Browse > Article
http://dx.doi.org/10.5668/JEHS.2014.40.4.304

Assessment of Bioaerosols in Public Restrooms  

Kim, Jong-Gyu (Department of Public Health, Keimyung University)
Kim, A-Hyeok (Department of Public Health, Keimyung University)
Kim, Joong-Soon (Department of Industrial and Management Engineering, Keimyung University)
Publication Information
Journal of Environmental Health Sciences / v.40, no.4, 2014 , pp. 304-312 More about this Journal
Abstract
Objectives: This study was performed to examine bioaerosols in indoor air in public restrooms, as well as to assess the effects of air temperature and relative humidity on bioaerosol levels. Methods: A cross-sectional survey was performed in ten male and ten female restrooms. An air sampler (Anderson type) was used for sampling total suspended bacteria (TSB), Gram-negative bacteria (GNB), Gram-positive bacteria (GPB), opportunistic bacteria (OP), Staphylococcus spp., and total suspended fungi (TSF). Results: The levels of TSB were $10-10^2CFU/m^3$ and TSF $10-10^2CFU/m^3$, respectively. The GNB level was $0-10CFU/m^3$, and GPB and OP levels were $10-10^2CFU/m^3$. Staphylococcus aureus and methicillin-resistant S. aureus (MRSA) were detected in 90% of the restrooms. The GPB level was higher in the female restrooms than in the male restrooms (p < 0.05). TSB, GNB, and TSF showed higher levels in restrooms in buildings over 30 years old (p < 0.01). The main effect of air temperature or relative humidity and interaction effect of the two factors on the TSB level were significant (p < 0.05), while the effect of relative humidity on the TSF level was significant (p < 0.001). Conclusions: These results indicate that there is a wide variation in the bioaerosol levels among different restrooms. The observed differences in bioaerosol levels reflect different building histories. The effects of air temperature and/or relative humidity reveal that bioaerosol levels may vary according to season or time of day. Future research is needed to further characterize the relation between the bioaerosol levels and surface contamination in restrooms.
Keywords
Bioaerosol; Indoor air; Restrooms;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 Scott E, Bloomfield SF, Barlow CG. An investigation of microbial contamination in the home. J Hyg Lond. 1982; 89(2): 279-293.   DOI
2 Park D, Jo K, Yoon C, Han I, Park D. Factors influencing airborne concentration of fungi, bacteria and gram negative bacteria in kindergarten classroom. Kor J Environ Health. 2004; 30(5): 440-448.   과학기술학회마을
3 Park D, Yeom J, Lee W, Lee K. Assessment of the levels of airborne bacteria, gram-negative bacteria, and fungi in hospital lobbies. Int J Environ Res Public Health. 2013; 10(2): 541-555.   DOI
4 Kim SD. Distribution characteristics of bioaerosol in indoor air of apartments. [dissertation]. [Seoul]: Korea University; 2011.
5 Verani M, Biqazzi R, Carducci A. Viral contamination of aerosol and surfaces through toilet use in health care and other settings. Am J Infect Control. 2014; 42(7): 758-762.   DOI
6 Moon KW, Byeon SH, Choi DW, Kim YW, Lee JH, Lee EI. Exposure assessments on biological contaminants in homes of allergy patients - bacteria, fungi, house dust mite allergen and endotoxin. J Environ Health Sci. 2005; 31(2): 120-126.   과학기술학회마을
7 Mkrtchyan HV, Russell CA, Wang N, Cutler RR. Could public restrooms be an environment for bacterial resistomes?. PLoS One. 2013; 8(1): e54223.   DOI
8 Cleaning Industry Research Institute. Enteric Bacterial Contamination of Public Restrooms. Available: http://www.ciriscience.org/a_67-Enteric_Bacterial_Contamination_of_Public_Restrooms [accessed 14 April 2014].
9 Kwon MH, Choi KH, Seo SY, Ryu JM, Won SR, Lim JH, et al. A Study on management of major indoor air pollutants by house type in Korea(II) - Indoor air pollutants and health effects in residential detached and multiplex/terraced house. Inchon: NIER Press; 2010. p.13-19.
10 Sabra SMM. Bacterial public health hazard in the public female restrooms at Taif, KSA. Middle-East J Sci Res. 2013; 14(1): 63-68.
11 Flores GE, Bates ST, Knights D, Lauber CL, Stombaugh J, Knight R, et al. Microbial biogeography of public restroom surfaces. PloS One. 2011; 6(11): e28132.   DOI
12 Barker J, Bloomfield SF. Survival of Salmonella in bathrooms and toilets in domestic homes following salmonellosis. J Appl Microbiol. 2000; 89(1): 137-144.   DOI   ScienceOn
13 Reynolds KA. Germs in the Home Environment: Microorganisms in the Bathroom. Available: http://learnaboutgerms. arizona.edu/germs_in_the_environment. htm. [accessed 14 April 2014].
14 Gerba CP, Wallis C, Melnick JL. Microbiological hazards of household toilets: droplet production and the fate of residual organisms. Appl Microbiol. 1975; 30(2): 229-237.
15 Barker J, Jones M. The potential spread of infection caused by aerosol contamination of surfaces after flushing a domestic toilet. J Appl Microbiol. 2005; 99(2): 339-347.   DOI   ScienceOn
16 Abdullah ASM, Tomlinson B, Cockram CS, Thomas GN. Lessons from the severe acute respiratory syndrome outbreak in Hong Kong. Emerg Infect Dis. 2003; 9(9): 1042-1045.   DOI
17 Li Y, Leung GM, Tang JW, Yang X, Chao CYH, Lin JZ, et al. Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review. Indoor Air. 2007; 17(1): 2-18.   DOI   ScienceOn
18 Choi HY, Kwon WO, Lee WS, Lee H. Research on bacterial distribution of public lavatory. J Environ Health Sci. 2012; 38(6): 520-528.
19 Kulmala M, Asmi A, Pirjola L. Indoor air aerosol model: the effect of outdoor air, filtration and ventilation on indoor concentrations. Atmos Environ. 1999; 33(14): 2133-2144.   DOI
20 Pasanen AL, Kasane JP, Rautiala S, Ikaheimo M, Rantamaki J, Kaariainen H, et al. Fungal growth and survival in building materials under fluctuating moisture and temperature conditions. Int Biodeter Biodegr. 2000; 46(2): 117-127.   DOI
21 Mandal J, Brandl H. Bioaerosols in indoor environment - a review with special reference to residential and occupational locations. Open Environ Biol Monit J. 2011; 4(1): 83-96.   DOI
22 Kalwasinska A, Burkowska A, Wilk I. Microbial air contamination in indoor environment of the university library. Ann Agric Environ Med. 2012; 19(1): 25-29.
23 Kim JG, Kim JS. The load of indicator bacteria of sanitary ware in public restrooms. J Environ Health Sci. 2014; 40(1): 63-70.
24 Yeon JW, Chang MW, Kim KH. Detection and isolation of genital Mycoplasmas from public toilet bowls. J Bacteriol Virol. 2002; 32(3): 231-237.
25 Kim KH, Yee JJ. Applicability of corrugate type absorption filter for elimination of offensive odor substance in the toilet. J Archit Inst Kor Plan Des. 2010; 26(6): 279-286.   과학기술학회마을
26 Kim JG, Park JY, Kim JS. Assessment of bacterial and fungal aerosols in the kitchens of restaurants. J Environ Health Sci. 2014; 40(2): 98-104.
27 Lee BU, Hong IG, Lee DH, Chong ES, Jung JH, Lee JH, et al. Bacterial bioaerosol concentrations in public restroom environments. Aerosol Air Qua Res. 2012; 12(2): 251-255.
28 Im MJ, Kim SD. A field study on the concentration of suspended microbes by living space. Proceedings of Kor Soc Odor Res Eng. 2005; 11: 50-53.
29 Korea Ministry of Government Legislation. Indoor Air Quality Control in Public Use Facilities. Available: http://www.law.go.kr/lsSc.do?menuId=0&p1=&sub-Menu=1&nwYn=1&query=%EB%8B%A4%EC%A4%91&x=0&y=0#liBgcolor0. [accessed 12 February 2014].
30 WHO. Household Air Pollution and Health. Available: http://www.who.int/mediacentre/factsheets/fs292/en/(2005). [accessed 12 February 2014].
31 National Institute of Environmental Research. Sampling Method for Microbiological Testing of Indoor Air. Available: http://iaqinfo.nier.go.kr/means/sampling _crowd_facilities.do. [accessed 23 November 2013].