보았다. 본원의 방사성 요오드 치료병실에서 2011년 7월부터 2012년 3월까지 I-131을 3.7 GBq (100 mCi) 이상을 사용하여 방사성 요오드 치료를 시행한 환자 31명이 사용한 환의와 시트의 방사선 오염도를 측정하여 최소보관기간을 산출하였다. 최소보관기간은 핵종 농도를 측정하여 '방사성폐기물 자체처분 등에 관한 규정'에 따라 100 Bq/g이 되는 시점과 표면오염도를 측정하여 반출기준에 따라 허용표면오염도의 1/10, 즉 4 kBq/$m^2$되는 시점을 붕괴식에 대입하여 산출하였다. 반출기준으로 산출한 최소보관기간은 침대/담요시트는 14.2일, 베개시트는 4.6일, 환의(상(上))은 63일, 환의(하(下))는 78일 이었으며, 자체처분 기준에 따른 최소보관기간은 베개시트는 18.1일, 환의(상(上))은 43일, 환의(하(下))는 62일로 산출되었다. 표면오염도와 핵종 농도의 상관관계를 분석해 본 결과 베개시트와 환의(상(上))는 상관관계가 높게 나타났으나, 환의(하)는 낮게 나타났다. 이는 베개시트와 환의는 방사성오염이 부분에 국한 되어 측정값이 일정한 반면, 환의(하(下))는 소변에 의한 방사성오염이 여러 부분에 산재되어 있어 방사선측정기의 측정값이 상대적으로 낮게 측정된 결과로 생각 된다. 실질적으로 방사성 오염도를 측정한 결과 반출기준과 자체처분 기준을 상당량 초과하는 방사능이 존재하는 것을 확인할 수 있었다. 환의와 시트의 최소보관기간 산출에는 핵종 농도를 기준으로 하는 자체처분 기준을 적용하는 것이 더 적합하다고 할 수 있다. 방사능에 오염된 환의 및 시트는 최소 60일 정도는 보관해야 성급한 재사용에 따른 불필요한 방사선피폭 및 오염 확산을 방지할 수 있을 것으로 생각된다.

  • PDF

화장실 공기 중 미생물 분포 조사연구 (Assessment of Bioaerosols in Public Restrooms)

  • 김종규;김아혁;김중순
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.304-312
    • /
    • 2014
  • Objectives: This study was performed to examine bioaerosols in indoor air in public restrooms, as well as to assess the effects of air temperature and relative humidity on bioaerosol levels. Methods: A cross-sectional survey was performed in ten male and ten female restrooms. An air sampler (Anderson type) was used for sampling total suspended bacteria (TSB), Gram-negative bacteria (GNB), Gram-positive bacteria (GPB), opportunistic bacteria (OP), Staphylococcus spp., and total suspended fungi (TSF). Results: The levels of TSB were $10-10^2CFU/m^3$ and TSF $10-10^2CFU/m^3$, respectively. The GNB level was $0-10CFU/m^3$, and GPB and OP levels were $10-10^2CFU/m^3$. Staphylococcus aureus and methicillin-resistant S. aureus (MRSA) were detected in 90% of the restrooms. The GPB level was higher in the female restrooms than in the male restrooms (p < 0.05). TSB, GNB, and TSF showed higher levels in restrooms in buildings over 30 years old (p < 0.01). The main effect of air temperature or relative humidity and interaction effect of the two factors on the TSB level were significant (p < 0.05), while the effect of relative humidity on the TSF level was significant (p < 0.001). Conclusions: These results indicate that there is a wide variation in the bioaerosol levels among different restrooms. The observed differences in bioaerosol levels reflect different building histories. The effects of air temperature and/or relative humidity reveal that bioaerosol levels may vary according to season or time of day. Future research is needed to further characterize the relation between the bioaerosol levels and surface contamination in restrooms.

Good agricultural practices 모델 개발을 위한 양파 및 생산 환경에서의 위해요소 조사 (Investigation of Hazards from Onions and Their Cultivation Areas to Establish a Good Agricultural Practices (GAP) Model)

  • 최영동;이채원;김정숙;정덕화;심원보
    • 한국식품과학회지
    • /
    • 제45권6호
    • /
    • pp.785-790
    • /
    • 2013
  • The purpose of this study was to investigate the hazards from onions and their cultivation areas. A total of 32 samples were collected from onion farms and tested for biological (sanitary indicators, and pathogenic bacteria and fungi) and chemical (heavy metals and pesticide residues) hazards. Aerobic bacteria and coliforms were detected at a level of 0.2-7.1 log CFU/g (or mL) in the soil and agricultural water, 1.6-3.6 log CFU/g on surface of the onion, 0.0-6.0 log CFU/hand (or $cm^2$) on the workers' hands, clothes, and gloves, and 4.7 log $CFU/cm^2$ on the onion bags. Fungi were detected at a level of 0.0-5.0 log CFU/g (or mL, hand, or 100 $cm^2$) in all the samples. Staphylococcus aureus was detected at a level of 1.2 log CFU/hand on the workers' hands, the detection level of Bacillus cereus was up to 4.8 log CFU/g in the soil. However, Escherichia coli (and in particular strain O157:H7), Listeria monocytogenes, and Salmonella spp. were not detected. Although heavy metals were detected in the environment (in soil and agricultural water) and pesticide residues were detected in onion, the levels were lower than the regulation limits.

폐광산 오염원인 분석 및 오염경로, 향후 지속가능성에 대한 평가 (Assessment of the Cause and Pathway of Contamination and Sustainability in an Abandoned Mine)

  • 김민규;김기준;정교철
    • 지질공학
    • /
    • 제28권3호
    • /
    • pp.411-429
    • /
    • 2018
  • 대영광산(일명 대마광산)은 함금은석영맥을 주 대상으로 채광한 금 은광산으로, 주 광해유발요인은 광물찌꺼기 적치장, 폐석장, 갱구 등 이다. 광물찌꺼기 적치장의 주 오염원소는 As와 Pb이다. 특히 As의 경우 3,424.41~3,803.61 mg/kg로 1지역 대책기준의 45배 이상으로 As에 의한 오염이 매우 심각한 것으로 파악되었다. 오염원소를 보면 오염원인 광물찌꺼기가 고농도의 As를 함유하고 있으며, 오염원의 영향을 받는 주변의 매체에서도 공통적으로 As 오염이 확인되고 있다. 이러한 As 오염은 광물찌꺼기 적치장과의 지형적 상관성이나 이격거리에 따라 오염정도가 달라지는 특성을 나타낸다. 즉 광물찌꺼기 적치장의 상류지역은 하류지역에 비해 오염정도가 낮으며, 광물찌꺼기 적치장의 하류지역에서는 광물찌꺼기 적치장과의 거리가 멀어질수록 오염도가 낮아지는 경향을 보인다. 특히 광물찌꺼기 적치장 주변에서 고농도 오염이 집중적으로 나타나고 있다. 이러한 특성으로 볼 때, 연구지역의 주 오염경로 중의 하나는 광물찌꺼기의 유실로 볼 수 있다. 광물찌꺼기 적치장 하류수계를 따라 As 오염이 확인되었으며, 이러한 현상은 현 하천보다는 구 하천에서 상대적으로 높게 나타나고 있다. 이는 광물찌꺼기 적치장에 대한 유실방지시설을 설치하기 전에 구 하천으로 다량의 광물찌꺼기가 유실되었음을 의미한다. 또한 광물찌꺼기 적치장의 하류수계 농경지에서 하천 범람 시에 영향을 상대적으로 더 받게 되는 하천변 50 m 이내의 농경지 오염도가 50 m 이상의 농경지에 비해 높게 나타났다. 이러한 특성으로 볼 때, 유실된 광물찌꺼기가 하천을 따라 이동하다가 범람에 의해 농경지로 유입되면서 오염이 발생하는 경로도 주 오염경로로 판단된다.

농업용수의 미생물학적 안전성 조사 및 위생지표세균 농도와 병원성미생물 검출률과의 상관관계 분석 (Investigation of Microbial Safety and Correlations Between the Level of Sanitary Indicator Bacteria and the Detection Ratio of Pathogens in Agricultural Water)

  • 황인준;이태권;박대수;김은선;최송이;현정은;나겐드란 라자린감;김세리;조민
    • 한국환경농학회지
    • /
    • 제40권4호
    • /
    • pp.248-259
    • /
    • 2021
  • BACKGROUND: Contaminated water was a major source of food-borne pathogens in various recent fresh produce-related outbreaks. This study was conducted to investigate the microbial contamination level and correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water by logistic regression analysis. METHODS AND RESULTS: Agricultural water was collected from 457 sites including surface water (n=300 sites) and groundwater (n=157 sites) in South Korea from 2018 to 2020. Sanitary indicator bacteria (total coliform, fecal coliform, and Escherichia coli) and food-borne pathogens (pathogenic E. coli, E. coli O157:H7, Salmonella spp., and Listeria monocytogenes) were analyzed. In surface water, the coliform, fecal coliform, and E. coli were 3.27±0.89 log CFU/100 mL, 1.90±1.19 log CFU/100 mL, and 1.39±1.26 log CFU/100 mL, respectively. For groundwater, three kinds of sanitary indicators ranged in the level from 0.09 - 0.57 log CFU/100 mL. Pathogenic E. coli, Salmonella and Listeria monocytogenes were detected from 3%-site, 1.5%- site, and 0.6%-site water samples, respectively. According to the results of correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens by logistic regression analysis, the probability of pathogen detection increased individually by 1.45 and 1.34 times as each total coliform and E. coli concentration increased by 1 log CFU/100mL. The accuracy of the model was 70.4%, and sensitivity and specificity were 81.5% and 51.7%, respectively. CONCLUSION(S): The results indicate the need to manage the microbial risk of agricultural water to enhance the safety of fresh produce. In addition, logistic regression analysis is useful to analyze the correlation between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water.

태양전지용CuInSe2와 CuGaSe2 흡수층의 전자구조해석을 위한 표면 청정기술 개발 (Development of Surface Cleaning Techniques for Analysis of Electronics Structure in CuInSe2, CuGaSe2 Solar Cell Absorber Layer)

  • 김경환;최형욱;공석현
    • 한국전기전자재료학회논문지
    • /
    • 제18권2호
    • /
    • pp.125-129
    • /
    • 2005
  • Two kinds of physical treatments were examined for the analysis both of intrinsic surface and interior nature of CuInS $e_2$[CIS] and CuGaS $e_2$[CGS] films grown in separated systems. For the first method, a selenium protection layer which was immediately deposited after the growth of the CIS was investigated. The Se cap layer protects CISe surface from oxidation and contamination during the transport under ambient atmosphere. The Se cap was removed by thermal annealing at temperature above 15$0^{\circ}C$. After the decapping treatment at 2$25^{\circ}C$ for 60 min, ultraviolet photoemission and inverse photoemission measurements of the CIS film showed that its valence band maximum(VBM) and conduction band minimum (CBM) are located at 0.58 eV below and 0.52 eV above the Fermi level $E_{F}$, respectively. For the second treatment, an Ar ion beam etching was exploited. The etching with ion kinetic energy $E_{k}$ above 500 eV resulted in broadening of photoemission spectra of core signals and occasional development of metallic feature around $E_{F}$. These degradations were successfully suppressed by decreasing $E_{k}$ below 400 eV. CGS films etched with the beam of $E_{k}$ = 400 eV showed a band gap of 1.7 eV where $E_{F}$ was almost centered.st centered.

소하천형 호수의 수질개선을 위한 퇴적저니 처리방안 연구 (Treatment of Contaminated Sediment for Water Quality Improvement of Small-scale Reservoir)

  • 배우근;이창수;정진욱;최동호
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권4호
    • /
    • pp.31-39
    • /
    • 2002
  • 본 연구는 소하천형 호수의 수질개선 및 친환경적 생태공원조성을 위한 퇴적저니 처리방안을 수립하기 위하여 기존에 실시된 기본계획의 타당성 및 퇴적저니의 오염도 등을 검토하고 이를 토대로 최적의 퇴적저니 처리.처분계획을 수립하는데 목적이 있다. 퇴적저니의 정확한 오염도 분석을 위하여 총 9개 지점에 대해 저니층별로 23개소에 대한 퇴적저니를 채취하여 오염도를 분석한 결과 Cu의 경우 4개 시료가 지정폐기물 기준(3mg/L)을 초과하였다. 거의 전 지점의 시료가 농경지에 대한 Cu의 토양오염우려기준(50 mg/kg)을 초과한 것으로 조사되었다 그외 Pb및 Hg은 모두 기준이하로 분석되었다. 퇴적저니의 적정 처리방안을 수립하기 위하여 유기물 및 영양염류 오염도에 따른 퇴적저니의 준설필요성 여부를 국내 팔당호 및 한강하류 적용기준과 일본 동경만 및 요코하마만 적용기준에 의거 검토하고, 또한 중금속 오염도에 따른 퇴적저니의 처리여부를 일본, 미국 및 캐나다 기준을 적용하여 검토한 결과, 유기물 및 영양염류에 대한 오염도는 심각한 수준은 아니었으며, 유해물질에 의한 오염도는 일본기준에는 대부분 만족하나 저서생물에 미치는 악영향을 기준으로 설정된 미국 및 캐나다 기준에 대해서는 모두 중간오염 또는 심한오염에 해당하는 것으로 판정되었다. 그래서 퇴적저니 처리방안을 검토하기 위하여 선진국에서 많이 사용되고 있는 퇴적저니 정화방안중 중금속 안정화에 효과적인 고형화/안정화 방안을 검토한 결과 저니내의 Cu의 용출농도를 줄일 수 있었다. 또한 혼합된 시멘트 고화체는 높은 압축강도를 나타내어 건설용 토사나 제방성토용으로 사용 가능할 것으로 생각되었다. 나타내는 결과이다. 특별히 토양내 흡착력이 약하고 지하수내에 쉽게 용해될 수 있으며 독성 및 발암성물질로 알려진 사염화탄소와 같은 염소계 유기화합물의 제거에 효과적으로 적용될 수 있을 것으로 사료된다.3}$C(PDB)값은 -6.2~0.0$\textperthousand$범위이며, 그 기원은 대수층인 지층내 탄산염암 또는 탄산염 광물의 용해에서 유래한 무기기원 탄소로 해석된다.다.으로 변화하였으며 치료 전에 반응하지 않던 항원에 새롭게 반응하는 항체가 나타나는 경우는 드물었다.ms of chlorophyll-a concentration estimation, however, the accuracy stays very similar compared to that of the CZCS-type algorithm. This is considered to be due to the nature of in-water algorithm which relies on spectral ratio of water-leaving radiances.ethanol의 혈중농도(血中濃度)가 높을수록 더 심(甚)한 혈압강하작용(血壓降下作用)을 나타내며, ethanol 로 인(因)한 이뇨작용(利尿作用)도 ethanol 량(量)이 증가(增加)함에 따라 뇨량(尿量)도 증가(增加)함을 보여 주었다.ults showed that the overall quality of Sullungtang significantly decreased as the parity increased for Hanwoo cows. The Sullungtang extracted

국내 폐금은광산 주변 수계내의 As의 화학적 특성 (Chemical Speciation of Arsenic in the Water System from Some Abandoned Au-Ag Mines in Korea)

  • 이지민;이진수;전효택
    • 자원환경지질
    • /
    • 제36권6호
    • /
    • pp.481-490
    • /
    • 2003
  • 본 연구는 국내 폐금은광산 지역에서의 광산활동의 의한 (1)계의 물시료 및 퇴적물 내의 As의 오염 수준, (2)오염된 자연수 중에 존재하는 As의 화학종의 조사, (3)수계내 As의 건/우기에 따른 계절적 변화, (4)연속추출분석법을 이용한 퇴적물내의 As의 화학적 형태연구를 목적으로 한다. 본 연구를 위하여 국ㆍ내 6개의 폐금은광산 지역에 대하여 갱내수, 하천수 및 지하수 등의 자연수와 하강퇴적물을 채취하였다. 동일광산 갱내수의 As의 함량이 524${\mu}m$/L로 국내 광산폐수내 기준치(500 ${\mu}m$/L)를 초과하였으며, 하천수 역시 동일(63.7∼l17.6${\mu}m$/L) 구봉(56.1∼62.9${\mu}m$/L) 광산지역에서 부화되어 있었다. 연구지역내에서 음용수로 사용하고 있는 지하수내 비소의 함량은 동일, 옥동과 구봉광산에서 각각 11.3∼63.5${\mu}m$/L, 0.2∼68.9 ${\mu}m$/L과 2.0∼101.0${\mu}m$/L으로 일부 시료에서 국내 먹는 샘물 기준치(50${\mu}m$/L)를 초과하였다. 대부분의 수계에서 arsenate(As(V), $H_2AsO_4^-$)가 arsenite[As(III), $H_3AsO_3$]에 비해 우세한 존재형태이나 총As함량에 대한 arsenite(III)의 함량 비가 옥동광산지역의 하천수 시료에서 최고 95%까지 존재하고 있었으며 옥동과 동정광산 지역의 지하수에서는 70∼82%를 나타내었다. 수계내의 A저 계절적 변화의 관찰 결과, 동일광산지역의 수계에서 우기(9월 채취시료)에 비해 건기(4월 채취시료)에 상대적으로 부화된 양상을 명확히 보였다. 퇴적물에 대한 연속추출분석결과 As는 동정과 구봉광산의 시료에서 주로 비결정질 철수산화물과 공침전한 형태로 존재하고 있었으며(35.9∼40.5%) 이는 환원환경 하에서의 As의 재 용출에 의한 오염의 진행을 야기할 수 있다. 그러나, 동일 및 옥동 광산지역의 하강퇴적물은 주로 황화물 형태로 존재했다 (55.2∼83.4%).

TRIGA Mark-II, III 연구로 시절의 폐로를 위한 시설의 잔류 방사선/능 평가 (Evaluation of Residual Radiation and Radioactivity Level of TRIGA Mark-II, III Research Reactor Facilities for Safe Decommissioning)

  • 이봉재;장시영;박승국;정운수;정기정
    • Journal of Radiation Protection and Research
    • /
    • 제24권2호
    • /
    • pp.109-120
    • /
    • 1999
  • TRIGA Mark-II, III 연구로를 폐로함에 따라, 원자로를 비롯한 관련 시설로부터 작업자의 방사선피폭을 최소화하고 환경으로의 방사성물질 누출을 사전에 방지하며, 안전한 해체방법을 모색하여 해체공사시의 기술기준을 수립하기 위하여 해체대상 시설내에 잔존하고 있는 방사성물질의 방사선/능 준위를 측정 및 분석 평가하였다. 측정대상은 시설내의 바닥 및 벽면과 잔존 실험시설물의 표면, 수조내 방사화 물질의 표면, 시설내 잔존하고 있는 냉각수 등이다. 이들 측정대상에 대한 방사선량율과 표면오염도, 핵종 등을 측정, 분석 및 평가하였다. 또한 전산코드 Fispin 을 사용하여 원자로 수조내의 주요 방사화 물질에 대한 방사능양과 핵종을 평가하였다. 본 평가 결과는 해체계획서 작성시 기본자료로서 유용하게 사용되었다.

  • PDF